Active multiple tuned mass dampers (referred to as AMTMD), which consist of several active tuned mass dampers (ATMDs) with identical stiffness and damping coefficients but varying mass and control force, have rece...Active multiple tuned mass dampers (referred to as AMTMD), which consist of several active tuned mass dampers (ATMDs) with identical stiffness and damping coefficients but varying mass and control force, have recently been proposed to suppress undesirable oscillations of structures under ground acceleration. It has been shown that the AMTMD can remarkably improve the performance of multiple tuned mass dampers (MTMDs) and is also more effective in reducing structure oscillation than single ATMDs. Notwithstanding this, good performance of AMTMD (including a single ATMD illustrated from frequency-domain analysis) may not necessarily translate into a good seismic reduction behavior in the time-domain. To investigate these phenomena, a three-story steel structure model controlled by AMTMD with three ATMDs was implemented in SIMULINK and subjected to several historical earthquakes. Likewise, the structure under consideration was assumed to have uncertainty of stiffness, such as 4-15% of its initial stiffness, in the numerical simulations. The optimum design parameters of the AMTMD were obtained in the frequency-domain by implementing the minimization of the minimum values of the maximum dynamic magnification factors (DMF) of general structures with AMTMD. For comparison purposes, response analysis of the same structure with a single ATMD was also performed. The numerical analysis and comparison show that the AMTMD generally renders better effectiveness when compared with a single ATMD for structures subjected to historical earthquakes. In particular, the AMTMD can improve the effectiveness of a single ATMD for a structure with an uncertainty of stiffness of 4-15% of its initial stiffness.展开更多
The dynamics of jacket supported offshore wind turbine (OWT) in earthquake environment is one of the progressing focuses in the renewable energy field. Soil-structure interaction (SSI) is a fundamental principle t...The dynamics of jacket supported offshore wind turbine (OWT) in earthquake environment is one of the progressing focuses in the renewable energy field. Soil-structure interaction (SSI) is a fundamental principle to analyze stability and safety of the structure. This study focuses on the performance of the multiple tuned mass damper (MTMD) in minimizing the dynamic responses of the structures objected to seismic loads combined with static wind and wave loads. Response surface methodology (RSM) has been applied to design the MTMD parameters. The analyses have been performed under two different boundary conditions: fixed base (without SSI) and flexible base (with SSI). Two vibration modes of the structure have been suppressed by multi-mode vibration control principle in both cases. The effectiveness of the MTMD in reducing the dynamic response of the structure is presented. The dynamic SSI plays an important role in the seismic behavior of the jacket supported OWT, especially resting on the soft soil deposit. Finally, it shows that excluding the SSI effect could be the reason of overestimating the MTMD performance.展开更多
大型化工管道受管内流体流动、边界约束、振源激励等复杂因素影响,服役期间往往会发生振动,其振动频率相较于土木结构较高,且可能存在多个主要频率成分.若采用单一频率的调谐质量阻尼器(Tuned Mass Damper,TMD),难以达到理想的控制效果...大型化工管道受管内流体流动、边界约束、振源激励等复杂因素影响,服役期间往往会发生振动,其振动频率相较于土木结构较高,且可能存在多个主要频率成分.若采用单一频率的调谐质量阻尼器(Tuned Mass Damper,TMD),难以达到理想的控制效果,而采用多重调谐质量阻尼器(Multiple Tuned Mass Damper,MTMD)时,受现场条件限制,又存在无法确定最优安装位置等问题.本文开展了基于MTMD的管道倍频响应减振研究.首先,开展了某化工企业丙烷脱氢装置的大型管道现场实测研究,发现管道振动频率存在明显的倍数关系,即倍频现象.其次,建立局部管道有限元模型,分析管道动力特性,提出了基于数值搜索法的MTMD参数设计方法.最后,考虑化工管道现场安装条件的限制,研究了MTMD安装位置对管道减振效果的影响.数值研究结果表明,安装MTMD可有效减小管道振动响应.展开更多
为研究多重调谐质量阻尼器(Multiple Tuned Mass Damper,MTMD)抑制桥梁单阶涡振的性能,建立桥梁结构-MTMD系统竖弯涡振广义单自由度动力方程,以某大跨度悬索桥为背景进行MTMD减振控制效果和参数优化分析。采用数值方法求解动力方程,获...为研究多重调谐质量阻尼器(Multiple Tuned Mass Damper,MTMD)抑制桥梁单阶涡振的性能,建立桥梁结构-MTMD系统竖弯涡振广义单自由度动力方程,以某大跨度悬索桥为背景进行MTMD减振控制效果和参数优化分析。采用数值方法求解动力方程,获得系统在简谐涡激力下达到稳态谐振时结构的动力放大系数和MTMD对结构的附加模态阻尼比,并与单一频率调谐质量阻尼器(Single Tuned Mass Damper,STMD)的减振控制效果进行对比,然后以附加模态阻尼比为目标对MTMD进行参数优化。结果表明:MTMD比最优参数STMD拥有更宽的控制频带和更好的减振效果,经优化后的MTMD减振性能优于最优参数STMD。实际应用MTMD时,应选择较大广义质量、5~7种频率规格,并根据二者找到无量纲频率范围和各TMD阻尼比的惟一最优取值。展开更多
This paper presents a procedure to develop fragility curves of structures equipped with TMD considering multiple failure functions.The failure criteria considered are maximum inter-story drift ratio as a safety criter...This paper presents a procedure to develop fragility curves of structures equipped with TMD considering multiple failure functions.The failure criteria considered are maximum inter-story drift ratio as a safety criterion,maximum absolute acceleration as a convenience criterion and TMD stroke length.The relationship between intensity measure and responses of the structure was assumed to follow the power-law model,and a regression analysis was used to estimate its properties.A nonlinear eight-story shear building subjected to near-fault earthquakes was used for the numerical studies.Fragility curves using multiple and single failure functions for an uncontrolled structure and a structure equipped with optimal TMDs were developed.Numerical analysis showed that using multiple failure functions led to increasing the fragility when compared with using the single failure function for both the uncontrolled and controlled structures.However,TMDs slightly reduced the seismic fragility and have the capability to improve the reliability of the structure.Also,it was found that the fragility was significantly influenced by the values of the capacity thresholds of both the acceleration of the structure and TMD stroke length,which should be selected by considering the target performance and application of the structure and control device.展开更多
文摘Active multiple tuned mass dampers (referred to as AMTMD), which consist of several active tuned mass dampers (ATMDs) with identical stiffness and damping coefficients but varying mass and control force, have recently been proposed to suppress undesirable oscillations of structures under ground acceleration. It has been shown that the AMTMD can remarkably improve the performance of multiple tuned mass dampers (MTMDs) and is also more effective in reducing structure oscillation than single ATMDs. Notwithstanding this, good performance of AMTMD (including a single ATMD illustrated from frequency-domain analysis) may not necessarily translate into a good seismic reduction behavior in the time-domain. To investigate these phenomena, a three-story steel structure model controlled by AMTMD with three ATMDs was implemented in SIMULINK and subjected to several historical earthquakes. Likewise, the structure under consideration was assumed to have uncertainty of stiffness, such as 4-15% of its initial stiffness, in the numerical simulations. The optimum design parameters of the AMTMD were obtained in the frequency-domain by implementing the minimization of the minimum values of the maximum dynamic magnification factors (DMF) of general structures with AMTMD. For comparison purposes, response analysis of the same structure with a single ATMD was also performed. The numerical analysis and comparison show that the AMTMD generally renders better effectiveness when compared with a single ATMD for structures subjected to historical earthquakes. In particular, the AMTMD can improve the effectiveness of a single ATMD for a structure with an uncertainty of stiffness of 4-15% of its initial stiffness.
基金supported by a grant[MPSS-NH-2015-78]through the DisasterSafety Management Institute funded by Ministry of Public Safety and Security of Korean government
文摘The dynamics of jacket supported offshore wind turbine (OWT) in earthquake environment is one of the progressing focuses in the renewable energy field. Soil-structure interaction (SSI) is a fundamental principle to analyze stability and safety of the structure. This study focuses on the performance of the multiple tuned mass damper (MTMD) in minimizing the dynamic responses of the structures objected to seismic loads combined with static wind and wave loads. Response surface methodology (RSM) has been applied to design the MTMD parameters. The analyses have been performed under two different boundary conditions: fixed base (without SSI) and flexible base (with SSI). Two vibration modes of the structure have been suppressed by multi-mode vibration control principle in both cases. The effectiveness of the MTMD in reducing the dynamic response of the structure is presented. The dynamic SSI plays an important role in the seismic behavior of the jacket supported OWT, especially resting on the soft soil deposit. Finally, it shows that excluding the SSI effect could be the reason of overestimating the MTMD performance.
文摘大型化工管道受管内流体流动、边界约束、振源激励等复杂因素影响,服役期间往往会发生振动,其振动频率相较于土木结构较高,且可能存在多个主要频率成分.若采用单一频率的调谐质量阻尼器(Tuned Mass Damper,TMD),难以达到理想的控制效果,而采用多重调谐质量阻尼器(Multiple Tuned Mass Damper,MTMD)时,受现场条件限制,又存在无法确定最优安装位置等问题.本文开展了基于MTMD的管道倍频响应减振研究.首先,开展了某化工企业丙烷脱氢装置的大型管道现场实测研究,发现管道振动频率存在明显的倍数关系,即倍频现象.其次,建立局部管道有限元模型,分析管道动力特性,提出了基于数值搜索法的MTMD参数设计方法.最后,考虑化工管道现场安装条件的限制,研究了MTMD安装位置对管道减振效果的影响.数值研究结果表明,安装MTMD可有效减小管道振动响应.
文摘为研究多重调谐质量阻尼器(Multiple Tuned Mass Damper,MTMD)抑制桥梁单阶涡振的性能,建立桥梁结构-MTMD系统竖弯涡振广义单自由度动力方程,以某大跨度悬索桥为背景进行MTMD减振控制效果和参数优化分析。采用数值方法求解动力方程,获得系统在简谐涡激力下达到稳态谐振时结构的动力放大系数和MTMD对结构的附加模态阻尼比,并与单一频率调谐质量阻尼器(Single Tuned Mass Damper,STMD)的减振控制效果进行对比,然后以附加模态阻尼比为目标对MTMD进行参数优化。结果表明:MTMD比最优参数STMD拥有更宽的控制频带和更好的减振效果,经优化后的MTMD减振性能优于最优参数STMD。实际应用MTMD时,应选择较大广义质量、5~7种频率规格,并根据二者找到无量纲频率范围和各TMD阻尼比的惟一最优取值。
文摘This paper presents a procedure to develop fragility curves of structures equipped with TMD considering multiple failure functions.The failure criteria considered are maximum inter-story drift ratio as a safety criterion,maximum absolute acceleration as a convenience criterion and TMD stroke length.The relationship between intensity measure and responses of the structure was assumed to follow the power-law model,and a regression analysis was used to estimate its properties.A nonlinear eight-story shear building subjected to near-fault earthquakes was used for the numerical studies.Fragility curves using multiple and single failure functions for an uncontrolled structure and a structure equipped with optimal TMDs were developed.Numerical analysis showed that using multiple failure functions led to increasing the fragility when compared with using the single failure function for both the uncontrolled and controlled structures.However,TMDs slightly reduced the seismic fragility and have the capability to improve the reliability of the structure.Also,it was found that the fragility was significantly influenced by the values of the capacity thresholds of both the acceleration of the structure and TMD stroke length,which should be selected by considering the target performance and application of the structure and control device.