期刊文献+
共找到9,074篇文章
< 1 2 250 >
每页显示 20 50 100
基于Unity3D的油田抽油机三维可视化监控系统设计 被引量:2
1
作者 刘立强 孙文磊 +1 位作者 王一 王炳楷 《系统仿真学报》 CAS CSCD 北大核心 2024年第2期463-475,共13页
针对抽油机监测形式单一、三维可视化程度低和联动性差的缺陷,引入信息―物理实时映射思想,开发了油田抽油机三维可视化监控系统。设计了抽油机数字空间,搭建虚实交互层设计架构;搭建三维可视化系统数据组成及关系框架;结合逆运动学,构... 针对抽油机监测形式单一、三维可视化程度低和联动性差的缺陷,引入信息―物理实时映射思想,开发了油田抽油机三维可视化监控系统。设计了抽油机数字空间,搭建虚实交互层设计架构;搭建三维可视化系统数据组成及关系框架;结合逆运动学,构建数学模型,基于五维模型和Unity 3D平台设计抽油机三维可视化系统总体架构;以游梁式抽油机为对象进行实验验证,实现了实时动态监测、虚实混合控制、运动轨迹追踪和在线预警等服务功能。为三维可视化监控在石油机械领域的落地应用和数字孪生系统的开发提供借鉴。 展开更多
关键词 抽油机 三维可视化 实时动态监测 虚实混合控制 unitY3D
下载PDF
A gated recurrent unit model to predict Poisson’s ratio using deep learning 被引量:1
2
作者 Fahd Saeed Alakbari Mysara Eissa Mohyaldinn +4 位作者 Mohammed Abdalla Ayoub Ibnelwaleed A.Hussein Ali Samer Muhsan Syahrir Ridha Abdullah Abduljabbar Salih 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2024年第1期123-135,共13页
Static Poisson’s ratio(vs)is crucial for determining geomechanical properties in petroleum applications,namely sand production.Some models have been used to predict vs;however,the published models were limited to spe... Static Poisson’s ratio(vs)is crucial for determining geomechanical properties in petroleum applications,namely sand production.Some models have been used to predict vs;however,the published models were limited to specific data ranges with an average absolute percentage relative error(AAPRE)of more than 10%.The published gated recurrent unit(GRU)models do not consider trend analysis to show physical behaviors.In this study,we aim to develop a GRU model using trend analysis and three inputs for predicting n s based on a broad range of data,n s(value of 0.1627-0.4492),bulk formation density(RHOB)(0.315-2.994 g/mL),compressional time(DTc)(44.43-186.9 μs/ft),and shear time(DTs)(72.9-341.2μ s/ft).The GRU model was evaluated using different approaches,including statistical error an-alyses.The GRU model showed the proper trends,and the model data ranges were wider than previous ones.The GRU model has the largest correlation coefficient(R)of 0.967 and the lowest AAPRE,average percent relative error(APRE),root mean square error(RMSE),and standard deviation(SD)of 3.228%,1.054%,4.389,and 0.013,respectively,compared to other models.The GRU model has a high accuracy for the different datasets:training,validation,testing,and the whole datasets with R and AAPRE values were 0.981 and 2.601%,0.966 and 3.274%,0.967 and 3.228%,and 0.977 and 2.861%,respectively.The group error analyses of all inputs show that the GRU model has less than 5% AAPRE for all input ranges,which is superior to other models that have different AAPRE values of more than 10% at various ranges of inputs. 展开更多
关键词 Static Poisson’s ratio Deep learning Gated recurrent unit(GRU) Sand control Trend analysis Geomechanical properties
下载PDF
Blockchain-Enabled Privacy Protection and Access Control Scheme Towards Sensitive Digital Assets Management
3
作者 Duan Pengfei Ma Zhaofeng +2 位作者 Zhang Yuqing Wang Jingyu Luo Shoushan 《China Communications》 SCIE CSCD 2024年第7期224-236,共13页
With the growth of requirements for data sharing,a novel business model of digital assets trading has emerged that allows data owners to sell their data for monetary gain.In the distributed ledger of blockchain,howeve... With the growth of requirements for data sharing,a novel business model of digital assets trading has emerged that allows data owners to sell their data for monetary gain.In the distributed ledger of blockchain,however,the privacy of stakeholder's identity and the confidentiality of data content are threatened.Therefore,we proposed a blockchainenabled privacy-preserving and access control scheme to address the above problems.First,the multi-channel mechanism is introduced to provide the privacy protection of distributed ledger inside the channel and achieve coarse-grained access control to digital assets.Then,we use multi-authority attribute-based encryption(MAABE)algorithm to build a fine-grained access control model for data trading in a single channel and describe its instantiation in detail.Security analysis shows that the scheme has IND-CPA secure and can provide privacy protection and collusion resistance.Compared with other schemes,our solution has better performance in privacy protection and access control.The evaluation results demonstrate its effectiveness and practicability. 展开更多
关键词 access control data trading MAABE multi-channel privacy preserving
下载PDF
A HybridManufacturing ProcessMonitoringMethod Using Stacked Gated Recurrent Unit and Random Forest
4
作者 Chao-Lung Yang Atinkut Atinafu Yilma +2 位作者 Bereket Haile Woldegiorgis Hendrik Tampubolon Hendri Sutrisno 《Intelligent Automation & Soft Computing》 2024年第2期233-254,共22页
This study proposed a new real-time manufacturing process monitoring method to monitor and detect process shifts in manufacturing operations.Since real-time production process monitoring is critical in today’s smart ... This study proposed a new real-time manufacturing process monitoring method to monitor and detect process shifts in manufacturing operations.Since real-time production process monitoring is critical in today’s smart manufacturing.The more robust the monitoring model,the more reliable a process is to be under control.In the past,many researchers have developed real-time monitoring methods to detect process shifts early.However,thesemethods have limitations in detecting process shifts as quickly as possible and handling various data volumes and varieties.In this paper,a robust monitoring model combining Gated Recurrent Unit(GRU)and Random Forest(RF)with Real-Time Contrast(RTC)called GRU-RF-RTC was proposed to detect process shifts rapidly.The effectiveness of the proposed GRU-RF-RTC model is first evaluated using multivariate normal and nonnormal distribution datasets.Then,to prove the applicability of the proposed model in a realmanufacturing setting,the model was evaluated using real-world normal and non-normal problems.The results demonstrate that the proposed GRU-RF-RTC outperforms other methods in detecting process shifts quickly with the lowest average out-of-control run length(ARL1)in all synthesis and real-world problems under normal and non-normal cases.The experiment results on real-world problems highlight the significance of the proposed GRU-RF-RTC model in modern manufacturing process monitoring applications.The result reveals that the proposed method improves the shift detection capability by 42.14%in normal and 43.64%in gamma distribution problems. 展开更多
关键词 Smart manufacturing process monitoring quality control gated recurrent unit neural network random forest
下载PDF
Research on the Application of Evidence-Based Quality Control Circle to Improve the Implementation Rate of Airway Management Measures in Adult Critically Ill Patients
5
作者 Yujiao Yan Jing Wu +4 位作者 Juan Liu Yanting Yuan Lixin Liu Huaxin Ye Juan Ding 《Yangtze Medicine》 2024年第1期8-19,共12页
Objective: To explore the effect of evidence-based quality control circle (QCC) in improving the implementation rate of airway management measures in adult critically ill patients. Methods: Based on the Joanna Briggs ... Objective: To explore the effect of evidence-based quality control circle (QCC) in improving the implementation rate of airway management measures in adult critically ill patients. Methods: Based on the Joanna Briggs Institute (JBI) evidence-based health care model, the best evidence of airway management in adult critically ill patients was obtained and applied to the clinic. Results: The total implementation rate of airway management measures in adult critically ill patients increased from 23.62% before the implementation of quality control circle to 88.82%, and the pulmonary infection rate in critically ill patients decreased from 42.31% to 21.74%, with statistical significance between the two groups (P 0.05). Conclusion: Evidence-based quality control circle activities can standardize the practice standards of airway management in critically ill patients, reduce the occurrence of patients’ airway related complications, and improve clinical outcomes. 展开更多
关键词 Critically Ill Patients Airway Management Be Evidence-Based Quality control Circle Intensive Care unit (ICU)
下载PDF
有效避免ABB UNITROL 6800励磁系统故障导致机组跳闸的方案
6
作者 王赟 《上海节能》 2024年第7期1187-1195,共9页
ABB UNITROL 6800拥有多重冗余和多CPU配置,通道最大可达三通道。整个控制系统配有两套恒机端电压控制(AVR)、两套恒励磁电流控制(FCR)和一套备用恒励磁电流控制(BFCR),高冗余度的设计和彼此间的合理切换大大地提高了机组运行的安全性... ABB UNITROL 6800拥有多重冗余和多CPU配置,通道最大可达三通道。整个控制系统配有两套恒机端电压控制(AVR)、两套恒励磁电流控制(FCR)和一套备用恒励磁电流控制(BFCR),高冗余度的设计和彼此间的合理切换大大地提高了机组运行的安全性和可靠性,但ABB UNITROL 6800励磁系统测量板(CCM)本身存在一个概率极小的故障,且动作权限最高,一旦发生,将直接导致机组跳闸。介绍了一种有效避免因CCM板故障导致机组跳闸的优化方案。 展开更多
关键词 励磁系统 测量板(CCM) 极小概率故障 机组跳闸
下载PDF
Multi-model Predictive Control of Ultra-supercritical Coal-fired Power Unit 被引量:6
7
作者 王国良 阎威武 +2 位作者 陈世和 张曦 邵惠鹤 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2014年第7期782-787,共6页
The control of ultra-supercritical(USC) power unit is a difficult issue for its characteristic of the nonlinearity, large dead time and coupling of the unit. In this paper, model predictive control(MPC) based on multi... The control of ultra-supercritical(USC) power unit is a difficult issue for its characteristic of the nonlinearity, large dead time and coupling of the unit. In this paper, model predictive control(MPC) based on multi-model and double layered optimization is introduced for coordinated control of USC unit. The linear programming(LP) combined with quadratic programming(QP) is used in steady optimization for computation of the ideal value of dynamic optimization. Three inputs(i.e. valve opening, coal flow and feedwater flow) are employed to control three outputs(i.e. load, main steam temperature and main steam pressure). The step response models for the dynamic matrix control(DMC) are constructed using the three inputs and the three outputs. Piecewise models are built at selected operation points. Double-layered multi-model predictive controller is implemented in simulation with satisfactory performance. 展开更多
关键词 Ultra-supercritical power unit Coordinated control Multi-model constrained predictive control
下载PDF
MULTIPLE ELECTRONIC CONTROL UNITS CALIBRATION SYSTEM BASED ON EXPLICIT CALIBRATION PROTOCOL AND J1939 PROTOCOL 被引量:3
8
作者 ZHU Keqing XU Quankui YANG Lin ZHUO Bin 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2008年第1期42-46,共5页
The rising number of electronic control units (ECUs) in vehicles and the decreasing time to market have led to the need for advanced methods of calibration. A multi-ECU calibration system was developed based on the ... The rising number of electronic control units (ECUs) in vehicles and the decreasing time to market have led to the need for advanced methods of calibration. A multi-ECU calibration system was developed based on the explicit calibration protocol (XCP) and J1939 communication protocol to satisfy the need of calibrating multiple ECUs simultaneously. The messages in the controller area network (CAN) are defined in the J1939 protocol. Each CAN node can get its own calibration messages and information from other ECUs, and block other messages by qualifying the CAN messages with priority, source or destination address. The data field of the calibration message is designed with the XCP, with CAN acting as the transport layer. The calibration sessions are setup with the event-triggered XCP driver in the master node and the responding XCP driver in the slave nodes. Mirroring calibration variables from ROM to RAM enables the user to calibrate ECUs online. The application example shows that the multi-ECU calibration system can calibrate multiple ECUs simultaneously, and the main program can also accomplish its calculation and send commands to the actuators in time. By the multi-ECU calibration system, the calibration effort and time can be reduced and the variables in ECU can get a better match with the variables of other ECUs. 展开更多
关键词 Electronic control unit (ECU) Calibration Explicit calibration protocol (XCP) J1939 communication protocol controlled area network (CAN)
下载PDF
Incremental multivariable predictive functional control and its application in a gas fractionation unit 被引量:3
9
作者 施惠元 苏成利 +3 位作者 曹江涛 李平 宋英莉 李宁波 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第12期4653-4668,共16页
The control of gas fractionation unit(GFU) in petroleum industry is very difficult due to multivariable characteristics and a large time delay.PID controllers are still applied in most industry processes.However,the t... The control of gas fractionation unit(GFU) in petroleum industry is very difficult due to multivariable characteristics and a large time delay.PID controllers are still applied in most industry processes.However,the traditional PID control has been proven not sufficient and capable for this particular petro-chemical process.In this work,an incremental multivariable predictive functional control(IMPFC) algorithm was proposed with less online computation,great precision and fast response.An incremental transfer function matrix model was set up through the step-response data,and predictive outputs were deduced with the theory of single-value optimization.The results show that the method can optimize the incremental control variable and reject the constraint of the incremental control variable with the positional predictive functional control algorithm,and thereby making the control variable smoother.The predictive output error and future set-point were approximated by a polynomial,which can overcome the problem under the model mismatch and make the predictive outputs track the reference trajectory.Then,the design of incremental multivariable predictive functional control was studied.Simulation and application results show that the proposed control strategy is effective and feasible to improve control performance and robustness of process. 展开更多
关键词 gas fractionation unit multivariable process incremental predictive functional control
下载PDF
Nonlinear inversion-based output tracking control of a boiler-turbine unit 被引量:2
10
作者 Fang FANG Jizhen LIU Wen TAN 《控制理论与应用(英文版)》 EI 2005年第4期415-421,共7页
The capability to perform fast load-following has been an important issue in the power industry. An output tracking control system of a boiler-turbine unit is developed. The system is composed of stable inversion and ... The capability to perform fast load-following has been an important issue in the power industry. An output tracking control system of a boiler-turbine unit is developed. The system is composed of stable inversion and feedback controller. The stable inversion is implemented as a feedforward controller to improve the load-following capability, and the feedback controller is utilized to guarantee the stability and robustness of the whole system. Loop-shaping H∞ method is used to design the feedback controller and the final controller is reduced to a multivariable PI form. The output tracking control system takes account of the multivariable, nonlinear and coupling behavior of boiler-turbine system, and the simulation tests show that the control system works well and can be widely applied. 展开更多
关键词 Nonlinear stable inversion Output tracking control Feedford-feedback control Boiler-turbine unit
下载PDF
Force Control Compensation Method with Variable Load Stiffness and Damping of the Hydraulic Drive Unit Force Control System 被引量:10
11
作者 KONG Xiangdong BA Kaixian +3 位作者 YU Bin CAO Yuan ZHU Qixin ZHAO Hualong 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2016年第3期454-464,共11页
Each joint of hydraulic drive quadruped robot is driven by the hydraulic drive unit(HDU), and the contacting between the robot foot end and the ground is complex and variable, which increases the difficulty of force... Each joint of hydraulic drive quadruped robot is driven by the hydraulic drive unit(HDU), and the contacting between the robot foot end and the ground is complex and variable, which increases the difficulty of force control inevitably. In the recent years, although many scholars researched some control methods such as disturbance rejection control, parameter self-adaptive control, impedance control and so on, to improve the force control performance of HDU, the robustness of the force control still needs improving. Therefore, how to simulate the complex and variable load characteristics of the environment structure and how to ensure HDU having excellent force control performance with the complex and variable load characteristics are key issues to be solved in this paper. The force control system mathematic model of HDU is established by the mechanism modeling method, and the theoretical models of a novel force control compensation method and a load characteristics simulation method under different environment structures are derived, considering the dynamic characteristics of the load stiffness and the load damping under different environment structures. Then, simulation effects of the variable load stiffness and load damping under the step and sinusoidal load force are analyzed experimentally on the HDU force control performance test platform, which provides the foundation for the force control compensation experiment research. In addition, the optimized PID control parameters are designed to make the HDU have better force control performance with suitable load stiffness and load damping, under which the force control compensation method is introduced, and the robustness of the force control system with several constant load characteristics and the variable load characteristics respectively are comparatively analyzed by experiment. The research results indicate that if the load characteristics are known, the force control compensation method presented in this paper has positive compensation effects on the load characteristics variation, i.e., this method decreases the effects of the load characteristics variation on the force control performance and enhances the force control system robustness with the constant PID parameters, thereby, the online PID parameters tuning control method which is complex needs not be adopted. All the above research provides theoretical and experimental foundation for the force control method of the quadruped robot joints with high robustness. 展开更多
关键词 quadruped robot force control system hydraulic drive unit force control compensation method variable load stiffness and damping simulation
下载PDF
Multi-channel 28-GHz millimeter-wave signal generation on a silicon photonic chip with automated polarization control 被引量:2
12
作者 Ruiyuan Cao Yu He +4 位作者 Qingming Zhu Jingchi Li Shaohua An Yong Zhang Yikai Su 《Journal of Semiconductors》 EI CAS CSCD 2019年第5期33-39,共7页
We propose and experimentally demonstrate an integrated silicon photonic scheme to generate multi-channel millimeter-wave(MMW) signals for 5 G multi-user applications. The fabricated silicon photonic chip has a footpr... We propose and experimentally demonstrate an integrated silicon photonic scheme to generate multi-channel millimeter-wave(MMW) signals for 5 G multi-user applications. The fabricated silicon photonic chip has a footprint of 1.1 × 2.1 mm^2 and integrates 7 independent channels each having on-chip polarization control and heterodyne mixing functions. 7 channels of4-Gb/s QPSK baseband signals are delivered via a 2-km multi-core fiber(MCF) and coupled into the chip with a local oscillator(LO) light. The polarization state of each signal light is automatically adjusted and aligned with that of the LO light, and then 7 channels of 28-GHz MMW carrying 4-Gb/s QPSK signals are generated by optical heterodyne beating. Automated polarizationcontrol function of each channel is also demonstrated with ~7-ms tuning time and ~27-dB extinction ratio. 展开更多
关键词 multi-channel millimeter-wave(MMW) generation SILICON PHOTONIC integrated circuits SILICON polarization control(SPC)
下载PDF
ESO-based decoupling control with multi-objective optimization for boiler-turbine unit 被引量:3
13
作者 Zhu Jianzhong Wu Xiao Shen Jiong 《Journal of Southeast University(English Edition)》 EI CAS 2019年第1期64-71,共8页
A model-assistant extended state observer(MESO)-based decoupling control strategy is proposed for boiler-turbine units in the presence of unknown external disturbance and model-plant mismatch. For ease of implementati... A model-assistant extended state observer(MESO)-based decoupling control strategy is proposed for boiler-turbine units in the presence of unknown external disturbance and model-plant mismatch. For ease of implementation, the decoupling compensator is reduced to the proportion integration(PI) decoupler with the frequency domain analysis, where the decoupling error in collusion of uncertainties and disturbances can be estimated by the proposed MESO and then compensated. To decrease the sensitivity of the dynamic error for the decoupling control and fulfill various requirements of constraints, such as safety operation, energy conservation, emission reduction, etc., the plant is transmitted through a scheduled steady state region which is achieved from the optimized reference governor in advance. Simulation results show that the proposed control strategy can well suppress various disturbances including a decoupling error, and multi-objective optimization can meet multiple requirements with the premise of safety production. 展开更多
关键词 boiler-turbine unit extended state observer(ESO) decoupling control multi-objective optimization
下载PDF
IMPROVE THE KINETIC PERFORMANCE OF THE PUMP CONTROLLED CLAMPING UNIT IN PLASTIC INJECTION MOLDING MACHINE WITH ADAPTIVE CONTROL STRATEGY 被引量:3
14
作者 QUAN Long LIU Shiping 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2006年第1期9-13,共5页
The kinetic characteristics of the clamping unit of plastic injection molding machine that is controlled by close loop with newly developed double speed variable pump unit are investigated. Considering the wide variat... The kinetic characteristics of the clamping unit of plastic injection molding machine that is controlled by close loop with newly developed double speed variable pump unit are investigated. Considering the wide variation of the cylinder equivalent mass caused by the transmission ratio of clamping unit and the severe instantaneous impact force acted on the cylinder during the mold closing and opening process, an adaptive control principle of parameter and structure is proposed to improve its kinetic performance. The adaptive correlation between the acceleration feedback gain and the variable mass is derived. The pressure differential feedback is introduced to improve the dynamic performance in the case of small inertia and heavy impact load. The adaptation of sum pressure to load is used to reduce the energy loss of the system. The research results are verified by the simulation and experiment, The investigation method and the conclusions are also suitable for the differential cylinder system controlled by the traditional servo pump unit. 展开更多
关键词 Adaptive control Pump controlled system Clamping unit Plastic injection molding machine
下载PDF
Hardware-in-the-Loop Research on the Electronic Control Unit for Diesel Engines 被引量:1
15
作者 王宇明 张付军 +1 位作者 王永庭 刘波澜 《Journal of Beijing Institute of Technology》 EI CAS 2009年第4期416-421,共6页
A hardware-in-the-loop simulating platform is developed to avoid designing defects caused by the complicated logical structure and multiple-functional buildup of the dectronic control unit(ECU)in modem diesel engine... A hardware-in-the-loop simulating platform is developed to avoid designing defects caused by the complicated logical structure and multiple-functional buildup of the dectronic control unit(ECU)in modem diesel engines, and to diminish potential damages on components or human exposure to dangers in R&D en- deavor. This plat-form consists of a computer installed with software Matlab/Simulink/RTW and dSPACE/ ControlDesk; a diesel engine ECU, and a dSPACE autobox which runs a real-time diesel engine model. A typical model of diesel engine with turbocharger and intercooler is presented. Based on this model our research is carried out with a real ECU to test its software control strategies. Results show that by using the diesel engine model downloaded inside, the hardware-in-the-loop platform can simulate diesel engine's working conditions and generate all kinds of sensor signals which ECU needs on a real-time basis. So the ECU control strategies can be validated and relevant parameters roughly calibrated. 展开更多
关键词 electronic control unit (ECU) diesel engine real-time model DSPACE hardware-in-the-loop simulation
下载PDF
Coordinated Controller Tuning of a Boiler Turbine Unit with New Binary Particle Swarm Optimization Algorithm 被引量:1
16
作者 Muhammad Ilyas Menhas Ling Wang +1 位作者 Min-Rui Fei Cheng-Xi Ma 《International Journal of Automation and computing》 EI 2011年第2期185-192,共8页
Coordinated controller tuning of the boiler turbine unit is a challenging task due to the nonlinear and coupling characteristics of the system.In this paper,a new variant of binary particle swarm optimization (PSO) ... Coordinated controller tuning of the boiler turbine unit is a challenging task due to the nonlinear and coupling characteristics of the system.In this paper,a new variant of binary particle swarm optimization (PSO) algorithm,called probability based binary PSO (PBPSO),is presented to tune the parameters of a coordinated controller.The simulation results show that PBPSO can effectively optimize the control parameters and achieves better control performance than those based on standard discrete binary PSO,modified binary PSO,and standard continuous PSO. 展开更多
关键词 Coordinated control boiler turbine unit particle swarm optimization (PSO) probability based binary particle swarm optimization (PBPSO) controller tuning.
下载PDF
Pressure control strategy for pump motor energy transfer unit 被引量:2
17
作者 Yao Jing Zhang Wei +2 位作者 Cao Xiaoming Zhao Guichun Sun Menghui 《High Technology Letters》 EI CAS 2019年第3期286-293,共8页
Multi-level pressure source system is a novel hydraulic system with distinct advantage of energy saving. In order to balance each pressure level of the multi-level pressure source system, a pump motor energy transfer ... Multi-level pressure source system is a novel hydraulic system with distinct advantage of energy saving. In order to balance each pressure level of the multi-level pressure source system, a pump motor energy transfer unit is usually equipped. However, the pump motor energy transfer has the characteristics of poor starting and low response, which cause long time of pressure adjustment and large pressure jitter when the transformer is switched to system suddenly and the motor-side pressure has pressure impact when rail of the pump-side is switched. To address these problems, this paper proposes a compound control strategy of feedforward compensation control with Fuzzy-PID to improve the controllability of the multi-level pressure source system. A test rig of the pump motor energy transfer unit is built and the controllability of compound controller and PID controller are compared. The experiment results show that, compared with the traditional PID, the adjustment time and the pressure impact are reduced by 20% and 25% with the proposed compound control strategy. Therefore, the presented compound control strategy can be used to improve starting performance and robustness of the pump motor energy transfer unit control system. 展开更多
关键词 hydraulic system pump-motor energy transfer unit pressure control energy saving
下载PDF
Flow Calculation of Water Environmental Capacity Controlling Units in a Small Watershed Based on GIS Technology 被引量:1
18
作者 LIU Chun-xiao WANG Li ZHANG Pei 《Meteorological and Environmental Research》 CAS 2012年第3期42-45,共4页
[Objeetive] We aimed to calculate the flow of controlling units in a small watershed based on GIS technology. [Method] Hydrologic analysis on Qingyi River was conducted by using ArcGIS9.0, and the controlling units wi... [Objeetive] We aimed to calculate the flow of controlling units in a small watershed based on GIS technology. [Method] Hydrologic analysis on Qingyi River was conducted by using ArcGIS9.0, and the controlling units with response of water-land were divided according to the riv- er monitoring sections of Xuchang City; considering the wastewater entering the river and the water from its upper reach, the runoff of controlling sections in the driest month ( with guarantee rate of 90% ) was calculated by means of isoline, runoff coefficient and hydrologic analogy method, and the calculated value of Gaocun Bridge section in Linying was contrasted with the measured value in 2010. [Result] The results showed that the cal- culated value and measured value of Gaecun Bridge section in Linying in the driest month of 2010 were 6.03 and 5.93 m^3/s respectively, with relative error of 1.69%, which revealed that the result of calculated runoff was reasonable. [ Conclusion] The way to divide controlling units was reason- able, and the calculation result of runoff was accurate and can meet the precision of water environment capacity calculation. 展开更多
关键词 Water environmental capacity controlling unit Runoff calculation China
下载PDF
Design of 32 kbit one-time programmable memory for microcontroller units 被引量:1
19
作者 JEON Hwang-gon CHOI In-hwa +1 位作者 HA Pan-bong KIM Young-hee 《Journal of Central South University》 SCIE EI CAS 2012年第12期3475-3483,共9页
A 32 kbit OTP(one-time programmable)memory for MCUs(micro-controller units)used in remote controllers was designed.This OTP memory is used for program and data storage.It is required to apply 5.5V to BL(bit-line)and 1... A 32 kbit OTP(one-time programmable)memory for MCUs(micro-controller units)used in remote controllers was designed.This OTP memory is used for program and data storage.It is required to apply 5.5V to BL(bit-line)and 11V to WL(word-line)for a OTP cell of 0.35μm ETOX(EEPROM tunnel oxide)type by MagnaChip.We use 5V transistors on column data paths to reduce the area of column data paths since they require small areas.In addition,we secure device reliability by using HV(high-voltage)transistors in the WL driver.Furthermore,we change from a static logic to a dynamic logic used for the WL driver in the core circuit.Also,we optimize the WD(write data)switch circuit.Thus,we can implement them with a small-area design.In addition,we implement the address predecoder with a small-area logic circuit.The area of the designed 32 kbit OTP with 5V and HV devices is 674.725μm×258.75μm(=0.1745mm2)and is 56.3% smaller than that using 3.3V devices. 展开更多
关键词 one-time programmable memory micro controller unit EEPROM tunnel oxide small-area
下载PDF
MicroGrid Designer:user-friendly design,operation and control assist tools for resilient microgrid and autonomous community 被引量:2
20
作者 Ryuichi Yokoyama Yicheng Zhou 《Global Energy Interconnection》 EI CAS CSCD 2022年第3期249-258,共10页
During this decade,many countries have experienced natural and accidental disasters,such as typhoons,floods,earthquakes,and nuclear plant accidents,causing catastrophic damage to infrastructures.Since the end of 2019,... During this decade,many countries have experienced natural and accidental disasters,such as typhoons,floods,earthquakes,and nuclear plant accidents,causing catastrophic damage to infrastructures.Since the end of 2019,all countries of the world are struggling with the COVID-19 and pursuing countermeasures,including inoculation of vaccine,and changes in our lifestyle and social structures.All these experiences have made the residents in the affected regions keenly aware of the need for new infrastructures that are resilient and autonomous,so that vital lifelines are secured during calamities.A paradigm shift has been taking place toward reorganizing the energy social service management in many countries,including Japan,by effective use of sustainable energy and new supply schemes.However,such new power sources and supply schemes would affect the power grid through intermittency of power output and the deterioration of power quality and service.Therefore,new social infrastructures and novel management systems to supply energy and social service will be required.In this paper,user-friendly design,operation and control assist tools for resilient microgrids and autonomous communities are proposed and applied to the standard microgrid to verify its effectiveness and performance. 展开更多
关键词 MICROGRID Autonomous community Grid design and analysis RESILIENCE unit commitment Economic load dispatch Load frequency control Dynamic power flow Energy management system
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部