To realize the efficient transient simulation of a grid-connected power generation system based on multiple inverters, this paper proposes a hybrid simulation method integrating the models of electromagnetic transient...To realize the efficient transient simulation of a grid-connected power generation system based on multiple inverters, this paper proposes a hybrid simulation method integrating the models of electromagnetic transient and dynamic phasors. Based on a demonstration of the concepts and properties of dynamic phasors, the models of single-phase and three-phase inverters described by dynamic phasors are established first. Considering the numerical compatibility problem between dynamic phasors and instantaneous values, an interface scheme between dynamic phasors and instantaneous values is designed, and the efficiency and precision differences of various transformation methods are compared in detail.Finally, by utilizing MATLAB/Simulink, a hybrid simulation platform of a multi-inverter grid-connected system is built, and the efficiency and accuracy of the hybrid simulation are validated via comparison with the full electromagnetic transient simulation.展开更多
Due to the increased penetration of multi-inverter distributed generation(DG)systems,different DG technologies,inverter control methods,and other inverter functions are challenging the capabilities of islanding detect...Due to the increased penetration of multi-inverter distributed generation(DG)systems,different DG technologies,inverter control methods,and other inverter functions are challenging the capabilities of islanding detection.In addition,multi-inverter networks connecting the distribution system point of common coupling(PCC)create islanding at paralleling inverters,which adds the vulnerability of islanding detection.Furthermore,available islanding detection must overcome more challenges from non-detection zones(NDZs)under reduced power mismatches.Therefore,in this study,a new method called parameter self-adapting active islanding detection was utilized to minimize the dilution effect and reduce NDZs in multi-inverter power systems.The method utilizes an active frequency drift(AFD)method and applies a positive feedback gain of adoption parameters,which significantly minimizes NDZs at parallel inverters.The simulation and experimental outcomes indicate that the proposed method can effectively weaken the dilution effect in multi-inverter networks connecting the distribution system PCC.展开更多
Islanding detection is an essential function for safety and reliability in grid-connected Distributed Generation Systems (DGS). Passive and active islanding detection methods have been analyzed in literature consideri...Islanding detection is an essential function for safety and reliability in grid-connected Distributed Generation Systems (DGS). Passive and active islanding detection methods have been analyzed in literature considering DGS with only one inverter connected to the utility. With the big scale application of photovoltaic (PV) power systems, islanding detection technology of multi-inverter DGS has been paid more attention. This paper analyzes the performance of diverse islanding detection methods in multiple inverters grid-connected PV systems. Non-Detection Zones (NDZ) of multi-inverter systems in a load parameter space are used as analytical tool. The paper provides guidance for the islanding detection design in multiple grid-connected inverters.展开更多
For a multi-inverter grid-connected system,the stability of the point of common coupling(PCC)voltage is evaluated considering the distribution parameters of the transmission lines.First,the systems on both sides of th...For a multi-inverter grid-connected system,the stability of the point of common coupling(PCC)voltage is evaluated considering the distribution parameters of the transmission lines.First,the systems on both sides of the PCC are equalized,a smallsignal equivalent circuit similar to the“current source-grid”is established,and a mathematical model for the voltage of the PCC is derived.Then,using Euler’s formula and Nyquist stability criterion,the PCC voltage stability of the grid-connected system is evaluated by the impedance analysis method under the premise that the single-side excitation is stable.In addition,the gridconnected conditions causing PCC voltage instability are studied.A phase compensation method based on an impedance phase compensation control strategy is introduced.The stability of the grid-connected system is improved by compensating the phase margin at the equivalent impedance crossover-section frequency on both sides of the grid-connected system PCC.Finally,a simulation circuit is built to simulate and analyze the proposed model and phase compensation method.The simulation results verify the accuracy and effectiveness of the theoretical analysis.展开更多
基金supported by the State Grid Science and Technology Project (grant no. KJ2021-069)。
文摘To realize the efficient transient simulation of a grid-connected power generation system based on multiple inverters, this paper proposes a hybrid simulation method integrating the models of electromagnetic transient and dynamic phasors. Based on a demonstration of the concepts and properties of dynamic phasors, the models of single-phase and three-phase inverters described by dynamic phasors are established first. Considering the numerical compatibility problem between dynamic phasors and instantaneous values, an interface scheme between dynamic phasors and instantaneous values is designed, and the efficiency and precision differences of various transformation methods are compared in detail.Finally, by utilizing MATLAB/Simulink, a hybrid simulation platform of a multi-inverter grid-connected system is built, and the efficiency and accuracy of the hybrid simulation are validated via comparison with the full electromagnetic transient simulation.
基金supported by the National Natural Science Foundation of China under Grant No.61671109.
文摘Due to the increased penetration of multi-inverter distributed generation(DG)systems,different DG technologies,inverter control methods,and other inverter functions are challenging the capabilities of islanding detection.In addition,multi-inverter networks connecting the distribution system point of common coupling(PCC)create islanding at paralleling inverters,which adds the vulnerability of islanding detection.Furthermore,available islanding detection must overcome more challenges from non-detection zones(NDZs)under reduced power mismatches.Therefore,in this study,a new method called parameter self-adapting active islanding detection was utilized to minimize the dilution effect and reduce NDZs in multi-inverter power systems.The method utilizes an active frequency drift(AFD)method and applies a positive feedback gain of adoption parameters,which significantly minimizes NDZs at parallel inverters.The simulation and experimental outcomes indicate that the proposed method can effectively weaken the dilution effect in multi-inverter networks connecting the distribution system PCC.
文摘Islanding detection is an essential function for safety and reliability in grid-connected Distributed Generation Systems (DGS). Passive and active islanding detection methods have been analyzed in literature considering DGS with only one inverter connected to the utility. With the big scale application of photovoltaic (PV) power systems, islanding detection technology of multi-inverter DGS has been paid more attention. This paper analyzes the performance of diverse islanding detection methods in multiple inverters grid-connected PV systems. Non-Detection Zones (NDZ) of multi-inverter systems in a load parameter space are used as analytical tool. The paper provides guidance for the islanding detection design in multiple grid-connected inverters.
文摘For a multi-inverter grid-connected system,the stability of the point of common coupling(PCC)voltage is evaluated considering the distribution parameters of the transmission lines.First,the systems on both sides of the PCC are equalized,a smallsignal equivalent circuit similar to the“current source-grid”is established,and a mathematical model for the voltage of the PCC is derived.Then,using Euler’s formula and Nyquist stability criterion,the PCC voltage stability of the grid-connected system is evaluated by the impedance analysis method under the premise that the single-side excitation is stable.In addition,the gridconnected conditions causing PCC voltage instability are studied.A phase compensation method based on an impedance phase compensation control strategy is introduced.The stability of the grid-connected system is improved by compensating the phase margin at the equivalent impedance crossover-section frequency on both sides of the grid-connected system PCC.Finally,a simulation circuit is built to simulate and analyze the proposed model and phase compensation method.The simulation results verify the accuracy and effectiveness of the theoretical analysis.