Technological Analysis on Motor Stall and Its Perspective
1
作者 Run Xu Zhiqiang Chen 《Electrical Science & Engineering》 2020年第1期26-29,共4页
The brush lock is due to assembly tightly during assembling three gripper so that it curls after some time in motor and bare motors.The motor happen to have current decreasing and cause rotary too slowly is an importa... The brush lock is due to assembly tightly during assembling three gripper so that it curls after some time in motor and bare motors.The motor happen to have current decreasing and cause rotary too slowly is an important technique problem.At last the motor hasn’t worked due to disconnection.It give company to bring assembly issue for customers.So the motor stall is main issue in motor working.We shall pay more attention to it necessarily and shall be strict quality inspection and we shall monitor the flow line for the sake of decreasing it.We shall solve the problem as soon as possible and communicate with the customer engineers.Unloaded rotation is radical in the base inspection.The engineer need to negotiate with supplying engineers for the qualified material of brush.Increasing inspection into more times is a method to decrease unqualified brushes.Some experiment method is explained to analyze for customer engineers.Two kinds of motors ie.stepping and asynchronous motor and motors used in future in car is explained to further knowledge to motor’s application.Such as the experiment with torque,voice and electric voltage converter.The pseudo soldering results the slow rotary.The reverse voltage is a reason for a motor to slow rotary even stall. 展开更多
关键词 motor stall Assembly line Quality inspection Unloaded rotary Pseudo soldering EMI Experiment method motor use on cars in future Reverse voltage
下载PDF
英国ROTORK电动执行器“MOTOR STALLED”故障原因探讨及在线更换方案
2
作者 孙迪 《中文科技期刊数据库(文摘版)工程技术》 2021年第4期352-353,共2页
2020年,庐江公司#1、#2机组风机共发生3次风机动叶电动执行机构出现无法远控、就地电动操作现象。经检查,电动执行机构本体显示屏触发“MOTOR STALLED”电机堵转报警。本文针对以上问题对英国ROTORK电动执行机构“MOTOR STALLED”发生... 2020年,庐江公司#1、#2机组风机共发生3次风机动叶电动执行机构出现无法远控、就地电动操作现象。经检查,电动执行机构本体显示屏触发“MOTOR STALLED”电机堵转报警。本文针对以上问题对英国ROTORK电动执行机构“MOTOR STALLED”发生故障的原因进行分析并针对其在火力发电厂风机动叶电动执行机构在线更换提出可行性方案。 展开更多
关键词 ROTORK motor STALLED 固态接触器 辅助触点 电机 更换方案
下载PDF