A new method to measure the average plasma velocity in a Hall-effect thruster is presented. The method is brought forward in virtue of the characteristics of low frequency oscillation induced by the propellant ionizat...A new method to measure the average plasma velocity in a Hall-effect thruster is presented. The method is brought forward in virtue of the characteristics of low frequency oscillation induced by the propellant ionization in the channel and the oriented movement feature of the plasma density out of the channel. The method, equivalent to the correlation method generally used in the signal processing field, provides a solution to the problem of specific impulse measurement on a timescale of hundreds of microseconds and makes the time evolution of average plasma velocity clear. The comparison between the measured value and the calibrated value shows that the relative error is about 3%.展开更多
基金supported by National Natural Science Foundation of China(No.50676026)
文摘A new method to measure the average plasma velocity in a Hall-effect thruster is presented. The method is brought forward in virtue of the characteristics of low frequency oscillation induced by the propellant ionization in the channel and the oriented movement feature of the plasma density out of the channel. The method, equivalent to the correlation method generally used in the signal processing field, provides a solution to the problem of specific impulse measurement on a timescale of hundreds of microseconds and makes the time evolution of average plasma velocity clear. The comparison between the measured value and the calibrated value shows that the relative error is about 3%.