This paper presents a cascode configuration synchronous rectifier device based on silicon MOSFET and Schottky diode,which can replace traditional power diode directly.This structure has self-driven ability with simple...This paper presents a cascode configuration synchronous rectifier device based on silicon MOSFET and Schottky diode,which can replace traditional power diode directly.This structure has self-driven ability with simple external circuit,and the conduction characteristic is preferable to a power diode.Static characterization and switching behavior analysis of proposed structure are conducted in this paper.The switching process is illustrated in detail using real model which considers the parasitic inductances and the nonlinearity of junction capacitors.The real time internal voltage and current value during switching transition are deduced with the equivalent circuit.To validate the analysis,two voltage specification rectifiers are built.Finally,double-pulse test results and the practical design example verify the performance advantages of proposed structure.展开更多
By using the output inductors and body capacitances without adding any component compared with hard switching synchronous rectifier,the topology of a soft switched synchronous rectifier with phase-shifted full bridge ...By using the output inductors and body capacitances without adding any component compared with hard switching synchronous rectifier,the topology of a soft switched synchronous rectifier with phase-shifted full bridge zero voltage switching DC/DC converter is proposed. The converter efficiency is maximized due to soft switching of the full bridge MOSFETs and the synchronous MOSFETs, and also the low conduction loss of synchronous MOSFET. The operation principles of the circuit are analyzed in detail and the small-signal model is derived, also the converter dynamic characteristics are analyzed. Frequency responses of transfer functions under different values of transformer primary leakage inductance are discussed. The experimental results were obtained from a 400 V input and 100 A/12 V output DC/DC converter operating at 100 kHz. The results show that the converter efficiency is 2% higher in rated power than traditional diode rectifier.展开更多
DC distribution networks are often employed in isolated power systems like in marine and aeronautical applications. An interesting alternative to DC machines for the supply of DC grids is constituted by a three-phase ...DC distribution networks are often employed in isolated power systems like in marine and aeronautical applications. An interesting alternative to DC machines for the supply of DC grids is constituted by a three-phase alternator feeding an AC/DC rectifier. In this paper, alternative solutions are investigated where the AC alternator is equipped with more (iV) three-phase windings and feeds the DC load through more (N) cascade-connected rectifiers. The advantages of this solution with respect to the conventional three-phase topology are highlighted along with their dependence on the number (N) of the alternator windings. For this purpose, test results are reported and discussed on a prototype generator whose stator coils can be differently connected to obtained one, two, three or four windings. The major benefits (in terms of DC output current quality and field current ripple) are found when passing from the three-phase solution to the dual winding topology; conversely, relatively little advantage is gained by increasing the number of stator windings above two.展开更多
The information of the field current is essential for the brushless synchronous starter/generator system,which determines the performance and health status of this system.However,since the field winding of the main ma...The information of the field current is essential for the brushless synchronous starter/generator system,which determines the performance and health status of this system.However,since the field winding of the main machine is installed in the rotor part,the measurement of the field current in this brushless system seem impossible.Considering that,the field current might be affected by the rectifier mode,the field current estimation method in different rectifier mode is studied in this paper.The main exciter(ME)rotor currents were restructured based on the ME flux equations.With these restructured rotor currents,the field current in different rectifier commutation mode is analyzed,then the field current estimation method considering the rectifier mode can be obtained.The experiments in different rectifier modes are carried out to verify the proposed method.展开更多
基金supported in part by the National Natural Science Foundation of China (No.51777093)
文摘This paper presents a cascode configuration synchronous rectifier device based on silicon MOSFET and Schottky diode,which can replace traditional power diode directly.This structure has self-driven ability with simple external circuit,and the conduction characteristic is preferable to a power diode.Static characterization and switching behavior analysis of proposed structure are conducted in this paper.The switching process is illustrated in detail using real model which considers the parasitic inductances and the nonlinearity of junction capacitors.The real time internal voltage and current value during switching transition are deduced with the equivalent circuit.To validate the analysis,two voltage specification rectifiers are built.Finally,double-pulse test results and the practical design example verify the performance advantages of proposed structure.
文摘By using the output inductors and body capacitances without adding any component compared with hard switching synchronous rectifier,the topology of a soft switched synchronous rectifier with phase-shifted full bridge zero voltage switching DC/DC converter is proposed. The converter efficiency is maximized due to soft switching of the full bridge MOSFETs and the synchronous MOSFETs, and also the low conduction loss of synchronous MOSFET. The operation principles of the circuit are analyzed in detail and the small-signal model is derived, also the converter dynamic characteristics are analyzed. Frequency responses of transfer functions under different values of transformer primary leakage inductance are discussed. The experimental results were obtained from a 400 V input and 100 A/12 V output DC/DC converter operating at 100 kHz. The results show that the converter efficiency is 2% higher in rated power than traditional diode rectifier.
文摘DC distribution networks are often employed in isolated power systems like in marine and aeronautical applications. An interesting alternative to DC machines for the supply of DC grids is constituted by a three-phase alternator feeding an AC/DC rectifier. In this paper, alternative solutions are investigated where the AC alternator is equipped with more (iV) three-phase windings and feeds the DC load through more (N) cascade-connected rectifiers. The advantages of this solution with respect to the conventional three-phase topology are highlighted along with their dependence on the number (N) of the alternator windings. For this purpose, test results are reported and discussed on a prototype generator whose stator coils can be differently connected to obtained one, two, three or four windings. The major benefits (in terms of DC output current quality and field current ripple) are found when passing from the three-phase solution to the dual winding topology; conversely, relatively little advantage is gained by increasing the number of stator windings above two.
基金supported in part by the Natural Science Foundation of Shaanxi Province under Grant 2023JCQN0534in part by the Natural Science Foundation of Shaanxi Provincial Department of Education under Grant 23JK0660in part by the Xi’an Municipal Bureau of Science and Technology under Grant 24GXF0085。
文摘The information of the field current is essential for the brushless synchronous starter/generator system,which determines the performance and health status of this system.However,since the field winding of the main machine is installed in the rotor part,the measurement of the field current in this brushless system seem impossible.Considering that,the field current might be affected by the rectifier mode,the field current estimation method in different rectifier mode is studied in this paper.The main exciter(ME)rotor currents were restructured based on the ME flux equations.With these restructured rotor currents,the field current in different rectifier commutation mode is analyzed,then the field current estimation method considering the rectifier mode can be obtained.The experiments in different rectifier modes are carried out to verify the proposed method.