期刊文献+
共找到8篇文章
< 1 >
每页显示 20 50 100
Changes of Porosity and Roughness of Concrete Surfaces Due to Microbial Corrosion
1
作者 Vlasta Ondrejka Harbulakova Alena Luptakova +1 位作者 Adriana Estokova Nadezda Stevulowa 《Journal of Chemistry and Chemical Engineering》 2011年第3期241-245,共5页
The issue of the building materials biocorrosion has a significant economic dimension because it results in the costly repair. The start and the course of corrosion are conditioned by many factors which undoubtedly in... The issue of the building materials biocorrosion has a significant economic dimension because it results in the costly repair. The start and the course of corrosion are conditioned by many factors which undoubtedly include biological effects like the influence of vegetation and microorganisms causing the so called microbial corrosion. Microorganisms have also a considerable share in the decay and degradation of different building materials. The activity of sulphuratum is the keystone of many processes in nature and in industry. The sulphuric bacteria oxidize hydrogen sulphide produced by sulphate-reducing bacteria into sulphuric acid resulting in the acid or sulphate corrosion of cement stone. The paper is aimed on evaluation of porosity and roughness of concrete samples surface as elementary characteristics of microbial corrosion. After 4 months exposure to the real conditions in sewers deposition the changes were observed by confocal laser microscopy and consequently analyzed and interpreted. 展开更多
关键词 POROSITY ROUGHNESS CONCRETE microbial corrosion.
下载PDF
Microbial communities present on mooring chain steels with different copper contents and corrosion rates 被引量:1
2
作者 WU Jiajia GAO Jieyan +5 位作者 ZHANG Dun TAN Faqi YIN Jiang WANG Yu SUN Yan LI Ee 《Journal of Oceanology and Limnology》 SCIE CAS CSCD 2020年第2期378-394,共17页
Copper has long been utilized as a disinfectant for bacteria,but its impact on microbial communities attached to the steel surface in seawater remains unknown.In the present study,3 mooring chain steels of different c... Copper has long been utilized as a disinfectant for bacteria,but its impact on microbial communities attached to the steel surface in seawater remains unknown.In the present study,3 mooring chain steels of different copper contents are subjected to a 3-month marine field exposure,and the corrosion rate increases in the order of BR5 steel(without copper)<BR5 CuH steel(0.8%copper)<BR5 CuL steel(0.4%copper).The microbial community results show that copper introduction does not result in an obvious change in microbial quantity,but it alters the diversity,richness,and structure of microbial communities due to the variation in copper-resistance of different species.BR5 CuH steel holds microbial communities with the highest percentage of some well-known corrosive microbes including sulfate-reducing bacteria,sulfuroxidizing bacteria,and iron-oxidizing bacteria,but possesses the lowest community diversity/richness owing to the toxicity of copper.The microbial community diversity/richness is stimulated by the low-copper content of BR5 CuL steel,and this steel also carries an intermediate proportion of such corrosive bacteria.Both well-known corrosive bacteria and microbial community diversity/richness seem to be involved in the corrosion acceleration of copper-bearing mooring chain steels. 展开更多
关键词 marine corrosion microbially influenced corrosion microbial community mooring chain steel copper introduction
下载PDF
Elucidating microbial iron corrosion mechanisms with a hydrogenase-deficient strain of Desulfovibrio vulgaris
3
作者 Di Wang Toshiyuki Ueki +2 位作者 Peiyu Ma Dake Xu Derek R.Lovley 《mLife》 CSCD 2024年第2期269-276,共8页
Sulfate-reducing microorganisms extensively contribute to the corrosion of ferrous metal infrastructure.There is substantial debate over their corrosion mechanisms.We investigated Fe^(0) corrosion with Desulfovibrio v... Sulfate-reducing microorganisms extensively contribute to the corrosion of ferrous metal infrastructure.There is substantial debate over their corrosion mechanisms.We investigated Fe^(0) corrosion with Desulfovibrio vulgaris,the sulfate reducer most often employed in corrosion studies.Cultures were grown with both lactate and Fe^(0) as potential electron donors to replicate the common environmental condition in which organic substrates help fuel the growth of corrosive microbes.Fe^(0) was corroded in cultures of a D.vulgaris hydrogenase-deficient mutant with the 1:1 correspondence between Fe^(0) loss and H_(2) accumulation expected for Fe^(0) oxidation coupled to H+reduction to H_(2).This result and the extent of sulfate reduction indicated that D.vulgaris was not capable of direct Fe^(0)-to-microbe electron transfer even though it was provided with a supplementary energy source in the presence of abundant ferrous sulfide.Corrosion in the hydrogenase-deficient mutant cultures was greater than in sterile controls,demonstrating that H_(2) removal was not necessary for the enhanced corrosion observed in the presence of microbes.The parental H_(2)-consuming strain corroded more Fe^(0) than the mutant strain,which could be attributed to H_(2) oxidation coupled to sulfate reduction,producing sulfide that further stimulated Fe^(0) oxidation.The results suggest that H_(2) consumption is not necessary for microbially enhanced corrosion,but H_(2) oxidation can indirectly promote corrosion by increasing sulfide generation from sulfate reduction.The finding that D.vulgaris was incapable of direct electron uptake from Fe^(0) reaffirms that direct metal-to-microbe electron transfer has yet to be rigorously described in sulfate-reducing microbes. 展开更多
关键词 electrobiocorrosion electron transfer hydrogen transfer microbial corrosion sulfate-reducing microbes
原文传递
Effect of Electrodeposition Methods of Cuprous Oxide on Antibacterial Properties of Concrete
4
作者 徐怡 XU Ning +5 位作者 GUO Mingzhi LUO Jie LI Yi 储洪强 ZENG Youxu JIANG Linhua 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS CSCD 2023年第4期823-833,共11页
Three types of electrodeposition,DC electrodeposition,low-frequency pulsed electrodeposition and high-frequency pulsed electrodeposition,were used to deposit cuprous oxide on the concrete surface to improve the antiba... Three types of electrodeposition,DC electrodeposition,low-frequency pulsed electrodeposition and high-frequency pulsed electrodeposition,were used to deposit cuprous oxide on the concrete surface to improve the antibacterial properties of concrete.The effects of pulse deposition frequency on the antibacterial property of concrete were studied using sulfate-reducing bacteria(SRB)and Escherichia coli(E.coli)as model bacteria.The bacterial concentration and the antibacterial rate were measured to evaluate the antibacterial performance of concrete.The effects of different deposition methods on the elemental content of copper and the amount of copper ions exuded were studied.XRD and SEM were used to analyze the microstructure of the deposited layers.The experimental results show that the concrete treated by electrodeposition exhibited good antibacterial properties against SRB and E.coli.The antibacterial effect of cuprous oxide deposited on concrete by pulse method was better than that by direct current(DC)method.The antibacterial rate of concrete was positively correlated with the exudation rate of copper ion.As the pulse frequency increased,the deposits content on the surface was increased with an accompanying improvement in the antibacterial property.Besides,the pulsed current had an indiscernible effect on the composition of the sediments,which were all mainly composed of Cu_(2)O,but the morphology of the Cu_(2)O differed greatly.Cubic octahedral cuprous oxide had better antibacterial properties with the highest copper ion leaching rate compared with cubic and spherical cuprous oxide. 展开更多
关键词 cuprous oxide electrodeposition mode microbial corrosion antibacterial properties
下载PDF
Effect of cathode protection on Desulfovibrio desulfuricans corrosion of X80 steel in a marine tidal environment
5
作者 ZHOU Xiao-bao WANG Zi-hao +4 位作者 OU-YANG Ze-lun SU Hui WANG Yong LI Zhi WU Tang-qing 《Journal of Central South University》 SCIE EI CAS 2024年第10期3612-3627,共16页
The study systematically investigated the impact of zinc sacrificial anode(Zn-SA)cathode protection on the corrosion of X80 steel caused by Desulfovibrio desulfuricans(D.desulfuricans)in a marine tidal environment.Uti... The study systematically investigated the impact of zinc sacrificial anode(Zn-SA)cathode protection on the corrosion of X80 steel caused by Desulfovibrio desulfuricans(D.desulfuricans)in a marine tidal environment.Utilizing weight-loss analysis,electrochemical measurements,Raman spectroscopy,and 3D morphology microscopy,the research unveiled significant findings.Unprotected steel suffered pronounced localized corrosion in the presence of D.desulfuricans in the marine tidal environment.However,the implementation of Zn-SA cathode protection notably reduced the activity of both planktonic and sessile D.desulfuricans cells.Over time,the accumulation of calcareous deposits within the corrosion products increased,as evidenced by a rise in the resistance of the corrosion produt film(Rf).Remarkably,Zn-SA cathode protection demonstrated substantial inhibition of the steel’s corrosion rate,albeit exhibiting reduced efficiency as the vertical height of the steel within the tidal environment increased. 展开更多
关键词 X80 pipeline steel microbial corrosion marine tidal corrosion Desulfovibro desulfuricans cathode protection
下载PDF
Efficacy of natural biocide on control of microbial induced corrosion in oil pipelines mediated by Desulfovibrio vulgaris and Desulfovibrio gigas 被引量:2
6
作者 Meeta Lavania Priyangshu M.Sarma +2 位作者 Ajoy K.Mandal Simrita Cheema Banwari Lal 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2011年第8期1394-1402,共9页
We compared the efficacy of a natural biocide with four chemical tetrakishydroxymethyl phosphonium sulfonate, benzyl trimethyl ammonium chloride, and formaldehyde, glutaraldehyde, to control microbial induced corrosio... We compared the efficacy of a natural biocide with four chemical tetrakishydroxymethyl phosphonium sulfonate, benzyl trimethyl ammonium chloride, and formaldehyde, glutaraldehyde, to control microbial induced corrosion in oil pipelines. The efficacy of biocides were monitored against Desulfovibrio vulgaris and Desulfovibrio gigas in experimental pipes by measuring cell counts, H2S production, Fe(II) production, production of extracellular polymeric substances and structure of biofilm. The treatment with cow urine had minimum planktonic cell counts of 3 x 102 CFU/mL as well as biofilm cell counts of 9 x 101 CFU/mL as compared with tetrakishydroxyl methyl phosphonium sulfonate, benzyl trimethyl ammonium chloride, formaldehyde and glutaraldehyde. Sulfide production was the lowest with cow urine (0.08 mmol]L), followed by tetrakishydroxymethyl phosphonium sulfonate 0.72 mmol]L. On day 90 of treatment, Fe(II) production was also found to be the lowest with cow urine. The scanning electron microscopic studies indicated that the biofilm bacteria were killed by cow urine. These results demonstrate the cow urine mediated control of microbially induced corrosion, and this is indicative of its potential as a viable substitute of toxic biocides. To the best of our knowledge, this seems to be the first report which screens possible biocidal activity by cow urine as compared to the most common bioeides which oil industry is currently using. 展开更多
关键词 microbially induced corrosion BIOCIDE BIOFILM extraploymeric substances H2S production Fe(II) production
原文传递
Effect of organic silicon quaternary ammonium salts on mitigating corrosion of reinforced steel induced by SRB in mild alkaline simulated concrete pore solution 被引量:5
7
作者 Ini-Ibehe Nabuk Etim Junhua Dong +6 位作者 Jie Wei Chen Nan Durga Bhakt Pokharel Aniefiok Joseph Umoh Dake Xu Mingzhong Su Wei Ke 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2021年第5期126-140,共15页
The corrosion damage of 20 SiMn steel by sulphate-reducing bacteria(SRB)and the mitigation effect of organic silicon quaternary ammonium salt(OSA)were studied in sterilized mild alkaline simulated concrete pore soluti... The corrosion damage of 20 SiMn steel by sulphate-reducing bacteria(SRB)and the mitigation effect of organic silicon quaternary ammonium salt(OSA)were studied in sterilized mild alkaline simulated concrete pore solution(STR)with different additions of SRB and OSA at pH 9.35 for 28 days.Uniform corrosion occurs in STR medium while slight localized corrosion is observed in STR+OSA medium,and localized pitting corrosion occurs in STR+SRB and STR+SRB+OSA media.The largest pit depth reduces from 36.70μm in STR+SRB medium to 3.31μm in STR+SRB+OSA medium due to the mitigation effect of OSA.The corrosion rate reflected by weight loss and electrochemical impedance spectroscopy(EIS)results presents the order of STR<STR+OSA<STR+SRB+OSA<STR+SRB,which also proves that the presence of SRB can accelerate corrosion in a carbonated medium.However,OSA as an efficient bacteriostatic agent can reduce the excessive growth of SRB and thus reduce corrosion. 展开更多
关键词 Steel reinforced concrete microbial corrosion BIOCIDE EIS
原文传递
Valorisation of alum sludge to produce green and durable mortar 被引量:1
8
作者 Qiong Jia Yan Zhuge +4 位作者 Weiwei Duan Yue Liu Jing Yang Osama Youssf Jinsuo Lu 《Waste Disposal and Sustainable Energy》 2022年第4期283-295,共13页
Alum sludge is a typical by-product of drinking water treatment processes.Most sludge is disposed of at landfill sites,and such a disposal method may cause significant environmental concern due to its vast amount.This... Alum sludge is a typical by-product of drinking water treatment processes.Most sludge is disposed of at landfill sites,and such a disposal method may cause significant environmental concern due to its vast amount.This paper assessed the feasibility of reusing sludge as a supplementary cementitious material,which could efficiently exhaust stockpiled sludge.Specifically,the pozzolanic reactivity of sludge at different temperatures,the reaction mechanism of the sludge-cement binder,and the resistance of sludge-derived mortar to microbially induced corrosion were investigated.The obtained results indicated that 800℃ was the optimal calcination temperature for sludge.Mortar containing sludge up to 30%by weight showed comparable physical properties at a curing age of 90 days.Mortar with 10%cement replaced by sludge can significantly improve the resistance to biogenic corrosion due to the formation of Al-bearing phases with high resistance to acidic media,e.g.,Ca_(4)Al_(2)O_(7)·xH_(2)O and strätlingite. 展开更多
关键词 Alum sludge Pozzolanic activity microbially induced corrosion Cement-based composites Utilisation of waste
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部