A dedicated weak current measurement system was designed to measure the weak currents generated by the neutron ionization chamber.This system incorporates a second-order low-pass filter circuit and the Kalman filterin...A dedicated weak current measurement system was designed to measure the weak currents generated by the neutron ionization chamber.This system incorporates a second-order low-pass filter circuit and the Kalman filtering algorithm to effectively filter out noise and minimize interference in the measurement results.Testing conducted under normal temperature conditions has demonstrated the system's high precision performance.However,it was observed that temperature variations can affect the measurement performance.Data were collected across temperatures ranging from -20 to 70℃,and a temperature correction model was established through linear regression fitting to address this issue.The feasibility of the temperature correction model was confirmed at temperatures of -5 and 40℃,where relative errors remained below 0.1% after applying the temperature correction.The research indicates that the designed measurement system exhibits excellent temperature adaptability and high precision,making it particularly suitable for measuring weak currents.展开更多
We demonstrate an experimental method for the in situ temperature measurement of atomic vapor using the saturated absorption spectrum. By separately manipulating the frequency of the pump and probe beams, the position...We demonstrate an experimental method for the in situ temperature measurement of atomic vapor using the saturated absorption spectrum. By separately manipulating the frequency of the pump and probe beams, the position of the crossover peaks can move along the spectrum. Different velocity classes of atoms contribute to the crossover during the movement. We study the relationship between the intensity change of peaks and vapor temperature. Our experimental result around room temperature shows a deviation of less than 0.3 K. Compared with traditional thermometry using absorption spectroscopy, higher accuracy can theoretically be achieved with real-time thermometry.展开更多
The function,features,and architecture of a robot that performs automatic temperature measurement and sampling applied on a 150-t AC electric arc furnace(EAF)production line of Baosteel were presented,and the key poin...The function,features,and architecture of a robot that performs automatic temperature measurement and sampling applied on a 150-t AC electric arc furnace(EAF)production line of Baosteel were presented,and the key points of design and revamping experience on the site layout,device protection,lance tool,probe container,measuring position control,and system safety were summarized.Furthermore,a valuable reference for the application of automatic temperature measuring and sampling robots in EAF steelmaking plants will be provided.展开更多
Abrupt near-surface temperature changes in mountainous areas are a special component of the mountain climate system.Fast and accurate measurements of the locations,intensity,and width of the near-surface changes are n...Abrupt near-surface temperature changes in mountainous areas are a special component of the mountain climate system.Fast and accurate measurements of the locations,intensity,and width of the near-surface changes are necessary but highly difficult due to the complicated environmental conditions and instrumental issues.This paper develops a spatial pattern recognition method to measure the near-surface high temperature increase(NSHTI),one of the lesser-attended changes.First,raster window measurement was proposed to calculate the temperature lapse rate using MODIS land surface temperature and SRTM DEM data.It fully considers the terrain heights of two neighboring cells on opposite or adjacent slopes with a moving window of 3×3 cell size.Second,a threshold selection was performed to identify the NSHTI cells using a threshold of-0.65℃/100 m.Then,the NSHTI strips were parameterized through raster vectorization and spatial analysis.Taking Yunnan,a mountainous province in southwestern China,as the study area,the results indicate that the NSHTI cells concentrate in a strip-like pattern along the mountains and valleys,and the strips are almost parallel to the altitude contours with a slight northward uplift.Also,they are located mostly at a 3/5 height of high mountains or within 400 m from the valley floors,where the controlling topographic index is the altitude of the terrain trend surface but not the absolute elevation and the topographic uplift height and cutting depth.Additionally,the NSHTI intensity varies with the geographic locations and the proportions increase with an exponential trend,and the horizontal width has a mean of about 1000 m and a maximum of over 5000 m.The result demonstrates that the proposed method can effectively recognize NSHTI boundaries over mountains,providing support for the modeling of weather and climate systems and the development of mountain resources.展开更多
Non-equilibrium radiation measurements behind strong shock wave for simulated Martian atmosphere are presented in this paper. The shock wave is established in a hydrogen oxygen combustion driven shock tube. Time- reso...Non-equilibrium radiation measurements behind strong shock wave for simulated Martian atmosphere are presented in this paper. The shock wave is established in a hydrogen oxygen combustion driven shock tube. Time- resolved spectra of the Av = 0 sequence of the B^2∑^+ → X^2∑^+ electronic transition of CN have been observed through optical emission spectroscopy (OES). A new method, which is based on fitting high resolution spectrum for rotational and vibrational temperatures measurement, is proposed to diag- nose temperature distribution behind the shock wave. It is estimated that the current scheme has the maximum deviation less than 8% (lσ) for vibrational temperature measurement through detailed analysis of the influence of the uncertainties of spectroscopic constants and spectral resolution. Radiation structure of the shock layer, including induction, relaxation and equilibrium process, and corresponding rotational and vibrational temperatures are obtained through time gating OES diagnostics with sub-microsecond temporal resolution. The present extensive results will strongly benefit the reaction rate estimation and computational fluid dynamics (CFD) code validation in high enthalpy Mars reentry chemistry.展开更多
Laminaria japonica, Undaria pinnatifida, Ulva lactuca, Grateloupia turuturu and Palmaria palmata are suitable species that fit the requirements of a seaweed-animal integrated aquaculture system in terms of their viabl...Laminaria japonica, Undaria pinnatifida, Ulva lactuca, Grateloupia turuturu and Palmaria palmata are suitable species that fit the requirements of a seaweed-animal integrated aquaculture system in terms of their viable biomass, rapid growth and promising nutrient uptake rates. In this investigation, the responses of the optimal chlorophyll fluorescence yield of the five algal species in tumble culture were assessed at a temperature range of 10 - 30℃. The results revealed that Ulva lactuca was the most resistant species to high temperature, withstanding 30℃ for 4 h without apparent decline in the optimal chlorophyll fluorescence yield . While the arctic alga Palmaria palmata was the most vulnerable one, showing significant decline in the optimal chlorophyll fluorescence yield at 25℃ for 2 h. The cold-water species Laminaria japonica, however, demonstrated strong ability to cope with higher temperature (24 -26℃ ) for shorter time (within 24 h) without significant decline in the optimal chlorophyll fluorescence yield . Grateloupia turuturu showed a general decrease in the optimal chlorophyll fluorescence yield with the rising temperature from 23 to 30℃ , similar to the temperate kelp Undaria pinnatifida. Changes of chlorophyll fluorescence yields of these algae were characterized differently indicating the existence of species-unique strategy to cope with high light. Measurements of the optimal chlorophyll fluorescence yield after short exposure to direct solar irradiance revealed how long these exposures could be without significant photoinhibition or with promising recovery in photosynthetic activities. Seasonal pattern of alternation of algal species in tank culture in the Northern Hemisphere at the latitude of 36°N was proposed according to these basic measurements.展开更多
The plastic work-heat conversion coefficient is one key parameter for studying the work-heat conversion under dynamic deformation of materials. To explore this coefficient of 7075-T651 aluminum alloy under dynamic com...The plastic work-heat conversion coefficient is one key parameter for studying the work-heat conversion under dynamic deformation of materials. To explore this coefficient of 7075-T651 aluminum alloy under dynamic compression, dynamic compression experiments using the Hopkinson bar under four groups of strain rates were conducted, and the temperature signals were measured by constructing a transient infrared temperature measurement system. According to stress versus strain data as well as the corresponding temperature data obtained through the experiments, the influences of the strain and the strain rate on the coefficient of plastic work converted to heat were analyzed.The experimental results show that the coefficient of plastic work converted to heat of 7075-T651 aluminum alloy is not a constant at the range of 0.85–1 and is closely related to the strain and the strain rate. The change of internal structure of material under high strain rate reduces its energy storage capacity, and makes almost all plastic work convert into heat.展开更多
A novel method based on wavelength-multiplexed line-of-sight absorption and profile fitting for nonuniform flow field measurement is reported. A wavelength scanning combing laser temperature and current modulation WMS...A novel method based on wavelength-multiplexed line-of-sight absorption and profile fitting for nonuniform flow field measurement is reported. A wavelength scanning combing laser temperature and current modulation WMS scheme is used to implement the wavelength-multi- plexed-profile fitting method. Second harmonic (2f) signal of eight H20 transitions features near 7,170 cm^-1 are measured in one period using a single tunable diode laser. Spatial resolved temperature distribution upon a CH4/air premixed flat flame burner is obtained. The result validates the feasibility of strategy for non-uniform flow field diagnostics by means of WMS-2f TDLAS.展开更多
Assimilation systems absorb both satellite measurements and Argo observations.This assimilation is essential to diagnose and evaluate the contribution from each type of data to the reconstructed analysis,allowing for ...Assimilation systems absorb both satellite measurements and Argo observations.This assimilation is essential to diagnose and evaluate the contribution from each type of data to the reconstructed analysis,allowing for better configuration of assimilation parameters.To achieve this,two comparative reconstruction schemes were designed under the optimal interpolation framework.Using a static scheme,an in situ-only field of ocean temperature was derived by correcting climatology with only Argo profiles.Through a dynamic scheme,a synthetic field was first derived from only satellite sea surface height and sea surface temperature measurements through vertical projection,and then a combined field was reconstructed by correcting the synthetic field with in situ profiles.For both schemes,a diagnostic iterative method was performed to optimize the background and observation error covariance statics.The root mean square difference(RMSD)of the in situ-only field,synthetic field and combined field were analyzed toward assimilated observations and independent observations,respectively.The rationale behind the distribution of RMSD was discussed using the following diagnostics:(1)The synthetic field has a smaller RMSD within the global mixed layer and extratropical deep waters,as in the Northwest Pacific Ocean;this is controlled by the explained variance of the vertical surface-underwater regression that reflects the ocean upper mixing and interior baroclinicity.(2)The in situ-only field has a smaller RMSD in the tropical upper layer and at midlatitudes;this is determined by the actual noise-to-signal ratio of ocean temperature.(3)The satellite observations make a more significant contribution to the analysis toward independent observations in the extratropics;this is determined by both the geographical feature of the synthetic field RMSD(smaller at depth in the extratropics)and that of the covariance correlation scales(smaller in the extratropics).展开更多
The hot-section parts easily occur the creep-fatigued interaction under the condition of mechanicalthermal coupled load during the period of service, which may lead to the damage of the parts, and therefore, the measu...The hot-section parts easily occur the creep-fatigued interaction under the condition of mechanicalthermal coupled load during the period of service, which may lead to the damage of the parts, and therefore, the measurement and characterization of thermal-deformed fields of the parts are important to understand its damage process. Aiming at relevant demand, the bilateral telecentric-multispectral imaging system was established, the research of synchronous measurement technique of the temperature and deformation fields was developed. On the one hand, the measurement technology for surface temperature of the object was developed using the two-color images captured by the multispectral camera with bilateral telecentric lens and combined with colorimetric method. On the other hand, the 2 D-DIC measurement technique of the multispectral camera was developed by conducting digital image correlation analysis using the blue light images before and after deformation, which can measure the high temperature deformation field of the object(the blue light images were filtered by multispectral camera).Results showed that the bilateral telecentric lens is used to replace the ordinary optical lens for imaging,which can effectively eliminate the distortion of the multispectral imaging system. Since the temperature measurement process of this measurement system is little affected by the emissivity of the object, therefore, it has excellent robustness. The thermal expansion coefficients of the nickel alloys are evaluated at the temperature ranges of 700–1000℃, indicating this system can achieve the synchronous and precise measurement of the temperature and deformation fields of the object.展开更多
Atomic force microscopy(AFM)is increasingly being used as a fundamental tool for dimensional measurements at the nanoscale in the laboratory and in industry.Since the environmental temperature is not controlled in man...Atomic force microscopy(AFM)is increasingly being used as a fundamental tool for dimensional measurements at the nanoscale in the laboratory and in industry.Since the environmental temperature is not controlled in many measurements,or is even varied on purpose,quantification of its effects on AFM dimensional measurements is needed.In this paper,the influences of the temperature in the entire environment of the AFM(excluding only the controller and computer)and that in the local environment around the tip–sample are investigated.The results show that lateral dimensional measurements are affected mainly by the entire environmental temperature.However,vertical measurements are influenced by the temperature of both the entire environment and the local environment.The effects become significant for temperatures higher than some threshold,here between 35 and 40 XC.展开更多
The paper made a research on the fiber Bragg grating sensor demodulation system, which was based on virtual instrument labview and it developed a friendly upper monitor software. Based on the LM algorithm, the softwar...The paper made a research on the fiber Bragg grating sensor demodulation system, which was based on virtual instrument labview and it developed a friendly upper monitor software. Based on the LM algorithm, the software realized rapid and accurate spectral data fitting, improving dynamic characteristics and measuring precision of the system. Depending on different fiber Bragg grating sensors, it can realize flexible calibration. It has the functions of collection, display and data storage, which can flexibly design alarm threshold according to the practical application. The fiber Bragg grating sensors can be identified by the software so that the distributed network, with large capacity optical fiber sensing, can be achieved.展开更多
A new method for reconstructing the geological history of hydrocarbon accumulation is developed, which are constrained by U-Pb isotope age and clumped isotope((35)47) temperature of host minerals of hydrocarbon-bearin...A new method for reconstructing the geological history of hydrocarbon accumulation is developed, which are constrained by U-Pb isotope age and clumped isotope((35)47) temperature of host minerals of hydrocarbon-bearing inclusions. For constraining the time and depth of hydrocarbon accumulation by the laser in-situ U-Pb isotope age and clumped isotope temperature, there are two key steps:(1) Investigating feature, abundance and distribution patterns of liquid and gaseous hydrocarbon inclusions with optical microscopes.(2) Dating laser in-situ U-Pb isotope age and measuring clumped isotope temperature of the host minerals of hydrocarbon inclusions. These technologies have been applied for studying the stages of hydrocarbon accumulation in the Sinian Dengying gas reservoir in the paleo-uplift of the central Sichuan Basin. By dating the U-Pb isotope age and measuring the temperature of clumped isotope((35)47) of the host minerals of hydrocarbon inclusions in dolomite, three stages of hydrocarbon accumulation were identified:(1) Late Silurian: the first stage of oil accumulation at(416±23) Ma.(2) Late Permian to Early Triassic: the second stage of oil accumulation between(248±27) Ma and(246.3±1.5) Ma.(3) Yanshan to Himalayan period: gas accumulation between(115±69) Ma and(41±10) Ma. The reconstructed hydrocarbon accumulation history of the Dengying gas reservoir in the paleo-uplift of the central Sichuan Basin is highly consistent with the tectonic-burial history, basin thermal history and hydrocarbon generation history, indicating that the new method is a reliable way for reconstructing the hydrocarbon accumulation history.展开更多
Regularization methods were combined with line-of-sight tunable diode laser absorption spectroscopy(TDLAS)to measure nonuniform temperature distribution.Relying on measurements of 12 absorption transitions of water va...Regularization methods were combined with line-of-sight tunable diode laser absorption spectroscopy(TDLAS)to measure nonuniform temperature distribution.Relying on measurements of 12 absorption transitions of water vapor from 1300 nm to 1350 nm,the temperature probability distribution of nonuniform temperature distribution,for which a parabolic temperature profile is selected as an example in this paper,was retrieved by making the use of regularization methods.To examine the effectiveness of regularization methods,truncated singular value decomposition(TSVD),Tikhonov regularization and a revised Tikhonov regularization method were implemented to retrieve the temperature probability distribution.The results derived by using the three regularization methods were compared with that by using constrained linear least-square fitting.The results show that regularization methods not only generate closer temperature probability distributions to the original,but also are less sensitive to measurement noise.Particularly,the revised Tikhonov regularization method generate solutions in better agreement with the original ones than those obtained by using TSVD and Tikhonov regularization methods.The results obtained in this work can enrich the temperature distribution information,which is expected to play a more important role in combustion diagnosis.展开更多
This report describes a new method for measuring the temperature of the gas behind the reflected shock wave in shock tube, corresponding to the reservoir temperature of a shock tunnel, based on the chemical reaction o...This report describes a new method for measuring the temperature of the gas behind the reflected shock wave in shock tube, corresponding to the reservoir temperature of a shock tunnel, based on the chemical reaction of small amount of CF4 premixed in the test gas. The final product C2F4 is used as the temperature indicator, which is sampled and detected by a gas chromatography in the experiment. The detected concentration of C2F4 is correlated to the temperature of the reflected shock wave with the initial pressure P-1 and test time tau as parameters in the temperature range 3 300 K < T < 5 600 K, pressure range 5 kPa < P1 <12 kPa and tau similar or equal to 0.4 ms.展开更多
Temperature is one of the physical quantifies through which quantitative evaluation of the safety and reliability of industrial products can be achieved, and this has been used widely in practice. Under any environmen...Temperature is one of the physical quantifies through which quantitative evaluation of the safety and reliability of industrial products can be achieved, and this has been used widely in practice. Under any environmental condifion, regardless of the size of the object to be inspected, accurate and reliable measurement of temperature is of great practical importance. This review article presents a simple and direct method of temperature measurement, that can be applied to the local areas with difficulty in measuring the temperature by using normal thermometers. In the present article, two different application examples are demonstrated. One addresses the study of the electromigration of solders which are used as bonding metals in electronic devices (micro-structures). The application of the method to the shaft of a motor used in heavy industrial fields is explained as the second.展开更多
Electron thermal transport is one of the most complex processes in fusionplasmas. It is generally described by a simple thermal diffusivity in transport analyses ofdischarges, but there is evidence of critical gradien...Electron thermal transport is one of the most complex processes in fusionplasmas. It is generally described by a simple thermal diffusivity in transport analyses ofdischarges, but there is evidence of critical gradient effects with moderate stiffness. By analyzingperiodic perturbations to an equilibrium, one canmeasure the variations in electron energy flux andelectron temperature gradient over the perturbation cycle, obtaining the flux as a function ofgradient over the range of parameters generated by the perturbation. Although time-dependenttransport analysis is very sensitive to noise in the input data, averaging over many cycles of aperiodic perturbation can provide data of sufficient quality. The analyses presented here are basedon the ECE temperature data with high spatial and temporal resolution and full profile coverage onDIII-D for sawteeth and modulated ECH heating.展开更多
The embedded temperature sensing fabric was designed and woven according to the heat transmission model of the fabric.The temperature sensors were embedded into the multi-layered fabric that weft yarns were high-shrin...The embedded temperature sensing fabric was designed and woven according to the heat transmission model of the fabric.The temperature sensors were embedded into the multi-layered fabric that weft yarns were high-shrinkage polyester filaments.And the fabric was treated by a self-designed partial heat device,which can make the sensor be fixed in the fabric.The effects of yarn type,yarn linear density,fabric warp density,fabric structure,fabric layer numbers where the sensor is located,and the ambient temperature on the temperature measured value were investigated.The results demonstrated that when the higher thermal conductivity of yarns and lower density yarns were applied in the fabric as rawmaterials,they were favored to improve the measurement precision.Meanwhile,there were many factors that could make the measured values closer to the real value of the body,such as the plain fabric,the increased warp density of the fabric,the multiple-layer fabric where the sensor was located,the raised ambient testing temperature and the prolonged test time in the certain range.展开更多
基金supported by the Youth Science Foundation of Sichuan Province(Nos.2022NSFSC1230 and 2022NSFSC1231)the Science and Technology Innovation Seedling Project of Sichuan Province(No.MZGC20230080)+1 种基金the General project of the National Natural Science Foundation of China(No.12075039)the Key project of the National Natural Science Foundation of China(No.U19A2086)。
文摘A dedicated weak current measurement system was designed to measure the weak currents generated by the neutron ionization chamber.This system incorporates a second-order low-pass filter circuit and the Kalman filtering algorithm to effectively filter out noise and minimize interference in the measurement results.Testing conducted under normal temperature conditions has demonstrated the system's high precision performance.However,it was observed that temperature variations can affect the measurement performance.Data were collected across temperatures ranging from -20 to 70℃,and a temperature correction model was established through linear regression fitting to address this issue.The feasibility of the temperature correction model was confirmed at temperatures of -5 and 40℃,where relative errors remained below 0.1% after applying the temperature correction.The research indicates that the designed measurement system exhibits excellent temperature adaptability and high precision,making it particularly suitable for measuring weak currents.
基金supported by the National Natural Science Foundation of China (Grant No. 61703025)。
文摘We demonstrate an experimental method for the in situ temperature measurement of atomic vapor using the saturated absorption spectrum. By separately manipulating the frequency of the pump and probe beams, the position of the crossover peaks can move along the spectrum. Different velocity classes of atoms contribute to the crossover during the movement. We study the relationship between the intensity change of peaks and vapor temperature. Our experimental result around room temperature shows a deviation of less than 0.3 K. Compared with traditional thermometry using absorption spectroscopy, higher accuracy can theoretically be achieved with real-time thermometry.
文摘The function,features,and architecture of a robot that performs automatic temperature measurement and sampling applied on a 150-t AC electric arc furnace(EAF)production line of Baosteel were presented,and the key points of design and revamping experience on the site layout,device protection,lance tool,probe container,measuring position control,and system safety were summarized.Furthermore,a valuable reference for the application of automatic temperature measuring and sampling robots in EAF steelmaking plants will be provided.
基金supported by the National Natural Science Foundation of China (Grant No. 42061004)the Joint Special Project of Agricultural Basic Research of Yunnan Province (Grant No. 202101BD070001093)the Youth Special Project of Xingdian Talent Support Program of Yunnan Province
文摘Abrupt near-surface temperature changes in mountainous areas are a special component of the mountain climate system.Fast and accurate measurements of the locations,intensity,and width of the near-surface changes are necessary but highly difficult due to the complicated environmental conditions and instrumental issues.This paper develops a spatial pattern recognition method to measure the near-surface high temperature increase(NSHTI),one of the lesser-attended changes.First,raster window measurement was proposed to calculate the temperature lapse rate using MODIS land surface temperature and SRTM DEM data.It fully considers the terrain heights of two neighboring cells on opposite or adjacent slopes with a moving window of 3×3 cell size.Second,a threshold selection was performed to identify the NSHTI cells using a threshold of-0.65℃/100 m.Then,the NSHTI strips were parameterized through raster vectorization and spatial analysis.Taking Yunnan,a mountainous province in southwestern China,as the study area,the results indicate that the NSHTI cells concentrate in a strip-like pattern along the mountains and valleys,and the strips are almost parallel to the altitude contours with a slight northward uplift.Also,they are located mostly at a 3/5 height of high mountains or within 400 m from the valley floors,where the controlling topographic index is the altitude of the terrain trend surface but not the absolute elevation and the topographic uplift height and cutting depth.Additionally,the NSHTI intensity varies with the geographic locations and the proportions increase with an exponential trend,and the horizontal width has a mean of about 1000 m and a maximum of over 5000 m.The result demonstrates that the proposed method can effectively recognize NSHTI boundaries over mountains,providing support for the modeling of weather and climate systems and the development of mountain resources.
文摘Non-equilibrium radiation measurements behind strong shock wave for simulated Martian atmosphere are presented in this paper. The shock wave is established in a hydrogen oxygen combustion driven shock tube. Time- resolved spectra of the Av = 0 sequence of the B^2∑^+ → X^2∑^+ electronic transition of CN have been observed through optical emission spectroscopy (OES). A new method, which is based on fitting high resolution spectrum for rotational and vibrational temperatures measurement, is proposed to diag- nose temperature distribution behind the shock wave. It is estimated that the current scheme has the maximum deviation less than 8% (lσ) for vibrational temperature measurement through detailed analysis of the influence of the uncertainties of spectroscopic constants and spectral resolution. Radiation structure of the shock layer, including induction, relaxation and equilibrium process, and corresponding rotational and vibrational temperatures are obtained through time gating OES diagnostics with sub-microsecond temporal resolution. The present extensive results will strongly benefit the reaction rate estimation and computational fluid dynamics (CFD) code validation in high enthalpy Mars reentry chemistry.
基金The"863"Hi-Tech Research and Development Program of China under contract Nos2006AA10A412 and 2006AA10A416a projectfrom the National Natural Science Foundation of China under contract No.30671596+1 种基金a project from the Chinese Academy of Sciences under contract No.KSCX2-YW-N-47-07a project from the Ministry of Science and technology of China under contract No.2006GB24910469
文摘Laminaria japonica, Undaria pinnatifida, Ulva lactuca, Grateloupia turuturu and Palmaria palmata are suitable species that fit the requirements of a seaweed-animal integrated aquaculture system in terms of their viable biomass, rapid growth and promising nutrient uptake rates. In this investigation, the responses of the optimal chlorophyll fluorescence yield of the five algal species in tumble culture were assessed at a temperature range of 10 - 30℃. The results revealed that Ulva lactuca was the most resistant species to high temperature, withstanding 30℃ for 4 h without apparent decline in the optimal chlorophyll fluorescence yield . While the arctic alga Palmaria palmata was the most vulnerable one, showing significant decline in the optimal chlorophyll fluorescence yield at 25℃ for 2 h. The cold-water species Laminaria japonica, however, demonstrated strong ability to cope with higher temperature (24 -26℃ ) for shorter time (within 24 h) without significant decline in the optimal chlorophyll fluorescence yield . Grateloupia turuturu showed a general decrease in the optimal chlorophyll fluorescence yield with the rising temperature from 23 to 30℃ , similar to the temperate kelp Undaria pinnatifida. Changes of chlorophyll fluorescence yields of these algae were characterized differently indicating the existence of species-unique strategy to cope with high light. Measurements of the optimal chlorophyll fluorescence yield after short exposure to direct solar irradiance revealed how long these exposures could be without significant photoinhibition or with promising recovery in photosynthetic activities. Seasonal pattern of alternation of algal species in tank culture in the Northern Hemisphere at the latitude of 36°N was proposed according to these basic measurements.
基金supported by the National Nature Science Foundation of China (Grants 11132011 and 11472288)
文摘The plastic work-heat conversion coefficient is one key parameter for studying the work-heat conversion under dynamic deformation of materials. To explore this coefficient of 7075-T651 aluminum alloy under dynamic compression, dynamic compression experiments using the Hopkinson bar under four groups of strain rates were conducted, and the temperature signals were measured by constructing a transient infrared temperature measurement system. According to stress versus strain data as well as the corresponding temperature data obtained through the experiments, the influences of the strain and the strain rate on the coefficient of plastic work converted to heat were analyzed.The experimental results show that the coefficient of plastic work converted to heat of 7075-T651 aluminum alloy is not a constant at the range of 0.85–1 and is closely related to the strain and the strain rate. The change of internal structure of material under high strain rate reduces its energy storage capacity, and makes almost all plastic work convert into heat.
基金supported by the National Natural Science Foundation of China(10772188)
文摘A novel method based on wavelength-multiplexed line-of-sight absorption and profile fitting for nonuniform flow field measurement is reported. A wavelength scanning combing laser temperature and current modulation WMS scheme is used to implement the wavelength-multi- plexed-profile fitting method. Second harmonic (2f) signal of eight H20 transitions features near 7,170 cm^-1 are measured in one period using a single tunable diode laser. Spatial resolved temperature distribution upon a CH4/air premixed flat flame burner is obtained. The result validates the feasibility of strategy for non-uniform flow field diagnostics by means of WMS-2f TDLAS.
基金The National Natural Science Foundation of China under contract Nos 41706021 and 41976188。
文摘Assimilation systems absorb both satellite measurements and Argo observations.This assimilation is essential to diagnose and evaluate the contribution from each type of data to the reconstructed analysis,allowing for better configuration of assimilation parameters.To achieve this,two comparative reconstruction schemes were designed under the optimal interpolation framework.Using a static scheme,an in situ-only field of ocean temperature was derived by correcting climatology with only Argo profiles.Through a dynamic scheme,a synthetic field was first derived from only satellite sea surface height and sea surface temperature measurements through vertical projection,and then a combined field was reconstructed by correcting the synthetic field with in situ profiles.For both schemes,a diagnostic iterative method was performed to optimize the background and observation error covariance statics.The root mean square difference(RMSD)of the in situ-only field,synthetic field and combined field were analyzed toward assimilated observations and independent observations,respectively.The rationale behind the distribution of RMSD was discussed using the following diagnostics:(1)The synthetic field has a smaller RMSD within the global mixed layer and extratropical deep waters,as in the Northwest Pacific Ocean;this is controlled by the explained variance of the vertical surface-underwater regression that reflects the ocean upper mixing and interior baroclinicity.(2)The in situ-only field has a smaller RMSD in the tropical upper layer and at midlatitudes;this is determined by the actual noise-to-signal ratio of ocean temperature.(3)The satellite observations make a more significant contribution to the analysis toward independent observations in the extratropics;this is determined by both the geographical feature of the synthetic field RMSD(smaller at depth in the extratropics)and that of the covariance correlation scales(smaller in the extratropics).
基金the National Natural Science Foundation of China(Grant Nos.12032013 and 11972209)the National Key Research and Development Program of China(Grant No.2017YFB1103900)the National Science and Technology Major Project(Grant No.2017-VⅠ-0003-0073).
文摘The hot-section parts easily occur the creep-fatigued interaction under the condition of mechanicalthermal coupled load during the period of service, which may lead to the damage of the parts, and therefore, the measurement and characterization of thermal-deformed fields of the parts are important to understand its damage process. Aiming at relevant demand, the bilateral telecentric-multispectral imaging system was established, the research of synchronous measurement technique of the temperature and deformation fields was developed. On the one hand, the measurement technology for surface temperature of the object was developed using the two-color images captured by the multispectral camera with bilateral telecentric lens and combined with colorimetric method. On the other hand, the 2 D-DIC measurement technique of the multispectral camera was developed by conducting digital image correlation analysis using the blue light images before and after deformation, which can measure the high temperature deformation field of the object(the blue light images were filtered by multispectral camera).Results showed that the bilateral telecentric lens is used to replace the ordinary optical lens for imaging,which can effectively eliminate the distortion of the multispectral imaging system. Since the temperature measurement process of this measurement system is little affected by the emissivity of the object, therefore, it has excellent robustness. The thermal expansion coefficients of the nickel alloys are evaluated at the temperature ranges of 700–1000℃, indicating this system can achieve the synchronous and precise measurement of the temperature and deformation fields of the object.
基金the National Natural Science Foundation of China(No.51675504)the Fundamental Research Funds for the Central Universities(No.WK2090000022).
文摘Atomic force microscopy(AFM)is increasingly being used as a fundamental tool for dimensional measurements at the nanoscale in the laboratory and in industry.Since the environmental temperature is not controlled in many measurements,or is even varied on purpose,quantification of its effects on AFM dimensional measurements is needed.In this paper,the influences of the temperature in the entire environment of the AFM(excluding only the controller and computer)and that in the local environment around the tip–sample are investigated.The results show that lateral dimensional measurements are affected mainly by the entire environmental temperature.However,vertical measurements are influenced by the temperature of both the entire environment and the local environment.The effects become significant for temperatures higher than some threshold,here between 35 and 40 XC.
文摘The paper made a research on the fiber Bragg grating sensor demodulation system, which was based on virtual instrument labview and it developed a friendly upper monitor software. Based on the LM algorithm, the software realized rapid and accurate spectral data fitting, improving dynamic characteristics and measuring precision of the system. Depending on different fiber Bragg grating sensors, it can realize flexible calibration. It has the functions of collection, display and data storage, which can flexibly design alarm threshold according to the practical application. The fiber Bragg grating sensors can be identified by the software so that the distributed network, with large capacity optical fiber sensing, can be achieved.
基金Supported by the China National Science and Technology Major Project(2016ZX05004-002)Basic Research and Strategic Reserve Technology Research Fund of Institutes Directly Under CNPC(2018D-5008-03)PetroChina Science and Technology Project(2019D-5009-16)。
文摘A new method for reconstructing the geological history of hydrocarbon accumulation is developed, which are constrained by U-Pb isotope age and clumped isotope((35)47) temperature of host minerals of hydrocarbon-bearing inclusions. For constraining the time and depth of hydrocarbon accumulation by the laser in-situ U-Pb isotope age and clumped isotope temperature, there are two key steps:(1) Investigating feature, abundance and distribution patterns of liquid and gaseous hydrocarbon inclusions with optical microscopes.(2) Dating laser in-situ U-Pb isotope age and measuring clumped isotope temperature of the host minerals of hydrocarbon inclusions. These technologies have been applied for studying the stages of hydrocarbon accumulation in the Sinian Dengying gas reservoir in the paleo-uplift of the central Sichuan Basin. By dating the U-Pb isotope age and measuring the temperature of clumped isotope((35)47) of the host minerals of hydrocarbon inclusions in dolomite, three stages of hydrocarbon accumulation were identified:(1) Late Silurian: the first stage of oil accumulation at(416±23) Ma.(2) Late Permian to Early Triassic: the second stage of oil accumulation between(248±27) Ma and(246.3±1.5) Ma.(3) Yanshan to Himalayan period: gas accumulation between(115±69) Ma and(41±10) Ma. The reconstructed hydrocarbon accumulation history of the Dengying gas reservoir in the paleo-uplift of the central Sichuan Basin is highly consistent with the tectonic-burial history, basin thermal history and hydrocarbon generation history, indicating that the new method is a reliable way for reconstructing the hydrocarbon accumulation history.
基金support by the National Science Foundation for Distinguished Youth Scholars of China(Grant No.61225006)National Natural Science Foundation of China(Grant No.60972087)Natural Science Foundation of Beijing,China(Grant No.3112018).
文摘Regularization methods were combined with line-of-sight tunable diode laser absorption spectroscopy(TDLAS)to measure nonuniform temperature distribution.Relying on measurements of 12 absorption transitions of water vapor from 1300 nm to 1350 nm,the temperature probability distribution of nonuniform temperature distribution,for which a parabolic temperature profile is selected as an example in this paper,was retrieved by making the use of regularization methods.To examine the effectiveness of regularization methods,truncated singular value decomposition(TSVD),Tikhonov regularization and a revised Tikhonov regularization method were implemented to retrieve the temperature probability distribution.The results derived by using the three regularization methods were compared with that by using constrained linear least-square fitting.The results show that regularization methods not only generate closer temperature probability distributions to the original,but also are less sensitive to measurement noise.Particularly,the revised Tikhonov regularization method generate solutions in better agreement with the original ones than those obtained by using TSVD and Tikhonov regularization methods.The results obtained in this work can enrich the temperature distribution information,which is expected to play a more important role in combustion diagnosis.
基金The project supported by the China Aerodynamics Project for Basic Researches(J13.5.2 ZK04)
文摘This report describes a new method for measuring the temperature of the gas behind the reflected shock wave in shock tube, corresponding to the reservoir temperature of a shock tunnel, based on the chemical reaction of small amount of CF4 premixed in the test gas. The final product C2F4 is used as the temperature indicator, which is sampled and detected by a gas chromatography in the experiment. The detected concentration of C2F4 is correlated to the temperature of the reflected shock wave with the initial pressure P-1 and test time tau as parameters in the temperature range 3 300 K < T < 5 600 K, pressure range 5 kPa < P1 <12 kPa and tau similar or equal to 0.4 ms.
文摘Temperature is one of the physical quantifies through which quantitative evaluation of the safety and reliability of industrial products can be achieved, and this has been used widely in practice. Under any environmental condifion, regardless of the size of the object to be inspected, accurate and reliable measurement of temperature is of great practical importance. This review article presents a simple and direct method of temperature measurement, that can be applied to the local areas with difficulty in measuring the temperature by using normal thermometers. In the present article, two different application examples are demonstrated. One addresses the study of the electromigration of solders which are used as bonding metals in electronic devices (micro-structures). The application of the method to the shaft of a motor used in heavy industrial fields is explained as the second.
基金the US Department of Energy under grant DE-FG03-97-ER54415
文摘Electron thermal transport is one of the most complex processes in fusionplasmas. It is generally described by a simple thermal diffusivity in transport analyses ofdischarges, but there is evidence of critical gradient effects with moderate stiffness. By analyzingperiodic perturbations to an equilibrium, one canmeasure the variations in electron energy flux andelectron temperature gradient over the perturbation cycle, obtaining the flux as a function ofgradient over the range of parameters generated by the perturbation. Although time-dependenttransport analysis is very sensitive to noise in the input data, averaging over many cycles of aperiodic perturbation can provide data of sufficient quality. The analyses presented here are basedon the ECE temperature data with high spatial and temporal resolution and full profile coverage onDIII-D for sawteeth and modulated ECH heating.
基金Hubei Province Natural Science Fund Project,China(No.2013CFA090)
文摘The embedded temperature sensing fabric was designed and woven according to the heat transmission model of the fabric.The temperature sensors were embedded into the multi-layered fabric that weft yarns were high-shrinkage polyester filaments.And the fabric was treated by a self-designed partial heat device,which can make the sensor be fixed in the fabric.The effects of yarn type,yarn linear density,fabric warp density,fabric structure,fabric layer numbers where the sensor is located,and the ambient temperature on the temperature measured value were investigated.The results demonstrated that when the higher thermal conductivity of yarns and lower density yarns were applied in the fabric as rawmaterials,they were favored to improve the measurement precision.Meanwhile,there were many factors that could make the measured values closer to the real value of the body,such as the plain fabric,the increased warp density of the fabric,the multiple-layer fabric where the sensor was located,the raised ambient testing temperature and the prolonged test time in the certain range.