期刊文献+
共找到4,914篇文章
< 1 2 246 >
每页显示 20 50 100
Research on the longitudinal protection of a through-type cophase traction direct power supply system based on the empirical wavelet transform
1
作者 Lu Li Zeduan Zhang +5 位作者 Wang Cai Qikang Zhuang Guihong Bi Jian Deng Shilong Chen Xiaorui Kan 《Global Energy Interconnection》 EI CSCD 2024年第2期206-216,共11页
This paper proposes a longitudinal protection scheme utilizing empirical wavelet transform(EWT)for a through-type cophase traction direct power supply system,where both sides of a traction network line exhibit a disti... This paper proposes a longitudinal protection scheme utilizing empirical wavelet transform(EWT)for a through-type cophase traction direct power supply system,where both sides of a traction network line exhibit a distinctive boundary structure.This approach capitalizes on the boundary’s capacity to attenuate the high-frequency component of fault signals,resulting in a variation in the high-frequency transient energy ratio when faults occur inside or outside the line.During internal line faults,the high-frequency transient energy at the checkpoints located at both ends surpasses that of its neighboring lines.Conversely,for faults external to the line,the energy is lower compared to adjacent lines.EWT is employed to decompose the collected fault current signals,allowing access to the high-frequency transient energy.The longitudinal protection for the traction network line is established based on disparities between both ends of the traction network line and the high-frequency transient energy on either side of the boundary.Moreover,simulation verification through experimental results demonstrates the effectiveness of the proposed protection scheme across various initial fault angles,distances to faults,and fault transition resistances. 展开更多
关键词 Through-type Cophase traction direct power supply system Traction network Empirical wavelet transform(EWT) Longitudinal protection
下载PDF
Transformation of Modern Chinese Architectural Form and Its Influence on the Protection of Contemporary Chinese Architectural Heritage
2
作者 LIU Yufan HU Shen ZHANG Kang 《Journal of Landscape Research》 2023年第2期68-70,共3页
Architecture is a fascinating and complex mixture of cultural practices.Different cultures are intertwined to form a new system.The relationship between Chinese native architecture and Western construction methods in ... Architecture is a fascinating and complex mixture of cultural practices.Different cultures are intertwined to form a new system.The relationship between Chinese native architecture and Western construction methods in the development of Chinese construction from 1840 to 1937 is inspected.Based on Chinese and British sources,special attention is paid to building materials and different aspects of the building process.The research shows that the complex interaction in shaping Chinese architecture has led to a new style and a new construction method,which combines the characteristics of two systems in material supply and use,construction technology,builder organization,tools used and the education received.In the construction and protection related to integration and conflict,the development of contemporary China's emerging construction protection industry is similar to the history of modern Chinese architecture. 展开更多
关键词 transformATION China Building technology Building protection HERITAGE
下载PDF
Research on the Reason for Transformer Differential Protection Mal-operation Caused by Sympathetic Inrush
3
作者 Xiangfei Sun Hongchun Shu Jianping Zhou 《Energy and Power Engineering》 2013年第4期1077-1082,共6页
The paper is concerned with whether CT transient saturation, which caused by sympathetic inrush, is the direct reason for mal-operation of transformer differential relays. In order to analyze transforming characterist... The paper is concerned with whether CT transient saturation, which caused by sympathetic inrush, is the direct reason for mal-operation of transformer differential relays. In order to analyze transforming characteristics of saturated CT, the gain of each harmonic current transforming from primary winding to secondary winding of transient saturation CT is calculated. Based on the fact that series sympathetic inrush is easier to lead differential relay mal-operation than parallel sympathetic inrush, the effect of CT saturation on differential relay?in the case of both parallel sympathetic inrush and series sympathetic inrush are investigated respectively. Theory analysis and simulation show that higher harmonic will be transferred by saturated CT more easily than lower harmonic, and then the second harmonic proportion of CT secondary side is higher than that of CT primary side. Thus CT transient saturation itself is not essential reason for differential relay mal-operation. Parallel sympathetic inrush and series sympathetic inrush will lead to different location CT saturated. Parallel sympathetic inrush will lead to CT located system side saturated;second harmonic ratio of differential current increase and dead angle is large. Series sympathetic inrush will lead to CT located load side saturated;second harmonic ratio of differential current decrease and dead angle is small. 展开更多
关键词 SYMPATHETIC Inrush CT TRANSIENT SATURATION transformer Differential protection
下载PDF
Research on the Differential Protection Algorithm of Multi-Tap Special Transformer
4
作者 Mingyu Huang Liang Dong +2 位作者 Jun Zhang Jun Wang Zhiguo Hao 《Journal of Power and Energy Engineering》 2014年第9期98-105,共8页
Compared with conventional transformers, the rectiformer is special in connection mode, which is multi-tap and not equipped with the differential protection. In this paper, the differential protection algorithm for Mu... Compared with conventional transformers, the rectiformer is special in connection mode, which is multi-tap and not equipped with the differential protection. In this paper, the differential protection algorithm for Multi-tap special transformer was derived. The regulating methods for the rectiformer were studied first, and then the rectiformer model of one electrolytic aluminium plant was built by PSCAD/EMTDC, characteristics of the rectiformer bank were also analyzed. The algorithm was derived on the basis of the per-unit system, and the processing methods of the regulating transformer’s tap position information were proposed. Finally, a contrast of differential protection algorithm between the multi-tap special transformer and the conventional transformer was made. 展开更多
关键词 DIFFERENTIAL protection SPECIAL transformerS MULTI-TAP Electrolytic ALUMINUM
下载PDF
Study on the Effect of Multi-Type Current Transformers Hybrid Operation on Differential Protection of the Bus Based on Dynamic Simulation
5
作者 Wenbiao Liao Zexin Zhou +2 位作者 Rongrong Zhan Yanjun Li Zhengguang Chen 《Energy and Power Engineering》 2017年第4期1-11,共11页
This paper analyzes characteristics of multi type current transformers hybrid operation for each branch of the bus and their effects on differential protection of the bus. By theoretically analyzing transmission chara... This paper analyzes characteristics of multi type current transformers hybrid operation for each branch of the bus and their effects on differential protection of the bus. By theoretically analyzing transmission characteristics of multi type current transformers and their influence factors, we study the dynamic model testing method of multi type current transformers for the bus, and design 3 kinds of testing schemes by making the equivalent model based on the field of P-level current transformer, TPY-level current transformer and electronic current transformer, and build the hybrid operation testing platform of multi type current transformers. Finally, we compare and analyze the transmission characteristics difference of multi type current transformers on the same branch and the characteristics difference of hybrid operation in two successive external faults, analyze the cause behind the differences, and put forward the corresponding improvement measures. 展开更多
关键词 DIFFERENTIAL protection of the BUS Multi-Type Current transformer Hybrid Operation DYNAMIC SIMULATION TEST Method DYNAMIC SIMULATION TEST Platform
下载PDF
Brief discussion on commissioning method of microcomputer-based transformer differential protection
6
《水电站机电技术》 2017年第9期84-84,共1页
关键词 transformer DIFFERENTIAL protection Commissioning METHOD Comer Calculation SIDE of DIFFERENTIAL protection
下载PDF
Research on transformer protection based on wavelet neural network and FPGA
7
作者 WANG Zhi-wen GONG Mao-fa AN Bin LI Lan-bing LIU Tao 《Journal of Measurement Science and Instrumentation》 CAS 2014年第2期76-79,共4页
本文在阐述变压器保护的重要性和分析励磁涌流产生条件的基础上,提出了一种基于小波神经网络算法识别励磁涌流的方法,大量的仿真结果表明,和应涌流和励磁电流无明显的不同。根据小波神经网络算法庞大的数据量和采样率,提出基于FPGA硬件... 本文在阐述变压器保护的重要性和分析励磁涌流产生条件的基础上,提出了一种基于小波神经网络算法识别励磁涌流的方法,大量的仿真结果表明,和应涌流和励磁电流无明显的不同。根据小波神经网络算法庞大的数据量和采样率,提出基于FPGA硬件来实现相应的算法。利用小波神经网络和FPGA技术,可以提高保护装置的实时处理速度和精度,该研究在进一步提高变压器的保护上具有较高的理论和实用价值。 展开更多
关键词 小波神经网络 电压器保护 FPGA DSP
下载PDF
Design of Transformer Magnetic Bias Protection Device in High Power Electronic Equipments
8
作者 Xi Lei Guizhi Xu Zhanfeng Deng 《Journal of Electrical Engineering》 2014年第2期75-81,共7页
关键词 电气控制 控制理论 电气测量 集中参数
下载PDF
A Testing Method for Ratio Restraint Characteristics of Differential Relay Protection of Transformers
9
作者 Cao Zhihui Peng Chunyan Zhou Huaping 《Electricity》 2012年第5期44-47,共4页
In this paper, a method to calculate the slope of the ratio restraint characteristic of a transformer differential relay protection is proposed. The method allows using some concise but effective means to get the slop... In this paper, a method to calculate the slope of the ratio restraint characteristic of a transformer differential relay protection is proposed. The method allows using some concise but effective means to get the slope. Modulating the argument of current output from ONLLY testing equipment can make the relay protection device operate, thus, the data used for calculation would be obtained naturally after several trails. In order to make sure how effective that method could be, some experiment data is given as well. 展开更多
关键词 变压器差动保护 比率制动特性 测试设备 继电保护装置 继电器保护 输出参数 调制电流 实验数据
下载PDF
A Double-Ended Protection Principle for an LCC-VSC-MTDC System with Strong Anti-Interference Ability
10
作者 ChuanjianWu Dahai Zhang Jinghan He 《Energy Engineering》 EI 2023年第2期299-316,共18页
The DC grid technology of multi-power supply and multi-drop-point power reception is an effective solution for large-scale renewable energy integration into the power grid.Line-commutated converter-Voltage source conv... The DC grid technology of multi-power supply and multi-drop-point power reception is an effective solution for large-scale renewable energy integration into the power grid.Line-commutated converter-Voltage source converter(LCC-VSC)power grids are one of the more important developmental directions of the future power grid that have occured in recent years.But the multi-terminal high voltage direct current system has the problems of inconsistent boundary characteristics,inconsistent control,and fault response characteristics,which puts higher requirements on the protection scheme.Thus,a completely new protection principle is proposed in this paper.Firstly,the fault characteristics of distributed capacitance current are analyzed.The reactive power calculated by the distribution parameters of different frequencies is different.Subsequently,the fault characteristics of DC reactive power are analyzed,and a DC reactive power extraction algorithm is proposed.The polarity of the multi-band DC reactive power is used to construct the protection scheme.Finally,the LCC-VSC power grid model verifies the correctness and superiority of the proposed protection scheme.The proposed scheme uses DC reactive power instead of fault current to solve the long delay problem caused by distributed capacitance.Compared with the prior art,the proposed solution is not affected by distributed capacitance and has a stronger anti-interference ability(600Ω+10 dB+1 ms). 展开更多
关键词 Hybrid DC transmission double-ended protection S transform Hilbert transform
下载PDF
A Protection Method of VSC-HVDC Cables Based on Generalized S-Transform 被引量:2
11
作者 Weishi Man Xiaoman Bei Zhiyu Zhang 《Energy and Power Engineering》 2021年第4期1-10,共10页
<div style="text-align:justify;"> Generalized S-transform is a time-frequency analysis method which has higher resolution than S-transform. It can precisely extract the time-amplitude characteristics o... <div style="text-align:justify;"> Generalized S-transform is a time-frequency analysis method which has higher resolution than S-transform. It can precisely extract the time-amplitude characteristics of different frequency components in the signal. In this paper, a novel protection method for VSC-HVDC (Voltage source converter based high voltage DC) based on Generalized S-transform is proposed. Firstly, extracting frequency component of fault current by Generalized S-transform and using mutation point of high frequency to determine the fault time. Secondly, using the zero-frequency component of fault current to eliminate disturbances. Finally, the polarity of sudden change currents in the two terminals is employed to discriminate the internal and external faults. Simulations in PSCAD/EMTDC and MATLAB show that the proposed method can distinguish faults accurately and effectively. </div> 展开更多
关键词 Generalized S-transform VSC-HVDC Phase-Mode transformation DC Cable protection
下载PDF
Study on Transformation of Ideas of Environmental Protection Administration and Construction of Ecological Civilization in China 被引量:1
12
作者 Fu Baorong Yang Tao +4 位作者 He Zhe Zuo Shiwen Gu Chunyu Liu Song Zhang Runjie 《Meteorological and Environmental Research》 CAS 2017年第3期15-17,21,共4页
The transformation process of ideas of environmental protection administration in China was introduced firstly,and then the connotation and construction of ecological civilization were analyzed.
关键词 Ideas of environmental protection ADMINISTRATION transformATION Construction of ECOLOGICAL CIVILIZATION
下载PDF
Development Trend of Energy and Key Points of Ecological Environment Protection in China's "14^(th) Five-Year Plan" Period
13
作者 Mingguo CHEN 《Meteorological and Environmental Research》 CAS 2023年第5期24-28,共5页
From the changes of total primary energy consumption and primary energy consumption structure,installed capacity and power generation of secondary energy(electricity),etc.,the development characteristics of China'... From the changes of total primary energy consumption and primary energy consumption structure,installed capacity and power generation of secondary energy(electricity),etc.,the development characteristics of China's energy structure in the"13^(th) Five-Year Plan"period was comprehensively studied.Combined with the complexity of the international situation,the diversification of the domestic energy system,the intelligence of the energy industry,etc.,the situation and challenges faced by China's energy development were deeply discussed in the four aspects of energy security,energy low-carbon transformation,energy system efficiency,and energy technology level.From the angle of ecological environment protection,the development of energy in the"14^(th) Five-Year Plan"period in China was analyzed,and some policies and measures were put forward. 展开更多
关键词 14^(th)Five-Year Plan Energy development Ecological environmental protection Energy security Low-carbon transformation
下载PDF
Over Voltage Fault due to Disconnection of Consumer’s Transformer Neutral Wire
14
作者 Erdene Adiyasuren Enkh-Od Erdene +1 位作者 Sergelen Byambaa Shagdarsuren Gantumur 《Journal of Energy and Power Engineering》 2023年第1期11-14,共4页
Practically,the load currents in three phases are asymmetric in the power system.It means that the impedances are different in all three phases.If the consumer’s transformer neutral cut off and/or was disconnected fr... Practically,the load currents in three phases are asymmetric in the power system.It means that the impedances are different in all three phases.If the consumer’s transformer neutral cut off and/or was disconnected from the neutral of power supply source,then there will be some trouble and failure occurred.The current in the neutral wire drops down to zero when the neutral wire is cut off and the phase currents of all three-phase equal to each other since there was no return wire.The currents are equal but the voltages at the phase consumers are different.Especially for residential single-phase consumers,the voltage at the consumers of the phase varies differently for three phase systems when the neutral wire was disconnected at consumer side and even the voltage at the consumers one or two of those three phases becomes over nominal voltage or reaches nearly line voltage.In this case,the electronic appliances in that phase will be fed by high voltage than the rated value and they can be broken down.In the power system of UB(Ulaanbaatar)city,there are some occasional such kind of failures every year.Obviously,many electronic appliances were broken down due to high voltage and the electricity utility companies respond for service charge of damaged parts. 展开更多
关键词 Neutral connection and neutral wire phase and line voltage single-phase residential consumer transformer neutral cut off asymmetric load current protective earth
下载PDF
Analysis on the Transfer Characteristics of Rogowski-coil Current Transformer and Its Influence on Protective Relaying
15
作者 Yi Wang Jiaman Li +3 位作者 Yulan Hu Ranran An Zexiang Cai Ruiwen He 《Energy and Power Engineering》 2013年第4期1324-1329,共6页
This paper systematically analyzes the transfer characteristics of the Rogowski-coil Current Transformer and its effect on protective relaying through theoretical analysis, experiments and simulations. The frequency c... This paper systematically analyzes the transfer characteristics of the Rogowski-coil Current Transformer and its effect on protective relaying through theoretical analysis, experiments and simulations. The frequency characteristics and transient characteristics of Rogowski transducer and Rogowski-coil Current Transformer are deeply analyzed based on the physical structure of the transformer.?It is revealed that broad bandwidth of the transformer can improve the performance of protective relaying, and the bandwidth is determined mainly by the parameters of the Rogowski transducer and signal processing circuits. It is also discovered that the measurement errors of transient current mainly depend on the abilities for the current transformer to reproduce an accurate replica of the decaying dc components, which is mainly decided by the decay time constant of the aperiodic component of transient current and the parameters of the integral unit. Finally, some measures are proposed for the performance improvement of Rogowski-coil Current Transformer to meet the requirements of protective relaying system in terms of structural design and testing standards. 展开更多
关键词 CURRENT transformer Rogowski-coil TRANSFER Characteristics protective RELAYING
下载PDF
Transmission Lines Distance Protection Using Differential Equation Algorithm and Hilbert-Huang Transform
16
作者 Xingmao Liu Zhengyou He 《Journal of Power and Energy Engineering》 2014年第4期616-623,共8页
This paper proposed the scheme of transmission lines distance protection based on differential equation algorithms (DEA) and Hilbert-Huang transform (HHT). The measured impedance based on EDA is affected by various fa... This paper proposed the scheme of transmission lines distance protection based on differential equation algorithms (DEA) and Hilbert-Huang transform (HHT). The measured impedance based on EDA is affected by various factors, such as the distributed capacitance, the transient response characteristics of current transformer and voltage transformer, etc. In order to overcome this problem, the proposed scheme applies HHT to improve the apparent impedance estimated by DEA. Empirical mode decomposition (EMD) is used to decompose the data set from DEA into the intrinsic mode functions (IMF) and the residue. This residue has monotonic trend and is used to evaluate the impedance of faulty line. Simulation results show that the proposed scheme improves significantly the accuracy of the estimated impedance. 展开更多
关键词 Hilbert-Huang transform DIFFERENTIAL EQUATION Algorithm DISTANCE protection Transmission LINES
下载PDF
Systematic and Theoretical Unfolding of Research on Xi Jinping’s Discourses on Respecting and Protecting Human Rights
17
作者 张新平 周艺晨 LI Rong(Translated) 《The Journal of Human Rights》 2024年第2期255-286,共32页
Xi Jinping’s discourses on respecting and protect-ing human rights stand as a shining example of the sinicization and modernization of Marxist human rights theory,embodying profound theoretical,political,practical,an... Xi Jinping’s discourses on respecting and protect-ing human rights stand as a shining example of the sinicization and modernization of Marxist human rights theory,embodying profound theoretical,political,practical,and cultural logic.Existing research has conducted comprehensive and systematic theoretical analysis and academic extractions on the following contents:the core essence in-herent in these important discourses,including the“theory of human rights concepts,”the“theory of human rights paths,”the“theory of human rights practices,”the“theory of human rights protection,”and the“theory of human rights governance,”along with their profound theoretical significance,practical significance,and global signifi-cance.In the future,researchers should emphasize efforts on studying the original texts and understanding the original principles.While focusing on the precision of concepts,the scientific nature of the prop-ositions,the maturity of theoretical systems,and the rigor of internal logic related to Xi Jinping’s discourses on respecting and protecting human rights,researchers should also pay attention to constructing a discourse system on human rights from the dimensions of discourse power,discourse cluster,and discourse field.Researchers should be adept at drawing innovative insights into human rights theory from China’s vibrant human rights practices and the vast masses of people.This approach will facilitate the systematic unfolding,academic trans-formation,and innovative development of Xi Jinping’s discourses on respecting and protecting human rights. 展开更多
关键词 respecting and protecting human rights systematic nature of content theoretical transformation of achievements
下载PDF
Reform and Research on the Combination of Production and Education in Plant Protection under the Background of Transformation and Development
18
作者 Qiaoyun Weng Yinghui Liu +3 位作者 Huijing Guo Junhai Yuan Jincheng Yuan Jiang Guo 《Journal of Contemporary Educational Research》 2022年第10期86-91,共6页
Plant Protection is an agricultural discipline with strong theoretical and practical significance.In order to adapt to the development direction of the society during the transition period and the need for professiona... Plant Protection is an agricultural discipline with strong theoretical and practical significance.In order to adapt to the development direction of the society during the transition period and the need for professional talents,the researchers have discussed the teaching mode of the plant protection major from various perspectives of the teaching practice.Through the integration of teaching content and knowledge the overall structure of the course is being made clearer and reasonable;The use of different teaching methods has stimulated the initiative of students and achieved remarkable teaching results;The creativity and practical ability of students have been significantly improved;And the examination and evaluation system has been improved,thereby students’performance can be truly reflected.Through the reform and research of plant protection industry-academia and practical teaching,a feasible way is proposed for the combination of industry-academia and the cultivation of practical talents. 展开更多
关键词 transformation development Plant protection Practical teaching
下载PDF
A Novel Digital Image Watermarking Scheme on Copyright Protection Based on Network Manufacture Environment 被引量:2
19
作者 LIU Quan WANG Jin (School of Information Engineering,Wuhan University of Technology,Wuhan 430070,China 《武汉理工大学学报》 CAS CSCD 北大核心 2006年第S2期552-556,共5页
In this paper,we propose a novel wavelet-domain digital image watermarking scheme on copyright protection based on network manufacture environment.It codes the watermarking with error correcting coding and encrypts th... In this paper,we propose a novel wavelet-domain digital image watermarking scheme on copyright protection based on network manufacture environment.It codes the watermarking with error correcting coding and encrypts the watermarking with chaotic encryption.It embeds the watermarking into the coefficients which have large absolute values in the middle-frequency parts got by Discrete Wavelet Transform (DWT) repeatedly.The extraction doesn’t need the original image.Experiment results show that the proposed scheme is easy to implement,and has good robustness to some attacks,such as JPEG compression,average filtering,median filtering,wiener filtering,pepper (?) salt noise,especially to cropping and scaling.In order to solve the prob- lem of the copyright protection of the network manufacture production,the problems of digital image production such as tamper preventing and watermarking attacks preventing and so on are discussed.It solves the problems of manufacture information such as secure exchange and transmissions and production copyright protection and so on. 展开更多
关键词 network manufacture COPYRIGHT protection digital WATERMARKING wavelet transform error CORRECTING coding chaotic ENCRYPTION
下载PDF
A modified lumped parameter model of distribution transformer winding 被引量:5
20
作者 Qingqing Ding Yao Yao +5 位作者 Bingqian Wang Jingwei Fu Wei Zhang Chao Zeng Xiaoping Li Stanimir Valtchev 《Global Energy Interconnection》 2020年第2期158-165,共8页
The modelling of the distribution transformer winding is the starting point and serves as important basis for the transformer characteristics analysis and the lightning pulse response prediction.A distributed paramete... The modelling of the distribution transformer winding is the starting point and serves as important basis for the transformer characteristics analysis and the lightning pulse response prediction.A distributed parameters model can depict the winding characteristics accurately,but it requires complex calculations.Lumped parameter model requires less calculations,but its applicable frequency range is not wide.This paper studies the amplitude-frequency characteristics of the lightning wave,compares the transformer modelling methods and finally proposes a modified lumped parameter model,based on the above comparison.The proposed model minimizes the errors provoked by the lumped parameter approximation,and the hyperbolic functions of the distributed parameter model.By this modification it becomes possible to accurately describe the winding characteristics and rapidly obtain the node voltage response.The proposed model can provide theoretical and experimental support to lightning protection of the distribution transformer. 展开更多
关键词 Wide band frequency response Distributed parameter model Lumped parameter model Distribution transformer Lightning protection
下载PDF
上一页 1 2 246 下一页 到第
使用帮助 返回顶部