期刊文献+
共找到1,522篇文章
< 1 2 77 >
每页显示 20 50 100
Quality of Service and Security on Cisco Network Devices, Coupled with the Development of a Mobile Application Prototype Software for Server Room Temperature Monitoring
1
作者 Desire Mudenda Charles Smart Lubobya 《Journal of Computer and Communications》 2024年第8期123-140,共18页
In an era where digital technology is paramount, higher education institutions like the University of Zambia (UNZA) are employing advanced computer networks to enhance their operational capacity and offer cutting-edge... In an era where digital technology is paramount, higher education institutions like the University of Zambia (UNZA) are employing advanced computer networks to enhance their operational capacity and offer cutting-edge services to their academic fraternity. Spanning across the Great East Road campus, UNZA has established one of the most extensive computer networks in Zambia, serving a burgeoning community of over 20,000 active users through a Metropolitan Area Network (MAN). However, as the digital landscape continues to evolve, it is besieged with burgeoning challenges that threaten the very fabric of network integrity—cyber security threats and the imperatives of maintaining high Quality of Service (QoS). In an effort to mitigate these threats and ensure network efficiency, the development of a mobile application to monitor temperatures in the server room was imperative. According to L. Wei, X. Zeng, and T. Shen, the use of wireless sensory networks to monitor the temperature of train switchgear contact points represents a cost-effective solution. The system is based on wireless communication technology and is detailed in their paper, “A wireless solution for train switchgear contact temperature monitoring and alarming system based on wireless communication technology”, published in the International Journal of Communications, Network and System Sciences, vol. 8, no. 4, pp. 79-87, 2015 [1]. Therefore, in this study, a mobile application technology was explored for monitoring of temperatures in the server room in order to aid Cisco device performance. Additionally, this paper also explores the hardening of Cisco device security and QoS which are the cornerstones of this study. 展开更多
关键词 Quality of Service (QoS) Network Security Temperature monitoring mobile Application Cisco Devices
下载PDF
Development and Application of On-Line Corrosion Monitoring Device for Condenser Tube 被引量:1
2
作者 曹杰玉 宋敬霞 +2 位作者 汪德良 龙国军 孙本达 《Electricity》 2004年第2期31-35,共5页
This paper introduces the development and industrial application of an on-line corrosion monitoring device for condenser tubes. Corrosion sensors are made up of representative condenser tubes chosen by eddy current te... This paper introduces the development and industrial application of an on-line corrosion monitoring device for condenser tubes. Corrosion sensors are made up of representative condenser tubes chosen by eddy current test, which enable the monitoring result to be consistent with the corrosion of actual condenser tubes. Localized corrosion rate of condenser tubes can be measured indirectly by a galvanic couple made up of tube segments with and without pits. Using this technology, corrosion problems can be found in time and accurately, and anticorrosive measures be made more economic and effective. Applications in two power plants showed the corrosion measurements are fast and accurate. 展开更多
关键词 condenser tube CORROSION on-line monitoring INSTRUMENTATION
下载PDF
On-Line Monitoring of Cutting Tool Fracture & Wear
3
作者 王信义 肖定国 宋新民 《Journal of Beijing Institute of Technology》 EI CAS 1992年第2期139-150,共12页
A technique of detecting cutting tool fracture and ultimate wear by si- multaneously monitoring both the spindle motor current and cutting process related acoustic emission(AE)in the cutting process is reported.The te... A technique of detecting cutting tool fracture and ultimate wear by si- multaneously monitoring both the spindle motor current and cutting process related acoustic emission(AE)in the cutting process is reported.The technique can detect breakage of drills having diameter over 0.8mm,turning cutter crack of area over 0.2mm,and the ultimate wear.The principle,system construction,experimental method and result of the technique are discussed.The ratio of success in detection approaches 96% or higher. 展开更多
关键词 on-line monitoring acoustic emission/tool fracture motor current
下载PDF
Empowering fall webworm surveillance with mobile phone-based community monitoring: a case study in northern China 被引量:4
4
作者 Chengbo Wang Yanyou Qiao +2 位作者 Honggan Wu Yuanfei Chang Muyao Shi 《Journal of Forestry Research》 SCIE CAS CSCD 2016年第6期1407-1410,共4页
Recent advances in information and communication technologies, such as mobile Internet and smart- phones, have created new paradigms for participatory environment monitoring. The ubiquitous mobile phones with capabili... Recent advances in information and communication technologies, such as mobile Internet and smart- phones, have created new paradigms for participatory environment monitoring. The ubiquitous mobile phones with capabilities such as a global positioning system, camera, and network access, offer opportunities to estab- lish distributed monitoring networks that can perform a wide range of measurements for a landscape. This study examined the potential of mobile phone-based community monitoring of fall webworm (Hyphantria cunea Drury). We built a prototype of a participatory fall webworm monitoring System based on mobile devices that stream- lined data collection, transmission, and visualization. We also assessed the accuracy and reliability of the data collected by the local community. The system performance was evaluated at the Ziya commune of Tianjin municipality in northern China, where fall webworm infestation has occurred. The local community provided data with accuracy comparable to expert measurements (Willmott's index of agreement 〉0.85). Measurements by the local community effectively complemented remote sensing images in both temporal and spatial resolution. 展开更多
关键词 Forest pest monitoring mobile phone Community monitoring Hyphantria cunea Drury Field survey
下载PDF
On-line Monitoring for Phosphorus Removal Process and Bacterial Community in Sequencing Batch Reactor 被引量:4
5
作者 崔有为 王淑莹 李晶 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2009年第3期484-492,共9页
For efficient energy consumption and control of effluent quality, the cycle duration for a sequencing batch reactor (SBR) needs to be adjusted by real-time control according to the characteristics and loading of waste... For efficient energy consumption and control of effluent quality, the cycle duration for a sequencing batch reactor (SBR) needs to be adjusted by real-time control according to the characteristics and loading of waste-water. In this study, an on-line information system for phosphorus removal processes was established. Based on the analysis for four systems with different ecological community structures and two operation modes, anaerobic-aerobic process and anaerobic-anaerobic process, the characteristic patterns of oxidation-reduction potential (ORP) and pH were related to phosphorous dynamics in the anaerobic, anoxic and aerobic phases, for determination of the end of phosphorous removal. In the operation mode of anaerobic-aerobic process, the pH profile in the anaerobic phase was used to estimate the relative amount of phosphorous accumulating organisms (PAOs) and glycogen accumulat-ing organisms (GAOs), which is beneficial to early detection of ecology community shifts. The on-line sensor val-ues of pH and ORP may be used as the parameters to adjust the duration for phosphorous removal and community shifts to cope with influent variations and maintain appropriate operation conditions. 展开更多
关键词 on-line monitoring phosphorus removal sequencing batch reactor PH oxidation-reduction potential
下载PDF
Development and prospect of mobile gravity monitoring and earthquake forecasting in recent ten years in China 被引量:2
6
作者 Yiqing Zhu Fang Liu +1 位作者 Guoqing Zhang Yunma Xu 《Geodesy and Geodynamics》 2019年第6期485-491,共7页
After the Wenchuan earthquake in 2008,China Earthquake Administration has strengthened the monitoring of mobile gravity and earthquake forecasting.This paper mainly analyzes the development of mobile gravity monitorin... After the Wenchuan earthquake in 2008,China Earthquake Administration has strengthened the monitoring of mobile gravity and earthquake forecasting.This paper mainly analyzes the development of mobile gravity monitoring network of China in 2008,the role of time-varying gravity field in the determination of strong earthquake risk and the technical problems that gravity monitoring still needs to be solved.By analysing the mobile gravity monitoring and earthquake prediction in China,the characteristics of gravity anomaly and three elements of earthquake prediction are discussed.The mobile gravity observation data can better reflect the gravity anomalies before the earthquake,especially the strong earthquakes greater than Ms6.0.Finally,we put forward the reconsideration of the development strategy of mobile gravity monitoring and earthquake forecasting in China. 展开更多
关键词 mobile GRAVITY monitoring WENCHUAN EARTHQUAKE Lushan EARTHQUAKE EARTHQUAKE prediction
下载PDF
On-line real-time path planning of mobile robots in dynamic uncertain environment 被引量:2
7
作者 ZHUANG Hui-zhong DU Shu-xin WU Tie-jun 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2006年第4期516-524,共9页
A new path planning method for mobile robots in globally unknown environment with moving obstacles is pre- sented. With an autoregressive (AR) model to predict the future positions of moving obstacles, and the predict... A new path planning method for mobile robots in globally unknown environment with moving obstacles is pre- sented. With an autoregressive (AR) model to predict the future positions of moving obstacles, and the predicted position taken as the next position of moving obstacles, a motion path in dynamic uncertain environment is planned by means of an on-line real-time path planning technique based on polar coordinates in which the desirable direction angle is taken into consideration as an optimization index. The effectiveness, feasibility, high stability, perfect performance of obstacle avoidance, real-time and optimization capability are demonstrated by simulation examples. 展开更多
关键词 mobile robot Dynamic obstacle Autoregressive (AR) prediction on-line real-time path planning Desirable direction angle
下载PDF
Research on Distribution of Electromagnetic Environment around Substations and Optimization Layout of On-line Monitoring 被引量:1
8
作者 Li Peiming Xiao Jun Wang Wenjin 《Meteorological and Environmental Research》 CAS 2019年第6期60-63,共4页
The characteristics and distribution law of electromagnetic environment around substations with different levels of voltage were studied,and the main influencing factors were discussed. Meanwhile,a scheme for locating... The characteristics and distribution law of electromagnetic environment around substations with different levels of voltage were studied,and the main influencing factors were discussed. Meanwhile,a scheme for locating monitoring points suitable for an on-line monitoring system of electromagnetic environment was proposed. 展开更多
关键词 on-line monitoring ELECTROMAGNETIC environment SUBSTATION Optimization layout
下载PDF
Monitoring the Heavy Element of Cr in Agricultural Soils Using a Mobile Laser-Induced Breakdown Spectroscopy System with Support Vector Machine 被引量:2
9
作者 谷艳红 赵南京 +6 位作者 马明俊 孟德硕 余洋 贾尧 方丽 刘建国 刘文清 《Chinese Physics Letters》 SCIE CAS CSCD 2016年第8期64-68,共5页
Due to its complicated matrix effects, rapid quantitative analysis of chromium in agricultural soils is difficult without the concentration gradient samples by laser-induced breakdown spectroscopy. To improve the anal... Due to its complicated matrix effects, rapid quantitative analysis of chromium in agricultural soils is difficult without the concentration gradient samples by laser-induced breakdown spectroscopy. To improve the analysis speed and accuracy, two calibration models are built with the support vector machine method: one considering the whole spectra and the other based on the segmental spectra input. Considering the results of the multiple linear regression analysis, three segmental spectra are chosen as the input variables of the support vector regression (SVR) model. Compared with the results of the SVR model with the whole spectra input, the relative standard error of prediction is reduced from 3.18% to 2.61% and the running time is saved due to the decrease in the number of input variables, showing the robustness in rapid soil analysis without the concentration gradient samples. 展开更多
关键词 of is on LIBS in monitoring the Heavy Element of Cr in Agricultural Soils Using a mobile Laser-Induced Breakdown Spectroscopy System with Support Vector Machine SVR CR with
下载PDF
On-line monitoring of dissolved gas-in-oil with FTIR spectra 被引量:1
10
作者 XianyongLiu YunluoLiu LiYue 《Journal of University of Science and Technology Beijing》 CSCD 2003年第4期65-68,共4页
To overcome the disadvantages of conventional DGA (dissolved gas-in-oil)analysis using gas chromatography and other electrochemical sensors, initial researches werecompleted to realize on-line monitoring of dissolved ... To overcome the disadvantages of conventional DGA (dissolved gas-in-oil)analysis using gas chromatography and other electrochemical sensors, initial researches werecompleted to realize on-line monitoring of dissolved gas-in-oil of power transformers using FTIR(Fourier Transform InfraRed) spectroscopy. Gas cell method is used to determine the characteristicabsorption peaks of each diagnostic gas; simple and novel devices and procedures were designed inorder to get measurable samples and spectra of mixed diagnostic gases with known concentration aretaken using long optical path gas cell. The range of wavelength is estimated to be 3.0-13.9 mum fromexperimental spectra data. Hence the corresponding sampling frequency range should be in 536-4288Hz and usable optical materials are suggested. It is concluded that a resolution of 10 cm^(-1) maywell satisfy the monitoring of all diagnostic gases and water content except hydrogen, and thelowest detection limit may be as low as 2Xl0^(-8) to acetylene with a 2.4-meter-long optical length. 展开更多
关键词 FTIR power transformer dissolved gas-in-oil on-line monitoring INFRAREDSPECTRA
下载PDF
On-line Condition Monitoring and Diagnostic Network System for Rotating Machine Set 被引量:1
11
作者 Li Fucai, He Zhengjia, Zi Yanyang School of Mechanical Engineering, Xi’an Jiaotong University, Xi’an 710049, P. R. China 《International Journal of Plant Engineering and Management》 2000年第4期136-141,共6页
Several industrial computers and a server are combined to set up the on-line monitoring and diagnostic system of turbo-generator sets. The main function of the system is to monitor machine sets' running condition.... Several industrial computers and a server are combined to set up the on-line monitoring and diagnostic system of turbo-generator sets. The main function of the system is to monitor machine sets' running condition. Through analyzing running data, technicians can detect whether there exist faults and where they occur. To share and transmit the dynamic information of the turbo-generator sets, a distributed network system is introduced. NetWare network operating system is used in the LAN (Local Area Network) system. The LAN is extended to realize the sharing of data and remote transmission of information. Furthermore, functions of monitoring and diagnostic clients are listed. 展开更多
关键词 rotating machine set on-line monitoring and diagnostic network system
下载PDF
On-line monitoring of insulation quality of high voltage electric power equipment
12
作者 SUN He-yi, ZHAO Xue-zeng, NIE Peng, BAI Jing-feng, YANG Yan-zhu (Harbin Institute of Technology, Harbin 150001, China) 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2000年第S1期77-80,共4页
Discusses on-line monitoring of electric parameters, such as dielectric loss, divulging current, equivalent capacitance and running voltage, and presents an on-line monitoring system of insulation quality, based on mo... Discusses on-line monitoring of electric parameters, such as dielectric loss, divulging current, equivalent capacitance and running voltage, and presents an on-line monitoring system of insulation quality, based on monitoring divulging current and dielectric loss of high voltage equipment, and its advantages, such as helping people to discover the hidden problems in a timely manner, to reduce power cut and overhaul and to improve security of power supply. 展开更多
关键词 INSULATION CAPABILITY HIGH-VOLTAGE EQUIPMENT on-line monitoring data PROCESSING
下载PDF
Research Progress of On-line Monitoring Technology for Electromagnetic Environment of Power Transmission and Transformation Projects
13
作者 Li Peiming Zhou Jian +2 位作者 Xiao Jun Wang Wenjin Ge Xiaoyang 《Meteorological and Environmental Research》 CAS 2019年第6期67-71,共5页
Based on the collection of relevant literature and cases,the research and application status of on-line monitoring technology for electromagnetic environment of power transmission and transformation projects at home a... Based on the collection of relevant literature and cases,the research and application status of on-line monitoring technology for electromagnetic environment of power transmission and transformation projects at home and abroad were introduced.Moreover,the problems existing in the on-line monitoring of electromagnetic environment were expounded,and the development prospect was forecasted. 展开更多
关键词 on-line monitoring TECHNOLOGY ELECTROMAGNETIC environment Power TRANSMISSION and TRANSFORMATION PROJECT
下载PDF
An On-line Monitoring System for Partial Dischargefrom High Voltage Transformer
14
作者 王哲 陈学允 蔡惟铮 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 1998年第2期52-56,共5页
An on-line monitoring system for partial discharge from high voltage transformer is presented with structure of hardware and principle of software discussed and a new effective method combining DFT with DWT is propose... An on-line monitoring system for partial discharge from high voltage transformer is presented with structure of hardware and principle of software discussed and a new effective method combining DFT with DWT is proposed to get rid of both sinusoidal continuous noise and other external discharges. 展开更多
关键词 Partial DISCHARGE on-line monitoring technique DISCRETE FOURIER TRANSFORM (DFT) DISCRETE WAVELET transform(DWT)
下载PDF
Real-Time Air Monitoring of Trichloroethylene and Tetrachloroethylene Using Mobile TAGA Mass Spectrometry
15
作者 Nicholas S. Karellas Qingfeng Chen 《Journal of Environmental Protection》 2013年第8期99-105,共7页
Trichloroethylene (TCE) is a chlorinated liquid that is commonly used for metal degreasing, household and industrial dry cleaning, and in paints and glues. Tetrachloroethylene, also known as perchloroethylene (PCE), i... Trichloroethylene (TCE) is a chlorinated liquid that is commonly used for metal degreasing, household and industrial dry cleaning, and in paints and glues. Tetrachloroethylene, also known as perchloroethylene (PCE), is an excellent solvent for organic materials. PCE is volatile, highly stable, non-flammable and widely used in dry cleaning. A new method has been developed for measuring TCE and PCE in ambient air in real-time. Based upon the chemical fingerprinting and concentration levels, the method was able to isolate the source of the emissions to the responsible facility. Real-time monitoring was accomplished by utilizing a low pressure chemical ionization source (LPCI) interfaced to a tandem mass spectrometer (TAGA). Monitoring the response of specific parent/daughter ion pairs, the TAGA was used to measure concentrations of TCE and PCE. By optimizing various TAGA parameters, detection limits (DL) as low as 0.5 μg/m3 was achieved for TCE and PCE. Unlike methods using cartridge sampling and GC/MS analysis, this new method provides a real time measurement for a wide range of TCE and PCE concentrations. This unique method was applied in 2000 and 2002 to measure TCE emitted from a manufacturer of stainless steel tubing in Eastern Ontario. The maximum half-hour average concentration of TCE measured downwind of the facility was 1300 μg/m3 and the maximum instantaneous level was measured at 115,000 μg/m3. The information collected by the TAGA unit was used by the Standard Development Branch of Ontario Ministry of the Environment to adopt the half-hour Point of Impingement (POI) standard of TCE to be 36 μg/m3 in 2010. This method successfully identified and simultaneously measured TCE and PCE during a 2011 air monitoring survey of a hazardous waste disposal and treatment facility in Southern Ontario. 展开更多
关键词 Environmental REAL-TIME monitoring mobile TAGA TCE and PCE Ambient Air
下载PDF
Analysis and Application of the Synthetic Relative Measuring Method in On-Line Monitoring for Capacitive Equipment in Power Systems
16
作者 Qing Guo Li-Jun Qin Hua-Wei Jin 《Journal of Electronic Science and Technology》 CAS 2011年第3期270-277,共8页
On-line measurement for dielectric loss angle can effectively monitor the insulation condition of capacitive equipment in power systems. Synthetic relative measuring methods not only markedly overcome the shortcomings... On-line measurement for dielectric loss angle can effectively monitor the insulation condition of capacitive equipment in power systems. Synthetic relative measuring methods not only markedly overcome the shortcomings of traditional absolute measuring methods but also greatly improve the accuracy of dielectric loss angle measurement. However, synthetic relative measuring methods based on two or three pieces of capacitive equipment do not have the characteristic of generality. In this paper, a principle of synthetic relative measuring method is presented. The example of application for synthetic relative methods based on three and four pieces of capacitive equipment running in the same phase is taken to present the failure judgment matrices for N pieces of equipment. According to these matrices, the fault condition of N pieces of capacitive equipment can be watched, which is more general. Then some problems needing to be concerned along with two diagnostic methods used in diagnostic system are introduced. Finally, two programmable flow charts for the two methods are given and corresponding examples demonstrate their feasibility in practice. 展开更多
关键词 Index Terms-Capacitive equipment dielectric loss angle on-line monitoring synthetic relative measuring method failure judgment matrix.
下载PDF
Insulation State On-line Monitoring and Running Management of Large Generator
17
作者 Qiudong Sun Zhengxin Zhou Weiqin Guo 《Energy and Power Engineering》 2010年第3期203-207,共5页
This study presented an insulation state monitoring method for large generator based on radio frequency (RF) technique. As an on-line condition monitor and the precondition of condition-based maintenance (CBM), the RF... This study presented an insulation state monitoring method for large generator based on radio frequency (RF) technique. As an on-line condition monitor and the precondition of condition-based maintenance (CBM), the RF monitor used the high frequency current mutual inductor to detect the partial discharge signal from neutral wire of stator windings. According to the magnitude of indicative value of RF monitor, a five phase model was also proposed to manage the generator’s running better. The practices show that the proposed method is effective. 展开更多
关键词 Large GENERATOR PARTIAL DISCHARGE RADIO Frequency Technique on-line monitoring Running MANAGEMENT
下载PDF
Wireless Distributed Monitoring Terminal Used for On-Line Application
18
作者 Fenggui Wang Lin Zhang +1 位作者 Zhongmin Wang Yanbo Zhang 《Communications and Network》 2013年第3期549-553,共5页
A wireless distributed monitoring terminal was designed with embedded Linux used on the basis of ARM board, and an application program was developed for data collection, processing and transmission. Data were collecte... A wireless distributed monitoring terminal was designed with embedded Linux used on the basis of ARM board, and an application program was developed for data collection, processing and transmission. Data were collected from the surrounding environment and transmitted to a server via WLAN in the form of Extensible Markup Language (XML) stream, so the terminal had good flexibility to be compatible with different sensors, network devices and information systems from multiple manufacturers. 展开更多
关键词 on-line monitoring DISTRIBUTED monitoring Extensible MARKUP Language (XML) STREAM WIRELESS TERMINAL
下载PDF
On-line Batch Process Monitoring and Diagnosing Based on Fisher Discriminant Analysis
19
作者 赵旭 邵惠鹤 《Journal of Shanghai Jiaotong university(Science)》 EI 2006年第3期307-312,316,共7页
A new on-line batch process monitoring and diagnosing approach based on Fisher discriminant analysis (FDA) was proposed. This method does not need to predict the future observations of variables, so it is more sensi... A new on-line batch process monitoring and diagnosing approach based on Fisher discriminant analysis (FDA) was proposed. This method does not need to predict the future observations of variables, so it is more sensitive to fault detection and stronger implement for monitoring. In order to improve the monitoring performance, the variables trajectories of batch process are separated into several blocks. The key to the proposed approach for on-line monitoring is to calculate the distance of block data that project to low-dimension Fisher space between new batch and reference batch. Comparing the distance with the predefine threshold, it can be considered whether the batch process is normal or abnormal. Fault diagnosis is performed based on the weights in fault direction calculated by FDA. The proposed method was applied to the simulation model of fed-batch penicillin fermentation and the resuits were compared with those obtained using MPCA. The simulation results clearly show that the on-line monitoring method based on FDA is more efficient than the MPCA. 展开更多
关键词 batch process on-line process monitoring fault diagnosis Fisher discriminant analysis (FDA) multiway principal component analysis (MPCA)
下载PDF
Mechanics Analysis of Overhead Transmission Lines Based On-line Monitoring
20
作者 Lili Dai Yongli Zhu Zehui Liang 《Open Journal of Applied Sciences》 2013年第2期1-4,共4页
At present, the on-line monitoring is widely applied to the power line monitoring. In this paper, a new mechanical calculation model is established according to the on-line monitoring. And this model is based on the p... At present, the on-line monitoring is widely applied to the power line monitoring. In this paper, a new mechanical calculation model is established according to the on-line monitoring. And this model is based on the parameters that tension sensors and angle sensors on suspended points detect, and combines with the parameters of the wire itself, and also considers the deflection angel of wires due to wind. In this model, mechanics parameters of wires are turned into the new coordinate plane after deflection angel of wires due to wind, or windage yaw plane. A statics tension balance equation is built in the vertical direction of the new windage yaw plane. According to the theoretical analysis and algorithm, we verify the accuracy of this newly developed mechanical calculation model. 展开更多
关键词 OVERHEAD Transmission Line on-line monitoring Mechanical ANALYSIS Tension ANGLE ICING Windage Yaw
下载PDF
上一页 1 2 77 下一页 到第
使用帮助 返回顶部