This study aimed to introduce a novel mini-open pedicle screw fixation technique via Wiltse approach, and com- pared it with the traditional posterior open method. A total of 72 cases of single-segment thoracolumbar f...This study aimed to introduce a novel mini-open pedicle screw fixation technique via Wiltse approach, and com- pared it with the traditional posterior open method. A total of 72 cases of single-segment thoracolumbar fractures without neurologic injury underwent pedicle screw fixation via two different approaches. Among them, 37 patients were treated using posterior open surgery, and 35 patients received mini-open operation via Wiltse approach. Crew placement accuracy rate, operative time, blood loss, postoperative drainage, postoperative hospitalization time, radiation exposure time, postoperative improvement in R value, Cobb's angle and visual analog scale (VAS) scores of the two methods were compared. There were no significant differences in the accuracy rate of pedicle screw placement, radiation exposure and postoperative R value and Cobb's angle improvement between the two groups. However, the mini-open method had obvious advantages over the conventional open method in operative time, blood loss, postoperative drainage, postoperative hospitalization time, and postoperative improvement in VAS. The mini-open pedicle screw technique could be applied in treatment of single-segment thoracolumbar fracture without neurologic injury and had advantages of less tissue trauma, short operative and rehabilitative time on the premise of guaranteed accuracy rate and no increased radiation exposure.展开更多
The conditions of heating and cooling of piercing mandrels made of 4X5MFS steel of a three-roll screw mill 30-80 in the production of a closed cavity of steel vessels of small volume are determined.It is established t...The conditions of heating and cooling of piercing mandrels made of 4X5MFS steel of a three-roll screw mill 30-80 in the production of a closed cavity of steel vessels of small volume are determined.It is established that multiple cycles of heating up to 600℃ and cooling with water up to 80℃ for about 7 seconds/1 cycle lead to the formation of ridges,shells and cracks on the surface and in the volume of the tool.The loss of structural strength of the material leads to the breakdown of the mandrel during the stitching process.The technique and equipment of magnetic powder control have been developed to establish the dynamics of the growth of internal and external defects of mandrels.An equation is obtained that allows determining the increase in the number of defects in the sewing tool of a screw rolling mill.The technology of non-destructive testing made it possible to develop a rational plan for replacing the sewing mandrels,which allows for predicting the appearance of defects leading to a complex breakdown of the deforming tool at the NPO Pribor machine-building enterprise.展开更多
基金supported by the National Natural Science Foundation of China(Grant No.30973058, 81171694,and 81371968)the Program for Development of Innovative Research Team in the First Affiliated Hospital of NJMU(No.IRT-015)A Project Funded by the Priority Academic Program Development of Jiangsu Higher Education Institutions
文摘This study aimed to introduce a novel mini-open pedicle screw fixation technique via Wiltse approach, and com- pared it with the traditional posterior open method. A total of 72 cases of single-segment thoracolumbar fractures without neurologic injury underwent pedicle screw fixation via two different approaches. Among them, 37 patients were treated using posterior open surgery, and 35 patients received mini-open operation via Wiltse approach. Crew placement accuracy rate, operative time, blood loss, postoperative drainage, postoperative hospitalization time, radiation exposure time, postoperative improvement in R value, Cobb's angle and visual analog scale (VAS) scores of the two methods were compared. There were no significant differences in the accuracy rate of pedicle screw placement, radiation exposure and postoperative R value and Cobb's angle improvement between the two groups. However, the mini-open method had obvious advantages over the conventional open method in operative time, blood loss, postoperative drainage, postoperative hospitalization time, and postoperative improvement in VAS. The mini-open pedicle screw technique could be applied in treatment of single-segment thoracolumbar fracture without neurologic injury and had advantages of less tissue trauma, short operative and rehabilitative time on the premise of guaranteed accuracy rate and no increased radiation exposure.
文摘The conditions of heating and cooling of piercing mandrels made of 4X5MFS steel of a three-roll screw mill 30-80 in the production of a closed cavity of steel vessels of small volume are determined.It is established that multiple cycles of heating up to 600℃ and cooling with water up to 80℃ for about 7 seconds/1 cycle lead to the formation of ridges,shells and cracks on the surface and in the volume of the tool.The loss of structural strength of the material leads to the breakdown of the mandrel during the stitching process.The technique and equipment of magnetic powder control have been developed to establish the dynamics of the growth of internal and external defects of mandrels.An equation is obtained that allows determining the increase in the number of defects in the sewing tool of a screw rolling mill.The technology of non-destructive testing made it possible to develop a rational plan for replacing the sewing mandrels,which allows for predicting the appearance of defects leading to a complex breakdown of the deforming tool at the NPO Pribor machine-building enterprise.