A miniaturized broadband Wilkinson power divider is proposed. Micro-strip branch lines are introduced to replace multiple resistors used in multi-stage Wilkinson power dividers to increase the bandwidth of single-stag...A miniaturized broadband Wilkinson power divider is proposed. Micro-strip branch lines are introduced to replace multiple resistors used in multi-stage Wilkinson power dividers to increase the bandwidth of single-stage Wilkinson power dividers. To demonstrate its performance, an improved single-stage Wilkinson power divider with four micro-strip branch lines was designed. Simulated results show that the insert loss is better than 3.2 dB, the input return loss, output return loss, and isolation are better than 15 dB respectively, across a 76% bandwidth from 18 to 40 GHz. .展开更多
In this work, we applied two electromagnetic models for the characterization of a planar structure including a flat, thick copper conductor. Indeed the first model is consisted by modeling two metal ribbons without bu...In this work, we applied two electromagnetic models for the characterization of a planar structure including a flat, thick copper conductor. Indeed the first model is consisted by modeling two metal ribbons without bulkiness, placed one above the other at a distance of h<sub>2</sub> equal to the thickness of the thick conductor. This approach has been implemented and tested by the iterative method. The results of simulations have been compared with those calculated by the Ansoft HFSS software, and they are in good concordance, validating the method of analysis used. The second model is based on the calculation of the effective permittivity of the medium containing the thick conductor. This medium consists of a metallic region of complex relative permittivity , the rest of this medium is filled with air e<sub>r</sub><sub>2</sub> = 1. The effective permittivity e<sub>eff</sub> calculated from these two relative permittivity e<sub>r</sub><sub>2</sub> and . Comparing the simulation results of this new formulation of the iterative method with those calculated by the software Ansoft HFSS shows that they are in good matching which validates the second model.展开更多
Efforts to protect electric power systems from faults have commonly relied on the use of ultra-high frequency(UHF)antennas for detecting partial discharge(PD)as a common precursor to faults.However,the effectiveness o...Efforts to protect electric power systems from faults have commonly relied on the use of ultra-high frequency(UHF)antennas for detecting partial discharge(PD)as a common precursor to faults.However,the effectiveness of existing UHF antennas suffers from a number of challenges such as limited bandwidth,relatively large physical size,and low detection sensitivity.The present study addresses these issues by proposing a compact microstrip patch antenna with fixed dimensions of 100 mm×100 mm×1.6 mm.The results of computations yield an optimized antenna design consisting of 2nd-order Hilbert fractal units positioned within a four-layer serpentine arrangement with a fractal unit connection distance of 3.0 mm.Specifically,the optimized antenna design achieves a detection bandwidth for which the voltage standing wave ratio is less than 2 that is approximately 97.3%of the UHF frequency range(0.3–3 GHz).Finally,a prototype antenna is fabricated using standard printed circuit board technology,and the results of experiments demonstrate that the proposed antenna is capable of detecting PD signals at a distance of 8 m from the discharge source.展开更多
文摘A miniaturized broadband Wilkinson power divider is proposed. Micro-strip branch lines are introduced to replace multiple resistors used in multi-stage Wilkinson power dividers to increase the bandwidth of single-stage Wilkinson power dividers. To demonstrate its performance, an improved single-stage Wilkinson power divider with four micro-strip branch lines was designed. Simulated results show that the insert loss is better than 3.2 dB, the input return loss, output return loss, and isolation are better than 15 dB respectively, across a 76% bandwidth from 18 to 40 GHz. .
文摘In this work, we applied two electromagnetic models for the characterization of a planar structure including a flat, thick copper conductor. Indeed the first model is consisted by modeling two metal ribbons without bulkiness, placed one above the other at a distance of h<sub>2</sub> equal to the thickness of the thick conductor. This approach has been implemented and tested by the iterative method. The results of simulations have been compared with those calculated by the Ansoft HFSS software, and they are in good concordance, validating the method of analysis used. The second model is based on the calculation of the effective permittivity of the medium containing the thick conductor. This medium consists of a metallic region of complex relative permittivity , the rest of this medium is filled with air e<sub>r</sub><sub>2</sub> = 1. The effective permittivity e<sub>eff</sub> calculated from these two relative permittivity e<sub>r</sub><sub>2</sub> and . Comparing the simulation results of this new formulation of the iterative method with those calculated by the software Ansoft HFSS shows that they are in good matching which validates the second model.
文摘Efforts to protect electric power systems from faults have commonly relied on the use of ultra-high frequency(UHF)antennas for detecting partial discharge(PD)as a common precursor to faults.However,the effectiveness of existing UHF antennas suffers from a number of challenges such as limited bandwidth,relatively large physical size,and low detection sensitivity.The present study addresses these issues by proposing a compact microstrip patch antenna with fixed dimensions of 100 mm×100 mm×1.6 mm.The results of computations yield an optimized antenna design consisting of 2nd-order Hilbert fractal units positioned within a four-layer serpentine arrangement with a fractal unit connection distance of 3.0 mm.Specifically,the optimized antenna design achieves a detection bandwidth for which the voltage standing wave ratio is less than 2 that is approximately 97.3%of the UHF frequency range(0.3–3 GHz).Finally,a prototype antenna is fabricated using standard printed circuit board technology,and the results of experiments demonstrate that the proposed antenna is capable of detecting PD signals at a distance of 8 m from the discharge source.