An integrated microball lens fiber catheter probe is demonstrated, which has better lateral resolution and longer working distance than a corresponding bare fiber probe with diverging beam for Fourier domain optical c...An integrated microball lens fiber catheter probe is demonstrated, which has better lateral resolution and longer working distance than a corresponding bare fiber probe with diverging beam for Fourier domain optical coherence tomography (FDOCT). Simulation results are shown to gain the effect of the distance between the mieroball lens and the bare fiber to the focusing plane and beam width. The freedom of modifying the working distance and lateral resolution is shown. This is achieved by changing the gap distance between the single-mode fiber and the microball lens within the packaged surgical needle catheter without using an additional beam expander having a fixed length. The probe successfully acquired crosssectional images of ocular tissues from an animal sample with the proposed miniaturized imaging probe.展开更多
N-doped porous carbon has been extensively investigated for broad electrochemical applications.The performance is significantly impacted by the electrochemical double layer(EDL),which is material dependent and hard to...N-doped porous carbon has been extensively investigated for broad electrochemical applications.The performance is significantly impacted by the electrochemical double layer(EDL),which is material dependent and hard to characterize.Limited understanding of doping-derived EDL structure hinders insight into the structure-performance relations and the rational design of high-performance materials.Thus,we analyzed the mass and chemical composition variation of EDL within electrochemical operation by electrochemical quartz crystal microbalance,in-situ X-ray photoelectron spectroscopy,and time-offlight secondary ion mass spectrometry.We found that N-doping triggers specifically adsorbed propylene carbonate solvent in the inner Helmholtz plane(IHP),which prevents ion rearrangement and enhances the migration of cations.However,this specific adsorption accelerated solvent decomposition,rendering rapid performance degradation in practical devices.This work reveals that the surface chemistry of electrodes can cause specific adsorption of solvents and change the EDL structure,which complements the classical EDL theory and provide guidance for practical applications.展开更多
We present a new polymer quartz piezoelectric crystal sensor that takes a quartz piezoelectric crystal as the basal material and a nanometer nonmetallic polymer thin film as the surface coating based on the principle ...We present a new polymer quartz piezoelectric crystal sensor that takes a quartz piezoelectric crystal as the basal material and a nanometer nonmetallic polymer thin film as the surface coating based on the principle of quartz crystal microbalance(QCM). The new sensor can be used to detect the characteristic materials of a volatile liquid. A mechanical model of the new sensor was built, whose structure was a thin circle plate composing of polytef/quartz piezoelectric/polytef. The mechanical model had a diameter of 8 mm and a thickness of 170 μm. The vibration state of the model was simulated by software ANSYS after the physical parameters and the boundary condition of the new sensor were set. According to the results of experiments, we set up a frequency range from 9.995850 MHz to 9.997225 MHz, 17 kinds of frequencies and modes of vibration were obtained within this range. We found a special frequency fspof 9.996358 MHz. When the resonant frequency of the new sensor's mechanical model reached the special frequency, a special phenomenon occurred. In this case, the amplitude of the center point O on the mechanical model reached the maximum value. At the same time, the minimum absolute difference between the simulated frequency based on the ANSYS software and the experimental measured stable frequency was reached. The research showed that the design of the new polymer quartz piezoelectric crystal sensor perfectly conforms to the principle of QCM. A special frequency value fspwas found and subsequently became one of the most important parameters in the new sensor design.展开更多
A biosensor is an analytical device used for the detection of analytes,which combines a biological component with a physicochemical detector.Recently,an increasing number of biosensors have been used in clinical resea...A biosensor is an analytical device used for the detection of analytes,which combines a biological component with a physicochemical detector.Recently,an increasing number of biosensors have been used in clinical research,for example,the blood glucose biosensor.This review focuses on the current state of biosensor research with respect to efficient,specific and rapid detection of hepatitis B virus(HBV).The biosensors developed based on different techniques,including optical methods(e.g.,surface plasmon resonance),acoustic wave technologies(e.g.,quartz crystal microbalance),electrochemistry(amperometry,voltammetry and impedance) and novel nanotechnology,are also discussed.展开更多
The influence rules of square micro-pillar array porosity on the liquid motion characteristics of the near-surface layer are investigated by quartz crystal microbalance(QCM).QCM is a powerful and promising technique i...The influence rules of square micro-pillar array porosity on the liquid motion characteristics of the near-surface layer are investigated by quartz crystal microbalance(QCM).QCM is a powerful and promising technique in studying the interfacial behavior,which exhibits great advantages in investigating the effects of surface microstructure,roughness,and array.In our experiments,three different arrays with the same height of about 280 nm and center distance of 200μm,but different diameters of about 78μm,139μm,and 179μm are investigated.The results indicate that when the surface array has a large porosity,its influence on the liquid motion of the near surface layer is slight,thus resulting in a small increase of half-bandwidth variation due to the additional friction energy dissipation.When the surface array has a small porosity,the array tends to make the liquid film trapped in the array oscillating with the substrate,then there may be a layer of liquid film behaving like rigid film,and it also will make the liquid motion near the array layer more complicated.Thus for the#3 surface with a small porosity,both the absolute values of frequency shift|Δf3|and half-bandwidth variationΔΓ3 increase obviously.The experimental results show good consistence with the theoretical model of Daikhin and Urbakh.This study sheds light on understanding the influence mechanism of surface array porosity on the liquid motion of near-surface layer.展开更多
Porphyrin-filled nanofibrous membranes were facilely prepared by electrospinning of the mixtures of poly(acrylonitrile-co-acrylic acid)(PANCAA) and porphyrins. 5,10,15,20-Tetraphenylporphyrin(TPP) and its metal-...Porphyrin-filled nanofibrous membranes were facilely prepared by electrospinning of the mixtures of poly(acrylonitrile-co-acrylic acid)(PANCAA) and porphyrins. 5,10,15,20-Tetraphenylporphyrin(TPP) and its metal-loderivatives(ZnTPP and CuTPP) were studied as filling mediators for the immobilization of redox enzyme. Results indicate that the introduction of TPP, ZnTPP and CuTPP improves the retention activity of the immobilized catalase. Among these three porphyrins, the ZnTPP-filled PANCAA nanofibrous membrane exhibits an activity retention of 93%, which is an exciting improvement. This improvement is attributed to both the strong catalase-porphyrin affinity and the possible facilitated electron transfer induced by the porphyrin as evidenced by quartz crystal microbalance (QCM) and fluorescence spectroscopy studies.展开更多
In this study, we have used a direct immunoassay where the simple binding between antigen and an antibody is detected. Immunoassays were performed in a drop system, monitoring the frequency decrease of the quartz-crys...In this study, we have used a direct immunoassay where the simple binding between antigen and an antibody is detected. Immunoassays were performed in a drop system, monitoring the frequency decrease of the quartz-crystal microbalance device because of mass increasing during immunoreaction. The QCM sensor was coated on both sides by gold electrodes, only one side of the crystal (liquid side) was in contact with the solution;the other side (contact side) was always dry. We tested a piezoelectric immunosensor for aflatoxin B1 (AFLA-B1) mycotoxin detection through the immo- bilization of DSP-anti-AFLAB1 antibody (AFLA-B1-Ab anti AFLAB1) on gold-coated quartz crystals (AT-cut/5 MHz). The DSP (3,3’-Dithiodipropionic-acid-di-N-hydroxysuccinimide ester) was used for the covalent attachment of the proteins. The piezoelectric crystal electrodes were pretreated by DSP for 15 min, rinsed with water and dried in a gentle flow of nitrogen gas. Then the DSP-coated crystals were installed in a sample holder and exposed to the anti-AFLAB1 antibody and to the AFLA-BI. Frequency and resistance shifts (Δf and ΔR) were measured simultaneously. Δf versus AFLA-BI concentrations in the range of 0.5 - 10 ppb exhibited a perfect linear correlation with a coefficient of above 0.998.展开更多
The fast and accurate identification of nerve tracts is critical for successful nerve anastomosis. Taking advantage of differences in acetylcholinesterase content between the spinal ventral and dorsal roots, we develo...The fast and accurate identification of nerve tracts is critical for successful nerve anastomosis. Taking advantage of differences in acetylcholinesterase content between the spinal ventral and dorsal roots, we developed a novel quartz crystal microbalance method to distinguish between these nerves based on acetylcholinesterase antibody reactivity. The acetylcholinesterase antibody was immobilized on the electrode surface of a quartz crystal microbalance and reacted with the acetylcholinesterase in sample solution. The formed antigen and antibody complexes added to the mass of the electrode inducing a change in frequency of the electrode. The spinal ventral and dorsal roots were distinguished by the change in frequency. The ventral and dorsal roots were cut into 1 to 2-mm long segments and then soaked in 250 pL PBS. Acetylcholinesterase antibody was immobilized on the quartz crystal microbalance gold electrode surface. The results revealed that in 10 minutes, both spinal ventral and dorsal roots induced a frequency change; however, the frequency change induced by the ventral roots was notably higher than that induced by the dorsal roots. No change was induced by bovine serum albumin or PBS. These results clearly demonstrate that a quartz crystal microbalance sensor can be used as a rapid, highly sensitive and accurate detection tool for the quick identification of spinal nerve roots intraoperatively.展开更多
On the basis of thin film lubrication theory, the influence of fluid film(disordered film), ordered film and adsorbed film on tribological behavior of lubricating oil in thin-film lubrication(TFL) regime was studied. ...On the basis of thin film lubrication theory, the influence of fluid film(disordered film), ordered film and adsorbed film on tribological behavior of lubricating oil in thin-film lubrication(TFL) regime was studied. The μ-L(friction coefficient versus load) curves of different oil viscosity and additive dosage were obtained by a high frequency reciprocating test rig and the adsorption capacity of additive on steel surface were measured by QCM-D. Based on the Stribeck curve and thin film lubrication theory model, some conclusions can be drawn up, namely:(1) The μ-L curves and the parameters of L0 and μ0, obtained from the high frequency reciprocating test rig with ball-disc contact, can be used to study tribological behaviors of lubricating oil under TFL conditions.(2) In comparison with the high viscosity base fluid, the lower one can enter into TFL regime under lower load and keeps a lower friction coefficient in TFL regime.(3) The polar molecules in additive formulation produce ordered adsorbed layer on steel surface to reduce friction coefficient. And in TFL regime, the molecule's polarity, layer thickness and saturation degree on steel surface probably can influence lubricant's tribological behaviors between the moving interfaces. Moreover, the further study would be focused on the competitive adsorption of different additives, the formation of dual- and/or tri-molecular adsorption layers, and other aspects.展开更多
A dichlorosilane gas and a trichlorosilane gas in ambient hydrogen were evaluated to show their different gas flow motions in a slim vertical cold wall chemical vapor deposition reactor for the Minimal Fab system. Thi...A dichlorosilane gas and a trichlorosilane gas in ambient hydrogen were evaluated to show their different gas flow motions in a slim vertical cold wall chemical vapor deposition reactor for the Minimal Fab system. This evaluation was performed for improving and controlling the film qualities and the productivities, using two quartz crystal microbalances (QCM) installed at the </span><span style="font-family:Verdana;">inlet and exhaust of the chamber by taking into account that the QCM frequency corresponds to the real time changes in the gas properties.</span><span style="font-family:Verdana;"> Typically, the time period approaching from the inlet to the exhaust was shorter for the trichlorosilane gas than that for the dichlorosilane gas. The trichlorosilane gas was shown to move like plug flow, while the dichlorosilane gas seemed to be well mixed in the entire chamber.展开更多
The effects of surface adsorption of bovine serum albumin(BSA) and human gamma-globulin(HGG) on the tribological performance of a DLC film were investigated using a quartz crystal microbalance with dissipation(QCM-D),...The effects of surface adsorption of bovine serum albumin(BSA) and human gamma-globulin(HGG) on the tribological performance of a DLC film were investigated using a quartz crystal microbalance with dissipation(QCM-D), a ball-on-disk reciprocating tribometer, and a three-electrode electrochemical cell. The results showed that the wear depth in the BSA solution was higher than that in the HGG solution. In the HGG solution, the HGG-adsorbed layer could act as a lubricating layer and protect the DLC film from wear. The wear volume of DLC film in BSA and HGG mixture solution was higher than that in single HGG solution. This may be because the BSA molecules inhibit the formation of HGG adsorbed layer during sliding.展开更多
A quartz crystal microbalance (QCM) is used to determine the phase equilibrium of paclitaxel-carbon dioxide system in the pressure range of 0-11 MPa and at temperatures of 35 °C,40 °C and 45 °C.The ex...A quartz crystal microbalance (QCM) is used to determine the phase equilibrium of paclitaxel-carbon dioxide system in the pressure range of 0-11 MPa and at temperatures of 35 °C,40 °C and 45 °C.The experimental results indicated that gaseous CO2 could be absorbed poorly into paclitaxel.The swelling of paclitaxel film in CO2 was observed before paclitaxel dissolved into supercritical carbon dioxide (ScCO2) with the increase of pressure.It was found that ScCO2 was not a good solvent for paclitaxel.The mole fraction of paclitaxel in ScCO2 was in the range of (4.5×10-9)-(7.8×10-9) under all our experimental conditions.Therefore,a much higher pressure than the CO2 supercritical point and/or a cosolvent must be used in any processes wherever paclitaxel dissolution in ScCO2 is required.展开更多
A new method of determination of trace CNin water was proposed.A thin film of AgS was electrochemically deposited on both sides of a silver coated piezoelectric crystal.The AgS Ag films can react with CN selectively,w...A new method of determination of trace CNin water was proposed.A thin film of AgS was electrochemically deposited on both sides of a silver coated piezoelectric crystal.The AgS Ag films can react with CN selectively,which causes the frequency shifts of the piezoelectric crystal.The frequency shifts are proportional to the concentration of CN in the range of 106~10'g/L.XPS experiments indicated the sensing film was AgiS Ag.A coordination complex Ag-CNwas formed when AgiS Ag film contacted with solution containing CNion.A response mechanism was proposed based on the XPS data.展开更多
The in situ electrochemical quartz crystal microbalance(EQCM) technique was used to investigate the ion transport of immobilized heteropolyanions at a self-assembled monolayer(SAM) modified gold electrode during e...The in situ electrochemical quartz crystal microbalance(EQCM) technique was used to investigate the ion transport of immobilized heteropolyanions at a self-assembled monolayer(SAM) modified gold electrode during electrochemical redox process.A mixed transfer method was presented to analyse the abnormal change of resonant frequency based on the simultaneous insertion/extraction of different ions.The results indicate that the migration of HSO4-anions was indispensable in the redox process of the heteropolyanions in a 1 mol/L H2SO4 solution and played a key role in the abnormal change of the resonant frequency.Such a change was attributed to different packing densities derived by means of differently immobilized methods.展开更多
The effect of salt concentration on layer-by-layer deposition of poly(sodium 4-styrene sulfonate) (PSSS)/poly(vinylbenzyl trimethylammonium chloride) (PVTC) was investigated by use of quartz crystal microbalan...The effect of salt concentration on layer-by-layer deposition of poly(sodium 4-styrene sulfonate) (PSSS)/poly(vinylbenzyl trimethylammonium chloride) (PVTC) was investigated by use of quartz crystal microbalance with dissipation (QCM-D). The changes in frequency and dissipation demonstrate that the addition of NaC1 leads the thickness of PSSS/PVTC multilayer to increase. The deposition of PSSS/PVTC is dominated by surface charge overcompensation level at lower salt concentrations. However, it is mainly determined by the interpenetration of polyelectrolytes at a higher salt concentration, as reflected in the oscillation of dissipation change.展开更多
Pd was electrochemically deposited on gold-coated quartz crystals at nanogram-level. The coulombic efficiency and initial nucleation and growth mechanism of potentiostatic Pd deposition were investigated via in situ e...Pd was electrochemically deposited on gold-coated quartz crystals at nanogram-level. The coulombic efficiency and initial nucleation and growth mechanism of potentiostatic Pd deposition were investigated via in situ electrochemical quartz crystal microbalance(EQCM). The coulombic efficieneies are 84%, 93% and 95% for Pd deposition at 0.3, 0.2 and 0.1 V(vs. SCE), respectively. The results of chronoamperometric measurements show that the Pd deposition proceeded by an instantaneous nucleation(at 0.3 V) or progressive nucleation(at 0.2 and 0.1 V) in a three-dimensional(3D) growth mode. The catalytic activity of Pd-based electrocatalyst for ethanol oxidation was characterized in an alkaline solution. It was found that the highest mass activity for ethanol oxidation on Pd-based electrocatalyst is 1.8× 10^4 A/(g Pd) deposited at 0.3 V for 5 s.展开更多
The quartz crystal microbalance(QCM) is an important tool that can sense nanogram changes in mass. The hybrid temperature effect on a QCM resonator in aqueous solutions leads to unconvincing detection results. Contr...The quartz crystal microbalance(QCM) is an important tool that can sense nanogram changes in mass. The hybrid temperature effect on a QCM resonator in aqueous solutions leads to unconvincing detection results. Control of the temperature effect is one of the keys when using the QCM for high precision measurements. Based on the Sauerbrey's and Kanazawa's theories, we proposed a method for enhancing the accuracy of the QCM measurement, which takes into account not only the thermal variations of viscosity and density but also the thermal behavior of the QCM resonator. We presented an improved Sauerbrey equation that can be used to effectively compensate the drift of the QCM resonator. These results will play a significant role when applying the QCM at the room temperature.展开更多
The adsorption of fibrinogen can be used as a quick indicator of surface haemocompatibility because of its prominent role in coagulation and platelet adhesion. In this work the molecular interaction between fibrinogen...The adsorption of fibrinogen can be used as a quick indicator of surface haemocompatibility because of its prominent role in coagulation and platelet adhesion. In this work the molecular interaction between fibrinogen and a modified titanium oxide surface/platelet has been studied by quartz crystal microbalanee with dissipation (QCM-D) in situ. In order to further characterize the conformation of adsorbed fibrinogen, αC and γ-chain antibody were used to check the orientation and denaturation of fibrinogen on solid surface. QCM-D investiga- tions revealed the fibrinogen have the trend to adsorb on hydropllilic surface in a side-on orientation by positively charged αC domains, which would reduce the exposure of platelet bonding site on γ chain and enable less platelet adhesion and be activated. These obser- vations suggest that certain conformations of adsorbed fibrinogen are less platelet adhesive than others, which opens a possibility for creating a non-platelet adhesive substrates.展开更多
基金supported by the World Class University Program funded by the Ministry of Education, Science, and Technology through the National Research Foundation of Korea (No. R31-10008)supported in part by NIH (No. BRP 1R01 EB 007969- 01)
文摘An integrated microball lens fiber catheter probe is demonstrated, which has better lateral resolution and longer working distance than a corresponding bare fiber probe with diverging beam for Fourier domain optical coherence tomography (FDOCT). Simulation results are shown to gain the effect of the distance between the mieroball lens and the bare fiber to the focusing plane and beam width. The freedom of modifying the working distance and lateral resolution is shown. This is achieved by changing the gap distance between the single-mode fiber and the microball lens within the packaged surgical needle catheter without using an additional beam expander having a fixed length. The probe successfully acquired crosssectional images of ocular tissues from an animal sample with the proposed miniaturized imaging probe.
基金the National Science Foundation for Excellent Young Scholars of China(21922815)the National Natural Science Foundation of China(22179139)+2 种基金the National Key Research and Development Program of China(2020YFB1505800)the Youth Innovation Promotion Association of CAS(2019178)the“Transformational Technologies for Clean Energy and Demonstration”Strategic Priority Research Program of the CAS(XDA21000000)。
文摘N-doped porous carbon has been extensively investigated for broad electrochemical applications.The performance is significantly impacted by the electrochemical double layer(EDL),which is material dependent and hard to characterize.Limited understanding of doping-derived EDL structure hinders insight into the structure-performance relations and the rational design of high-performance materials.Thus,we analyzed the mass and chemical composition variation of EDL within electrochemical operation by electrochemical quartz crystal microbalance,in-situ X-ray photoelectron spectroscopy,and time-offlight secondary ion mass spectrometry.We found that N-doping triggers specifically adsorbed propylene carbonate solvent in the inner Helmholtz plane(IHP),which prevents ion rearrangement and enhances the migration of cations.However,this specific adsorption accelerated solvent decomposition,rendering rapid performance degradation in practical devices.This work reveals that the surface chemistry of electrodes can cause specific adsorption of solvents and change the EDL structure,which complements the classical EDL theory and provide guidance for practical applications.
基金Project supported by the National High Technology Research and Developmem Program of China ~Grant No. 2013AA030901).
文摘We present a new polymer quartz piezoelectric crystal sensor that takes a quartz piezoelectric crystal as the basal material and a nanometer nonmetallic polymer thin film as the surface coating based on the principle of quartz crystal microbalance(QCM). The new sensor can be used to detect the characteristic materials of a volatile liquid. A mechanical model of the new sensor was built, whose structure was a thin circle plate composing of polytef/quartz piezoelectric/polytef. The mechanical model had a diameter of 8 mm and a thickness of 170 μm. The vibration state of the model was simulated by software ANSYS after the physical parameters and the boundary condition of the new sensor were set. According to the results of experiments, we set up a frequency range from 9.995850 MHz to 9.997225 MHz, 17 kinds of frequencies and modes of vibration were obtained within this range. We found a special frequency fspof 9.996358 MHz. When the resonant frequency of the new sensor's mechanical model reached the special frequency, a special phenomenon occurred. In this case, the amplitude of the center point O on the mechanical model reached the maximum value. At the same time, the minimum absolute difference between the simulated frequency based on the ANSYS software and the experimental measured stable frequency was reached. The research showed that the design of the new polymer quartz piezoelectric crystal sensor perfectly conforms to the principle of QCM. A special frequency value fspwas found and subsequently became one of the most important parameters in the new sensor design.
基金Supported by National Natural Science Foundation of China,No.81371885
文摘A biosensor is an analytical device used for the detection of analytes,which combines a biological component with a physicochemical detector.Recently,an increasing number of biosensors have been used in clinical research,for example,the blood glucose biosensor.This review focuses on the current state of biosensor research with respect to efficient,specific and rapid detection of hepatitis B virus(HBV).The biosensors developed based on different techniques,including optical methods(e.g.,surface plasmon resonance),acoustic wave technologies(e.g.,quartz crystal microbalance),electrochemistry(amperometry,voltammetry and impedance) and novel nanotechnology,are also discussed.
基金Project supported by the National Natural Science Foundation of China(Grant No.51905032)the National Key Research and Development Program of China(Grant No.2018YFC0810500)the Fundamental Research Funds for the Central Universities,China(Grant No.FRF-TP-18-012A2).
文摘The influence rules of square micro-pillar array porosity on the liquid motion characteristics of the near-surface layer are investigated by quartz crystal microbalance(QCM).QCM is a powerful and promising technique in studying the interfacial behavior,which exhibits great advantages in investigating the effects of surface microstructure,roughness,and array.In our experiments,three different arrays with the same height of about 280 nm and center distance of 200μm,but different diameters of about 78μm,139μm,and 179μm are investigated.The results indicate that when the surface array has a large porosity,its influence on the liquid motion of the near surface layer is slight,thus resulting in a small increase of half-bandwidth variation due to the additional friction energy dissipation.When the surface array has a small porosity,the array tends to make the liquid film trapped in the array oscillating with the substrate,then there may be a layer of liquid film behaving like rigid film,and it also will make the liquid motion near the array layer more complicated.Thus for the#3 surface with a small porosity,both the absolute values of frequency shift|Δf3|and half-bandwidth variationΔΓ3 increase obviously.The experimental results show good consistence with the theoretical model of Daikhin and Urbakh.This study sheds light on understanding the influence mechanism of surface array porosity on the liquid motion of near-surface layer.
基金Supported by the National High-Tech Research and Development Program of China(No.2007AA10Z301) the National Natural Science Foundation of China for Distinguished Young Scholars(No.50625309)
文摘Porphyrin-filled nanofibrous membranes were facilely prepared by electrospinning of the mixtures of poly(acrylonitrile-co-acrylic acid)(PANCAA) and porphyrins. 5,10,15,20-Tetraphenylporphyrin(TPP) and its metal-loderivatives(ZnTPP and CuTPP) were studied as filling mediators for the immobilization of redox enzyme. Results indicate that the introduction of TPP, ZnTPP and CuTPP improves the retention activity of the immobilized catalase. Among these three porphyrins, the ZnTPP-filled PANCAA nanofibrous membrane exhibits an activity retention of 93%, which is an exciting improvement. This improvement is attributed to both the strong catalase-porphyrin affinity and the possible facilitated electron transfer induced by the porphyrin as evidenced by quartz crystal microbalance (QCM) and fluorescence spectroscopy studies.
文摘In this study, we have used a direct immunoassay where the simple binding between antigen and an antibody is detected. Immunoassays were performed in a drop system, monitoring the frequency decrease of the quartz-crystal microbalance device because of mass increasing during immunoreaction. The QCM sensor was coated on both sides by gold electrodes, only one side of the crystal (liquid side) was in contact with the solution;the other side (contact side) was always dry. We tested a piezoelectric immunosensor for aflatoxin B1 (AFLA-B1) mycotoxin detection through the immo- bilization of DSP-anti-AFLAB1 antibody (AFLA-B1-Ab anti AFLAB1) on gold-coated quartz crystals (AT-cut/5 MHz). The DSP (3,3’-Dithiodipropionic-acid-di-N-hydroxysuccinimide ester) was used for the covalent attachment of the proteins. The piezoelectric crystal electrodes were pretreated by DSP for 15 min, rinsed with water and dried in a gentle flow of nitrogen gas. Then the DSP-coated crystals were installed in a sample holder and exposed to the anti-AFLAB1 antibody and to the AFLA-BI. Frequency and resistance shifts (Δf and ΔR) were measured simultaneously. Δf versus AFLA-BI concentrations in the range of 0.5 - 10 ppb exhibited a perfect linear correlation with a coefficient of above 0.998.
基金supported by the National Natural Science Foundation of China,No. 30973058,81171694Jiangsu Province Natural Science Foundation,No. BE2010743+2 种基金Jiangsu Graduate Student Innovation Project,No.CXZZ11_0721the Program for Development of Innovative Research Team in the First Affiliated Hospital of Nanjing Medical University,No. IRT-015a Project Funded by the Priority Academic Program Development of Jiangsu Higher Education Institutions
文摘The fast and accurate identification of nerve tracts is critical for successful nerve anastomosis. Taking advantage of differences in acetylcholinesterase content between the spinal ventral and dorsal roots, we developed a novel quartz crystal microbalance method to distinguish between these nerves based on acetylcholinesterase antibody reactivity. The acetylcholinesterase antibody was immobilized on the electrode surface of a quartz crystal microbalance and reacted with the acetylcholinesterase in sample solution. The formed antigen and antibody complexes added to the mass of the electrode inducing a change in frequency of the electrode. The spinal ventral and dorsal roots were distinguished by the change in frequency. The ventral and dorsal roots were cut into 1 to 2-mm long segments and then soaked in 250 pL PBS. Acetylcholinesterase antibody was immobilized on the quartz crystal microbalance gold electrode surface. The results revealed that in 10 minutes, both spinal ventral and dorsal roots induced a frequency change; however, the frequency change induced by the ventral roots was notably higher than that induced by the dorsal roots. No change was induced by bovine serum albumin or PBS. These results clearly demonstrate that a quartz crystal microbalance sensor can be used as a rapid, highly sensitive and accurate detection tool for the quick identification of spinal nerve roots intraoperatively.
基金the PetroChina for its financial support (Grant number: 2011B-2503-2)
文摘On the basis of thin film lubrication theory, the influence of fluid film(disordered film), ordered film and adsorbed film on tribological behavior of lubricating oil in thin-film lubrication(TFL) regime was studied. The μ-L(friction coefficient versus load) curves of different oil viscosity and additive dosage were obtained by a high frequency reciprocating test rig and the adsorption capacity of additive on steel surface were measured by QCM-D. Based on the Stribeck curve and thin film lubrication theory model, some conclusions can be drawn up, namely:(1) The μ-L curves and the parameters of L0 and μ0, obtained from the high frequency reciprocating test rig with ball-disc contact, can be used to study tribological behaviors of lubricating oil under TFL conditions.(2) In comparison with the high viscosity base fluid, the lower one can enter into TFL regime under lower load and keeps a lower friction coefficient in TFL regime.(3) The polar molecules in additive formulation produce ordered adsorbed layer on steel surface to reduce friction coefficient. And in TFL regime, the molecule's polarity, layer thickness and saturation degree on steel surface probably can influence lubricant's tribological behaviors between the moving interfaces. Moreover, the further study would be focused on the competitive adsorption of different additives, the formation of dual- and/or tri-molecular adsorption layers, and other aspects.
文摘A dichlorosilane gas and a trichlorosilane gas in ambient hydrogen were evaluated to show their different gas flow motions in a slim vertical cold wall chemical vapor deposition reactor for the Minimal Fab system. This evaluation was performed for improving and controlling the film qualities and the productivities, using two quartz crystal microbalances (QCM) installed at the </span><span style="font-family:Verdana;">inlet and exhaust of the chamber by taking into account that the QCM frequency corresponds to the real time changes in the gas properties.</span><span style="font-family:Verdana;"> Typically, the time period approaching from the inlet to the exhaust was shorter for the trichlorosilane gas than that for the dichlorosilane gas. The trichlorosilane gas was shown to move like plug flow, while the dichlorosilane gas seemed to be well mixed in the entire chamber.
基金Funded by the National Natural Science Foundation of China(No.31570958)Science and Technology Support Program of Sichuan Province(No.2016SZ0007)
文摘The effects of surface adsorption of bovine serum albumin(BSA) and human gamma-globulin(HGG) on the tribological performance of a DLC film were investigated using a quartz crystal microbalance with dissipation(QCM-D), a ball-on-disk reciprocating tribometer, and a three-electrode electrochemical cell. The results showed that the wear depth in the BSA solution was higher than that in the HGG solution. In the HGG solution, the HGG-adsorbed layer could act as a lubricating layer and protect the DLC film from wear. The wear volume of DLC film in BSA and HGG mixture solution was higher than that in single HGG solution. This may be because the BSA molecules inhibit the formation of HGG adsorbed layer during sliding.
基金Supported by the Jiangsu High-tech Project(BG2006038)
文摘A quartz crystal microbalance (QCM) is used to determine the phase equilibrium of paclitaxel-carbon dioxide system in the pressure range of 0-11 MPa and at temperatures of 35 °C,40 °C and 45 °C.The experimental results indicated that gaseous CO2 could be absorbed poorly into paclitaxel.The swelling of paclitaxel film in CO2 was observed before paclitaxel dissolved into supercritical carbon dioxide (ScCO2) with the increase of pressure.It was found that ScCO2 was not a good solvent for paclitaxel.The mole fraction of paclitaxel in ScCO2 was in the range of (4.5×10-9)-(7.8×10-9) under all our experimental conditions.Therefore,a much higher pressure than the CO2 supercritical point and/or a cosolvent must be used in any processes wherever paclitaxel dissolution in ScCO2 is required.
文摘A new method of determination of trace CNin water was proposed.A thin film of AgS was electrochemically deposited on both sides of a silver coated piezoelectric crystal.The AgS Ag films can react with CN selectively,which causes the frequency shifts of the piezoelectric crystal.The frequency shifts are proportional to the concentration of CN in the range of 106~10'g/L.XPS experiments indicated the sensing film was AgiS Ag.A coordination complex Ag-CNwas formed when AgiS Ag film contacted with solution containing CNion.A response mechanism was proposed based on the XPS data.
基金Supported by the Science Foundation for Young Teachers of Northeast Normal University,China(No.20081001)
文摘The in situ electrochemical quartz crystal microbalance(EQCM) technique was used to investigate the ion transport of immobilized heteropolyanions at a self-assembled monolayer(SAM) modified gold electrode during electrochemical redox process.A mixed transfer method was presented to analyse the abnormal change of resonant frequency based on the simultaneous insertion/extraction of different ions.The results indicate that the migration of HSO4-anions was indispensable in the redox process of the heteropolyanions in a 1 mol/L H2SO4 solution and played a key role in the abnormal change of the resonant frequency.Such a change was attributed to different packing densities derived by means of differently immobilized methods.
基金This work was supported by the National Natural Science Foundation of China (No.20474060).
文摘The effect of salt concentration on layer-by-layer deposition of poly(sodium 4-styrene sulfonate) (PSSS)/poly(vinylbenzyl trimethylammonium chloride) (PVTC) was investigated by use of quartz crystal microbalance with dissipation (QCM-D). The changes in frequency and dissipation demonstrate that the addition of NaC1 leads the thickness of PSSS/PVTC multilayer to increase. The deposition of PSSS/PVTC is dominated by surface charge overcompensation level at lower salt concentrations. However, it is mainly determined by the interpenetration of polyelectrolytes at a higher salt concentration, as reflected in the oscillation of dissipation change.
基金Supported by the Guangdong Science and Technology Key Projects, China(Nos.2007A010700001, 2007B090400032)Guangzhou Science and Technology Key Projects, China(Nos.2007Z1-D0051, SKT[2007]17-11) the Scientific Research Foundation for Young Teachers of the Sun Yat-Sen University, China(No.2006-31000-1131214)
文摘Pd was electrochemically deposited on gold-coated quartz crystals at nanogram-level. The coulombic efficiency and initial nucleation and growth mechanism of potentiostatic Pd deposition were investigated via in situ electrochemical quartz crystal microbalance(EQCM). The coulombic efficieneies are 84%, 93% and 95% for Pd deposition at 0.3, 0.2 and 0.1 V(vs. SCE), respectively. The results of chronoamperometric measurements show that the Pd deposition proceeded by an instantaneous nucleation(at 0.3 V) or progressive nucleation(at 0.2 and 0.1 V) in a three-dimensional(3D) growth mode. The catalytic activity of Pd-based electrocatalyst for ethanol oxidation was characterized in an alkaline solution. It was found that the highest mass activity for ethanol oxidation on Pd-based electrocatalyst is 1.8× 10^4 A/(g Pd) deposited at 0.3 V for 5 s.
基金supported by the National Natural Science Foundation of China(Grant No.61672094)
文摘The quartz crystal microbalance(QCM) is an important tool that can sense nanogram changes in mass. The hybrid temperature effect on a QCM resonator in aqueous solutions leads to unconvincing detection results. Control of the temperature effect is one of the keys when using the QCM for high precision measurements. Based on the Sauerbrey's and Kanazawa's theories, we proposed a method for enhancing the accuracy of the QCM measurement, which takes into account not only the thermal variations of viscosity and density but also the thermal behavior of the QCM resonator. We presented an improved Sauerbrey equation that can be used to effectively compensate the drift of the QCM resonator. These results will play a significant role when applying the QCM at the room temperature.
基金ACKNOWLEDGMENTS This work was supported by the National Natural Science Foundation of China (No.9732011CB606200 and No.81330031) and Fundamentat Research Funds for the Central Universities (No.SWJTU11CX054). The authors gratefully acknowledge assistance of Mr. Hai-bei Liu at Qsense company for consulting.
文摘The adsorption of fibrinogen can be used as a quick indicator of surface haemocompatibility because of its prominent role in coagulation and platelet adhesion. In this work the molecular interaction between fibrinogen and a modified titanium oxide surface/platelet has been studied by quartz crystal microbalanee with dissipation (QCM-D) in situ. In order to further characterize the conformation of adsorbed fibrinogen, αC and γ-chain antibody were used to check the orientation and denaturation of fibrinogen on solid surface. QCM-D investiga- tions revealed the fibrinogen have the trend to adsorb on hydropllilic surface in a side-on orientation by positively charged αC domains, which would reduce the exposure of platelet bonding site on γ chain and enable less platelet adhesion and be activated. These obser- vations suggest that certain conformations of adsorbed fibrinogen are less platelet adhesive than others, which opens a possibility for creating a non-platelet adhesive substrates.