期刊文献+
共找到7篇文章
< 1 >
每页显示 20 50 100
An Integrated Drive for Two PMSMs Involved Automotive Applications and Development of Current Reference Expanded Two Arm Modulation Technique 被引量:2
1
作者 V. Krishnakumar V. Kamaraj C. Adrien Perianayagam 《Circuits and Systems》 2016年第8期1794-1815,共22页
A five leg inverter (FLI) control is incorporated to drive two independent rated permanent magnet synchronous motors (PMSMs) for automotive applications. Literature evidences many attempts of employing the FLI for con... A five leg inverter (FLI) control is incorporated to drive two independent rated permanent magnet synchronous motors (PMSMs) for automotive applications. Literature evidences many attempts of employing the FLI for controlling two general purpose/special motors, where variety of modulation techniques has been practiced for performance enhancement. Also in these cases one leg of inverter is common to both the motors. The expanded two arm modulation (ETAM) has been generally engaged in FLI. In ETAM the percentage voltage utilization factor (VUF) is calculated based on “α<sub>max</sub>”, where “α<sub>max</sub>” is the maximum modulation index and equal to  and hence it restricts the VUF to 50%. This makes the FLI drives to use the dc link in inefficient way, which is due to the fact that conventional ETAM works with voltage reference. This paper modifies the ETAM in an ingenious way to improve the VUF further through current reference. In addition, the developed current reference expanded two arm modulation (CRETAM) minimizes the current harmonics and torque ripple as well. A detailed comparison of the CRETAM with the conventional ETAM and the competent digital counterpart, space vector pulse width modulation (SVPWM), is also presented. The enhancement in VUF, torque ripple minimization and current total harmonic distortion (THD) reduction are found in the MATLAB based simulation results. 展开更多
关键词 EV/HEV Traction Drive SVPWM Five Leg Inverter Two Permanent Magnet Synchronous Motor Drive current Reference Expanded Two Arm modulation (CRETAM) Expanded Two Arm modulation (ETAM)
下载PDF
The Experiment of Modulated Toroidal Current on HT-7 and HT-6M Tokamak 被引量:2
2
作者 毛剑珊 P.Phillips +12 位作者 罗家融 徐宇鸿 赵君煜 张先梅 万宝年 张守银 揭银先 吴振伟 胡立群 刘胜霞 石跃江 李建刚 HT-6M&HT-7 group 《Plasma Science and Technology》 SCIE EI CAS CSCD 2003年第1期1641-1650,共10页
The Experiments of Modulated Toroidal Current were done on the HT-6M tokamak and HT-7 superconducting tokamak. The toroidal current was modulated by programming the Ohmic heating field. Modulation of the plasma curren... The Experiments of Modulated Toroidal Current were done on the HT-6M tokamak and HT-7 superconducting tokamak. The toroidal current was modulated by programming the Ohmic heating field. Modulation of the plasma current has been used successfully to suppress MHD activity in discharges near the density limit where large MHD m = 2 tearing modes were suppressed by sufficiently large plasma current oscillations. The improved Ohmic confinement phase was observed during modulating toroidal current (MTC) on the Hefei Tokamak-6M (HT-6M) and Hefei superconducting Tokamak-7 (HT-7). A toroidal frequency-modulated current, induced by a modulated loop voltage, was added on the plasma equilibrium current. The ratio of A.C. amplitude of plasma current to the main plasma current Ip/Ip is about 12% ~ 30%. The different formats of the frequency-modulated toroidal current were compared. 展开更多
关键词 modulated toroicdal current superconducting tokamak
下载PDF
Low-dose computed tomography with 4th-generation iterative reconstruction algorithm in assessment of oncologic patients 被引量:2
3
作者 Davide Ippolito Alessandra Silvia Casiraghi +3 位作者 Cammillo Talei Franzesi Davide Fior Franca Meloni Sandro Sironi 《World Journal of Gastrointestinal Oncology》 SCIE CAS 2017年第10期423-430,共8页
AIM To compare radiation dose and image quality of lowdose computed tomography(CT) protocol combined with hybrid-iterative reconstruction algorithm with standarddose CT examinations for follow-up of oncologic patients... AIM To compare radiation dose and image quality of lowdose computed tomography(CT) protocol combined with hybrid-iterative reconstruction algorithm with standarddose CT examinations for follow-up of oncologic patients. METHODS Fifty-one patients with known malignant diseases which underwent, during clinical follow-up, both standarddose and low-dose whole-body CT scans were enrolled. Low-dose CT was performed on 256-row scanner, with 120 kV and automated m A modulation, and iterative reconstruction algorithm. Standard-dose CT was performed on 16-rows scanner, with 120 kV, 200-400 m As(depending on patient weight). We evaluated density values and signal-to-noise ratio, along with image noise(SD), sharpness and diagnostic quality with 4-point scale.RESULTS Density values in liver, spleen and aorta were higher in lowdose images(liver 112.55 HU vs 103.90 HU, P < 0.001), as SD values in liver and spleen(liver 16.81 vs 14.41). Volumetric-Computed-Tomographic-Dose-Index(CTDIvol) and Dose-Length-Product(DLP) were significantly lower in low-dose CT as compared to standard-dose(DLP 1025.6 m Gy*cm vs 1429.2 m Gy*cm, P < 0.001) with overall dose reduction of 28.9%. Qualitative analysis did not reveal significant differences in image noise and diagnostic quality.CONCLUSION Automatic tube-current modulation combined with hybriditerative algorithm allows radiation dose reduction of 28.9% without loss of diagnostic quality, being useful in reducing dose exposure in oncologic patients. 展开更多
关键词 Computed tomography Low-dose computed tomography Tube current modulation Oncologic imaging Radiation dose
下载PDF
Experimental Results of MHD Suppression with Modulated LHCD on the HT-7 Tokamak 被引量:1
4
作者 毛剑珊 罗家融 +7 位作者 沈飙 赵君煜 胡立群 徐国盛 徐汉东 沈慰慈 P.Phillips 高翔 《Plasma Science and Technology》 SCIE EI CAS CSCD 2005年第3期2816-2818,共3页
Modulation of lower hybrid current drive was used successfully to suppress MHD activity. This was achieved in discharges with MHD m = 2 tearing modes during the discharge conditions Ip = 110 kA, Bt = 1.75 T, ne0 - 1.1... Modulation of lower hybrid current drive was used successfully to suppress MHD activity. This was achieved in discharges with MHD m = 2 tearing modes during the discharge conditions Ip = 110 kA, Bt = 1.75 T, ne0 - 1.1 × 1013 cm-3. The delivering time of LHCD pulse is less then 30 μs. The amplitude, interval and the period of LHCD modulation pulse can be adjusted very conveniently. The modulation LHCD can be delivered very fast at any time during the discharge. The modulation LHCD period was always much shorter than the plasma resistive time (Tη ≈100 ms). So the profile of plasma current is changed much faster than the plasma resistive time. The different forms of LHCD modulating can be proved. 展开更多
关键词 HT-7 tokamak tearing mode modulation of lower hybrid current drive
下载PDF
Modulation of drain current as a function of energies substrate for InP HEMT devices
5
作者 S.Derrouiche B.Bouazza C.Sayah 《Journal of Semiconductors》 EI CAS CSCD 2018年第11期31-35,共5页
We present the drain current modulation for an HEMT using the TCAD SILVACO simulation tool with a drift–diffusion model at ambient temperature. The obtained results show that the decreases of substrate energies induc... We present the drain current modulation for an HEMT using the TCAD SILVACO simulation tool with a drift–diffusion model at ambient temperature. The obtained results show that the decreases of substrate energies induce the decreasing of the obtained drain current similarly to the transconductance, which described the device due to increasing the transferred electrons concentration towards the substrate region, consequently to increase the molar fraction where the concentration of transferred electrons increases from 49 × 10;to 65 × 10;cm;when the molar fraction increases from 0.1 to 0.9. On the other hand, the decrease of molar fraction from 0.9 to 0.1 induces the increasing of drain current by 63%, where it increases from 1.1 mA/mm to 3 mA/mm at V;= 0.6 V and V;= 1 V. This fact leads to ensuring the possibility of using the obtained results of this work related to drain current for producing performances devices that brings together the AC characteristics of HEMT with a weak drain current, which is important in the bioengineering domain. 展开更多
关键词 high electron mobility transistors (HEMT) electron concentration drain current modulation electron injection bio-engineering
原文传递
Novel Modular Multilevel Converter Against DC Faults for HVDC Applications 被引量:2
6
作者 Xiaofeng Yang Yao Xue +3 位作者 Bowei Chen Zhiqin Lin Trillion Q.Zheng Yan Li 《CSEE Journal of Power and Energy Systems》 SCIE 2017年第2期140-149,共10页
In view of the DC fault current isolation deficiency for the conventional half-bridge sub-module(HBSM)based modular multilevel converter(MMC),this paper presents an improved MMC topology.Both quasi reverse blocking su... In view of the DC fault current isolation deficiency for the conventional half-bridge sub-module(HBSM)based modular multilevel converter(MMC),this paper presents an improved MMC topology.Both quasi reverse blocking submodules(QRBSMs)and current limit modules(CLMs)are employed to improve the DC fault handling capability for HVDC applications.This paper analyzes such a new converter configuration and operation principles.Then the DC pole-to-pole short circuit fault is taken into consideration for further study,as well as the fault current blocking mechanism and quantitative relationship between system electrical stress and key parameters.To validate the feasibility of the proposed topology and fault protection theory,extensive simulation results are demonstrated.It is concluded that the QRB-MMC can effectively block the fault current under DC fault condition.In addition,CLMs play an important role in further accelerating fault current attenuation.Moreover,QRB-MMC employs the original control and modulation strategies under normal operation conditions;thus,it further reduces the complexity of industry design. 展开更多
关键词 current limit module DC faults HVDC transmission modular multilevel converter quasi reverse blocking sub-module
原文传递
1.5μm, 8×12.5Gb/s of hybrid-integrated TOSA with isolators and ROSA for 100GbE application 被引量:1
7
作者 赵泽平 刘宇 +3 位作者 张志珂 陈向飞 刘建国 祝宁华 《Chinese Optics Letters》 SCIE EI CAS CSCD 2016年第12期45-49,共5页
Compact transmitter and receiver optical sub-assemblies(TOSA and ROSA) are fabricated in our laboratory and have an aggregated capacity of 100 Gb/s. Specially, directly modulated laser(DML) drivers with two layers... Compact transmitter and receiver optical sub-assemblies(TOSA and ROSA) are fabricated in our laboratory and have an aggregated capacity of 100 Gb/s. Specially, directly modulated laser(DML) drivers with two layers of electrical circuit boards are designed to inject RF signals and bias currents separately. For all the lanes, the3 dB bandwidth of the cascade of the TOSA and ROSA exceeds 9 GHz, which allows the 12.5 Gb/s operation.With the 12.5 Gb/s × 8-lane operation, clear eye diagrams for back-to-back and 30-km amplified transmission with a dispersion compensation fiber are achieved. Low cost and simple processing technology make it possible to realize commercial production. 展开更多
关键词 transmitter receiver modulated crosstalk currents compensation aggregated bandwidth cascade separately
原文传递
上一页 1 下一页 到第