期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Development of a Rapid Multi-residue Assay for Detecting β-lactams Using Penicillin Binding Protein 2x 被引量:7
1
作者 ZENG Kum ZHANG Jing +4 位作者 WANG Yang WANG ZhanHui ZHANG Su Xia WU Chong Ming SHEN Jian Zhong 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2013年第2期100-109,共10页
Objective To develop a rapid multi-residue assay for detecting 16 demanded by the European Union (EU). Methods A recombinant penicillin-binding protein (PBP) 2x* from Streptococcus pneumoniae R6 was expressed in ... Objective To develop a rapid multi-residue assay for detecting 16 demanded by the European Union (EU). Methods A recombinant penicillin-binding protein (PBP) 2x* from Streptococcus pneumoniae R6 was expressed in vitro and six β-1actams were conjugated to HRP by four methods. A rapid multi-residue assay for β-1actams was established with PBP2x* and HRP-conjugate. Results PBP2x* was expressed and purified successfully and the ideal HRP-conjugate was identified. The multi-residue assay was developed. After optimization, penicillin G, ampicillin, amoxicillin, cloxacillin, dicloxacillin, oxacillin, nafcillin, cephalexin, ceftiofur, cefalonium, cefquinome, cefazolin, cefoperazone, cephacetrile, and cephapirin can be detected at levels below MRL in milk with simple pretreatment. Conclusion This assay developed can detect all 16 β-1actams demanded by the European Union (EU). The whole procedure takes only 45 min and can detect 42 samples and the standards with duplicate analysis. 展开更多
关键词 Penicillin-Binding Protein 2x* β-1actam multi-residue MILK
下载PDF
Multi-Residue Determination of Eight Anabolic Steroids by GC-MS in Muscle Tissues from Pigs 被引量:10
2
作者 ZENG Dong-ping, LIN Cui-ping, ZENG Zhen-ling, HUANG Xian-hui and HE Li-min Laboratory of Veterinary Pharmacology, College of Veterinary Medicine, South China Agricultural University, Guangzhou 510640, P.R. China 《Agricultural Sciences in China》 CSCD 2010年第2期306-312,共7页
A gas chromatography-mass spectrometry (GC-MS) method to determine eight anabolic steroids (diethylstilbestrol, methyltestosterone, norethindrone, 17α-ethynylestradiol, estradiol, 6α-methyl-17α-hydroxy-progester... A gas chromatography-mass spectrometry (GC-MS) method to determine eight anabolic steroids (diethylstilbestrol, methyltestosterone, norethindrone, 17α-ethynylestradiol, estradiol, 6α-methyl-17α-hydroxy-progesterone, estradiol benzoate, and chlormadinone acetate) was developed. Muscle samples were extracted with liquid-liquid extraction and clean-up was performed in two steps, the extracts obtained were derivatized with heptafluorbutyric (HBF) anhydride and analyzed by GC-MS. In the above method, the linear scope was 2.5-50 μg kg^-1. The range of the recoveries was 78.5-148% for diethylstilbestrol, 70.8-109% for methyltestosterone, 69.8-87.2% for norethindrone, 67.7-120% for 17α-ethynylestradiol, 82.8-103% for estradiol, 70.3-99.2% for 6α-methyl-17α-hydroxy-progesterone, 73.0-104% for estradiol benzoate, and 72.9- 91.8% for chlormadinone acetate. The range of the coefficients of variation within batches was 0.4-12%; the range of the coefficients of variation between batches was 6.4-11%. The limit of detections and the detection capability were 0.99 and 3.30 μg kg^-1 for diethylstilbestrol, 1.05 and 3.50 μg kg^-1 for methyltestosterone, 1.19 and 3.97 μg kg^-1 for norethindrone, 0.94 and 3.13 μg kg^-1 for 17α-ethynylestradiol, 1.45 and 4.83 μg kg^-1 for estradiol, 1.56 and 5.20 μg kg^-1 for 6α-methyl-17α- hydroxy-progesterone, 1.92 and 6.40 μg kg^-1 for estradiol benzoate, and 2.41 and 8.03 μg kg^-1 for chlormadinone acetate, respectively. These results showed that the method was widely available, accurate, and sensitive. 展开更多
关键词 anabolic steroids GC-MS multi-residue determination PIGS
下载PDF
On-site rapid detection of multiple pesticide residues in tea leaves by lateral flow immunoassay
3
作者 Junxia Gao Tianyi Zhang +7 位作者 Yihua Fang Ying Zhao Mei Yang Li Zhao Ye Li Jun Huang Guonian Zhu Yirong Guo 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2024年第2期276-283,共8页
The application of pesticides (mostly insecticides and fungicides) during the tea-planting process will undoubtedly increase the dietary risk associated with drinking tea. Thus, it is necessary to ascertain whether pe... The application of pesticides (mostly insecticides and fungicides) during the tea-planting process will undoubtedly increase the dietary risk associated with drinking tea. Thus, it is necessary to ascertain whether pesticide residues in tea products exceed the maximum residue limits. However, the complex matrices present in tea samples comprise a major challenge in the analytical detection of pesticide residues. In this study, nine types of lateral flow immunochromatographic strips (LFICSs) were developed to detect the pesticides of interest (fenpropathrin, chlorpyrifos, imidacloprid, thiamethoxam, acetamiprid, carbendazim, chlorothalonil, pyraclostrobin, and iprodione). To reduce the interference of tea substrates on the assay sensitivity, the pretreatment conditions for tea samples, including the extraction solvent, extraction time, and purification agent, were optimized for the simultaneous detection of these pesticides. The entire testing procedure (including pretreatment and detection) could be completed within 30 min. The detected results of authentic tea samples were confirmed by ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS), which suggest that the LFICS coupled with sample rapid pretreatment can be used for on-site rapid screening of the target pesticide in tea products prior to their market release. 展开更多
关键词 Lateral flow immunoassay Rapid detection Pesticide multi-residue Tea matrix Sample rapid pretreatment
下载PDF
Simultaneous Screening of 733 Pesticide Residues in Fruits and Vegetables by a GC/LC-Q-TOFMS Combination Technique 被引量:13
4
作者 Guofang Pang Qiaoying Chang +4 位作者 Ruobin Bai Chunlin Fan Zijuan Zhang Hongyuan Yan Xingqiang Wu 《Engineering》 SCIE EI 2020年第4期432-441,共10页
In this paper,we report the construction of two accurate mass databases and the development of a combination detection method that simultaneously screens for 733 pesticide and chemical contaminant multi-residues via h... In this paper,we report the construction of two accurate mass databases and the development of a combination detection method that simultaneously screens for 733 pesticide and chemical contaminant multi-residues via high-throughput liquid chromatography(LC)-and gas chromatography(GC)-quadru pole-time-of-flight mass spectrometry(Q-TOFMS).This work demonstrates that electronic mass spectral standards may replace chemical-source standard materials as references through one sample preparation and the combination of GC/LC-Q-TOFMS screening.This cutting-edge technique has also replaced multiresidue determination using targeted detection with non-targeted screening.The pesticide residue types,sensitivity,recovery,and reproducibility of this combination technique are evaluated in eight fruit and vegetable matrices.This technique shows three advantages:①In comparison with the discovery capability of a single technique,the combination technique shows an improvement of 51.1%(GC-QTOFMS)and 39.6%(LC-Q-TOFMS),respectively;②the combination technique can satisfy a screening limit lower than 10μg·kg^-1 and meet the requirements of“uniform standards,”although some of the pesticide residues could be optimized to further improve screening sensitivity;③over 488 pesticides with recoveries between 60%-120%and relative standard deviation(RSD)<20%at a spiked level of 10μg·kg^-1 were detected with the combination technique in eight different matrices.From 2012 to 2017,this combination technique was applied in an investigation to screen pesticide residues from 1384 sampling locations for 38138 batched samples covering 18 categories and 134 types of fruits and vegetables obtained from across the mainland of China.After statistical analysis,533 pesticides in 115891 determinations were detected,and the regularity of pesticides in the fruits and vegetables sold on the Chinese market was shown. 展开更多
关键词 Pesticide multi-residues GC-Q-TOFMS LC-Q-TOFMS Accurate mass database Spectra library Fruits and vegetables
下载PDF
Multiresidue Method for Determination of 67 Pesticides in Water Samples Using Solid-Phase Extraction with Centrifugation and Gas Chromatography-Mass Spectrometry 被引量:3
5
作者 Abir Kouzayha Abdul Rahman Rabaa +3 位作者 Mohamad Al Iskandarani Daniel Beh Hélène Budzinski Farouk Jaber 《American Journal of Analytical Chemistry》 2012年第3期257-265,共9页
A new multi-residue method based on solid-phase extraction (SPE) with centrifugation was developed for determination and quantitation of 67 pesticides in water samples. Two SPE cartridges were tested: Chromabond C18 a... A new multi-residue method based on solid-phase extraction (SPE) with centrifugation was developed for determination and quantitation of 67 pesticides in water samples. Two SPE cartridges were tested: Chromabond C18 and Oasis HLB. Parameters that influence the extraction efficiency such as the eluent volume, the sample loading volume, the addition of organic solvent to water sample, sorbent drying and elute concentration were optimized. The innovation of this work was the examination of the use of a centrifugation technique in both the drying and elution steps. When combined with centrifugation, the volume of the elution solvent was reduced to 2 mL and the time for sorbent drying decreased also to 10 min under vacuum. Under the optimized conditions, this method showed good recoveries higher than 65% - 68% for the 67 analyzed pesticides using the C18 and HLB cartridges with relative standard deviations lower than 9.7% - 12.3%. Limits of quantification were between 2 and 20 ng.L–1. The simplicity of the described method, use of less of organic solvent, short procedure time, and good recoveries demonstrate the advantages of this environmentally friendly approach for routine analysis of numerous samples. 展开更多
关键词 multi-residue PESTICIDES SOLID-PHASE Extraction CENTRIFUGATION Gas Chromatography-Mass SPECTROMETRY
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部