Correlation Study of Operational Data and System Performance of District Cooling System with Ice Storage
1
作者 Hui Cao Nan Li Jiajing Lin 《Journal of Power and Energy Engineering》 2024年第3期75-98,共24页
The district cooling system (DCS) with ice storage can reduce the peak electricity demand of the business district buildings it serves, improve system efficiency, and lower operational costs. This study utilizes a mon... The district cooling system (DCS) with ice storage can reduce the peak electricity demand of the business district buildings it serves, improve system efficiency, and lower operational costs. This study utilizes a monitoring and control platform for DCS with ice storage to analyze historical parameter values related to system operation and executed operations. We assess the distribution of cooling loads among various devices within the DCS, identify operational characteristics of the system through correlation analysis and principal component analysis (PCA), and subsequently determine key parameters affecting changes in cooling loads. Accurate forecasting of cooling loads is crucial for determining optimal control strategies. The research process can be summarized briefly as follows: data preprocessing, parameter analysis, parameter selection, and validation of load forecasting performance. The study reveals that while individual devices in the system perform well, there is considerable room for improving overall system efficiency. Six principal components have been identified as input parameters for the cold load forecasting model, with each of these components having eigenvalues greater than 1 and contributing to an accumulated variance of 87.26%, and during the dimensionality reduction process, we obtained a confidence ellipse with a 95% confidence interval. Regarding cooling load forecasting, the Relative Absolute Error (RAE) value of the light gradient boosting machine (lightGBM) algorithm is 3.62%, Relative Root Mean Square Error (RRMSE) is 42.75%, and R-squared value (R<sup>2</sup>) is 92.96%, indicating superior forecasting performance compared to other commonly used cooling load forecasting algorithms. This research provides valuable insights and auxiliary guidance for data analysis and optimizing operations in practical engineering applications. . 展开更多
关键词 DCS Correlation Coefficient PCA Hourly cooling Load system Performance
下载PDF
The Selection of Cooling Systems of Giant Hydro-Generators
2
作者 Li Dingzhong China Hydropower Engineering Consulting Group 《Electricity》 2010年第2期45-49,共5页
The selection of cooling system for hydro-generator in Ertan Hydropower Station is reviewed in this paper. The new viewpoint on air-cooled system of hydraulic generator of recent years is analyzed and described. That ... The selection of cooling system for hydro-generator in Ertan Hydropower Station is reviewed in this paper. The new viewpoint on air-cooled system of hydraulic generator of recent years is analyzed and described. That is, "Full air-cooled system is always preferred to 展开更多
关键词 HIGH The Selection of cooling systems of Giant Hydro-Generators
下载PDF
Influence of Cooling Systems on the Behaviour of Dairy Cows Housed in Cubicle Barn
3
作者 Matteo Barbari Lorenzo Leso Giuseppe Rossi Alberto Scaramelli Stefano Simonini 《Journal of Agricultural Science and Technology(A)》 2012年第1期40-49,共10页
关键词 冷却系统 奶牛 行为 谷仓 空调冷却水系统 冷却效果 冷气流 试验
下载PDF
Implementation of Cooling Systems to Enhance Dairy Cows' Microenvironment
4
作者 M. Samer 《Journal of Environmental Science and Engineering》 2011年第12期1654-1661,共8页
关键词 冷却系统 微环境 计算机系统 数学模型 开发工具 奶牛 冷却风扇 设计师
下载PDF
Implementing a DIKW model on a deep mine cooling system 被引量:14
5
作者 Jan Gabriel Pretorius Marc John Mathews +2 位作者 Philip Maré Marius Kleingeld Johann van Rensburg 《International Journal of Mining Science and Technology》 SCIE EI CSCD 2019年第2期319-326,共8页
The South African mining industry has been experiencing increasing economic pressure. Deep mines also suffer from very hot workplaces, which leads to safety risks. These factors place stress on managers to reach their... The South African mining industry has been experiencing increasing economic pressure. Deep mines also suffer from very hot workplaces, which leads to safety risks. These factors place stress on managers to reach their production targets while providing safe workplace conditions. The data information knowledge wisdom(DIKW) model, also known as the wisdom hierarchy, was implemented on a deep mine cooling system. This study aims to show that a simple model such as the DIKW model can assist managers in improving their deep mine cooling system's performance. The study found that the DIKW approach is a suitable approach for use on mine cooling systems to facilitate operational improvements.Applying the DIKW approach to a case study on a mine cooling system created substantial awareness and facilitated a cooling duty improvement of 55% which relates to an increase of 5.3 MW of refrigeration. The results of this study indicate that the DIKW approach may be a suitable approach to optimise management on deep mines using their existing infrastructure. 展开更多
关键词 DIKW cooling system MINING REPORTING
下载PDF
Research and application of methods for effectiveness evaluation of mine cooling system 被引量:7
6
作者 Guo Pingye Wang Yanwei +2 位作者 Duan Mengmeng Pang Dongyang Li Nan 《International Journal of Mining Science and Technology》 SCIE EI CSCD 2015年第4期649-654,共6页
Regarding the complexity and inconsistency of results in existing evaluation methods of mine cooling system, this paper clarifies the advantages, disadvantages and application of various mine cooling systems through p... Regarding the complexity and inconsistency of results in existing evaluation methods of mine cooling system, this paper clarifies the advantages, disadvantages and application of various mine cooling systems through principle analysis, and divides all the cooling systems into air-cooling, ice-cooling and water-cooling according to the transportation of cold energy. On this basis, the paper proposes a simple and efficient evaluation method for mine cooling system. The first index of this method is the air temperature at point C which is 15 m away from the return wind corner at working face. A cooling system will be judged ineligible if the air temperature at point C is above 30 °C during operation, because in this case, the combustible gases in coal will sharply overflow, inducing gas incidents. Based on the preliminary judgment of the first index, another two evaluation indexes are proposed based on the cooling ability and dehumidification of an airflow volume of 1000 m3/min at point C to evaluate the investment and operation cost of mine cooling system. This evaluation method has already been successfully applied in the cooling system design of Zhangshuanglou coal mine. 展开更多
关键词 降温系统 效能评估方法 矿井 应用 评价方法 冷却系统 空气温度 空气冷却
下载PDF
A LN2-based cooling system for a next-generation liquid xenon dark matter detector 被引量:3
7
作者 Karl Ludwig Giboni Pratibha Juyal +2 位作者 Elena Aprile Yun Zhang Junji Naganoma 《Nuclear Science and Techniques》 SCIE CAS CSCD 2020年第8期24-34,共11页
In recent years, cooling technology for liquid xenon(LXe) detectors has advanced driven by the development of dark matter(DM) detectors with target mass in the 100–1000 kg range. The next generation of DM detectors b... In recent years, cooling technology for liquid xenon(LXe) detectors has advanced driven by the development of dark matter(DM) detectors with target mass in the 100–1000 kg range. The next generation of DM detectors based on LXe will be in the 50,000 kg(50 t)range requiring more than 1 k W of cooling power. Most of the prior cooling methods become impractical at this level.For cooling a 50 t scale LXe detector, a method is proposed in which liquid nitrogen(LN2) in a small local reservoir cools the xenon gas via a cold finger. The cold finger incorporates a heating unit to provide temperature regulation. The proposed cooling method is simple, reliable, and suitable for the required long-term operation for a rare event search. The device can be easily integrated into present cooling systems, for example the ‘‘Cooling Bus’ ’employed for the Panda X I and II experiments. It is still possible to cool indirectly with no part of the cooling or temperature control system getting in direct contact with the clean xenon in the detector. Also, the cooling device can be mounted at a large distance, i.e., the detector is cooled remotely from a distance of 5–10 m. The method was tested in a laboratory setup at Columbia University to carry out different measurements with a small LXe detector and behaved exactly as predicted. 展开更多
关键词 Noble liquid detectors(scintillation ionization double-phase) Dark matter detectors(WIMPs axions etc.) Large detector systems for particle and astroparticle physics Very low-energy charged particle detectors Time projection chambers Cryogenics Detector cooling and thermo-stabilization
下载PDF
Opti mization and Model of Laminar Cooling Control Systemfor Hot Strip Mills 被引量:22
8
作者 XIE Hai-bo LIU Xiang-hua +1 位作者 WANG Guo-dong ZHANG Zhong-ping 《Journal of Iron and Steel Research(International)》 SCIE EI CAS CSCD 2006年第1期18-22,共5页
The structure of laminar cooling control system for hot rolling was introduced and the control mode, cooling strategy, segment tracking and model recalculation were analyzed. The parameters of air/water cooling models... The structure of laminar cooling control system for hot rolling was introduced and the control mode, cooling strategy, segment tracking and model recalculation were analyzed. The parameters of air/water cooling models were optimized by regressing the data gathering in situ, and satisfactory effect was obtained. The coiling temperature can be controlled within ±15℃. 展开更多
关键词 hot rolled strip laminar cooling control system model parameter optimization
下载PDF
Thermal-environment characteristics and comfort of combined radiant-floor (Korean heating system ondol) and convective cooling system 被引量:3
9
作者 LEE Kang-Guk HONG Won-Hwa 《Journal of Central South University》 SCIE EI CAS 2013年第12期3589-3603,共15页
The thermal-environment characteristics of the existing forced-convection cooling system were compared with those of the convective cooling system, which combined the radiant-floor cooling system using floor-heating p... The thermal-environment characteristics of the existing forced-convection cooling system were compared with those of the convective cooling system, which combined the radiant-floor cooling system using floor-heating panel typically applied to apartments in South Korea with the forced-convection cooling system using improved fan coil unit. The subjective warm/cool-feeling responses to the combined radiant-floor and convective cooling system in the questionnaire survey conducted among the test subjects were analyzed to establish the basic data for the combined cooling system. The results show that in the thermal-equilibrium condition, the vertical air temperature difference in the model living room is larger in the forced-convection-cooling condition. Most of the subjects feel a proper warm/cool feeling on their entire body, but they feel colder on the foot and lower body in the combined-cooling condition. 展开更多
关键词 冷却系统 强制对流 辐射地板 环境特征 采暖系统 韩国 舒适性 平衡状态
下载PDF
Optimal air-supply mode of hybrid system with radiant cooling and dedicated outdoor air 被引量:5
10
作者 丁研 田喆 朱能 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第2期735-746,共12页
The hybrid system with radiant cooling and dedicated outdoor air not only possesses high energy efficiency, but also creates a healthy and comfortable indoor environment. Indoor air quality will be improved by the ded... The hybrid system with radiant cooling and dedicated outdoor air not only possesses high energy efficiency, but also creates a healthy and comfortable indoor environment. Indoor air quality will be improved by the dedicated outdoor air system(DOAS) and indoor thermal comfort can be enhanced by the radiant cooling system(RCS). The optimal air-supply mode of the hybrid system and the corresponding design approach were investigated. A full-scale experimental chamber with various air outlets and the ceiling radiant cooling panels(CRCP) was designed and established. The performances of different air-supply modes along with CRCPs were analyzed by multi-index evaluations. Preliminary investigations were also conducted on the humidity stratification and the control effect of different airflow modes to prevent condensation on CRCP. The overhead supply air is recommended as the best combination mode for the hybrid system after comprehensive comparison of the experiment results. The optimal proportion of CRCP accounting for the total cooling capacities in accord with specific cooling loads is found, which may provide valuable reference for the design and operation of the hybrid system. 展开更多
关键词 混合动力系统 室外空气 辐射冷却 送风 连续配筋混凝土路面 室内空气质量 设计方法 室内环境
下载PDF
Study on Effects of Diesel Engine Cooling System Parameters on Water Temperature 被引量:3
11
作者 骆清国 冯建涛 +1 位作者 刘国夫 桂勇 《Defence Technology(防务技术)》 SCIE EI CAS 2011年第3期129-134,共6页
A simulation model for a certain diesel engine cooling system is set up by using GT-COOL. The backwater temperature response in different operating conditions is simulated numerically. The effects of single or multipl... A simulation model for a certain diesel engine cooling system is set up by using GT-COOL. The backwater temperature response in different operating conditions is simulated numerically. The effects of single or multiple system parameters on the water temperature are analyzed. The results show that, changing different single parameters, the time taken for the steady backwater temperature is different, but relatively short;and if multiple parameters are changed, the time will be longer. Referred to the thermal balance test, the simulation results are validated and provide a basis for the intelligent control of the cooling system. 展开更多
关键词 power machinery engineering diesel engine cooling system transient response SIMULATION
下载PDF
Field experimental study on the cooling effect of mine cooling system acquiring cold source from return air 被引量:8
12
作者 Guo Pingye Chen Chen 《International Journal of Mining Science and Technology》 SCIE EI 2013年第3期453-456,共4页
With the increase of mining depth, more and deeper coal mines are limited by heat disaster. The cooling energy in deep mine cooling system comes from mine water inrush or ground cooling tower, but we cannot adopt the ... With the increase of mining depth, more and deeper coal mines are limited by heat disaster. The cooling energy in deep mine cooling system comes from mine water inrush or ground cooling tower, but we cannot adopt the two methods because mine water inrush in many old coal mines in China is limited. What is more, the cooling pipelines cannot be put in narrow pit-shaft. To settle the problem above, according to the characteristics of Zhangxiaolou Coal Mine, this paper adopts the deep mine return air as the cooling energy for deep mine cooling system. In addition, we carried out cite test to extract cold energy from return air. Through monitoring the water quantity, water temperature of cooling system and air temperature, we got the thermodynamic equilibrium parameters during the cooling energy acquisition analysis and the effect of cooling system that the temperature and humidity on working face are respectively reduced to 8-12 ℃ and 8-15% through cooling. This research offers experimental reference for deep mine cooling which lacks cooling energy. 展开更多
关键词 Heat disaster Cold source Return air cooling system
下载PDF
Simulation and experimental study on hydraulic driving fan cooling system for construction machinery working on plateau 被引量:1
13
作者 李毅 《Journal of Chongqing University》 CAS 2009年第3期201-208,共8页
Overheating of the engine, the transmission and the hydraulic device is a problem when the construction machinery works on plateau. To solve this problem, we proposed an electro-controlled hydraulic driving fan coolin... Overheating of the engine, the transmission and the hydraulic device is a problem when the construction machinery works on plateau. To solve this problem, we proposed an electro-controlled hydraulic driving fan cooling system (ECHDFCS). The system was applied to a 50-wheel loader. We carried out the coolant temperature simulation using fluid modeling software FLOWMASTER, followed by laboratory experiments and road tests. The results show that ECHDFCS can adjust the cooling capability of the system automatically based on machine heat dissipation requirements. The coolant temperature is consequently remained within an appropriate range. The simulation results are consistent with the experiment results when the experiment is performed on the plain, but are different from the road tests in some investigated parameters on the plateau. 展开更多
关键词 实验室试验 液压驱动装置 机械系统 冷却系统 高原 风扇 冷却液温度 建筑
下载PDF
1D/3D Coupling Calculation Analysis on Bus Cooling System 被引量:2
14
作者 Kai Shen Feihong Li Jimin Ni 《Energy and Power Engineering》 2014年第14期550-556,共7页
Compared with front engine vehicle, the windward side’s flow field in cooling model of rear engine bus is complicated and it can’t be calculated by means of 1D model. For this problem, this paper has used Star-CCM t... Compared with front engine vehicle, the windward side’s flow field in cooling model of rear engine bus is complicated and it can’t be calculated by means of 1D model. For this problem, this paper has used Star-CCM to build a 3D simulation model of cooling system, engine compartment and complete vehicle. Then, it had a 1D/3D coupling calculation on cooling system with Kuli software. It could be helpful in the optimization design of the flow field of rear engine compartment and optimization match of cooling system. 展开更多
关键词 1D/3D COUPLING Calculation BUS cooling system REAR ENGINE COMPARTMENT
下载PDF
A reversibly used cooling tower with adaptive neuro-fuzzy inference system 被引量:2
15
作者 吴加胜 张国强 +3 位作者 张泉 周晋 郭永辉 沈炜 《Journal of Central South University》 SCIE EI CAS 2012年第3期715-720,共6页
An adaptive neuro-fuzzy inference system(ANFIS) for predicting the performance of a reversibly used cooling tower(RUCT) under cross flow conditions as part of a heat pump system for a heating mode in winter was demons... An adaptive neuro-fuzzy inference system(ANFIS) for predicting the performance of a reversibly used cooling tower(RUCT) under cross flow conditions as part of a heat pump system for a heating mode in winter was demonstrated.Extensive field experimental work was carried out in order to gather enough data for training and prediction.The statistical methods,such as the correlation coefficient,absolute fraction of variance and root mean square error,were given to compare the predicted and actual values for model validation.The simulation results predicted with the ANFIS can be used to simulate the performance of a reversibly used cooling tower quite accurately.Therefore,the ANFIS approach can reliably be used for forecasting the performance of RUCT. 展开更多
关键词 自适应神经模糊推理系统 冷却塔 可逆 ANFIS 预测值 热泵系统 实验工作 统计方法
下载PDF
Fuzzy logic controller design with unevenly-distributed membership function for high performance chamber cooling system 被引量:2
16
作者 曹健鹏 Seok-Kwon Jeong Young-Mi Jung 《Journal of Central South University》 SCIE EI CAS 2014年第7期2684-2692,共9页
Fuzzy logic controller adopting unevenly-distributed membership function was presented with the purpose of enhancing performance of the temperature control precision and robustness for the chamber cooling system.Histo... Fuzzy logic controller adopting unevenly-distributed membership function was presented with the purpose of enhancing performance of the temperature control precision and robustness for the chamber cooling system.Histogram equalization and noise detection were performed to modify the evenly-distributed membership functions of error and error change rate into unevenly-distributed membership functions.Then,the experimental results with evenly and unevenly distributed membership functions were compared under the same outside environment conditions.The experimental results show that the steady-state error is reduced around 40% and the noise disturbance is rejected successfully even though noise range is 60% of the control precision range.The control precision is improved by reducing the steady-state error and the robustness is enhanced by rejecting noise disturbance through the fuzzy logic controller with unevenly-distributed membership function.Moreover,the system energy efficiency and lifetime of electronic expansion valve(EEV) installed in chamber cooling system are improved by adopting the unevenly-distributed membership function. 展开更多
关键词 模糊逻辑控制器 不均匀分布 冷却系统 隶属度函数 性能 隶属函数 误差变化率 设计
下载PDF
Present status and one upgrading method with a cold compressor of the EAST sub-cooling helium cryogenic system 被引量:3
17
作者 朱志刚 张启勇 +4 位作者 宋云涛 庄明 周芷伟 成安义 朱平 《Plasma Science and Technology》 SCIE EI CAS CSCD 2017年第5期102-108,共7页
Since 2006, the superconducting toroidal field(TF) coils of the Experimental Advanced Superconducting Tokomak(EAST) have been successfully cooled by supercritical helium at a temperature of 4.5 K and a pressure of... Since 2006, the superconducting toroidal field(TF) coils of the Experimental Advanced Superconducting Tokomak(EAST) have been successfully cooled by supercritical helium at a temperature of 4.5 K and a pressure of 4 bara in eleven experiments. To obtain higher operating currents and magnetic fields it is necessary to lower the operating temperature of the TF coils.The EAST sub-cooling helium cryogenic system, with a warm oil ring pump(ORP), was tested twice in cool-down experiments, which made the TF coils operate at 3.8 K. However, the long term operational stability of the sub-cooling system cannot be guaranteed because of the ORP's poor mechanical and control performance. In this paper, the present status of the EAST subcooling helium cryogenic system is described, and then several cooling methods below 4.2 K and their merits are presented and analyzed. Finally, an upgrading method with a cold compressor for an EAST sub-cooling helium cryogenic system is proposed. The new process flow and thermodynamic calculation of the sub-cooling helium system, and the main parameters of the cold compressor, are also presented in detail. This work will provide a reference for the future upgrading of the sub-cooling helium system for higher operation parameters of the EAST device. 展开更多
关键词 EAST cryogenic system helium refrigerator sub-cooling helium cold compressor
下载PDF
MIC in Circulating Cooling Water System 被引量:1
18
作者 Ping Xu Zhaoyi Xu +2 位作者 Jin Wang Yajun Zhang Li Zhang 《Journal of Water Resource and Protection》 2012年第4期203-206,共4页
MIC is one of the main problems of circulating cooling water system. The direct economic loss by MIC is about 300 to 500 billion dollars. It is good to understand MIC in order to control MIC. Source and species of mic... MIC is one of the main problems of circulating cooling water system. The direct economic loss by MIC is about 300 to 500 billion dollars. It is good to understand MIC in order to control MIC. Source and species of microorganisms was introduced firstly. There are three kinds of microorganisms in the system, including bacteria, fungi and algae. Species of these microorganisms are shown in the paper. Then, mechanisms of MIC are analysed. Although there is no universal mechanism of MIC, MIC is still mainly an electrochemical corrosion in nature. Meanwhile, the mechanisms on SRB and iron bacteria are introduced in details. At last, several methods of microorganisms control are put forward in the paper. 展开更多
关键词 CIRCULATING cooling Water system MIC MICROORGANISMS SPECIES MECHANISM Of MIC Control Methods
下载PDF
Double-passage mechanical cooling in a coupled optomechanical system
19
作者 穆青霞 郎潮 张闻钊 《Chinese Physics B》 SCIE EI CAS CSCD 2019年第11期173-178,共6页
We consider a three-mode optomechanical system where two cavity modes are coupled to a common mechanical oscillator. We focus on the resolved sideband limit and illustrate the relation between the significant paramete... We consider a three-mode optomechanical system where two cavity modes are coupled to a common mechanical oscillator. We focus on the resolved sideband limit and illustrate the relation between the significant parameters of the system and the instantaneous-state mean phonon number of the oscillator cooled to the ground state, particularly at the early stage of the evolution. It is worth noting that the optical coupling sets up a correlation between the two cavity modes,which has significant effect on the cooling process. Using numerical solutions, we find that the inter-cavity coupling will decrease the cooling effect when both cavities have the same effective optomechanical coupling. However, when the effective optomechanical couplings are different, the cooling effect will be strongly improved by selecting appropriate range of inter-cavity coupling. 展开更多
关键词 optomechanical system GROUND-STATE cooling QUANTUM OPTICS
下载PDF
Thermal-Fluid Coupling Simulation of Ventilation Cooling System of Generator Based on FLOWMASTER
20
作者 Wang Yuting Li Yanjun +1 位作者 Cao Yuyuan Zhang Tao 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI CSCD 2018年第3期516-521,共6页
By taking a 2.3 MW double-fed asynchronous generator as an example,a new method for fast simulation analysis of ventilation cooling system inside generator is proposed based on the one-dimensional simulation software ... By taking a 2.3 MW double-fed asynchronous generator as an example,a new method for fast simulation analysis of ventilation cooling system inside generator is proposed based on the one-dimensional simulation software FLOWMASTER.The thermal-fluid coupling simulation model of ventilation cooling system inside generator is established.Under the stable running state of the generator,the flow velocity distribution and temperature rise of the key parts of the generator are analyzed.The results prove that the ventilation structure design of the generator meets the temperature rise limit.The simulation results are compared with the theoretical calculation results and the experimental results,which verify the correctness of the thermal-fluid coupling simulation method proposed in this paper. 展开更多
关键词 通风冷却 生成器 热液体 联合模拟 系统 模拟软件 模拟模型 模拟分析
下载PDF
上一页 1 2 250 下一页 到第