A new distribution principle of bus protection is presented.The protection system description,its design features,hardware structure,construction of data communication network are given.Dynamic simulation experiments ...A new distribution principle of bus protection is presented.The protection system description,its design features,hardware structure,construction of data communication network are given.Dynamic simulation experiments show its distinguishing advantages over traditional centralized principle.展开更多
It has been recognized recently that when injecting renewable energy source power to a load bus which connected to a distributed feeder in a power grid system, a stability problem occurs particularly when having high ...It has been recognized recently that when injecting renewable energy source power to a load bus which connected to a distributed feeder in a power grid system, a stability problem occurs particularly when having high fault duties that exceeding the circuit breaker ratings at some substations. In this paper an analysis of power flow, short circuit, stability and protection is given in detail to an example of limited 7-bus power grid system. Comparison is illustrated between power grid with and without distributed generators regarding bus voltages, fault currents, critical power angles, selected current transformers and over current relay settings in each bus.展开更多
This paper introduces a new complex percentage differential relay for bus protection. It allows greater CT errors during the external fault and is still sensitive to the intemal fault with high fault resistance or out...This paper introduces a new complex percentage differential relay for bus protection. It allows greater CT errors during the external fault and is still sensitive to the intemal fault with high fault resistance or out-flowing current.The CTs of the differential circuit of the new relay may have different transformation ratio, so the new relay can share CTs with other relays and don’t need special CTs only for differential protection. It may be applied in transformer differential protection as well.展开更多
文摘A new distribution principle of bus protection is presented.The protection system description,its design features,hardware structure,construction of data communication network are given.Dynamic simulation experiments show its distinguishing advantages over traditional centralized principle.
文摘It has been recognized recently that when injecting renewable energy source power to a load bus which connected to a distributed feeder in a power grid system, a stability problem occurs particularly when having high fault duties that exceeding the circuit breaker ratings at some substations. In this paper an analysis of power flow, short circuit, stability and protection is given in detail to an example of limited 7-bus power grid system. Comparison is illustrated between power grid with and without distributed generators regarding bus voltages, fault currents, critical power angles, selected current transformers and over current relay settings in each bus.
文摘This paper introduces a new complex percentage differential relay for bus protection. It allows greater CT errors during the external fault and is still sensitive to the intemal fault with high fault resistance or out-flowing current.The CTs of the differential circuit of the new relay may have different transformation ratio, so the new relay can share CTs with other relays and don’t need special CTs only for differential protection. It may be applied in transformer differential protection as well.