期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Pole-placement self-tuning control of nonlinear Hammerstein system and its application to pH process control 被引量:1
1
作者 邹志云 赵丹丹 +4 位作者 刘兴红 郭宇晴 管臣 冯文强 郭宁 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2015年第8期1364-1368,共5页
By taking advantage of the separation characteristics of nonlinear gain and dynamic sector inside a Hammerstein model, a novel pole placement self tuning control scheme for nonlinear Hammerstein system was put forward... By taking advantage of the separation characteristics of nonlinear gain and dynamic sector inside a Hammerstein model, a novel pole placement self tuning control scheme for nonlinear Hammerstein system was put forward based on the linear system pole placement self tuning control algorithm. And the nonlinear Hammerstein system pole placement self tuning control(NL-PP-STC) algorithm was presented in detail. The identi fication ability of its parameter estimation algorithm of NL-PP-STC was analyzed, which was always identi fiable in closed loop. Two particular problems including the selection of poles and the on-line estimation of model parameters, which may be met in applications of NL-PP-STC to real process control, were discussed. The control simulation of a strong nonlinear p H neutralization process was carried out and good control performance was achieved. 展开更多
关键词 Nonlinear system Hammerstein model Pole placement Self tuning control pH control
下载PDF
Closed-loop identification of systems using hybrid Box–Jenkins structure and its application to PID tuning 被引量:1
2
作者 李全善 李大字 曹柳林 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2015年第12期1997-2004,共8页
The paper describes a closed-loop system identification procedure for hybrid continuous-time Box–Jenkins models and demonstrates how it can be used for IMC based PID controller tuning. An instrumental variable algori... The paper describes a closed-loop system identification procedure for hybrid continuous-time Box–Jenkins models and demonstrates how it can be used for IMC based PID controller tuning. An instrumental variable algorithm is used to identify hybrid continuous-time transfer function models of the Box–Jenkins form from discretetime prefiltered data, where the process model is a continuous-time transfer function, while the noise is represented as a discrete-time ARMA process. A novel penalized maximum-likelihood approach is used for estimating the discrete-time ARMA process and a circulatory noise elimination identification method is employed to estimate process model. The input–output data of a process are affected by additive circulatory noise in a closedloop. The noise-free input–output data of the process are obtained using the proposed method by removing these circulatory noise components. The process model can be achieved by using instrumental variable estimation method with prefiltered noise-free input–output data. The performance of the proposed hybrid parameter estimation scheme is evaluated by the Monte Carlo simulation analysis. Simulation results illustrate the efficacy of the proposed procedure. The methodology has been successfully applied in tuning of IMC based flow controller and a practical application demonstrates the applicability of the algorithm. 展开更多
关键词 Hybrid Box–Jenkins models ARMA models Instrumental variable Closed-loop identification PID tuning
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部