A heat exchanger that arranges flat tubes horizontally has a vertical header that distributes the refrigerant to each tube. When the heat exchanger works as an evaporator, differences in flow conditions at each branch...A heat exchanger that arranges flat tubes horizontally has a vertical header that distributes the refrigerant to each tube. When the heat exchanger works as an evaporator, differences in flow conditions at each branch, such as the ratio and distribution of vapor and liquid, due to the differences in densities and momentums of vapor and liquid in the two-phase flow make equal distribution difficult. This paper describes the distribution characteristics of a four-branch header that has a rectangular cross-section without the internal protrusion of flat tubes in the case of the inflow of the refrigerant R32 from the bottom of the header by using an equipment that can estimate the distribution ratio of the liquid and vapor phase to each branch. This paper also discusses the distribution characteristics on the basis of the flow visualization in the header. The flow visualization shows that a liquid level that contains vapor phase exists in the header and affects the distribution greatly.展开更多
At turbomachinery relevant flow conditions the boundary layers are often transitional with laminar-to-turbulent transition occurring. The characteristics of the main flow can depend highly on the state of the boundary...At turbomachinery relevant flow conditions the boundary layers are often transitional with laminar-to-turbulent transition occurring. The characteristics of the main flow can depend highly on the state of the boundary layer. Therefore it can be vitally important for the designer to understand the process of laminar-to-turbulent transition and to determine the position and length of the transitional region. In this paper the flow over a flat plate is experimentally studied in order to investigate and better understand transitional flow. Preston tube measurements as well as a thermographic camera system were performed for two different inlet velocities in order to determine the position of the transitional zone. The results of the experiment are compared to numerical flow solutions using a common transition model to determine its capability. The simulation has been performed with the two commercial codes CFX and Fluent by Ansys and an in-house code called LINARS. As a result of this study, a better understanding of the experimental and numerical methods for determining transition shall be given.展开更多
文摘A heat exchanger that arranges flat tubes horizontally has a vertical header that distributes the refrigerant to each tube. When the heat exchanger works as an evaporator, differences in flow conditions at each branch, such as the ratio and distribution of vapor and liquid, due to the differences in densities and momentums of vapor and liquid in the two-phase flow make equal distribution difficult. This paper describes the distribution characteristics of a four-branch header that has a rectangular cross-section without the internal protrusion of flat tubes in the case of the inflow of the refrigerant R32 from the bottom of the header by using an equipment that can estimate the distribution ratio of the liquid and vapor phase to each branch. This paper also discusses the distribution characteristics on the basis of the flow visualization in the header. The flow visualization shows that a liquid level that contains vapor phase exists in the header and affects the distribution greatly.
文摘At turbomachinery relevant flow conditions the boundary layers are often transitional with laminar-to-turbulent transition occurring. The characteristics of the main flow can depend highly on the state of the boundary layer. Therefore it can be vitally important for the designer to understand the process of laminar-to-turbulent transition and to determine the position and length of the transitional region. In this paper the flow over a flat plate is experimentally studied in order to investigate and better understand transitional flow. Preston tube measurements as well as a thermographic camera system were performed for two different inlet velocities in order to determine the position of the transitional zone. The results of the experiment are compared to numerical flow solutions using a common transition model to determine its capability. The simulation has been performed with the two commercial codes CFX and Fluent by Ansys and an in-house code called LINARS. As a result of this study, a better understanding of the experimental and numerical methods for determining transition shall be given.