期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Valproic acid as a micro RNA modulator to promote neurite outgrowth 被引量:1
1
作者 Hirotaka Oikawa Judy C.G.Sng 《Neural Regeneration Research》 SCIE CAS CSCD 2016年第10期1564-1565,共2页
Valproic acid (VPA) has been a first-choice drug for clinical treatment of epilepsy and manic disorder. For decades, its phar- macological action was believed to act on inhibition of gam- ma-aminobutyric acid (GABA... Valproic acid (VPA) has been a first-choice drug for clinical treatment of epilepsy and manic disorder. For decades, its phar- macological action was believed to act on inhibition of gam- ma-aminobutyric acid (GABA) transaminase, in turn, increas- ing GABA in inhibitory synapses. However, in recent years, VPA has been investigated on other therapeutic actions. Those investigations demonstrate that VPA shows neuroprotective ef- fects by promoting neurogenesis, neuronal differentiation, and neuroregeneration (Foti et al., 2013). 展开更多
关键词 VPA RNA Valproic acid as a micro RNA modulator to promote neurite outgrowth ACID
下载PDF
Micro EEG/ECG signal's chopper-stabilization amplifying chip for novel drycontact electrode 被引量:1
2
作者 Jianhui Sun Chunxing Wang +8 位作者 Gongtang Wang Jinhui Wang Qing Hua Chuanfu Cheng Xinxia Cai Tao Yin Yang Yu Haigang Yang Dengwang Li 《Journal of Semiconductors》 EI CAS CSCD 2017年第2期96-104,共9页
Facing the body's EEG(electroencephalograph, 0.5–100 Hz, 5–100 μV) and ECG's(electrocardiogram,〈 100 Hz, 0.01–5 mV) micro signal detection requirement, this paper develops a pervasive application micro sign... Facing the body's EEG(electroencephalograph, 0.5–100 Hz, 5–100 μV) and ECG's(electrocardiogram,〈 100 Hz, 0.01–5 mV) micro signal detection requirement, this paper develops a pervasive application micro signal detection ASIC chip with the chopping modulation/demodulation method. The chopper-stabilization circuit with the RRL(ripple reduction loop) circuit is to suppress the ripple voltage, which locates at the single-stage amplifier's outputting terminal. The single-stage chopping core's noise has been suppressed too, and it is beneficial for suppressing noises of post-circuit. The chopping core circuit uses the PFB(positive feedback loop) to increase the inputting resistance, and the NFB(negative feedback loop) to stabilize the 40 dB intermediate frequency gain. The cascaded switch-capacitor sample/hold circuit has been used for deleting spike noises caused by non-ideal MOS switches, and the VGA/BPF(voltage gain amplifier/band pass filter) circuit is used to tune the chopper system's gain/bandwidth digitally. Assisted with the designed novel dry-electrode, the real test result of the chopping amplifying circuit gives some critical parameters: 8.1 μW/channel, 0.8 μVrms(@band-widthD100 Hz), 4216–11220 times digitally tuning gain range, etc. The data capture system uses the NI CO's data capturing DAQmx interface,and the captured micro EEG/ECG's waves are real-time displayed with the PC-Labview. The proposed chopper system is a unified EEG/ECG signal's detection instrument and has a critical real application value. 展开更多
关键词 EEG/ECG novel dry-contact electrode weak and micro signal detection chopping modulation/demodulation de-noising gain/band width digitally tuning
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部