In order to improve the slurry pH control accuracy of the absorption tower in the wet flue gas desulfurization process,a model free adaptive predictive control algorithm for the desulfurization slurry pH which is base...In order to improve the slurry pH control accuracy of the absorption tower in the wet flue gas desulfurization process,a model free adaptive predictive control algorithm for the desulfurization slurry pH which is based on a cyber physical systems framework is proposed.First,aiming to address system characteristics of non-linearity and pure hysteresis in slurry pH change process,a model free adaptive predictive control algorithm based on compact form dynamic linearization is proposed by combining model free adaptive control algorithm with model predictive control algorithm.Then,by integrating information resources with the physical resources in the absorption tower slurry pH control process,an absorption tower slurry pH optimization control system based on cyber physical systems is constructed.It is turned out that the model free adaptive predictive control algorithm under the framework of the cyber physical systems can effectively realize the high-precision tracking control of the slurry pH of the absorption tower,and it has strong robustness.展开更多
In this paper,a new model free adaptive control method based on self-adjusting PID algorithm(MFACSA-PID)is proposed to solve the problem that the pH process with strong nonlinearity is difficult to control near the ne...In this paper,a new model free adaptive control method based on self-adjusting PID algorithm(MFACSA-PID)is proposed to solve the problem that the pH process with strong nonlinearity is difficult to control near the neutralization point.The MFAC-SA-PID method also solves the problem that the parameters of the model free adaptive control(MFAC)method are not easy to be adjusted and the effect is not obvious by introducing a fuzzy self-adjusting algorithm to adjust the controller parameters.Then the convergence and stability of the MFAC-SA-PID method are proved in this paper.In the simulation study,the control performance of the MFAC-SA-PID method proposed in this paper is compared with the traditional MFAC method and the improved model free adaptive control(IMFAC)method,respectively.The results show that the proposed MFAC-SA-PID method has better control effect on the pH neutralization process.The MFAC-SA-PID control performance also outperforms the traditional MFAC method and IMFAC method when step input disturbances are added,which indicates that the MFAC-SA-PID method has better robustness and stability.展开更多
基金Supported by National Natural Science Foundation of China(61873006,61673053)National Key Research and Development Project(2018YFC1602704,2018YFB1702704)。
文摘In order to improve the slurry pH control accuracy of the absorption tower in the wet flue gas desulfurization process,a model free adaptive predictive control algorithm for the desulfurization slurry pH which is based on a cyber physical systems framework is proposed.First,aiming to address system characteristics of non-linearity and pure hysteresis in slurry pH change process,a model free adaptive predictive control algorithm based on compact form dynamic linearization is proposed by combining model free adaptive control algorithm with model predictive control algorithm.Then,by integrating information resources with the physical resources in the absorption tower slurry pH control process,an absorption tower slurry pH optimization control system based on cyber physical systems is constructed.It is turned out that the model free adaptive predictive control algorithm under the framework of the cyber physical systems can effectively realize the high-precision tracking control of the slurry pH of the absorption tower,and it has strong robustness.
基金supported by the National Natural Science Foundation of China(61771034).
文摘In this paper,a new model free adaptive control method based on self-adjusting PID algorithm(MFACSA-PID)is proposed to solve the problem that the pH process with strong nonlinearity is difficult to control near the neutralization point.The MFAC-SA-PID method also solves the problem that the parameters of the model free adaptive control(MFAC)method are not easy to be adjusted and the effect is not obvious by introducing a fuzzy self-adjusting algorithm to adjust the controller parameters.Then the convergence and stability of the MFAC-SA-PID method are proved in this paper.In the simulation study,the control performance of the MFAC-SA-PID method proposed in this paper is compared with the traditional MFAC method and the improved model free adaptive control(IMFAC)method,respectively.The results show that the proposed MFAC-SA-PID method has better control effect on the pH neutralization process.The MFAC-SA-PID control performance also outperforms the traditional MFAC method and IMFAC method when step input disturbances are added,which indicates that the MFAC-SA-PID method has better robustness and stability.