期刊文献+
共找到29篇文章
< 1 2 >
每页显示 20 50 100
A Space Vector PWM Scheme for Multilevel Inverters Based on Two-Level Space Vector PWM 被引量:1
1
《变频器世界》 2006年第12期26-27,共2页
Ⅰ. INTRODUCTION MULTILEVEL inverters are increasingly being used in high-power medium voltage applications due to their superior performance compared to two-level inverters, such as lower common-mode voltage, lower d... Ⅰ. INTRODUCTION MULTILEVEL inverters are increasingly being used in high-power medium voltage applications due to their superior performance compared to two-level inverters, such as lower common-mode voltage, lower dv/dt, lower harmonics in output voltage and current, and reduced voltage on the power switches. 展开更多
关键词 A Space Vector PWM Scheme for multilevel inverters Based on Two-Level Space Vector PWM In
下载PDF
Fast Online Diagnosis of Open-circuit Switching Faults in Flying Capacitor Multilevel Inverters 被引量:1
2
作者 Majid T.Fard Waqar A.Khan +2 位作者 Jiangbiao He Nathan Weise Mostafa Abarzadeh 《Chinese Journal of Electrical Engineering》 CSCD 2020年第4期53-62,共10页
Flying capacitor multilevel(FCML)inverter is an attractive power converter topology which provides high-quality staircase output voltage waveforms by cascading flying capacitor cells.However,the large number of semico... Flying capacitor multilevel(FCML)inverter is an attractive power converter topology which provides high-quality staircase output voltage waveforms by cascading flying capacitor cells.However,the large number of semiconductor devices utilized in the FCML inverters degrades the hardware reliability,which may constrain such converters from being applied in safety-critical applications.Targeting at open-circuit switching faults,a fast online fault diagnostic method for FCML inverters is presented.Conventional phase-shifted PWM(PSPWM),which can naturally balance the voltage across flying capacitors,is used as the modulation method in this work.Hence,to retain the simplicity feature of the PSPWM,the proposed diagnostic method is developed so that it does not require any voltage measurements of flying capacitors.Only the output AC voltage and current data along with the switching PWM signals from the microcontroller are needed to detect an open-circuit switching fault,and all such sensory data is typically available in the inverter,requiring no additional sensors or hardware for the implementation of this diagnostic method.The detection process takes 5% of the fundamental period of the inverter output signals to diagnose the faulty switch.Simulation and experimental results are presented to verify the effectiveness of the proposed diagnostic method. 展开更多
关键词 Open-circuit fault diagnosis flying capacitor multilevel inverter wide bandgap devices PSPWM
原文传递
A Sensor-less Surface Mounted PMSM for Electronic Speed Control in Multilevel Inverter
3
作者 S.Dinesh Kumar A.Jagadeeshwaran 《Intelligent Automation & Soft Computing》 SCIE 2023年第5期2201-2215,共15页
Recent advancements in power electronics technology evolves inverter fed electric motors.Speed signals and rotor position are essential for controlling an electric motor accurately.In this paper,the sensorless speed c... Recent advancements in power electronics technology evolves inverter fed electric motors.Speed signals and rotor position are essential for controlling an electric motor accurately.In this paper,the sensorless speed control of surface-mounted permanent magnet synchronous motor(SPMSM)has been attempted.SPMSM wants a digital inverter for its precise working.Hence,this study incor-poratesfifteen level inverter to the SPMSM.A sliding mode observer(SMO)based sensorless speed control scheme is projected to determine rotor spot and speed of the multilevel inverter(MLI)fed SPMSM.MLI has been operated using a multi carrier pulse width modulation(MCPWM)strategy for generation offif-teen level voltages.The simulation works are executed with MATLAB/SIMU-LINK software.The steadiness and the heftiness of the projected model have been investigated under no loaded and loaded situations of SPMSM.Furthermore,the projected method can be adapted for electric vehicles. 展开更多
关键词 Surface-mounted permanent magnet synchronous motor sensorless speed control multilevel inverter torque estimation multi carrier pulse width modulation
下载PDF
Analysis of Reduced Switch Topology Multilevel Inverter with Different Pulse Width Modulation Technique and Its Application with DSTATCOM 被引量:1
4
作者 Sambasivam Rajalakshmi Parthasarathy Rangarajan 《Circuits and Systems》 2016年第9期2410-2424,共15页
Multilevel inverter has played a vital role in medium and high power applications in the recent years. In this paper, Reduced Switch Count Multi Level Inverter structure (RSCMLI) topology is presented with different p... Multilevel inverter has played a vital role in medium and high power applications in the recent years. In this paper, Reduced Switch Count Multi Level Inverter structure (RSCMLI) topology is presented with different pulse width modulation techniques. The harmonic level analysis is carried out for the reduced switch count multilevel inverter with the different PWM technique such as with Alternate Phase Opposition Disposition (APOD) method, In Phase Disposition (IPD) method and multi reference pulse width modulation method for five level, seven level , nine level and eleven level inverter. The simulation results are compared with the cascaded H Bridge Multi Level Inverter (CHBMLI). The nine level RSCMLI inverter with APOD method is used for the Distribution Static Synchronous Compensator (DSTATCOM) application in the nonlinear load connected system for power factor improvement. The result shows that the harmonic level and the number of switches required for RSCMLI is reduced compared to CHBMLI. RSCMLI employed in DSTATCOM improves the power factor and harmonic level of the system when it is connected to the nonlinear load. 展开更多
关键词 Reduced Switch Count multilevel Inverter PWM Method Harmonic Level DSTATCOM
下载PDF
Minimization of Switching Devices and Driver Circuits in Multilevel Inverter
5
作者 S. Jawahar P. Ramamoorthy 《Circuits and Systems》 2016年第10期3371-3383,共13页
The various configurations of multilevel inverter involve the use of more numbers of switching devices, energy storage devices and/or unidirectional devices. Each switching unit necessitates the add-on driver circuit ... The various configurations of multilevel inverter involve the use of more numbers of switching devices, energy storage devices and/or unidirectional devices. Each switching unit necessitates the add-on driver circuit for proper functionality. Cascaded H-Bridge Multilevel Inverter requires overlapped switching pulses for the switching devices in positive and negative arms of the bridge which may lead to short circuit during the device failure. This work addresses the problems in different configurations of multilevel inverter by using reduced number of switching and energy storage devices and driver circuits. In the present approach Single Switch is used for each stair case positive output and single H-Bridge for phase reversal. Driver circuits are reduced by using the property of body diode of the MOSFET. Switching pulses are generated by Arduino Development Board. The circuit is simulated using Matlab. More so, through experimental means, it is physically tested and results are analyzed for the 5-step inverter and thereby simulation is fully validated. Consequently, cycloconverter operation of the circuit is simulated using Matlab. Moreover, half bridge configuration of the multilevel inverter is also analyzed for high frequency induction heating applications. 展开更多
关键词 H-Bridge multilevel Inverter Single Switch multilevel Inverter Body Diode Switching Angle THD CYCLOCONVERTER Half Bridge multilevel Inverter
下载PDF
Intelligent-Based Maximum Power Extraction on Grid-Integrated Multilevel Inverter-Fed Wind-Driven Induction Generators
6
作者 B. Meenakshi Sundaram B. V. Manikandan H. Habeebullah Sait 《Circuits and Systems》 2016年第9期2551-2567,共17页
This paper presents an intelligent controller employing Adaptive Neuro-Fuzzy Inference System (ANFIS) for extracting maximum power from the wind energy conversion system even during the change in the wind speed condit... This paper presents an intelligent controller employing Adaptive Neuro-Fuzzy Inference System (ANFIS) for extracting maximum power from the wind energy conversion system even during the change in the wind speed conditions with improved quality of power. The proposed induction generator with multilevel inverter along with intelligent controller based Maximum Power Point Tracking (MPPT) technique aims at integrating winds system with improved maximum power injection and minimum harmonic issues. The proposed method will improve the power quality which is delivered to the grid in terms of harmonic, and inject the maximum power to the grid. To validate the effectiveness of the proposed control strategy, ANFIS controller, Fuzzy Inference System (FIS) and without MPPT controller have been presented and tested using MATLAB/Simulink environment. 展开更多
关键词 Wind Energy multilevel Inverter MPPT Technique ANFIS FIS HARMONICS
下载PDF
A Novel Asymmetrical Single-Phase Multilevel Inverter Suitable for Hybrid Renewable Energy Sources
7
作者 C. P. Boopathy M. Kaliamoorthy 《Circuits and Systems》 2016年第6期932-945,共14页
This paper introduces a novel single-phase asymmetrical multilevel inverter suitable for hybrid renewable energy sources. The proposed inverter consists of two isolated DC sources and six power semiconductor controlle... This paper introduces a novel single-phase asymmetrical multilevel inverter suitable for hybrid renewable energy sources. The proposed inverter consists of two isolated DC sources and six power semiconductor controlled switches. The suggested inverter is capable of generating seven-level output when the input DC voltage is taken in the ratio of 1:2. The higher magnitude DC source is fed from Photo Voltaic (PV) panels, whereas the lower magnitude DC source is fed from Wind Turbine (WT) driven Permanent Magnet DC (PMDC) generator. Both the renewable energy sources are connected to the inverter via two DC-DC boost converters connected in cascade (i.e. one for maximum power point tracking and another for DC-link voltage control). The proposed hybrid renewable energy source inverter is connected to single-phase grid via proper control systems. The complete system is simulated using MATLAB/SIMULINK and the results are presented in detail. 展开更多
关键词 Asymmetrical multilevel Inverter DC-DC Boost Converter Photo-Voltaic Wind Turbine Permanent Magnet DC Generator Maximum Power Point Tracking
下载PDF
Hybrid Control Strategy for BCD Topology Based Modular Multilevel Inverter
8
作者 Vasudevan Karthikeyan gopal Jamuna 《Circuits and Systems》 2016年第8期1441-1454,共14页
In this paper, a Binary Coded Decimal (BCD) topology of modular multilevel inverter with reduced component count is proposed. For the control of this inverter, hybrid control strategy is used. The proposed modular mul... In this paper, a Binary Coded Decimal (BCD) topology of modular multilevel inverter with reduced component count is proposed. For the control of this inverter, hybrid control strategy is used. The proposed modular multilevel inverter uses asymmetrical dc sources and reduced number of switches topology. This hybrid modulation technique uses the multicarrier based Pulse Width Modulation (PWM) and the fundamental frequency modulation strategy. The hybrid modulation algorithm is implemented with “NUC140” micro-controller. In comparison with the conventional and some of the recently reported inverter topologies, the proposed inverter topology is able to generate high number of voltage levels in the output by using minimum number of components such as dc sources, power switches and driver circuits. This inverter offers significant performance with less number of components. The feasibility of the proposed topology is confirmed by simulation and experimental results. 展开更多
关键词 multilevel Inverter Reduced Components Hybrid PWM Asymmetrical dc Sources Harmonic Distortion
下载PDF
Analysis of Symmetrical and Asymmetrical Current Source Multilevel Inverter
9
作者 D. Tamilarasi T. S. Sivakumaran 《Circuits and Systems》 2016年第11期3469-3484,共17页
The paper proposes a Current Source Multilevel Inverter (CSMLI) with single rating inductor topology. Multilevel inverters are most familiar with power converter’s applications due to reduced dv/dt, di/dt stress, and... The paper proposes a Current Source Multilevel Inverter (CSMLI) with single rating inductor topology. Multilevel inverters are most familiar with power converter’s applications due to reduced dv/dt, di/dt stress, and very efficient for reducing harmonic distortion in the output voltage and output current. The proposed nine-level current source inverter has been tested under symmetrical and asymmetrical modes of operation, and their activities are compared using PI and Fuzzy PI (Proportional Integral) controllers with multicarrier PWM (Pulse Width Modulation) strategy. MATLAB/Simulink simulation has been made for the proposed converter to obtain its performance measures. Some experimental results are given to verify the presented Current Source Multilevel Inverter. 展开更多
关键词 Current Source Inverter multilevel Inverter Multicarrier PWM Total Harmonic Dis-tortion Fuzzy PI Controller
下载PDF
A New Topology for a Single Phase Multilevel Voltage Source Inverter with Reduced Number of Components
10
作者 Lijo Jacob Varghese C. Kezi Selva Vijila I. Jacob Ragland 《Circuits and Systems》 2016年第4期475-488,共14页
Multilevel inverters have gained much attention for its operation involving applications ranging values of high power rating. This paper proposes a switching topology for asymmetric multilevel inverter utilizing less ... Multilevel inverters have gained much attention for its operation involving applications ranging values of high power rating. This paper proposes a switching topology for asymmetric multilevel inverter utilizing less number of power electronics components. When the number of the output level increases, it requires more switching states and eventually the number of switching components. The increased number of switches results in higher switching losses which may lead to power loss, and reduction of efficiency of the overall conversion system. The salient feature of this proposed topology is that the module can be used as a sub multiple level structure and can be extended for any number of level with minimal increase in the switching components. 展开更多
关键词 multilevel Inverter Asymmetrical Inverter Reduction of Components Loss Calculation Total Harmonic Distortion
下载PDF
Harmonic Minimization in Seven-Level Cascaded Multilevel Inverter Using Evolutionary Algorithm
11
作者 Jeyabharath Rajaiah Velmurugan Ramar Veena Parasunath 《Circuits and Systems》 2016年第9期2309-2322,共14页
Inverters are power electronic devices that change over DC to sinusoidal AC quantity. Be that as it may, in down to earth, these devices produce non-sinusoidal yield which contains harmonics, so as to blend a close si... Inverters are power electronic devices that change over DC to sinusoidal AC quantity. Be that as it may, in down to earth, these devices produce non-sinusoidal yield which contains harmonics, so as to blend a close sinusoidal component and to lessen the harmonic distortion multilevel inverters developed. Mathematical methods, which were developed, are derivative based and need initial considerations. To overcome this, evolutionary algorithms, which are derivative free and accurate, were developed for obtaining multi levels of output voltage. The proposed work uses two evolutionary algorithms, namely, Genetic Algorithm (GA) and Particle Swarm Optimization (PSO) algorithm. These algorithms are used to generate the switching angles by satisfying the non linear transcendental equations that govern the low order harmonic components. A seven level cascaded full bridge inverter is designed using MATLAB/Simulink and the results validate the results for switching angles. The Total Harmonic Distortion (THD) value obtained for GA and PSO is 11.81% and 10.84% respectively. The solution obtained from GA algorithm was implemented in hardware using dsPIC controller to validate the simulation results. The THD value obtained for cascaded seven-level multilevel inverter in the hardware prototype is 25.9%. 展开更多
关键词 multilevel Inverter Selective Harmonic Elimination Genetic Algorithm Particle Swarm Optimization Harmonic Minimization
下载PDF
Asymmetric Three-Phase Cascading Trinary-DC Source Multilevel Inverter Topologies for Variable Frequency PWM
12
作者 G. Irusapparajan D. Periyaazhagar 《Circuits and Systems》 2016年第4期506-519,共14页
Asymmetric three-phase cascading Trinary-DC source Multilevel Inverter which can achieve reduced harmonics and superior root mean square (RMS) values of the output voltage is proposed. This topology can achieve cascad... Asymmetric three-phase cascading Trinary-DC source Multilevel Inverter which can achieve reduced harmonics and superior root mean square (RMS) values of the output voltage is proposed. This topology can achieve cascaded full bridge inverter operation with dissimilar (unequal) DC Source and it is fired by using variable frequency pulse with modulation technique as a switching strategy. This pulse width modulation switching strategy has a newly adopted multicarrier single reference technique. The performance parameter factors like Form Factor (FF), Crest Factor (CF), Total Harmonic Distortion (THD) and fundamental RMS output voltage (V<sub>RMS</sub>) are estimated by using proposed asymmetrical three-phase cascading multilevel inverter for several modulation indices (0.8 - 1). The research study carries with MATLAB/SIMULINK based simulation and experimental results obtained using appropriate prototype (test board) to prove the viability of the proposed concept. 展开更多
关键词 Trinary multilevel Inverter Variable Frequency Pulse Width Modulation Total Harmonic Distortions Trinary-DC Source Distortion Factor
下载PDF
Harmonic Minimization in Seven Level Cascaded Multilevel Inverter Using Selective Harmonic Elimination PWM Techniques
13
作者 V. R. Velmurugan Jeyabharath Rajaiah Veena Parasunath 《Circuits and Systems》 2016年第14期4322-4330,共10页
This paper concentrates on enhancing the productivity of the multilevel inverter and nature of yield voltage waveform. Seven level lessened switches topology has been actualized with just seven switches. Essential Swi... This paper concentrates on enhancing the productivity of the multilevel inverter and nature of yield voltage waveform. Seven level lessened switches topology has been actualized with just seven switches. Essential Switching plan and Selective Harmonics Elimination were executed to diminish the Total Harmonics Distortion (THD) esteem. Selective Harmonics Elimination Stepped Waveform (SHESW) strategy is executed to dispense with the lower order harmonics. Fundamental switching plan is utilized to control the switches in the inverter. The proposed topology is reasonable for any number of levels. The harmonic lessening is accomplished by selecting fitting switching angles. It indicates would like to decrease starting expense and unpredictability consequently it is able for modern applications. In this paper, third and fifth level harmonics have been disposed of. Simulation work is done utilizing the MATLAB/Simulink programming results have been displayed to accept the hypothesis. 展开更多
关键词 multilevel Inverter PSIM Fundamental Switching Scheme Selective Harmonics Elimination
下载PDF
Capacitor Pattern H-Bridge Multilevel Inverter (CPHMLI) Using Phase Diposition Pulse Width Modulation for Grid Applications
14
作者 M. S. Saravanan R. Jeyabharath 《Circuits and Systems》 2016年第10期3310-3319,共10页
This work presents an implementation of an innovative single phase multilevel inverter using capacitors with reduced switches. The proposed Capacitor pattern H-bridge Multilevel Inverter (CPHMLI) topology consists of ... This work presents an implementation of an innovative single phase multilevel inverter using capacitors with reduced switches. The proposed Capacitor pattern H-bridge Multilevel Inverter (CPHMLI) topology consists of a proper number of Capacitor connected with switches and power sources. The advanced switching control supplied by Pulse Width Modulation (PDPWM) to attain mixed staircase switching state. The charging and discharging mode are achieved by calculating the voltage error at the load. Furthermore, to accomplish the higher voltage levels at the output with less number of semiconductors switches and simple commutation designed using CPHMLI topology. To prove the performance and effectiveness of the proposed approach, a set of experiments performed under various load conditions using MATLAB tool. 展开更多
关键词 Switched Capacitor multilevel Inverter Phase Diposition Pulse Width Modulation Capacitor Pattern Based multilevel Inverter Total Harmonic Distortion Cascaded H-Bridge 17-Level Inverter
下载PDF
State Space Modeling and Implementation of a New Transformer Based Multilevel Inverter Topology with Reduced Switch Count
15
作者 R. Gandhi Raj S. Palani H. Habeebullah Sait 《Circuits and Systems》 2016年第4期446-463,共18页
This paper presents a new transformer based multilevel inverter, with a novel pulse width modulation scheme to achieve seven-level inverter output voltage. The proposed inverter switching pattern consists of three fun... This paper presents a new transformer based multilevel inverter, with a novel pulse width modulation scheme to achieve seven-level inverter output voltage. The proposed inverter switching pattern consists of three fundamental frequency sinusoidal reference signals with an offset value, and one high frequency triangular carrier signal. This switching scheme has been implemented using an 8-bit Xilinx SPARTAN-3E field programmable gate array based controller. In addition, the state space model of the proposed inverter is developed. The significant features of the proposed topology are: reduction of the power switch count and the gate drive power supply unit, the provision of a galvanic isolation between load and sources by a centre tap transformer. An exhaustive comparison has been made of the existing multilevel inverter topologies and the proposed topology. The performances of the proposed topology with resistive, resistive-inductive loads are simulated in a MATLAB environment and validated experimentally on a laboratory prototype. 展开更多
关键词 Centre Tap Transformer Field Programmable Gate Array (FPGA) multilevel Inverter (MLI) Pulse Width Modulation (PWM) State Space Model
下载PDF
A Cascade Multilevel Inverter Using a Single DC Source
16
《变频器世界》 2006年第10期25-27,共3页
3.SWITCHING ANGLES If the nominal capacitor voltage is chosen as Vdc/2, then one can compute the switching anglesθ1,θ2,andθ3.Following the development,the Fourier series expan- sion of the(staircase)output voltage ... 3.SWITCHING ANGLES If the nominal capacitor voltage is chosen as Vdc/2, then one can compute the switching anglesθ1,θ2,andθ3.Following the development,the Fourier series expan- sion of the(staircase)output voltage waveform of the multilevel inverter as shown in Fig.2(a) 展开更多
关键词 DC In A Cascade multilevel Inverter Using a Single DC Source
下载PDF
Modeling and Analysis of Variable Frequency Inverted Sine PWM Technique for a Hybrid Cascaded Multilevel Inverter
17
作者 M. Sudhakaran R. Seyezhai 《Circuits and Systems》 2016年第9期2633-2650,共18页
In cascaded H-bridge multilevel inverter, a variable frequency inverted sine PWM technique is modeled for hybrid electric vehicles. It has a particular advantage of increasing power which is achieved using series conn... In cascaded H-bridge multilevel inverter, a variable frequency inverted sine PWM technique is modeled for hybrid electric vehicles. It has a particular advantage of increasing power which is achieved using series connection of H-bridge and also this topology is capable to produce superior spectral quality with considerable improvement of fundamental voltage. The variable frequency inverted sine PWM technique produces lesser torque ripple and enhances the fundamental output voltage mainly at lower modulation index ranges. The topologies of multilevel inverter are flying capacitor, diode clamped and cascaded inverter. In the paper, we will discuss about the cascaded multilevel inverter based on inverted sine PWM technique. The two switching strategies widely used to control multilevel inverters are constant frequency inverted sine PWM (CF-ISPWM) and variable frequency inverted sine PWM (VF-ISPWM). This implies that switch utilization substantially reduces 32.35% of the constant frequency inverted sine PWM switching technique. The performance of the technique is validated in terms of Total Harmonic Distortion (THD) and Torque ripple which significantly reduces when compared to constant frequency ISPWM. The analysis of conventional triangular PWM inverter and inverted sine PWM inverter using constant and variable switching scheme is done in MATLAB Simulink and verified experimentally by FPGA Spartan 3E processor. 展开更多
关键词 Cascaded multilevel Inverter Constant Frequency Inverted Sine PWM Variable Frequency Inverted Sine PWM Total Harmonic Distortion
下载PDF
A Novel Multilevel Inverter Employing Additive and Subtractive Topology
18
作者 V. Prasannamoorthy P. Sundaramoorthi Merin Jacob 《Circuits and Systems》 2016年第9期2425-2436,共12页
As the demand for high voltage, high power inverters are increasing and there is a problem of connecting a power semiconductor switch directly to a high voltage network. As a part of this the multilevel inverters had ... As the demand for high voltage, high power inverters are increasing and there is a problem of connecting a power semiconductor switch directly to a high voltage network. As a part of this the multilevel inverters had been introduced. As a part of this, several researches had been done for the development of multilevel inverters. The commercially available and extensively studied topologies for multilevel voltage output are Neutral Point Clamped (NPC), Cascaded Half Bridge (CHB) and Flying Capacitor (FC) converters. However, with these existing topologies, there is a significant increase in the number of power switches and passive components. Thus it leads to more complex control circuitry and overall cost of the system increase with increase in the output levels. In this paper, a novel multilevel inverter is proposed in which it employs additive and subtractive topology to get higher output levels. This approach significantly reduces the number of power switches needed as compared to existing topology. The present developed multilevel inverter can generate only five voltage levels. With this proposed topology the multilevel inverter can be modified to nine-level inverter. Moreover modified hybrid multicarrier Pulse Width Modulation (PWM) technique can be implemented in the proposed multilevel inverter in order to obtain uniform switch utilization and lower THD. An appropriate modulation scheme is presented and also the proposed concept is analyzed through simulation studies. 展开更多
关键词 multilevel Inverter (MLI) Pulse Width Modulation (PWM) Multicarrier PWM Scheme Additive and Subtractive Topology Total Harmonic Distortion (THD)
下载PDF
Performance Metric of Z Source CHB Multilevel Inverter FED IM for Selective Harmonic Elimination and THD Reduction
19
作者 V. Maheswari V. Nandagopal C. Kannan 《Circuits and Systems》 2016年第11期3794-3806,共14页
This paper focuses on a Z source cascaded multilevel inverter which is designed to minimize harmonics in the output voltage. A balanced dc-link peak voltage can be achieved. The power generation module is built by PV ... This paper focuses on a Z source cascaded multilevel inverter which is designed to minimize harmonics in the output voltage. A balanced dc-link peak voltage can be achieved. The power generation module is built by PV panels which are connected to Z-Source Cascade H-bridge inverter. Cascaded multilevel inverter can achieve the distributed maximum power point tracking to increase the system efficiency and achieve high voltage/high power grid tie without a transformer. This paper analyzes the different PWM switching scheme and the operating states of a ZSI module and comparison is made with different PWM and total harmonic distortion of various PWM schemes. 展开更多
关键词 Z Source Inverter Cascade H Bridge multilevel Inverter Photovoltaic System
下载PDF
Development of Energy Management System for Micro Grid Operation
20
作者 S.Jayaprakash B.Gopi +3 位作者 Murugananth Gopal Raj S.Sujith S.Deepa S.Swapna 《Computer Systems Science & Engineering》 SCIE EI 2023年第6期2537-2551,共15页
The introduction of several small and large-scale industries,malls,shopping complexes,and domestic applications has significantly increased energy consumption.The aim of the work is to simulate a technically viable an... The introduction of several small and large-scale industries,malls,shopping complexes,and domestic applications has significantly increased energy consumption.The aim of the work is to simulate a technically viable and economically optimum hybrid power system for residential buildings.The proposed micro-grid model includes four power generators:solar power,wind power,Electricity Board(EB)source,and a Diesel Generator(DG)set,with solar and wind power performing as major sources and the EB supply and DG set serving as backup sources.The core issue in direct current to alternate current conversion is harmonics distortion,a five-stage multilevel inverter is employed with the assistance of an intelligent control system is simulated and the optimum system configuration is estimated to reduce harmonics and improve the power quality.The monthly demand for residential buildings is 13-15 Megawatts.So,almost 433 Kilo-Watts(KW)of electricity is required every day,and if it is used for 8 h per day,50-60 KW of electricity is needed per hour.The overall micro-grid model’s operation and performance are established using MATLAB/SIMULINK software,and simulation results are provided.The simulation results show that the developed system is both cost-effective and environment friendly resulting in yearly cost reductions. 展开更多
关键词 MICROGRID energy management system intelligent control system multilevel inverter power plants
下载PDF
上一页 1 2 下一页 到第