Effectiveness and safety of a sports mouthguard depend on its thickness and material, and the thermoforming process affects these. The purpose of this study was to clarify the effects of differences in molding mechani...Effectiveness and safety of a sports mouthguard depend on its thickness and material, and the thermoforming process affects these. The purpose of this study was to clarify the effects of differences in molding mechanisms on the lower molding temperature limit and molding time in dental thermoforming. Ethylene vinyl acetate resin mouthguard sheet and two thermoforming machines;vacuum blower molding machine and vacuum ejector/pressure molding machine were used. The molding pressures for suction molding were −0.018 MPa for vacuum blower molding and −0.090 MPa for vacuum ejector molding, and for pressure molding was set to 0.090 MPa or 0.450 MPa. Based on the manufacturer’s standard molding temperature of 95˚C, the molding temperature was lowered in 2.5˚C increments to determine the lower molding temperature limit at which no molding defects occurred. In order to investigate the difference in molding time depending on the molding mechanism, the duration of molding pressure was adjusted in each molding machine, and the molding time required to obtain a sample without molding defects was measured. The molding time of each molding machine were compared using one-way analysis of variance. The lower molding temperature limit was 90.0˚C for the vacuum blower machine, 77.5˚C for the vacuum ejector machine, 77.5˚C for the pressure molding machine at 0.090 MPa, and 67.5˚C for the pressure molding machine at 0.45 MPa. The lower molding temperature limit was higher for lower absolute values of molding pressure. The molding time was shorter for pressure molding than for suction molding. Significant differences were observed between all conditions except between the pressure molding machine at 0.090 MPa and 0.45 MPa (P < 0.01). A comparison of the differences in lower molding temperature limit and molding time due to molding mechanisms in dental thermoforming revealed that the lower molding temperature limit depends on the molding pressure and that the molding time is longer for suction molding than for pressure molding.展开更多
Low pressure sheet molding compound (LPMC,1.0-3.0 MPa,95-103 ℃) is a new kind of thermosetting material with crystalline polyester as a physical thickenner.LPMC is different from conventional SMC using an earth oxi...Low pressure sheet molding compound (LPMC,1.0-3.0 MPa,95-103 ℃) is a new kind of thermosetting material with crystalline polyester as a physical thickenner.LPMC is different from conventional SMC using an earth oxide thickening agent (e.g.MgO) as chemical thickenner,it relies on the physical thickening of crystalline polyester.Crystalline polyester resin is the key material to mold LPMC parts.Currently there was no report about the thickening mechanism of crystalline polyester in LPMC.In this article,crystalline polyester resins,whose melting points were between 45 ℃ and 89 ℃,were synthesized by a two-step esterification.The melt points of crystalline polyesters are controlled by regulating the mol ratio of the two glycols and the two acids.And by means of varying the content of crystalline polyester resin,the thickening effect on resin paste is investigated.In addition,the thickening mechanism of crystalline polyester in LPMC was investigated by FTIR and DSC analysis.The effects of the diameters and viscosity of crystalline polyester on the rheological property and fiber distribution of LPMC sheets were studied,too.Results show that the thickening effect is excellent when the weight content of crystalline polyester resin is 3%.And there exists three kinds of functions acting in the process of thickening:swelling,hydrogen bonds and induction crystallization.During the preparing process of resin paste in LPMC,the temperature of resin paste must be kept at 90 ℃.In addition,crystalline polyester make LPMC have a perfect fluid property.When the viscosity of LPMC sheet is beyond 1 kPa s,the fiber orientation is not obvious.But when the viscosity of LPMC sheet is about 500 Pa s,the fiber shows a certain degree of orientation.Moreover the study of physical and chemical thickening mechanism of crystalline polyester and the rheological discipline of LPMC sheets in the hot mould will provide the researchers and enterprises with theory guidance.展开更多
Based on a series of experiments, the theory of relationship between normal pressure and pores' characters fit for polymer was set up for the first time. On the study of relation between normal pressure and porosity,...Based on a series of experiments, the theory of relationship between normal pressure and pores' characters fit for polymer was set up for the first time. On the study of relation between normal pressure and porosity, experience model of polyimide porous materials was proposed which is similar to the traditional expe- rience model of the metal porous material. While being pressed, polyimide was found soon to come into elasto- plastic deformation progress in this paper, so the theory model of metal porous material based on Hooker's law was not fit for the polymer any more. A new elasto-plastic deformation and exhausting model is proposed which shows better agreement with polymer material's pressing process.展开更多
The correlation between the initial time value of transient iterative parameters and the blowing pressure in the numerical simulation process of blowing balloon is investigated by POLYFLOW. The results show that: 1) A...The correlation between the initial time value of transient iterative parameters and the blowing pressure in the numerical simulation process of blowing balloon is investigated by POLYFLOW. The results show that: 1) As the blow molding pressure increases, the boundary value of the iterative time step decreases rapidly at first and then slowly. At the end of the first step of iterative calculation for each boundary value, the balloon parison is in the mold core cavity. 2) If the initial time value of transient iterative parameters is smaller than the boundary value of the iterative time step, the balloon parison is still in the mold core cavity at the end of the first iteration. However, if the iterative calculation continues, the calculation process may be interrupted when the time step is smaller than the initial time value of the transient iterative parameters, which makes the blow molding simulation of balloon unable to continue. 3) It is suggested that the initial time value of transient iterative parameters is one order of magnitude smaller than the boundary value of the iterative time step to complete smoothly the simulation of blow molding balloon.展开更多
In order to investigate the sand mold strength after the aeration sand filling-high pressure squeeze moldingprocess,a tree-dimentional(3D)numerical simulation was introduced.The commercial finite element method(FEM)so...In order to investigate the sand mold strength after the aeration sand filling-high pressure squeeze moldingprocess,a tree-dimentional(3D)numerical simulation was introduced.The commercial finite element method(FEM)software ABAQUScombined with a revised Drucker-Prager/Cap model was used to simulate the squeeze compaction process.Additionally,the sand bulk density after the aeration sand filling process was tested by a specially designed experiment,which divided the whole sand bulk in the molding chamber into5x9regions and it was used as the input to simulate the squeeze process.During the simulation process,the uniform modeling simulation and the patition modeling simulation methods were used a d the3D numercal simulation results were compared with correlative benchmark testings.From the3D numerica simulation results,it can be concluded that the uniform sand bulk density distribution can obtain a high quality sandmold and the revised Drncker-Pager/Cap model is suitable for handling the situation with the complex paaern.The3D numerical simulation results can predict well the sand mold strength distribution and can be used as guidelines for the production practice.展开更多
Isotactic polypropylene(i PP) samples obtained by pressure vibration injection molding(PVIM) and conventional injection molding(CIM) were studied by polarized-light microscopy(PLM), respectively. It was found ...Isotactic polypropylene(i PP) samples obtained by pressure vibration injection molding(PVIM) and conventional injection molding(CIM) were studied by polarized-light microscopy(PLM), respectively. It was found that the alternating bright and dark banded spherulites were generated in the transitional region of PVIM parts. It is the first time that the banded spherulites of isotactic polypropylene were observed in polymer processing. What's more, the banded spherulites were proved to be constituted of α-form crystal by hot stage polarized-light microscopy(HT-PLM) and wide angle X-ray diffraction(WAXD). Morphology of the banded spherulites was also studied by scaning electronical microscopy(SEM).展开更多
A surface micro-/nano-structured metal plate can be joined with an injection molded plastic piece in a mold,which has been named injection molded direct joining(IMDJ).The injected plastic melt infiltrates the micro-/n...A surface micro-/nano-structured metal plate can be joined with an injection molded plastic piece in a mold,which has been named injection molded direct joining(IMDJ).The injected plastic melt infiltrates the micro-/nano-structure,e.g.,a porous structure with micro/nano pores,on the metal plate while flowing in the mold cavity where the metal plate is inserted.After solidification of the plastic,the metal and plastic materials are directly joined via the micro-/nano-structured metal surface.Since air is trapped by the plastic melt,it is easily imagined that the air in the mold cavity prevents the melt plastic from contacting the metal surface and infiltrating the micro-/nano-structure,which could result in poorer joining performance.To avoid the prevention of the air for the better joining performance,the present study proposes a system actively venting the mold cavity during injection molding.To apply the active venting to IMDJ,venting and sealing systems were newly developed.In addition,a system measuring air pressure of the mold cavity was developed.The proposed system was evaluated by a measurement of joining strengths of IMDJ specimens that were produced under various conditions.From the results,it is concluded that the active venting does not necessarily have a positive effect in any cases:the effect depends on the type of surface micro-/nano-structure.展开更多
文摘Effectiveness and safety of a sports mouthguard depend on its thickness and material, and the thermoforming process affects these. The purpose of this study was to clarify the effects of differences in molding mechanisms on the lower molding temperature limit and molding time in dental thermoforming. Ethylene vinyl acetate resin mouthguard sheet and two thermoforming machines;vacuum blower molding machine and vacuum ejector/pressure molding machine were used. The molding pressures for suction molding were −0.018 MPa for vacuum blower molding and −0.090 MPa for vacuum ejector molding, and for pressure molding was set to 0.090 MPa or 0.450 MPa. Based on the manufacturer’s standard molding temperature of 95˚C, the molding temperature was lowered in 2.5˚C increments to determine the lower molding temperature limit at which no molding defects occurred. In order to investigate the difference in molding time depending on the molding mechanism, the duration of molding pressure was adjusted in each molding machine, and the molding time required to obtain a sample without molding defects was measured. The molding time of each molding machine were compared using one-way analysis of variance. The lower molding temperature limit was 90.0˚C for the vacuum blower machine, 77.5˚C for the vacuum ejector machine, 77.5˚C for the pressure molding machine at 0.090 MPa, and 67.5˚C for the pressure molding machine at 0.45 MPa. The lower molding temperature limit was higher for lower absolute values of molding pressure. The molding time was shorter for pressure molding than for suction molding. Significant differences were observed between all conditions except between the pressure molding machine at 0.090 MPa and 0.45 MPa (P < 0.01). A comparison of the differences in lower molding temperature limit and molding time due to molding mechanisms in dental thermoforming revealed that the lower molding temperature limit depends on the molding pressure and that the molding time is longer for suction molding than for pressure molding.
基金supported by National Natural Science Foundation of China (Grant No. 50473013)National Hi-tech Research and Development Program of China (863 Program,Grant No. 2003AA333070)+1 种基金Hubei Provincial Natural Science Foundation of China (Grant No.2009CDA037)Researching Foundation of Hubei Automotive Industries Institute of China (Grant No. BK201001)
文摘Low pressure sheet molding compound (LPMC,1.0-3.0 MPa,95-103 ℃) is a new kind of thermosetting material with crystalline polyester as a physical thickenner.LPMC is different from conventional SMC using an earth oxide thickening agent (e.g.MgO) as chemical thickenner,it relies on the physical thickening of crystalline polyester.Crystalline polyester resin is the key material to mold LPMC parts.Currently there was no report about the thickening mechanism of crystalline polyester in LPMC.In this article,crystalline polyester resins,whose melting points were between 45 ℃ and 89 ℃,were synthesized by a two-step esterification.The melt points of crystalline polyesters are controlled by regulating the mol ratio of the two glycols and the two acids.And by means of varying the content of crystalline polyester resin,the thickening effect on resin paste is investigated.In addition,the thickening mechanism of crystalline polyester in LPMC was investigated by FTIR and DSC analysis.The effects of the diameters and viscosity of crystalline polyester on the rheological property and fiber distribution of LPMC sheets were studied,too.Results show that the thickening effect is excellent when the weight content of crystalline polyester resin is 3%.And there exists three kinds of functions acting in the process of thickening:swelling,hydrogen bonds and induction crystallization.During the preparing process of resin paste in LPMC,the temperature of resin paste must be kept at 90 ℃.In addition,crystalline polyester make LPMC have a perfect fluid property.When the viscosity of LPMC sheet is beyond 1 kPa s,the fiber orientation is not obvious.But when the viscosity of LPMC sheet is about 500 Pa s,the fiber shows a certain degree of orientation.Moreover the study of physical and chemical thickening mechanism of crystalline polyester and the rheological discipline of LPMC sheets in the hot mould will provide the researchers and enterprises with theory guidance.
文摘Based on a series of experiments, the theory of relationship between normal pressure and pores' characters fit for polymer was set up for the first time. On the study of relation between normal pressure and porosity, experience model of polyimide porous materials was proposed which is similar to the traditional expe- rience model of the metal porous material. While being pressed, polyimide was found soon to come into elasto- plastic deformation progress in this paper, so the theory model of metal porous material based on Hooker's law was not fit for the polymer any more. A new elasto-plastic deformation and exhausting model is proposed which shows better agreement with polymer material's pressing process.
文摘The correlation between the initial time value of transient iterative parameters and the blowing pressure in the numerical simulation process of blowing balloon is investigated by POLYFLOW. The results show that: 1) As the blow molding pressure increases, the boundary value of the iterative time step decreases rapidly at first and then slowly. At the end of the first step of iterative calculation for each boundary value, the balloon parison is in the mold core cavity. 2) If the initial time value of transient iterative parameters is smaller than the boundary value of the iterative time step, the balloon parison is still in the mold core cavity at the end of the first iteration. However, if the iterative calculation continues, the calculation process may be interrupted when the time step is smaller than the initial time value of the transient iterative parameters, which makes the blow molding simulation of balloon unable to continue. 3) It is suggested that the initial time value of transient iterative parameters is one order of magnitude smaller than the boundary value of the iterative time step to complete smoothly the simulation of blow molding balloon.
基金The National Natural Science Foundation of China(No.51575304)the National Science and Technology Major Project of the Ministry of Science and Technology of China(No.2012ZX04012011)
文摘In order to investigate the sand mold strength after the aeration sand filling-high pressure squeeze moldingprocess,a tree-dimentional(3D)numerical simulation was introduced.The commercial finite element method(FEM)software ABAQUScombined with a revised Drucker-Prager/Cap model was used to simulate the squeeze compaction process.Additionally,the sand bulk density after the aeration sand filling process was tested by a specially designed experiment,which divided the whole sand bulk in the molding chamber into5x9regions and it was used as the input to simulate the squeeze process.During the simulation process,the uniform modeling simulation and the patition modeling simulation methods were used a d the3D numercal simulation results were compared with correlative benchmark testings.From the3D numerica simulation results,it can be concluded that the uniform sand bulk density distribution can obtain a high quality sandmold and the revised Drncker-Pager/Cap model is suitable for handling the situation with the complex paaern.The3D numerical simulation results can predict well the sand mold strength distribution and can be used as guidelines for the production practice.
文摘Isotactic polypropylene(i PP) samples obtained by pressure vibration injection molding(PVIM) and conventional injection molding(CIM) were studied by polarized-light microscopy(PLM), respectively. It was found that the alternating bright and dark banded spherulites were generated in the transitional region of PVIM parts. It is the first time that the banded spherulites of isotactic polypropylene were observed in polymer processing. What's more, the banded spherulites were proved to be constituted of α-form crystal by hot stage polarized-light microscopy(HT-PLM) and wide angle X-ray diffraction(WAXD). Morphology of the banded spherulites was also studied by scaning electronical microscopy(SEM).
基金This study was supported by JSPS KAKENHI(#17J00345)and the Foundation for the Promotion of Industrial Science.A part of the experiments was carried out with the supports and advices of Yokoi group,the University of Tokyo,Japan.
文摘A surface micro-/nano-structured metal plate can be joined with an injection molded plastic piece in a mold,which has been named injection molded direct joining(IMDJ).The injected plastic melt infiltrates the micro-/nano-structure,e.g.,a porous structure with micro/nano pores,on the metal plate while flowing in the mold cavity where the metal plate is inserted.After solidification of the plastic,the metal and plastic materials are directly joined via the micro-/nano-structured metal surface.Since air is trapped by the plastic melt,it is easily imagined that the air in the mold cavity prevents the melt plastic from contacting the metal surface and infiltrating the micro-/nano-structure,which could result in poorer joining performance.To avoid the prevention of the air for the better joining performance,the present study proposes a system actively venting the mold cavity during injection molding.To apply the active venting to IMDJ,venting and sealing systems were newly developed.In addition,a system measuring air pressure of the mold cavity was developed.The proposed system was evaluated by a measurement of joining strengths of IMDJ specimens that were produced under various conditions.From the results,it is concluded that the active venting does not necessarily have a positive effect in any cases:the effect depends on the type of surface micro-/nano-structure.