期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Developing microwave-induced thermoacoustic tomography:System,application,and reconstruction
1
作者 Shuang-Li Liu Wan-Ting Peng +4 位作者 Xiao-Zhang Zhu Jian Song Xin Shang Hua Zhang Zhi-Qin Zhao 《Journal of Electronic Science and Technology》 EI CSCD 2023年第4期1-19,共19页
A microwave-induced thermoacoustic imaging(MITAT)system is a non-destructive physical medical imaging method that combines the advantages of the high contrast of microwave imaging and the high resolution of ultrasound... A microwave-induced thermoacoustic imaging(MITAT)system is a non-destructive physical medical imaging method that combines the advantages of the high contrast of microwave imaging and the high resolution of ultrasound imaging.It uses the microwave as the excitation source and ultrasound as the information carrier.When different kinds of biological tissue absorb electromagnetic energy,it results in localized temperature rises.The thermal expansion will induce ultrasonic signals(i.e.,thermoacoustic signals),known as the thermoacoustic effect.The microwave absorption image of the sample can be reconstructed by algorithm processing.The MITAT contrast depends on different dielectric parameters of different kinds of tissue.We introduce the developed system and its application.In addition,the challenges and prospects of MITAT for further development are discussed. 展开更多
关键词 APPLICATION microwave-induced thermoacoustic tomography(mitat) RECONSTRUCTION SYSTEM
下载PDF
Application of time reversal mirror technique in microwave-induced thermo-acoustic tomography system 被引量:4
2
作者 CHEN GuoPing ZHAO ZhiQin +2 位作者 ZHENG WenJun NIE ZaiPing LIU QingHuo 《Science China(Technological Sciences)》 SCIE EI CAS 2009年第7期2087-2095,共9页
Microwave-induced thermo-acoustic tomography (MITAT) is a promising technique with great potential in biomedical imaging. It has both the high contrast of the microwave imaging and the high resolution of the ultrasoun... Microwave-induced thermo-acoustic tomography (MITAT) is a promising technique with great potential in biomedical imaging. It has both the high contrast of the microwave imaging and the high resolution of the ultrasound imaging. In this paper, the proportional relationship between the absorbed microwave energy distribution and the induced ultrasound source distribution is derived. Further, the time reversal mirror (TRM) technique based on the pseudo-spectral time domain (PSTD) method is applied to MITAT system. The simulation results show that high contrast and resolution can be achieved by the TRM technique based on PSTD method even for the received signals with very low signal-to-noise ratio (SNR) and the model parameter with random fluctuation. 展开更多
关键词 microwave-induced thermo-acoustic tomography (mitat) TIME REVERSAL MIRROR (TRM) pseudo–spectrum TIME domain (PSTD)
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部