期刊文献+
共找到1,206篇文章
< 1 2 61 >
每页显示 20 50 100
Two-Year Outcomes of Midline lumbar Fusion Versus Minimally Invasive Transforaminal Lumbar Interbody Fusion in the Treatment of L4-L5 Degenerative Disease 被引量:4
1
作者 WU Feng Liang DANG Lei +5 位作者 ZHOU Hua YU Miao WEI Feng JIANG Liang LIU Zhong Jun LIU Xiao Guang 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2020年第11期839-848,共10页
Objective We aimed to compare the clinical and radiological outcomes of midline lumbar fusion(MIDLF)versus minimally invasive transforaminal lumbar interbody fusion(MI-TLIF)in patients with degenerative spondylolisthe... Objective We aimed to compare the clinical and radiological outcomes of midline lumbar fusion(MIDLF)versus minimally invasive transforaminal lumbar interbody fusion(MI-TLIF)in patients with degenerative spondylolisthesis and/or stenosis in L4-L5 two years after surgery.Methods Consecutively treated patients with lumbar pathology who underwent MIDLF(n=16)and a historical control group who underwent MI-TLIF(n=34)were included.Clinical symptoms were evaluated using Oswestry Disability Index(ODI),the 36-Item Short-Form Health Survey,and visual analog scale(VAS)scores before surgery and 3,6,12,and 24 months after surgery.Results The mean operative time and hematocrit(HCT,Day 1)were significantly shorter and lower in MIDLF cases(174 min vs.229 min,P<0.001;0.34 vs.0.36,P=0.037).The MI-TLIF group showed better improvement than the MIDLF group in ODI and VAS back and leg pain at 3 months postoperatively.VAS leg pain was higher in MIDLF than in MI-TLIF cases at 6 months.At 24 months follow-up,VAS back pain was higher in MI-TLIF than in MIDLF cases(P=0.018).Conclusion MIDLF is comparable to MI-TLIF at L4-5 in clinical outcomes and fusion rates,and the results verified the meaningful advantage of using MIDLF for the elderly with osteoporosis. 展开更多
关键词 minimally invasive techniques Cortical bone trajectory Clinical outcomes Midline lumbar fusion transforaminal lumbar interbody fusion
下载PDF
Correlation study between the changes of motor evoked potential and the improvement of spinal canal volume in minimally invasive transforaminal lumbar interbody fusion
2
作者 CHEN Huan-xiong HE Xian-bo +6 位作者 LI Guo-jun TANG Song-jie ZHONG Zhen-hao HUANG Tao LIN You-cai LIN Su-yu MENG Zhi-bin 《Journal of Hainan Medical University》 CAS 2023年第8期26-31,共6页
Objective:To analyze the correlation between the amplitude changes of motor evoked potential(MEP),the 3D volume changes of spinal canal measuring by postoperative CT and the improvement rate of clinical symptoms after... Objective:To analyze the correlation between the amplitude changes of motor evoked potential(MEP),the 3D volume changes of spinal canal measuring by postoperative CT and the improvement rate of clinical symptoms after the spinal canal decompression in minimally invasive transforaminal lumbar interbody fusion(MIS-TLIF),and to explore the predictive value of the changes of both MEP amplitude and spinal canal volume in the assessment of long-term clinical prognosis in MIS-TLIF.Methods:A retrospective study of 68 patients with L4/5 spinal stenosis treated with MIS-TLIF was performed.The changes of both intraoperative MEP amplitude and 3D spinal canal volume during the spinal canal decompression,as well as the visual analogue scale(VAS)and Oswestry dysfunction index(ODI)scores in the long-term follow-up were all recorded.Results:The values of intraoperative MEP amplitude was 159.04%higher in 68 patients with MIS-TLIF after spinal canal decompression(P<0.01).The 3 postoperative 3D spinal canal volume(4.89±1.27)cm increased by 31.22%in comparison 3 with preoperative date(3.78±1.08)cm(P<0.01).The VAS and ODI scores were improved to 78.55%and 80.60%,respectively at the last follow-up(P<0.01).The improvement rate of MEP amplitude on the decompression side was positively correlated with the improvement rate of postoperative spinal canal volume(r=0.272,P=0.025).The improvement rate of postoperative spinal canal volume was positively correlated with the improvement rate of VAS and ODI at the last follow-up(r=0.656,r=0.490,P<0.01).Moreover,the improvement rate of MEP amplitude on the decompression side was also positively correlated with the improvement rate of VAS and ODI at the last follow-up(r=0.322 and 0.235,respectively,P<0.05).Conclusion:The increase of MEP amplitude after spinal canal decompression in patients with lumbar spinal stenosis treated by MIS-TLIF was closely correlated with both of the increase of spinal canal volume and the improvement of clinical symptoms.Therefore,MEP amplitude monitoring was not only the one of the important monitoring methods for predicting the prognosis of MIS-TLIF but also the reliably predictive value in the long-term clinical prognosis in MIS-TLIF. 展开更多
关键词 lumbar spinal stenosis minimally invasive transforaminal lumbar interbody fusion Motor evoked potentials Spinal canal volume
下载PDF
Minimally invasive transforaminal lumbar interbody fusion aided with computer-assisted spinal navigation system combined with electromyography monitoring 被引量:4
3
作者 LUO Wei ZHANG Fan LIU Tie DU Xing-li CHEN An-ming LI Feng 《Chinese Medical Journal》 SCIE CAS CSCD 2012年第22期3947-3951,共5页
Background Minimally invasive techniques are gaining wide-spread application in lumbar fusion surgery, because they may have advantage over conventional open surgery in approach-related morbidity. This research was ai... Background Minimally invasive techniques are gaining wide-spread application in lumbar fusion surgery, because they may have advantage over conventional open surgery in approach-related morbidity. This research was aimed to evaluate the safety and accuracy of the techniques of minimally invasive transforaminal lumbar interbody fusion by using a computer-assisted spinal navigation system combined with electromyography monitoring. Methods Sixteen patients underwent minimally invasive transforaminal lumbar interbody fusion. A computer-assisted spinal navigation system and electromyography were used for guiding pedicle screw placement. The operative duration, blood loss, complications, and fluoroscopic time were recorded. Clinical outcome was assessed by Visual Analog Scale and Oswestry Disability Index. Radiographic images were obtained to evaluate the accuracy of pedicle screw placement and fusion rates. Results The Visual Analog Scale and Oswestry Disability Index scores were vastly improved postoperatively. A total of 64 pedicle screws were implanted and three were regarded as misplacement by post-operative CT scan. Three screw trajectories were adjusted according to intra-operative stimulus-evoked electromyography monitoring. The average fluoroscopy time in each patient was 31.8 seconds, which equals to 7.9 seconds per pedicle screw. No patients had instrument related neurological complications, infection, implant failure or revision. Successful fusion was found in all patients. Conclusions The combination of navigation system and real-time electromyography monitoring can make the minimally invasive operation more safe and accurate while decreasing radiation exposure time of the medical staff and patient and minimizing the chance and the degree of the pedicle screw misplacement. 展开更多
关键词 minimally invasive spine surgery computer-assisted navigation transforaminal lumbar interbodyfusion electromyographic monitoring
原文传递
Biomechanical evaluation of two fusion techniques based on finite element analysis:Percutaneous endoscopic and minimally invasive transforaminal lumbar interbody fusion 被引量:1
4
作者 Yang Yan Jiarui Li +7 位作者 Jianhao Yu Yan Wang Hao Dong Yuqin Sun Xiaogang Wu Liming He Weiyi Chen Haoyu Feng 《Medicine in Novel Technology and Devices》 2022年第4期17-25,共9页
As a novel minimally invasive technique,percutaneous endoscopic transforaminal lumbar interbody fusion(PETLIF)has been widely used in the treatment of lumbar degenerative diseases.The purpose of this study was to anal... As a novel minimally invasive technique,percutaneous endoscopic transforaminal lumbar interbody fusion(PETLIF)has been widely used in the treatment of lumbar degenerative diseases.The purpose of this study was to analyze these two operation types’biomechanical performances of PE-TLIF and traditional minimally invasive transforaminal lumbar interbody fusion(MIS-TLIF)using the finite element(FE)method.The intact FE models of L4-L5 were established and validated based on the CT images.On this basis,the FE models of MIS-TLIF and PETLIF were established and analyzed.It is demonstrated that for lumbar interbody fusion with the oblique asymmetrically implanted cage under bilateral pedicle screws and rods fixation,such as MIS-TLIF and PE-TLIF,different degrees of articular process resection have no significant effect on the cage subsidence,and the surgical segment can achieve similar stability.In addition,the maximum stress of the L4 inferior endplate of MIS-TLIF and PE-TLIF is greater than that of the L5 superior endplate,which indicates that MIS-TLIF and PE-TLIF can cause cage subsidence in the L4 inferior endplate. 展开更多
关键词 Percutaneous endoscopic transforaminal lumbar interbody fusion minimally invasive surgery Degenerative lumbar diseases Finite element analysis BIOMECHANICS
原文传递
Instrumentation-related complications of lumbar degenerative disc diseases treated by minimally invasive transforaminal lumbar interbody fusion 被引量:1
5
作者 Xinyu Yang Xinyu Liu 《Brain Science Advances》 2019年第3期213-219,共7页
Objective:To analyze the instrumentation-related complications of patients with lumbar degenerative disc diseases(LDD)who underwent minimally invasive transforaminal lumbar interbody fusion(MISTLIF)and to discuss the ... Objective:To analyze the instrumentation-related complications of patients with lumbar degenerative disc diseases(LDD)who underwent minimally invasive transforaminal lumbar interbody fusion(MISTLIF)and to discuss the potential strategy for the control of these complications.Methods:A total of 87 patients with LDD were treated with the MIS-TLIF procedure.Complications,including malposition or breakage of guide pin,percutaneous pedicle screw(PPS)or cages,neurological deficit,and superior-level facet joint violations,were determined during and after the surgery.Computed tomography(CT)was used to evaluate the PPS accuracy and the superior-level facet joint violations.Results:A total of 386 PPSs were used.During the surgery,3(0.8%)guide pin and 1(0.3%)PPS perforated the anterior wall of the vertebral body,respectively.One(0.3%)PPS was pulled out during the reduction of slip.Malposition of the cages occurred in 6(1.6%)PPSs.These were all adjusted accordingly during the surgery.All the patients received>2 years of follow-up.No loosening or breakage of PPS and cage was observed,but CT showed 27(7.0%)PPSs misplaced.No neurological deficit related to misplaced PPS was observed.The total facet joint violation(FJV)rate was 36.2%,with grade 2 and grade 3 violations is 21(12.1%)and 6(3.4%),respectively.Conclusion:MIS-TLIF has similar instrumentation-related complications with open TLIF.Accurate preoperative evaluation and improved surgical techniques can effectively reduce these instrumentation-related complications. 展开更多
关键词 lumbar DEGENERATIVE diseases minimally invasive surgery transforaminal lumbar interbody fusion INSTRUMENTATION complication
原文传递
Minimally invasive procedures on the lumbar spine 被引量:8
6
作者 Branko Skovrlj Jeffrey Gilligan +1 位作者 Holt S Cutler Sheeraz A Qureshi 《World Journal of Clinical Cases》 SCIE 2015年第1期1-9,共9页
Degenerative disease of the lumbar spine is a common and increasingly prevalent condition that is often implicated as the primary reason for chronic low back pain and the leading cause of disability in the western wor... Degenerative disease of the lumbar spine is a common and increasingly prevalent condition that is often implicated as the primary reason for chronic low back pain and the leading cause of disability in the western world. Surgical management of lumbar degenerative disease has historically been approached by way of open surgical procedures aimed at decompressing and/or stabilizing the lumbar spine. Advances in technology andsurgical instrumentation have led to minimally invasive surgical techniques being developed and increasingly used in the treatment of lumbar degenerative disease. Compared to the traditional open spine surgery, minimally invasive techniques require smaller incisions and decrease approach-related morbidity by avoiding muscle crush injury by self-retaining retractors, preventing the disruption of tendon attachment sites of important muscles at the spinous processes, using known anatomic neurovascular and muscle planes, and minimizing collateral soft-tissue injury by limiting the width of the surgical corridor. The theoretical benefits of minimally invasive surgery over traditional open surgery include reduced blood loss, decreased postoperative pain and narcotics use, shorter hospital length of stay, faster recover and quicker return to work and normal activity. This paper describes the different minimally invasive techniques that are currently available for the treatment of degenerative disease of the lumbar spine. 展开更多
关键词 minimally invasive SURGERY SPINE SURGERY lumbar SPINE Degenerative disease interbody fusion POSTEROLATERAL fusion DECOMPRESSION Indirect DECOMPRESSION techniques
下载PDF
Comparison between Minimally Invasive Transforaminal Lumbar Interbody Fusion and Conventional Open Transforaminal Lumbar Interbody Fusion: An Updated Meta-analysis 被引量:25
7
作者 Lei Xie Wen-Jian Wu Yu Liang 《Chinese Medical Journal》 SCIE CAS CSCD 2016年第16期1969-1986,共18页
Background: The previous studies agree that minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) has better function outcomes, less blood loss, and shorter hospital stay, when compared to open-TLIF.... Background: The previous studies agree that minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) has better function outcomes, less blood loss, and shorter hospital stay, when compared to open-TLIF. However, there are no significance differences on operative time, complication, and reoperation rate between the two procedures. This could be from less relative literatures and lower grade evidence. The further meta-analysis is needed with more and higher grade evidences to compare the above two TLIF procedures. Methods: Prospective and retrospective studies that compared open-TLIF and MIS-TLIF were identified by searching the Medline, Embase, Web of Science, China National Knowledge Infrastructure, Wanfang, and VIP database (the literature search comprised Medical Subject Heading terms and key words or Emtree term). The retrieval time ranged from the date when the database was founded to January 2015. Pooled risk ratios (RRs) and weighted mean differences (WMDs) with 95% confidence intervals were calculated for the clinical outcomes and perioperative data. Results: Twenty-four studies (n =1967 patients) were included in this review (n =951, open-TLIF, n 1016, MIS-TLIF). MIS-TLIF was associated with a significant decrease in the visual analog score (VAS)-back pain score (WMD 0.44; P= 0.001), Oswestry Disabilities Index (WMD 1.57; P =0.005), early ambulation (WMD = -1.77; P = 0.0001), less blood loss (WMD = -265.59; P 〈 0.00001), and a shorter hospital stay (WMD =-1.89; P 〈 0.0001). However, there were no significant differences in the fusion rate (RR =0.99; P = 0.34), VAS-leg pain (WMD = -0.10; P = 0.26), complication rate (RR = 0.84; P = 0.35), operation time (WMD = 5.23; P = 0.82), or reoperation rate (RR = 0.73; P = 0.32). Conclusions: MIS-TLIF resulted in a similar fusion rate with better functional outcome, less blood loss, shorter ambulation, and hospital stay; furthermore, it did not increase the complication or reoperation rate based on the existing evidence. 展开更多
关键词 Clinical Outcomes META-ANALYSIS minimally lnvasive Surgery transforaminal lumbar interbody fusion
原文传递
Mast Quadrant-assisted Minimally Invasive Modified Transforaminal Lumbar Interbody Fusion: Single Incision Versus Double Incision 被引量:9
8
作者 Xin-Lei Xia Hong-Li Wang Fei-Zhou Lyu Li-Xun Wang Xiao-Sheng Ma Jian-Yuan Jiang 《Chinese Medical Journal》 SCIE CAS CSCD 2015年第7期871-876,共6页
Background: The concept of minimally invasive techniques is to make every effort to reduce tissue damage. Certainly, reducing skin incision is an important part of these techniques. This study aimed to investigate th... Background: The concept of minimally invasive techniques is to make every effort to reduce tissue damage. Certainly, reducing skin incision is an important part of these techniques. This study aimed to investigate the clinical feasibility of Mast Quadrant-assisted modified transforaminal lumbar interbody fusion (TLIF) with a small single posterior median incision. Methods: During the period of March 2011 to March 2012, 34 patients with single-segment degenerative lumbar disease underwent the minimally invasive modified TLIF assisted by Mast Quadrant with a small single posterior median incision (single incision group). The cases in this group were compared to 37 patients with single-segment degenerative lumbar disease in the double incision group. The perioperative conditions of patients in these two groups were statistically analyzed and compared. The Oswestry Disability Index (ODI) scores, Visual Analog Scale (VAS) scores, and sacrospinalis muscle damage evaluation indicators before operation and 3, 12 months postoperation were compared. Results: A total of 31 and 35 cases in the single incision and double incision groups, respectively, completed at least 12 months of systemic follow-up. The differences in perioperative conditions between the two groups were not statistically significant. The incision length of the single incision group was significantly shorter than that of the double incision group (P 〈 0.01). The ODI and VAS scores of patients in both groups improved significantly at 3 and 12 months postoperation. However, these two indicators at 3 and 12 months postoperation and the sacrospinalis muscle damage evaluation indicators at 3 months postoperation did not differ significantly between the two groups (P _〉 0.05). Conclusions: Mast Quadrant-assisted modified TLIF with a small single posterior median incision has excellent clinical feasibility compared to minimally invasive TLIF with a double paramedian incision. 展开更多
关键词 lnterbody fusion lumbar lumbar fusion Mast Quadrant Retractor minimally invasive Spine Surgery transforaminal lumbar lnterbody fusion
原文传递
Comparing minimally invasive and open transforaminal lumbar interbody fusion for treatment of degenerative lumbar disease: a meta-analysis 被引量:19
9
作者 Sun Zhi-jian Li Wen-jing +1 位作者 Zhao Yu Qiu Gui-xing 《Chinese Medical Journal》 SCIE CAS CSCD 2013年第20期3962-3971,共10页
Background Transforaminal lumbar interbody fusion (TLIF) through a minimally invasive approach (mTLIF) was introduced to reduce soft tissue injury and speed recovery. Studies with small numbers of patients have be... Background Transforaminal lumbar interbody fusion (TLIF) through a minimally invasive approach (mTLIF) was introduced to reduce soft tissue injury and speed recovery. Studies with small numbers of patients have been carried out, comparing mTLIF with traditional open TLIF (oTLIF), but inconsistent outcomes were reported. 展开更多
关键词 transforaminal lumbar interbody fusion degenerative lumbar disease minimally invasive surgery mini-open surgery meta-analysis
原文传递
Radiological and clinical outcomes of midline lumbar fusion on sagittal lumbar-pelvic parameters for degenerative lumbar diseases 被引量:1
10
作者 Yue-Tian Wang Bing-Xu Li +2 位作者 Shi-Jun Wang Chun-De Li Hao-Lin Sun 《World Journal of Clinical Cases》 SCIE 2022年第35期12880-12889,共10页
BACKGROUND Improving the sagittal lumbar-pelvic parameters after fusion surgery is important for improving clinical outcomes.The impact of midline lumbar fusion(MIDLF)on sagittal lumbar-pelvic alignment for the manage... BACKGROUND Improving the sagittal lumbar-pelvic parameters after fusion surgery is important for improving clinical outcomes.The impact of midline lumbar fusion(MIDLF)on sagittal lumbar-pelvic alignment for the management of degenerative lumbar diseases is still unknown.AIM To analyze the effects of short-segment MIDLF and minimally invasive transforaminal lumbar interbody fusion(MIS-TLIF)on sagittal lumbar-pelvic parameters.METHODS We retrospectively analyzed 63 patients with degenerative lumbar diseases who underwent single-segment MIDLF or MIS-TLIF.The imaging data of patients were collected before surgery and at the final follow-up.The radiological sagittal parameters included the lumbar lordosis(LL),lower LL,L4 slope(L4S),L5 slope(L5S),L5 incidence(L5I),L1 axis and S1 distance(LASD),pelvic incidence(PI),pelvic tilt(PT),sacral slope(SS),and PI-LL mismatch(PI-LL).Additionally,the clinical outcomes,including lower back and leg pain visual analog scale(VAS)and Oswestry disability index(ODI)scores,were also analyzed.RESULTS In both groups,LL and Lower LL significantly increased,while L5I and LASD significantly decreased at the final follow-up compared to that recorded prior to operation(P<0.05).In the MIDLF group,L4S significantly decreased compared to that recorded prior to operation(P<0.05),while the mean SS significantly increased and the PT significantly decreased compared to that recorded prior to operation(P<0.05).In the MIS-TLIF group,SS slightly increased and the mean PT value decreased compared to that recorded prior to operation,but without a statistically significant difference(P>0.05).However,the PI-LL in both groups was significantly reduced compared to that recorded prior to operation(P<0.05).There was no significant difference in the sagittal lumbar-pelvic parameters between the two groups prior to operation and at the final follow-up(P>0.05).In addition,the change in sagittal lumbar-pelvic parameters did not differ significantly,except forΔLASD within the two groups(P>0.05).The mean lower back and leg pain VAS and ODI scores in both groups were significantly improved three months after surgery and at the final follow-up.Though the mean ODI score in the MIDLF group three months after surgery was slightly higher than that in the MIS-TLIF group,there was no significant difference between the two groups at the final follow-up.CONCLUSION Short-segment MIDLF and MIS-TLIF can equally improve sagittal lumbar parameters such as LL,Lower LL,L5I,and LASD in the treatment of lumbar degenerative diseases.However,MIDLF had a larger impact on pelvic parameters than MIS-TLIF. 展开更多
关键词 minimally invasive interbody fusion Cortical bone trajectory Sagittal lumbar-pelvic parameters
下载PDF
Minimally invasive lumbar interbody fusion via MAST Quadrant retractor versus open surgery: a prospective randomized clinical trial 被引量:34
11
作者 WANG Hong-li LU Fei-zhou JIANG Jian-yuan MA Xin XIA Xin-lei WANG Li-xun 《Chinese Medical Journal》 SCIE CAS CSCD 2011年第23期3868-3874,共7页
In recent years, a variety of minimally invasive lumbar surgery techniques have achieved desirable efficacy, but some dispute remains regarding the advantages over open surgery. This study aimed to compare minimally i... In recent years, a variety of minimally invasive lumbar surgery techniques have achieved desirable efficacy, but some dispute remains regarding the advantages over open surgery. This study aimed to compare minimally invasive lumbar interbody fusion via MAST Quadrant retractor with open surgery in terms of perioperative factors, postoperative back muscle function, and 24-month postoperative follow-up results. Methods From September 2006 to June 2008, patients with single-level degenerative lumbar spine disease who were not responsive to conservative treatment were enrolled in this study. Patients were randomized to undergo either minimally invasive surgery (MIS, transforaminal lumbar interbody fusion via MAST Quadrant retractor, 41 cases) or open surgery (improved transforaminal lumbar interbody fusion, 38 cases). Results The MIS group had longer intraoperative fluoroscopy time than the open surgery group, and the open surgery group had significantly increased postoperative drainage volume and significantly prolonged postoperative recovery time compared with the MIS group (P 〈0.05 for all). MRI scanning showed that the T2 relaxation time in the multifidus muscle was significantly shorter in the MIS group than in the open surgery group at 3 months after surgery (P 〈0.01). Surface electromyography of the sacrospinalis muscle showed that the average discharge amplitude and frequency were significantly higher in the MIS group than in the open surgery group (P 〈0.01). The Oswestry disability index and visual analog scale scores were better at 3, 6, 12 and 24 months postoperatively than preoperatively in both groups. Both groups of patients met the imaging convergence criteria at the last follow-up. Conclusions MIS can effectively reduce sacrospinalis muscle injury compared with open surgery, which is conducive to early functional recovery. In the short term, MIS is superior to open surgery, but in the long term there is no significant difference between the two procedures. 展开更多
关键词 lumbar interbody fusion minimally invasive spine surgery MAST Quadrant retractor sacrospinalis muscle injury
原文传递
一种新型压配式腰椎椎间融合器的机械性能
12
作者 李世文 于长水 +3 位作者 刘启 王智博 刘禹良 祁全 《中国组织工程研究》 CAS 北大核心 2025年第21期4492-4498,共7页
背景:行经皮微创椎间孔腰椎椎间融合置入椎间融合器时,由于入路操作范围狭窄,有牵拉神经根损伤或置入融合器位置不良等风险,为了解决以上问题作者课题组发明了一种新型机械结构可变形压配式cage(Press-fit cage,YP-cage)。目的:对新型... 背景:行经皮微创椎间孔腰椎椎间融合置入椎间融合器时,由于入路操作范围狭窄,有牵拉神经根损伤或置入融合器位置不良等风险,为了解决以上问题作者课题组发明了一种新型机械结构可变形压配式cage(Press-fit cage,YP-cage)。目的:对新型腰椎融合器YP-cage的机械强度特性进行初步评估。方法:对不同尺寸9,11,13 mm高度的新型YP-cage(n=9)和聚醚醚酮-cage(n=9)进行了静态轴向压缩实验和静态轴向扭转实验,分别采集力-位移曲线计算屈服位移及载荷、极限载荷位移及刚度,屈服角位移及扭矩、极限载荷角位移扭矩及刚度,并进行对比分析。结果与结论:(1)在静态轴向压缩测试中,YP-cage在3组测试中(9,11,13 mm),其刚度、屈服载荷、极限位移和载荷极限方面均优于聚醚醚酮-cage(P <0.01),但YP-cage的屈服位移小于聚醚醚酮-cage(P <0.05);(2)在静态扭转测试中,除了9 mm组的YP-cage和聚醚醚酮-cage在极限扭转角度上差异无显著性意义,YP-cage在屈服扭矩、屈服扭转角度及极限扭矩均小于聚醚醚酮-cage(P <0.01),而YP-cage扭转刚度在9 mm组和11 mm组大于聚醚醚酮-ccage(P <0.01);(3)结果表明新型压配式机械结构椎间融合器相较于聚醚醚酮材质cage具有更高的抗压强度,但抗扭强度不如聚醚醚酮-cage。 展开更多
关键词 椎间融合装置 经孔椎体间融合术 脊柱融合 机械性能 物理性质
下载PDF
Transforaminal Lumbar Interbody Fusion for Traumatic Lumbar Spondylolisthesis 被引量:2
13
作者 徐建广 曾炳芳 +5 位作者 孔维清 周蔚 付一山 赵必增 张涛 连小峰 《Journal of Shanghai Jiaotong university(Science)》 EI 2010年第5期626-631,共6页
To evaluate the clinical outcome,effectiveness and safety of the surgical management of traumatic lumbar spondylolisthesis with transforaminal lumbar interbody fusion (TLIF) with short segmental instrumentation fixati... To evaluate the clinical outcome,effectiveness and safety of the surgical management of traumatic lumbar spondylolisthesis with transforaminal lumbar interbody fusion (TLIF) with short segmental instrumentation fixation.A retrospective review of a consecutive series of 24 patients with traumatic lumbar spondylolisthesis treated with TLIF procedure was carried out.Intraoperative spinal cord monitoring was used to confirm the peripheral neural function intact during the reduction of the spondylolisthesis.Preoperative clinical and radiographic evaluation of all cases were originally collected prospectively.Data regarding blood loss,operative time,duration of hospital stay,radiographic fusion,instrumentation failure and clinical result were collected and observed at regular follow-up periods.All patients were engaged in high-energy accidents in the lower back and 16 patients had concomitant injuries.The mean operative time was 124 min,mean blood loss was 350 mL,and mean hospital stay was 6.5 days.There were no complications such as incision infection,cerebrospinal fluide (CSF) leakage and nerve root injury and so on.All patients demonstrated a solid lumbar interbody fusion within 4 months,and no evidence of spondylolisthesis correction loss,instrumentation failure and loosing.They all were completely asymptomatic,with normal neurologic findings,and had resumed their previous level of physical activities on the final follow-up.Meticulous clinical examination and careful imaging assessment could assist an early diagonosis in cases of traumatic lumbar spondylolisthesis.Performing open reduction and the TLIF procedure as soon as possible could restore segmental stability and painless function.The TLIF procedure was a safe,effective technique to treat traumatic lumbar spondylolisthesis. 展开更多
关键词 TRAUMA SPONDYLOLISTHESIS lumbar fusion transforaminal lumbar interbody fusion (TLIF)
原文传递
Biomechanical change of lumbar unilateral graded facetectomy and strategies of its microsurgical reconstruction:report of 23 cases 被引量:2
14
作者 Zhou Yue Luo Gang Chu Tongwei Wang Jian Li Changqing Zheng Wenjie Zhang Zhengfeng Hao Yong Zhang Chao 《Journal of Medical Colleges of PLA(China)》 CAS 2008年第2期98-105,共8页
Objective: To evaluate the lumbar stability and the primary clinical results of unilateral facetectomy, transforaminal lumbar interbody fusion (TLIF) and unilateral pedicle screw fixation by X-Tube system. Methods... Objective: To evaluate the lumbar stability and the primary clinical results of unilateral facetectomy, transforaminal lumbar interbody fusion (TLIF) and unilateral pedicle screw fixation by X-Tube system. Methods: Five human lumbar cadaveric functional spine units(FSU) were obtained and graded facetectomy by 0, 1/4, 1/2, 3/4 and 4/4 were performed respectively on the left articular process of them. The stability of these 5 models was evaluated at flexion, extension, lateral bending and axial rotation. After a serial of biomechanical researches, 23 patients from June 2004 to March 2006 in our department underwent unilateral facetectomy, transforaminal lumbar interbody fusion (posterior lumbar interbody fusion) and unilateral pedicle screw instrumentation by X-Tube system. After general anaesthesia, with the guide of fluoroscopy and using X-Tube system, procedures of unilateral endoscopic facetectomy, spinal nerve root decompression, autologus spongy bone transplantation, one cage oblique insertion and unilateral pedicle screw instrumentation were performed. Results: There was no significant difference in flexion, extension, lateral bending and axial rotation of lumbar motion range after unilateral graded facetectomy. The stability of left/right axial direction was greatly affected when the range of graded facetectomy exceed 1/2. According to the Nakai criteria, for the 23 patients, the clinical result was excellent in 15 (65.2%), good in 6 (26.1%) and fair in 2 (8.7%). The fusion rate was 95.6% in excellent and good cases. Although partial absorption of bone grafts was observed in 1 case which might indicate a unsuccessful fusion, there was no loosing and replacement of instrument and no clinical symptoms occurred. Conclusion: The lumbar stability will be affected significantly when the range of graded facetectomy exceeds 1/2. Procedures of unilateral facetectomy, transforaminal lumbar interbody fusion and unilateral pedicle screw fixation is an optional strategy for microsurgical reconstruction, though the indications of the procedure should be carefully restricted. 展开更多
关键词 ENDOSCOPE lumbar disc herniation transforaminal lumbar interbody fusion
下载PDF
Fracture of allograft interbody spacer resulting in post-operative radiculopathy: A case report
15
作者 Andrews Kyle Andrea Rowland +1 位作者 Jacob Stirton Hossein Elgafy 《World Journal of Orthopedics》 2019年第4期206-211,共6页
BACKGROUND Allograft interbody spacers are utilized during transforaminal lumbar interbody fusion(TLIF) to reestablish anterior column support and disc height. While the TLIF technique offers many improvements over pr... BACKGROUND Allograft interbody spacers are utilized during transforaminal lumbar interbody fusion(TLIF) to reestablish anterior column support and disc height. While the TLIF technique offers many improvements over previous surgical methods,instrumentation and bone graft-related complications such as spacer misplacement or migration, screw fracture or misplacement, or rod breakage continue to be reported. The objective of this manuscript is to report on a fractured allograft interbody spacer that displaced into the neural foramen and resulted in impingement on the exiting nerve root that required revision.CASE SUMMARY A 50-year-old male had two-level TLIF with immediate post-operative right L5 radiculopathy. Computed tomography scan demonstrated a fractured allograft interbody spacer that displaced into the right neural foramen and impinged on the exiting L5 nerve root. Revision surgery was performed to remove the broken allograft fragments from the right L5 foramen and the intact portion of the spacer was left in place. The right leg L5 radicular pain resolved. At the last follow up 12 mo after the index procedure, computed tomography scan confirmed sound interbody and posterolateral fusion.CONCLUSION Displacement of broken allograft interbody spacer following TLIF procedures can result in neurological sequelae that require revision. To avoid such an occurrence,the authors recommend allowing sufficient time for the reconstitution of the graft in saline prior to use to decrease brittleness, to use an impactor size that is as close as possible to the spacer size and meticulous inspection of the cortical allograft spacer for any visible imperfection prior to insertion. 展开更多
关键词 transforaminal lumbar interbody fusion interbody fusion ALLOGRAFT
下载PDF
显微镜辅助微创经椎间孔腰椎椎间融合术治疗单节段腰椎滑脱症 被引量:2
16
作者 施耀华 杨建平 +2 位作者 赵洪 翟羽 黎俊 《国际骨科学杂志》 2024年第1期62-67,共6页
目的探讨显微镜辅助经Quadrant通道结合经皮椎弓根钉固定行微创小切口经椎间孔腰椎椎间融合术(MIS-TLIF)治疗单节段腰椎退行性滑脱症的疗效。方法回顾性分析2018年4月至2021年3月行椎体间融合术治疗单节段腰椎退行性滑脱症患者的临床资... 目的探讨显微镜辅助经Quadrant通道结合经皮椎弓根钉固定行微创小切口经椎间孔腰椎椎间融合术(MIS-TLIF)治疗单节段腰椎退行性滑脱症的疗效。方法回顾性分析2018年4月至2021年3月行椎体间融合术治疗单节段腰椎退行性滑脱症患者的临床资料,其中采用开放经椎间孔腰椎椎间融合术(TLIF)治疗患者41例(开放组),经Wiltse入路Quadrant通道直视下TLIF治疗患者25例(微创组),显微镜下减压并采用经皮椎弓根钉TLIF治疗患者38例(显微组)。记录3组患者手术时间、术中出血量、X线透视次数、引流量、术后2天和7天切口周围疼痛视觉模拟评分(VAS)、并发症情况,术后CT检查评估椎弓根钉置钉准确率,记录术前及术后6个月、24个月日本骨科协会(JOA)评分和Oswestry功能障碍指数(ODI),末次随访时采用改良MacNab标准评价临床疗效。结果所有手术均顺利完成。显微组术中出血量、引流量、术后2天和7天切口周围疼痛VAS评分均小于微创组和开放组(P<0.05),椎弓根钉置钉准确率高于微创组和开放组(P<0.05),但术中X线透视次数高于微创组和开放组(P<0.05)。开放组发生术后切口浅表软组织感染1例,疑似感染1例,脑脊液漏1例;微创组出现术后短暂性神经症状2例。3组术后6个月、24个月JOA评分和ODI评分均较术前明显改善(P<0.05),3组间比较无统计学差异(P>0.05)。术后6个月和24个月融合率3组间比较无统计学差异(P>0.05)。按改良MacNab标准,3组患者疗效优良率无统计学差异(P>0.05)。结论显微镜辅助通道下MIS-TLIF治疗单节段腰椎退行性滑脱症,术中出血少、切口疼痛感小、并发症少,采用经皮椎弓根钉置钉准确率高,融合率、疗效优良率与开放手术一致,临床疗效好。 展开更多
关键词 显微镜 微创 腰椎退行性滑脱 经椎间孔椎体间融合术
下载PDF
内镜、微创和开放式经椎间孔椎体间融合术治疗腰椎退行性疾病的效果比较 被引量:1
17
作者 李新武 韦华成 +1 位作者 李昊 魏芳芳 《中国当代医药》 CAS 2024年第16期68-72,共5页
目的比较经椎间孔内镜腰椎椎间融合术(Endo-LIF)、微创腰椎椎间融合术(MIS-TLIF)和开放腰椎椎间融合术(PLIF)治疗腰椎退行性疾病(LDD)的临床疗效和安全性。方法回顾性分析2013年1月至2023年1月在百色市人民医院因LDD接受经椎间孔腰椎椎... 目的比较经椎间孔内镜腰椎椎间融合术(Endo-LIF)、微创腰椎椎间融合术(MIS-TLIF)和开放腰椎椎间融合术(PLIF)治疗腰椎退行性疾病(LDD)的临床疗效和安全性。方法回顾性分析2013年1月至2023年1月在百色市人民医院因LDD接受经椎间孔腰椎椎间融合术就诊的150例患者临床资料,按手术方式分为Endo-LIF组、MIS-TLIF组、PLIF组三组,每组各50例。比较患者手术时间、透视次数、术中失血量、住院时间、并发症以及术前和术后3个月的视觉模拟评分(VAS)、Oswestry功能障碍指数(ODI)评分、椎间隙高度指数、病变节段活动度(ROM)。结果PLIF组的手术时间长于Endo-LIF组和MIS-TLIF组,术中透视次数少于Endo-LIF组和MIS-TLIF组,差异有统计学意义(P<0.05)。Endo-LIF组和MIS-TLIF组的手术时间、术中透视次数比较,差异无统计学意义(P>0.05)。患者术中出血量Endo-LIF组少于MIS-TLIF组及PLIF组,MIS-TLIF组少于PLIF组,差异有统计学意义(P<0.05);患者术后卧床时间和住院时间Endo-LIF组短于MIS-TLIF组及PLIF组,MIS-TLIF组短于PLIF组,差异有统计学意义(P<0.05)。三组患者满意度比较,差异有统计学意义(P<0.05)。Endo-LIF组满意度高于PLIF组,差异有统计学意义(P<0.017)。三组患者术后3个月VAS及ODI评分低于手术前,差异有统计学意义(P<0.01)。三组患者并发症发生率、椎间隙高度指数、ROM比较,差异无统计学意义(P>0.05)。结论Endo-LIF、MIS-TLI、PLIF三种手术方法术后3个月的预后结果相似,PLIF术中透视次数最少,Endo-LIF创伤较小,在降低术中出血,缩短术后卧床时间和住院时间方面优势明显,术后恢复速度较快,适合临床推广。 展开更多
关键词 腰椎退行性疾病 腰椎椎间融合术 内镜 微创 开放式
下载PDF
单侧双通道内镜下(UBE-TLIF)与微创经椎间孔腰椎融合术(MIS-TLIF)治疗退变性腰椎椎管狭窄症的疗效比较 被引量:1
18
作者 周毅 陈日高 +1 位作者 于开凡 廖子康 《生物骨科材料与临床研究》 CAS 2024年第2期32-37,共6页
目的 比较单侧双通道内镜下经椎间孔腰椎椎间融合术(unilateral biportal endoscopic transforaminal lumbar interbodyfusion,UBE-TLIF)与微创经椎间孔入路腰椎椎间融合术(minimal invasive transforaminal lumbar interbody fusion, M... 目的 比较单侧双通道内镜下经椎间孔腰椎椎间融合术(unilateral biportal endoscopic transforaminal lumbar interbodyfusion,UBE-TLIF)与微创经椎间孔入路腰椎椎间融合术(minimal invasive transforaminal lumbar interbody fusion, MIS-TLIF)治疗单节段退行性腰椎椎管狭窄症的疗效。方法 回顾性分析2021年1月至2021年12月成都中医药大学附属医院符合纳入标准的68例单节段退行性腰椎椎管狭窄症患者的临床资料,按手术方式分为UBE-TLIF组(27例)与MIS-TLIF组(41例)。对比两组患者的手术相关指标(手术时间、术中出血量、术后引流量、术后住院天数、并发症发生率等);实验室检查结果[全血C反应蛋白(C-reactive protein, CRP)、血清磷酸肌酸激酶(creatine kinase, CK)]及临床疗效评价[腰痛及下肢疼痛视觉模拟评分(visual analogue scale,VAS)、Oswestry功能障碍指数(Oswestry disability index, ODI)、改良MacNab标准评价优良率、Brantigan标准评价椎间融合率]等。结果 68例患者均获得随访,随访时间12~20个月。与MIS-TLIF组相比,UBE-TLIF组患者的手术时间、住院时间更长,但术中出血量、术后引流量更短(P<0.05)。实验室检查方面:术前两组实验室检查差异无统计学意义(P>0.05);术后3 d UBE-TLIF组全血C反应蛋白含量较MIS-TLIF组低(P<0.05);术后1、3 dUBE-TLIF组血清磷酸肌酸激酶水平均低于MIS-TLIF组(P<0.05)。临床疗效评价:术前两组间患者腰痛及下肢疼痛视觉模拟评分及Oswestry功能障碍指数比较,差异无统计学意义(P>0.05),术后各时间点上述评分均较术前显著下降(P<0.05);组间比较发现各组术后3 d、1个月、6个月、12个月的腰痛及下肢疼痛视觉模拟评分,术后3、12个月Oswestry功能障碍指数,末次随访优良率,椎间融合率比较,差异无统计学意义(P>0.05)。并发症方面:UBE-TLIF组无并发症发生,MIS-TLIF组发生并发症2例,包括术后切口感染1例及术后下肢麻木1例,两组间并发症发生率比较,差异无统计学意义(P>0.05)。结论 UBE-TLIF手术方式可达到与MIS-TLIF手术方式相似的术后腰痛疼痛评分、腿疼痛评分、功能障碍指数,且较MIS-TLIF肌肉损伤释放的CK更少、组织出血量更少、术后恢复更快。 展开更多
关键词 单侧双通道内镜 微创 腰椎间融合 单节段腰椎椎管狭窄
下载PDF
腰椎融合术选择策略及发展趋势
19
作者 程志坚 贺西京 《中国骨伤》 CAS CSCD 2024年第8期746-749,共4页
腰椎融合术已经在腰椎退行性病变、畸形、腰椎骨折或脱位等疾病中广泛应用,是消除或缓解症状、维持疗效的重要方法,也是脊柱外科最重要的技术之一。目前,腰椎融合术式种类繁多,根据不同手术入路分为前侧入路、经侧方入路、后侧入路及椎... 腰椎融合术已经在腰椎退行性病变、畸形、腰椎骨折或脱位等疾病中广泛应用,是消除或缓解症状、维持疗效的重要方法,也是脊柱外科最重要的技术之一。目前,腰椎融合术式种类繁多,根据不同手术入路分为前侧入路、经侧方入路、后侧入路及椎间孔入路等;微创手术包括关节镜辅助、脊柱内窥镜等手术方式;根据不同植骨融合位置又分为椎体外植骨融合和椎体间植骨融合[1]。临床上腰椎融合手术方式的选择方面尚无完全定论。本文回顾、分析不同腰椎融合术的优缺点,结合脊柱微创融合技术等发展趋势展开评论,旨在为临床腰椎融合术的合理实施提供参考,期待未来深入探索、优化手术方法、提高融合效率,降低并发症的新策略,为腰椎疾病患者带来更好的疗效。 展开更多
关键词 腰椎融合术 前路腰椎融合 后路腰椎融合 经椎间孔腰椎融合
下载PDF
机器人导航内镜下经椎间孔入路椎间融合术治疗腰椎间盘突出症
20
作者 江丽强 岳亚玲 +4 位作者 武刚 贾晓川 李毅 张开 刘振武 《临床骨科杂志》 2024年第1期6-10,共5页
目的探讨应用机器人导航内镜下经椎间孔入路椎间融合术治疗腰椎间盘突出症的临床疗效。方法将98例腰椎间盘突出症患者根据治疗方法不同分为观察组(32例,采用机器人导航内镜下经椎间孔入路椎间融合术治疗)与对照组(66例,采用后路腰椎椎... 目的探讨应用机器人导航内镜下经椎间孔入路椎间融合术治疗腰椎间盘突出症的临床疗效。方法将98例腰椎间盘突出症患者根据治疗方法不同分为观察组(32例,采用机器人导航内镜下经椎间孔入路椎间融合术治疗)与对照组(66例,采用后路腰椎椎间融合术治疗)。记录手术时间、术中出血量、术后引流量、住院时间及并发症发生情况,采用疼痛VAS评分评价疼痛改善情况,采用ODI评分评价脊柱功能。结果患者均获得随访,时间12~22个月。手术时间观察组长于对照组(P<0.01)。术中出血量、术后引流量及住院时间观察组均少(短)于对照组(P<0.01)。两组并发症发生率比较差异无统计学意义(P>0.05)。两组术后1周及1、3、6、12个月疼痛VAS评分、ODI均较术前降低(P<0.05);观察组均低于对照组(P<0.01)。结论采用机器人导航内镜下经椎间孔入路椎间融合术治疗腰椎间盘突出症创伤小,疼痛改善情况好,脊柱功能恢复快。 展开更多
关键词 骨科机器人 椎间孔镜 椎间融合 腰椎间盘突出症 微创
下载PDF
上一页 1 2 61 下一页 到第
使用帮助 返回顶部