The unstable state of nitrite results in its very low concentration in seawater, which is below the limit of detection (LOD) of conventional techniques of analysis. Some sensitivity-enhanced methods have been propos...The unstable state of nitrite results in its very low concentration in seawater, which is below the limit of detection (LOD) of conventional techniques of analysis. Some sensitivity-enhanced methods have been proposed for the determination of nitrite at nanomolar level to illustrate the role of nitrite in the marine nitrogen cycle. However, most of previous reports are not widely accepted, because of their complexity and cost equipment or intensive labor requirement. In this study, a simple automatic system for the determination of nanomolar level nitrite using on-line preconcentration with spectrophotometric detection was described..An Oasis HLB cartridge was adopted to quantitatively enrich the pink-colored azo compound, formed from nitrite via Griess reaction. The cartridge was rinsed with water and ethanol (volume fraction is 55%, the same below), in turn, then eluted by an eluent containing 50% ethanol and 0.25 M(mol/dm^3) H2SO4, and determined at 543 nm with a 2 cm path-length flow cell. Under the optimized experimental conditions, the calibration curve showed a good linearity in the range of 1.4 85.7 aM, and the LOD (3a) was estimated to be 0.5 nM. The relative standard deviations of 7 measurements were 4.0% and 1.0% for the samples spiked at 7.1 and 28.6 nM, respectively. The recoveries for the different natural water samples were between 92.2%-108.4%. Each HLB cartridge could be reused for at least 50 times. As compared with other SPE methods, the advantages of this method included the free of interference from salinity variation and less sample consuming. The results of the application of the proposed method to natural water showed good agreement with liquid waveguide capillary cell detection method.展开更多
On the basis of oxidative decoloration of bromopyrogallol red (BPR) with H2O2, catalyzed by horseradish peroxidase( HRP), and the sequential injection renewable surface technique( SI-RST), a highly sensitive opt...On the basis of oxidative decoloration of bromopyrogallol red (BPR) with H2O2, catalyzed by horseradish peroxidase( HRP), and the sequential injection renewable surface technique( SI-RST), a highly sensitive optical-fiber sensor spectrophotometric method for the enzymatic determination of hydrogen peroxide was proposed. By coupling with a glucose oxidase(GOD)-catalyzed reaction, the method was used to determine glucose in human serum. The considerations in system and flow cell design, and factors that influence the determination performance are discussed. With 100μL of sample loaded and 0. 6 mg of bead trapped, the linear response range from 5.0 × 10^-8 to 5.2 × 10^-6 mol/L BPR with a detection limit(3σ) of 2. 5 ×10 ^-8 mol/L BPR, and a precision of 1.1% RSD( n = 11 ) and a throughput of a 80 samples per hour can be achieved. Under the conditions of a 8. 7 × 10^ -6 mol/L BPR substrate, 0. 04 unit/mL HRP, 600 s reaction time and a reaction temperature of 37℃, the linear response range for H2O2 was from 5.0 × 10^-8 to 7.0 × 10^-6 mol/L with a detection limit(3σ) of 1.0 × 10^-8 mol/L and a precision of 3.7% RSD ( n = 11 ). The linear response range by coupling with a GOD-catalyzed reaction was from 1.0 × 10^-7 to 1.0 × 10^-5 mol/L. The method was directly applied to determine glucose in human serum. Glucose contents obtained by the proposed procedure were compared with those obtained by using the phenol-4-AAP method, the error was found to be less than 3%.展开更多
Previously, we developed a novel siRNA transfer method to the liver by sequential intravenous injection of poly-L-glutamic acid (PGA) and cationic liposome/siRNA complex (cationic lipoplex). In this study, we examined...Previously, we developed a novel siRNA transfer method to the liver by sequential intravenous injection of poly-L-glutamic acid (PGA) and cationic liposome/siRNA complex (cationic lipoplex). In this study, we examined the effects of the charge ratio (+/-) of cationic liposome/siRNA, molecular weight of PGA and cationic lipid of cationic liposome on the biodistribution of siRNA after sequential injection of PGA plus cationic lipoplex. When 1,2-dioleoyl-3-trimethylammonium-propane (DOTAP)/cholesterol (Chol) lipoplex was intravenously injected into mice, the accumulation of siRNA was mainly observed in the lungs. In contrast, when DOTAP/Chol lipoplex was intravenously injected at 1 min after intravenous injection of PGA, siRNA was largely accumulated in the liver. The charge ratio (+/-) of DOTAP/Chol liposome/siRNA did not affect the biodistribution of siRNA after sequential injection. As regards the molecular weight of PGA, the accumulation of siRNA was observed mainly in the liver after the sequential injection of PGA of 20.5, 38, 64 or 200 kDa plus DOTAP/Chol lipoplex. Furthermore, to examine the effect of cationic lipid of cationic liposome on the biodistribution of siRNA, we prepared other cationic liposomes composed of 1,2-di-O-octadecenyl-3-trimethylammonium propane chloride (DOTMA)/Chol, dimethyldioctade-cylammonium bromide (DDAB)/Chol and O,O’-ditetradecanoyl-N-(α-trimethylammonioacetyl)di-ethanolamine chloride (DC-6-14)/Chol. For the cationic liposomes, the accumulation of siRNA was observed mainly in the liver when their cationic lipoplexes were sequentially injected after injection of PGA into mice. From these findings, sequential injection of PGA plus cationic lipoplex could deliver siRNA efficiently into the liver regardless of the charge ratio (+/-) of lipoplex, lengths of PGA and cationic lipid of liposome.展开更多
A sequential injection analysis (SIA) system for the determination of total calcium in blood has been implemented. The assay principle is based on the arsenazo III method, in which the indicator’s complex with calciu...A sequential injection analysis (SIA) system for the determination of total calcium in blood has been implemented. The assay principle is based on the arsenazo III method, in which the indicator’s complex with calcium forms a blue-purple colour. The absorbance peak height at 650 nm was proportional to the calcium content in samples. A linear range was obtained from 2.5 - 15 mg?dL–1 (r2 = 0.999), with a detection limit of 0.430 mg?dL–1 (3σ). Magnesium, glucose, hae-moglobin, and bilirubin at 123, 1,000, 50, and 0.5 mg?dL–1, respectively, were not found to interfere with the proposed system significantly (recovery 99.1% - 104.4%). The sampling frequency was 30 h–1, in which the carry-over effect was negligible (0.69%). The proposed SIA system was successfully applied to the determination of calcium from serum samples (r2 = 0.970;n = 30).展开更多
In this article, we discuss the existence and uniqueness of solutions for a coupled two-parameter system of sequential fractional integro-differential equations supplemented with nonlocal integro-multipoint boundary c...In this article, we discuss the existence and uniqueness of solutions for a coupled two-parameter system of sequential fractional integro-differential equations supplemented with nonlocal integro-multipoint boundary conditions. The standard tools of the fixed-point theory are employed to obtain the main results. We emphasize that our results are not only new in the given configuration, but also correspond to several new special cases for specific values of the parameters involved in the problem at hand.展开更多
The dashboard is the most important part of the large inner decoration of cars;it should not only have enough strength and rigidity,but also have a harmonious body model which can unify the theme.Besides,it needs to r...The dashboard is the most important part of the large inner decoration of cars;it should not only have enough strength and rigidity,but also have a harmonious body model which can unify the theme.Besides,it needs to reach the goal of lightweight.In order to achieve these three goals,the car dashboard is made by engineering-plastics and adopts the technology of injection moulding.This paper introduces the keys of design and the advanced technology of large injection moulding for car dashboard.展开更多
A sequential injection analysis (SIA) system based on polydimethylsiloxane (PDMS) chip with integrated pneumatic-actuated valves was developed. A novel SIA operation mode using multiphase laminar flow effect and pneum...A sequential injection analysis (SIA) system based on polydimethylsiloxane (PDMS) chip with integrated pneumatic-actuated valves was developed. A novel SIA operation mode using multiphase laminar flow effect and pneumatic microvalve control was proposed. The sample and reagent solutions were synchronously loaded and injected in the chip-based sample injection module instead of multi-step sequential injection by a multiposition valve and a reciprocating pump as in conventional SIA system. The sample and reagent injection volumes were reduced to ca. 1.1 nL. The present system has the advantages of simple structure, fast and convenient operation, low sample and reagent consumption, and high degree of integration and automation. The system operation conditions were optimized using fluorescein as model sample. Its feasibility in biological analysis was preliminarily demonstrated in enzyme inhibition assay.展开更多
Trace of Pb(Ⅱ) has been on-line separated and enriched from environmental samples and wastewater by using the self-made alizarin violet functionalized silica gel micro-column coupling with a sequential injection samp...Trace of Pb(Ⅱ) has been on-line separated and enriched from environmental samples and wastewater by using the self-made alizarin violet functionalized silica gel micro-column coupling with a sequential injection sampling technology. The determination is based on the color reaction of Pb(Ⅱ) with iodide and crystal violet to form an ionic association complex in the presence of polyvinyl alcohol and hydrochloric acid. The use of the microcolumn can prevent the interference of most familiar metal ions, and therefore improve the selectivity and sensitivity of this analytical technique. The proposed method was used for the determination of Pb(Ⅱ) in environmental samples and wastewater. No statistically significant difference was observed between the results determined by the present method and atomic absorption spectrometry.展开更多
基金The National High Technology Research and Development Program of China under contract Nos 2006AA09Z174 and 2007AA061501the National Natural Science Foundation of China under contract No. 40521003
文摘The unstable state of nitrite results in its very low concentration in seawater, which is below the limit of detection (LOD) of conventional techniques of analysis. Some sensitivity-enhanced methods have been proposed for the determination of nitrite at nanomolar level to illustrate the role of nitrite in the marine nitrogen cycle. However, most of previous reports are not widely accepted, because of their complexity and cost equipment or intensive labor requirement. In this study, a simple automatic system for the determination of nanomolar level nitrite using on-line preconcentration with spectrophotometric detection was described..An Oasis HLB cartridge was adopted to quantitatively enrich the pink-colored azo compound, formed from nitrite via Griess reaction. The cartridge was rinsed with water and ethanol (volume fraction is 55%, the same below), in turn, then eluted by an eluent containing 50% ethanol and 0.25 M(mol/dm^3) H2SO4, and determined at 543 nm with a 2 cm path-length flow cell. Under the optimized experimental conditions, the calibration curve showed a good linearity in the range of 1.4 85.7 aM, and the LOD (3a) was estimated to be 0.5 nM. The relative standard deviations of 7 measurements were 4.0% and 1.0% for the samples spiked at 7.1 and 28.6 nM, respectively. The recoveries for the different natural water samples were between 92.2%-108.4%. Each HLB cartridge could be reused for at least 50 times. As compared with other SPE methods, the advantages of this method included the free of interference from salinity variation and less sample consuming. The results of the application of the proposed method to natural water showed good agreement with liquid waveguide capillary cell detection method.
文摘On the basis of oxidative decoloration of bromopyrogallol red (BPR) with H2O2, catalyzed by horseradish peroxidase( HRP), and the sequential injection renewable surface technique( SI-RST), a highly sensitive optical-fiber sensor spectrophotometric method for the enzymatic determination of hydrogen peroxide was proposed. By coupling with a glucose oxidase(GOD)-catalyzed reaction, the method was used to determine glucose in human serum. The considerations in system and flow cell design, and factors that influence the determination performance are discussed. With 100μL of sample loaded and 0. 6 mg of bead trapped, the linear response range from 5.0 × 10^-8 to 5.2 × 10^-6 mol/L BPR with a detection limit(3σ) of 2. 5 ×10 ^-8 mol/L BPR, and a precision of 1.1% RSD( n = 11 ) and a throughput of a 80 samples per hour can be achieved. Under the conditions of a 8. 7 × 10^ -6 mol/L BPR substrate, 0. 04 unit/mL HRP, 600 s reaction time and a reaction temperature of 37℃, the linear response range for H2O2 was from 5.0 × 10^-8 to 7.0 × 10^-6 mol/L with a detection limit(3σ) of 1.0 × 10^-8 mol/L and a precision of 3.7% RSD ( n = 11 ). The linear response range by coupling with a GOD-catalyzed reaction was from 1.0 × 10^-7 to 1.0 × 10^-5 mol/L. The method was directly applied to determine glucose in human serum. Glucose contents obtained by the proposed procedure were compared with those obtained by using the phenol-4-AAP method, the error was found to be less than 3%.
文摘Previously, we developed a novel siRNA transfer method to the liver by sequential intravenous injection of poly-L-glutamic acid (PGA) and cationic liposome/siRNA complex (cationic lipoplex). In this study, we examined the effects of the charge ratio (+/-) of cationic liposome/siRNA, molecular weight of PGA and cationic lipid of cationic liposome on the biodistribution of siRNA after sequential injection of PGA plus cationic lipoplex. When 1,2-dioleoyl-3-trimethylammonium-propane (DOTAP)/cholesterol (Chol) lipoplex was intravenously injected into mice, the accumulation of siRNA was mainly observed in the lungs. In contrast, when DOTAP/Chol lipoplex was intravenously injected at 1 min after intravenous injection of PGA, siRNA was largely accumulated in the liver. The charge ratio (+/-) of DOTAP/Chol liposome/siRNA did not affect the biodistribution of siRNA after sequential injection. As regards the molecular weight of PGA, the accumulation of siRNA was observed mainly in the liver after the sequential injection of PGA of 20.5, 38, 64 or 200 kDa plus DOTAP/Chol lipoplex. Furthermore, to examine the effect of cationic lipid of cationic liposome on the biodistribution of siRNA, we prepared other cationic liposomes composed of 1,2-di-O-octadecenyl-3-trimethylammonium propane chloride (DOTMA)/Chol, dimethyldioctade-cylammonium bromide (DDAB)/Chol and O,O’-ditetradecanoyl-N-(α-trimethylammonioacetyl)di-ethanolamine chloride (DC-6-14)/Chol. For the cationic liposomes, the accumulation of siRNA was observed mainly in the liver when their cationic lipoplexes were sequentially injected after injection of PGA into mice. From these findings, sequential injection of PGA plus cationic lipoplex could deliver siRNA efficiently into the liver regardless of the charge ratio (+/-) of lipoplex, lengths of PGA and cationic lipid of liposome.
文摘A sequential injection analysis (SIA) system for the determination of total calcium in blood has been implemented. The assay principle is based on the arsenazo III method, in which the indicator’s complex with calcium forms a blue-purple colour. The absorbance peak height at 650 nm was proportional to the calcium content in samples. A linear range was obtained from 2.5 - 15 mg?dL–1 (r2 = 0.999), with a detection limit of 0.430 mg?dL–1 (3σ). Magnesium, glucose, hae-moglobin, and bilirubin at 123, 1,000, 50, and 0.5 mg?dL–1, respectively, were not found to interfere with the proposed system significantly (recovery 99.1% - 104.4%). The sampling frequency was 30 h–1, in which the carry-over effect was negligible (0.69%). The proposed SIA system was successfully applied to the determination of calcium from serum samples (r2 = 0.970;n = 30).
文摘In this article, we discuss the existence and uniqueness of solutions for a coupled two-parameter system of sequential fractional integro-differential equations supplemented with nonlocal integro-multipoint boundary conditions. The standard tools of the fixed-point theory are employed to obtain the main results. We emphasize that our results are not only new in the given configuration, but also correspond to several new special cases for specific values of the parameters involved in the problem at hand.
文摘The dashboard is the most important part of the large inner decoration of cars;it should not only have enough strength and rigidity,but also have a harmonious body model which can unify the theme.Besides,it needs to reach the goal of lightweight.In order to achieve these three goals,the car dashboard is made by engineering-plastics and adopts the technology of injection moulding.This paper introduces the keys of design and the advanced technology of large injection moulding for car dashboard.
基金supported by the National Natural Science Foundation of China (20825517, 20890020)Ministry of Science and Technology of China (2007CB714503)
文摘A sequential injection analysis (SIA) system based on polydimethylsiloxane (PDMS) chip with integrated pneumatic-actuated valves was developed. A novel SIA operation mode using multiphase laminar flow effect and pneumatic microvalve control was proposed. The sample and reagent solutions were synchronously loaded and injected in the chip-based sample injection module instead of multi-step sequential injection by a multiposition valve and a reciprocating pump as in conventional SIA system. The sample and reagent injection volumes were reduced to ca. 1.1 nL. The present system has the advantages of simple structure, fast and convenient operation, low sample and reagent consumption, and high degree of integration and automation. The system operation conditions were optimized using fluorescein as model sample. Its feasibility in biological analysis was preliminarily demonstrated in enzyme inhibition assay.
基金supported by the Science and Technology Department of Henan Province (082300423202 & 102300410194)
文摘Trace of Pb(Ⅱ) has been on-line separated and enriched from environmental samples and wastewater by using the self-made alizarin violet functionalized silica gel micro-column coupling with a sequential injection sampling technology. The determination is based on the color reaction of Pb(Ⅱ) with iodide and crystal violet to form an ionic association complex in the presence of polyvinyl alcohol and hydrochloric acid. The use of the microcolumn can prevent the interference of most familiar metal ions, and therefore improve the selectivity and sensitivity of this analytical technique. The proposed method was used for the determination of Pb(Ⅱ) in environmental samples and wastewater. No statistically significant difference was observed between the results determined by the present method and atomic absorption spectrometry.