期刊文献+
共找到11,754篇文章
< 1 2 250 >
每页显示 20 50 100
Real-Time 4-Mode MDM Transmission Using Commercial 400G OTN Transceivers and All-Fiber Mode Multiplexers 被引量:1
1
作者 REN Fang LI Yidan +2 位作者 YE Bing LIU Jianguo CHEN Weizhang 《ZTE Communications》 2024年第1期106-110,共5页
Weakly-coupled mode division multiplexing(MDM)technique is considered a promising candidate to enhance the capacity of an optical transmission system,in which mode multiplexers/demultiplexers(MMUX/MDEMUX)with low inse... Weakly-coupled mode division multiplexing(MDM)technique is considered a promising candidate to enhance the capacity of an optical transmission system,in which mode multiplexers/demultiplexers(MMUX/MDEMUX)with low insertion loss and modal crosstalk are the key components.In this paper,a low-modal-crosstalk 4-mode MMUX/MDEMUX for the weakly-coupled triple-ring-core few-mode fiber(TRC-FMF)is designed and fabricated with side-polishing processing.The measurement results show that a pair of MMUX/MDEMUX and 25 km weakly-coupled TRC-FMF MDM link achieve low modal crosstalk of lower than−17.5 dB and insertion loss of lower than 11.56 dB for all the four modes.Based on the TRC-FMF and all-fiber MMUX/MDEMUX,an experiment for 25 km real-time 4-mode 3-λwavelength division multiplexing(WDM)-MDM transmission is conducted using commercial 400G optical transport network(OTN)transceivers.The experimental results prove weakly-coupled MDM techniques facilitate a smooth upgrade of the optical transmission system. 展开更多
关键词 optical fiber couplers mode(de)multiplexers mode division multiplexing transmission
下载PDF
Demonstration of a manufacturable SOT-MRAM multiplexer array towards industrial applications
2
作者 Chuanpeng Jiang Jinhao Li +14 位作者 Hongchao Zhang Shiyang Lu Pengbin Li Chao Wang Zhongkui Zhang Zhengyi Hou Xu Liu Jiagao Feng He Zhang Hui Jin Gefei Wang Hongxi Liu Kaihua Cao Zhaohao Wang Weisheng Zhao 《Journal of Semiconductors》 EI CAS CSCD 2023年第12期81-88,共8页
We have successfully demonstrated a 1 Kb spin-orbit torque(SOT)magnetic random-access memory(MRAM)multiplexer(MUX)array with remarkable performance.The 1 Kb MUX array exhibits an in-die function yield of over 99.6%.Ad... We have successfully demonstrated a 1 Kb spin-orbit torque(SOT)magnetic random-access memory(MRAM)multiplexer(MUX)array with remarkable performance.The 1 Kb MUX array exhibits an in-die function yield of over 99.6%.Additionally,it provides a sufficient readout window,with a TMR/RP_sigma%value of 21.4.Moreover,the SOT magnetic tunnel junctions(MTJs)in the array show write error rates as low as 10^(-6)without any ballooning effects or back-hopping behaviors,ensuring the write stability and reliability.This array achieves write operations in 20 ns and 1.2 V for an industrial-level temperature range from-40 to 125℃.Overall,the demonstrated array shows competitive specifications compared to the state-of-the-art works.Our work paves the way for the industrial-scale production of SOT-MRAM,moving this technology beyond R&D and towards widespread adoption. 展开更多
关键词 spin-orbit torque MRAM multiplexer array 200 mm-wafer platform stability reliability
下载PDF
Multi-dimensional multiplexing optical secret sharing framework with cascaded liquid crystal holograms 被引量:1
3
作者 Keyao Li Yiming Wang +6 位作者 Dapu Pi Baoli Li Haitao Luan Xinyuan Fang Peng Chen Yanqing Lu Min Gu 《Opto-Electronic Advances》 SCIE EI CAS CSCD 2024年第1期28-35,共8页
Secret sharing is a promising technology for information encryption by splitting the secret information into different shares.However,the traditional scheme suffers from information leakage in decryption process since... Secret sharing is a promising technology for information encryption by splitting the secret information into different shares.However,the traditional scheme suffers from information leakage in decryption process since the amount of available information channels is limited.Herein,we propose and demonstrate an optical secret sharing framework based on the multi-dimensional multiplexing liquid crystal(LC)holograms.The LC holograms are used as spatially separated shares to carry secret images.The polarization of the incident light and the distance between different shares are served as secret keys,which can significantly improve the information security and capacity.Besides,the decryption condition is also restricted by the applied external voltage due to the variant diffraction efficiency,which further increases the information security.In implementation,an artificial neural network(ANN)model is developed to carefully design the phase distribution of each LC hologram.With the advantage of high security,high capacity and simple configuration,our optical secret sharing framework has great potentials in optical encryption and dynamic holographic display. 展开更多
关键词 holographic encryption optical secret sharing cascaded liquid crystal hologram multi-dimensional multiplexing
下载PDF
Frequency-modulated continuous-wave multiplexed gas sensingbased on optical frequency comb calibration
4
作者 Linhua Jia Xinghua Qu Fumin Zhang 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第9期152-163,共12页
Laser absorption spectroscopy has proven to be an effective approach for gas sensing, which plays an important rolein the fields of military, industry, medicine and basic research. This paper presents a multiplexed ga... Laser absorption spectroscopy has proven to be an effective approach for gas sensing, which plays an important rolein the fields of military, industry, medicine and basic research. This paper presents a multiplexed gas sensing system basedon optical frequency comb (OFC) calibrated frequency-modulated continuous-wave (FMCW) tuning nonlinearity. Thesystem can be used for multi-parameter synchronous measurement of gas absorption spectrum and multiplexed opticalpath. Multi-channel parallel detection is realized by combining wavelength division multiplexing (WDM) and frequencydivision multiplexing (FDM) techniques. By introducing nonlinear optical crystals, broadband spectrum detection is simultaneouslyachieved over a bandwidth of hundreds of nanometers. An OFC with ultra-high frequency stability is used asthe frequency calibration source, which guarantees the measurement accuracy. The test samples involve H13C14N, C_(2)H_(2)and Rb vapor cells of varying densities and 5 parallel measurement experiments are designed. The results show that themeasurement accuracies of spectral absorption line and the optical path are 150 MHz and 20 m, respectively. The schemeoffers the advantages of multiplexed, multi-parameter, wide spectrum and high resolution detection, which can realize theidentification of multi-gas components and the high-precision inversion of absorption lines under different environments.The proposed sensor demonstrates great potential in the field of high-resolution absorption spectrum measurement for gassensing applications. 展开更多
关键词 frequency-modulated CONTINUOUS-WAVE (FMCW) technology optical FREQUENCY COMB multiplexING absorption spectroscopy
下载PDF
A Study of Radiation-Induced Telomere Instability Using Multiplex Ligation-Dependent Probe Amplification (MLPA)
5
作者 Alan Chant Ahmad Chaudary Christina M. Kraemer-Chant 《Advances in Biological Chemistry》 CAS 2024年第3期73-85,共13页
The integrity of the chromosomes for two WIL2-derived lymphoblastoid cell lines (TK6 and WTK1) in the presence and absence of ionizing radiation was analyzed by Multiplex Ligation-Dependent Probe Amplification (MLPA).... The integrity of the chromosomes for two WIL2-derived lymphoblastoid cell lines (TK6 and WTK1) in the presence and absence of ionizing radiation was analyzed by Multiplex Ligation-Dependent Probe Amplification (MLPA). The TK6 cell line has the native p53 tumor-suppressor gene, whereas WTK1 cells contain a p53 mutation. Each cell line was isolated pre- and post-irradiation (2 and 3 Gy) and analyzed by MLPA. The impact of irradiation on these two cell lines was investigated using probes that target specific regions on chromosomes associated with subtelomeric regions. Results indicate that WTK1 and TK6 are impacted differently after irradiation, and that each cell line presents its own unique MLPA profile. The most notable differences are the appearance of a number of probes in the post-irradiated MLPA profile that are not present in the controls, and two unique probe signals only seen in WTK1 cells. These results build on our previous studies that indicate how different human cell lines can be affected by radiation in significantly different ways depending on the presence or absence of wild type p53. 展开更多
关键词 Ionizing Radiation multiplex Ligation-Dependent Probe Amplification (MLPA) p53 Tumor Suppressor Telomere Instability
下载PDF
Study on Distribution of Four Pseudomonas Species in Living Environment Using Multiplex PCR
6
作者 Sachiyo Hayashi Koji Umezawa +12 位作者 Osamu Tsuzukibashi Akira Fukatsu Mana Fuchigami Chiaki Komine Hiroshi Yamamoto Mio Hagiwara-Hamano Yukiko Iizuka Satoshi Uchibori Masanobu Wakami Hiroshi Murakami Taira Kobayashi Masahiko Fukumoto Takato Nomoto 《Open Journal of Stomatology》 2024年第2期77-86,共10页
Purpose: The genus Pseudomonas is a ubiquitous microorganism frequently detected from immunocompromised patients. The inherent resistance to numerous antimicrobial agents contributes to the opportunistic character of ... Purpose: The genus Pseudomonas is a ubiquitous microorganism frequently detected from immunocompromised patients. The inherent resistance to numerous antimicrobial agents contributes to the opportunistic character of this pathogen exhaustive monitoring of this pathogen is considered of critical importance to public health organizations. The reliable identification method able to distinguish genetic close Pseudomonas species is needed, because these organisms are difficult to differentiate by phenotypic or biochemical methods. The purpose of the present study was to design species-specific primers in order to identify and detect four Pseudomonas species which are frequently detected from the human oral cavities, and to investigate the distribution of these organisms in the living environment using a multiplex PCR. Methods: Polymerase chain reaction (PCR) primers were designed based on partial sequences of the rpoD gene of four Pseudomonas species. Swab samples were collected from fifty washstands, and the distribution of Pseudomonas species was investigated using a conventional PCR at genus level and a multiplex PCR at species level. Results: Multiplex PCR method developed in this study was able to distinguish four Pseudomonas species clearly. The genus Pseudomonas was detected from all samples (100%), whereas P. putida, P, aeruginosa, P. stutzeri and P. fluorescens were detected at 44%, 8%, 4% and 2% in fifty swab samples, respectively. Conclusion: Our developed one-step multiplex PCR method is accurate, specific, cost-effective, time-saving, and works without requiring DNA extraction. It was indicated that washstands were the uninhabitable environment for P. putida, P, aeruginosa, P. stutzeri and P. fluorescens. 展开更多
关键词 Genus Pseudomonas multiplex PCR Living Environment
下载PDF
A simple and efficient CRISPR/Cas9 system permits ultra-multiplex genome editing in plants
7
作者 Suting Wu Htin Kyaw +11 位作者 Zhijun Tong Yirong Yang Zhiwei Wang Liying Zhang Lihua Deng Zhiguo Zhang Bingguang Xiao William Paul Quick Tiegang Lu Guoying Xiao Guannan Qin Xue'an Cui 《The Crop Journal》 SCIE CSCD 2024年第2期569-582,共14页
The development and maturation of the CRISPR/Cas genome editing system provides a valuable tool for plant functional genomics and genetic improvement.Currently available genome-editing tools have a limited number of t... The development and maturation of the CRISPR/Cas genome editing system provides a valuable tool for plant functional genomics and genetic improvement.Currently available genome-editing tools have a limited number of targets,restricting their application in genetic research.In this study,we developed a novel CRISPR/Cas9 plant ultra-multiplex genome editing system consisting of two template vectors,eight donor vectors,four destination vectors,and one primer-design software package.By combining the advantages of Golden Gate cloning to assemble multiple repetitive fragments and Gateway recombination to assemble large fragments and by changing the structure of the amplicons used to assemble sg RNA expression cassettes,the plant ultra-multiplex genome editing system can assemble a single binary vector targeting more than 40 genomic loci.A rice knockout vector containing 49 sg RNA expression cassettes was assembled and a high co-editing efficiency was observed.This plant ultra-multiplex genome editing system advances synthetic biology and plant genetic engineering. 展开更多
关键词 CRISPR/Cas9 multiplex genome editing Assembly system PLANT
下载PDF
Establishment and performance analysis of a new multiplex detection method for influenza an and B virus antigen
8
作者 Cheng-Jing Xia Bao-Hua Li +3 位作者 Yan-Ni Guo Xiao-He Zhou Run-Ling Zhang Ying-No Niu 《World Journal of Clinical Cases》 SCIE 2024年第23期5338-5345,共8页
BACKGROUND Influenza A and B virus detection is pivotal in epidemiological surveillance and disease management.Rapid and accurate diagnostic techniques are crucial for timely clinical intervention and outbreak prevent... BACKGROUND Influenza A and B virus detection is pivotal in epidemiological surveillance and disease management.Rapid and accurate diagnostic techniques are crucial for timely clinical intervention and outbreak prevention.Quantum dot-encoded microspheres have been widely used in immunodetection.The integration of quantum dot-encoded microspheres with flow cytometry is a well-established technique that enables rapid analysis.Thus,establishing a multiplex detection method for influenza A and B virus antigens based on flow cytometry quantum dot microspheres will help in disease diagnosis.AIM To establish a codetection method of influenza A and B virus antigens based on flow cytometry quantum dot-encoded microsphere technology,which forms the foundation for the assays of multiple respiratory virus biomarkers.METHODS Different quantum dot-encoded microspheres were used to couple the monoclonal antibodies against influenza A and B.The known influenza A and B antigens were detected both separately and simultaneously on a flow cytometer,and the detection conditions were optimized to establish the influenza A and B antigen codetection method,which was utilized for their detection in clinical samples.The results were compared with the fluorescence quantitative polymerase chain reaction(PCR)method to validate the clinical performance of this method.RESULTS The limits of detection of this method were 26.1 and 10.7 pg/mL for influenza A and B antigens,respectively,which both ranged from 15.6 to 250000 pg/mL.In the clinical sample evaluation,the proposed method well correlated with the fluorescent quantitative PCR method,with positive,negative,and overall compliance rates of 57.4%,100%,and 71.6%,respectively.CONCLUSION A multiplex assay for quantitative detection of influenza A and B virus antigens has been established,which is characterized by high sensitivity,good specificity,and a wide detection range and is promising for clinical applications. 展开更多
关键词 Influenza A Influenza B Quantum dot microspheres Antigen detection multiplex detection
下载PDF
Multiplex Rapid Test with Acceptable Diagnosis Performance as a Solution to Increase Diagnosis of Hepatitis B and C Viruses in Pregnant Women in an Area of High Prevalence of Both Hepatitis Viruses Associated with HIV
9
作者 Catherine Boni-Cisse Nina Esther Onstira Ngoyi +9 位作者 Hermione Dahlia Mossoro-Kpinde Noella Packo Rabi Senekian Hermann Ndoidet Koutou Coretha Bokia-Baguida Christelle Luce Bobossi-Gadia Arthur Simplice Sombot-Ndicky Daniel Yvon Gonessa Freddy Samuel Ngbonga Konzapa Voulou Christian Diamant Mossoro-Kpinde 《Open Journal of Medical Microbiology》 2024年第1期50-65,共16页
Background and Objective: HIV, hepatitis B virus (HBV) and hepatitis C virus (HCV) are very widespread in the world, however, less than 20% of the people affected are diagnosed and treated. This study aimed to determi... Background and Objective: HIV, hepatitis B virus (HBV) and hepatitis C virus (HCV) are very widespread in the world, however, less than 20% of the people affected are diagnosed and treated. This study aimed to determine the prevalence of HIV, HCV and HBV co-infections in pregnant women at Bangui Community University Hospital and the cost of screening. Methods: A cross-sectional study involving consenting pregnant women who came for antenatal care was performed. HIV, HCV antibodies and HBV antigens were detected using Exacto Triplex<sup>?</sup> HIV/HCV/HBsAg rapid test, cross-validated by ELISA tests. Sociodemographic and professional data, the modes of transmission and prevention of HIV and both hepatitis viruses were collected in a standard sheet and analyzed using the Epi-Info software version 7. Results: Pregnant women aged 15 to 24 were the most affected (45.3%);high school girls (46.0%), and pregnant women living in cohabitation (65.3%) were the most represented. Twenty-five (16.7%) worked in the formal sector, 12.7% were unemployed housewives and the remainder in the informal sector. The prevalence of HIV, HBV, and HCV viruses was 11.8%, 21.9% and 22.2%, respectively. The prevalence of co-infections was 8.6% for HIV-HBV, 10.2% for HIV-HCV, 14.7% for HBV-HCV and 6.5% for HIV-HBV-HCV. All positive results and 10% of negative results by the rapid test were confirmed by ELISA tests. The serology of the three viruses costs 39,000 FCFA (60 Euros) by ELISA compared to 10,000 FCFA (15.00 Euros) with Exacto Triplex<sup>?</sup> HIV/HCV/AgHBs (BioSynex, Strasbourg, France). Conclusion: The low level of education and awareness of hepatitis are barriers to development and indicate the importance of improving the literacy rate of women in the Central African Republic (CAR). Likewise, the high prevalence of the three viruses shows the need for the urgent establishment of a national program to combat viral hepatitis in the CAR. 展开更多
关键词 HIV-HCV-HBV Co-Infection multiplex Immunochromatographic Rapid Test Central Africa Serology Test Cost Diagnostic Accessibility
下载PDF
Semi-implantable device based on multiplexed microfilament electrode cluster for continuous monitoring of physiological ions
10
作者 Shuang Huang Shantao Zheng +9 位作者 Mengyi He Chuanjie Yao Xinshuo Huang Zhengjie Liu Qiangqiang Ouyang Jing Liu Feifei Wu Hang Gao Xi Xie Hui-jiuan Chen 《Bio-Design and Manufacturing》 SCIE EI CAS CSCD 2024年第1期88-103,共16页
Modern medicine is increasingly interested in advanced sensors to detect and analyze biochemical indicators.Ion sensors based on potentiometric methods are a promising platform for monitoring physiological ions in bio... Modern medicine is increasingly interested in advanced sensors to detect and analyze biochemical indicators.Ion sensors based on potentiometric methods are a promising platform for monitoring physiological ions in biological subjects.Current semi-implantable devices are mainly based on single-parameter detection.Miniaturized semi-implantable electrodes for multiparameter sensing have more restrictions on the electrode size due to biocompatibility considerations,but reducing the electrode surface area could potentially limit electrode sensitivity.This study developed a semi-implantable device system comprising a multiplexed microfilament electrode cluster(MMEC)and a printed circuit board for real-time monitoring of intra-tissue K^(+),Ca^(2+),and Na^(+)concentrations.The electrode surface area was less important for the potentiometric sensing mechanism,suggesting the feasibility of using a tiny fiber-like electrode for potentiometric sensing.The MMEC device exhibited a broad linear response(K^(+):2–32 mmol/L;Ca^(2+):0.5–4 mmol/L;Na^(+):10–160 mmol/L),high sensitivity(about 20–45 mV/decade),temporal stability(>2weeks),and good selectivity(>80%)for the above ions.In vitro detection and in vivo subcutaneous and brain experiment results showed that the MMEC system exhibits good multi-ion monitoring performance in several complex environments.This work provides a platform for the continuous real-time monitoring of ion fluctuations in different situations and has implications for developing smart sensors to monitor human health. 展开更多
关键词 multiplexed microfilament electrode cluster Physiological ion sensing Subcutaneous and brain experiment Wearable platform for multi-ion detection Continuous real-time monitoring system
下载PDF
Development of a multiplex polymerase chain reaction assay for detection of hepatitis C virus,hepatitis B virus,and human immunodeficiency virus 1
11
作者 Waleed Abdelgaber Nemr Radwan K Nashwa 《World Journal of Virology》 2024年第1期95-106,共12页
BACKGROUND Hepatitis C virus(HCV),hepatitis B virus(HBV),and human immunodeficiency virus 1(HIV-1)are the most epidemic blood-borne viruses,posing threats to human health and causing economic losses to nations for com... BACKGROUND Hepatitis C virus(HCV),hepatitis B virus(HBV),and human immunodeficiency virus 1(HIV-1)are the most epidemic blood-borne viruses,posing threats to human health and causing economic losses to nations for combating the infection transmission.The diagnostic methodologies that depend on the detection of viral nucleic acids are much more expensive,but they are more accurate than sero-logical testing.AIM To develop a rapid,cost-effective,and accurate diagnostic multiplex polymerase chain reaction(PCR)assay for simultaneous detection of HCV,HBV,and HIV-1.METHODS The design of the proposed PCR assay targets the amplification of a short conserved region featured with a distinguishable melting profile and electro-phoretic molecular weight inside each viral genome.Therefore,this diagnostic method will be appropriate for application in both conventional(combined with electrophoresis)and real-time PCR facilities.Confirmatory in silico investigations were conducted to prove the capability of the approached PCR assay to detect variants of each virus.Then,Egyptian isolates of each virus were subjected to the wet lab examination using the given diagnostic assay.RESULTS The in silico investigations confirmed that the PCR primers can match many viral variants in a multiplex PCR assay.The wet lab experiment proved the efficiency of the assay in distinguishing each viral type through high-resolution melting analysis.Compared to related published assays,the proposed assay in the current study is more sensitive and competitive with many expensive PCR assays.CONCLUSION This study provides a simple,cost-effective,and sensitive diagnostic PCR assay facilitating the detection of the most epidemic blood-borne viruses;this makes the proposed assay promising to be substitutive for the mistakable and cheap serological-based assays. 展开更多
关键词 DIAGNOSIS Blood-borne viruses multiplex polymerase chain reaction High-resolution melting
下载PDF
Multiplexer Design Applied to High-Speed Signal Transmission 被引量:2
12
作者 曹寒梅 杨银堂 +2 位作者 蔡伟 陆铁军 王宗民 《Journal of Semiconductors》 EI CAS CSCD 北大核心 2008年第6期1040-1043,共4页
A multiplexer with a low-distortion high-bandwidth analog switch is presented. The gate-to-source voltage of the switch is set by the combined on-voltage of a pMOS and an nMOS,and the difference between its gate-sourc... A multiplexer with a low-distortion high-bandwidth analog switch is presented. The gate-to-source voltage of the switch is set by the combined on-voltage of a pMOS and an nMOS,and the difference between its gate-source voltage and the threshold voltage (VGST) is guaranteed to be constant with input variation. Thus, the body effect is nearly canceled. Implemented in a TSMC 0.18μm CMOS process, results from HSPICE simulation show that the VGST is nearly constant with an input range from 0.3 to 1.7V,and the - 3dB bandwidth is larger than 10GHz;the SFDR (spurious free dynamic range) of the output is 67. lldB with 1GHz input frequency; the turn-on time is 2.98ns,and the turn-off time is 1.35ns, which indicates a break-before-make action of the multiplexer. The proposed structure can be applied to high speed signal transmission. 展开更多
关键词 low-distortion high speed multiplexer analog switch
下载PDF
A 32-channel 100 GHz wavelength division multiplexer by interleaving two silicon arrayed waveguide gratings 被引量:2
13
作者 Changjian Xie Xihua Zou +3 位作者 Fang Zou Lianshan Yan Wei Pan Yong Zhang 《Chinese Physics B》 SCIE EI CAS CSCD 2021年第12期339-342,共4页
A 32-channel wavelength division multiplexer with 100 GHz spacing is designed and fabricated by interleaving two silicon arrayed waveguide gratings(AWGs).It has a parallel structure consisting of two silicon 16-channe... A 32-channel wavelength division multiplexer with 100 GHz spacing is designed and fabricated by interleaving two silicon arrayed waveguide gratings(AWGs).It has a parallel structure consisting of two silicon 16-channel AWGs with200 GHz spacing and a Mach-Zehnder interferometer(MZI)with 200 GHz free spectral range.The 16 channels of one silicon AWG are interleaved with those of the other AWG in spectrum,but with an identical spacing of 200 GHz.For the composed wavelength division multiplexer,the experiment results reveal 32 wavelength channels in C-band,a wavelength spacing of 100 GHz,and a channel crosstalk lower than-15 dB. 展开更多
关键词 wavelength division multiplexer arrayed waveguide grating silicon photonics Mach-Zehnder interferometer
下载PDF
Design and Analysis of 4×4 Arrayed Waveguide Grating Multiplexer 被引量:1
14
作者 DINGYao-ming ZHANGGuo-ping 《Semiconductor Photonics and Technology》 CAS 2002年第2期65-69,79,共6页
The operation principle of an arrayed waveguide grating(AWG) multiplexer is introduced and the 4×4 AWG with following design parameters is discussed in detail, such as the choice of wavelength, the neighboring ar... The operation principle of an arrayed waveguide grating(AWG) multiplexer is introduced and the 4×4 AWG with following design parameters is discussed in detail, such as the choice of wavelength, the neighboring arrayed waveguide distance ΔL, the channel frequency interval Δf, and the free spectral range. The structure of 4×4 AWG is designed and the result of stimulated test is also given. Analysis shows that the 4×4 AWG is characterized by a wide dynamic range, low crosstalk, better spectrum properties, and a compact structure. 展开更多
关键词 Arrayed waveguide grating Wavelength multiplex DESIGN
下载PDF
Flat multifunctional liquid crystal elements through multi-dimensional information multiplexing 被引量:10
15
作者 Dongliang Tang Zhenglong Shao +4 位作者 Xin Xie Yingjie Zhou Xiaohu Zhang Fan Fan Shuangchun Wen 《Opto-Electronic Advances》 SCIE EI CAS CSCD 2023年第4期39-47,共9页
Flat optical elements have attracted enormous attentions and act as promising candidates for the next generation of optical components.As one of the most outstanding representatives,liquid crystal(LC)has been widely a... Flat optical elements have attracted enormous attentions and act as promising candidates for the next generation of optical components.As one of the most outstanding representatives,liquid crystal(LC)has been widely applied in flat panel display industries and inspires the wavefront modulation with the development of LC alignment techniques.However,most LC elements perform only one type of optical manipulation and are difficult to realize the multifunctionality and light integration.Here,flat multifunctional liquid crystal elements(FMLCEs),merely composed of anisotropic LC molecules with space-variant orientations,are presented for multichannel information manipulation by means of polarization,space and wavelength multiplexing.Specifically,benefiting from the unique light response with the change of the incident polarization,observation plane,and working wavelength,a series of FMLCEs are demonstrated to achieve distinct near-and far-field display functions.The proposed strategy takes full advantage of basic optical parameters as the decrypted keys to improve the information capacity and security,and we expect it to find potential applications in information encryption,optical anti-counterfeiting,virtual/augmented reality,etc. 展开更多
关键词 MULTIFUNCTIONAL liquid crystal HOLOGRAPHY information multiplexing
下载PDF
Determination of Transmission Routing of OXC Nodes Based on AWG Multiplexer by Matrix Transformation 被引量:1
16
作者 GUOAi-huang FUJun-mei 《Semiconductor Photonics and Technology》 CAS 2004年第1期1-4,7,共5页
The structures of the space switching and the wavelength switching optical cross connect (OXC) nodes which are based on the arrayed waveguide grating (AWG) multiplexer are analyzed.By the matrix transformation relatio... The structures of the space switching and the wavelength switching optical cross connect (OXC) nodes which are based on the arrayed waveguide grating (AWG) multiplexer are analyzed.By the matrix transformation relation between the input and output wavelengths of the AWG multiplexer, the wavelength transmission routings of the space switching and wavelength switching OXC nodes are determined. 展开更多
关键词 AWG multiplexer OXC nodes Matrix transformation Wavelength transmission routing
下载PDF
Time-sequential color code division multiplexing holographic display with metasurface 被引量:9
17
作者 Xin Li Qinmiao Chen +4 位作者 Xue Zhang Ruizhe Zhao Shumin Xiao Yongtian Wang Lingling Huang 《Opto-Electronic Advances》 SCIE EI CAS CSCD 2023年第8期8-16,共9页
Color metasurface holograms are powerful and versatile platforms for modulating the amplitude,phase,polarization,and other properties of light at multiple operating wavelengths.However,the current color metasurface ho... Color metasurface holograms are powerful and versatile platforms for modulating the amplitude,phase,polarization,and other properties of light at multiple operating wavelengths.However,the current color metasurface holography can only realize static manipulation.In this study,we propose and demonstrate a multiplexing metasurface technique combined with multiwavelength code-division multiplexing(CDM)to realize dynamic manipulation.Multicolor code references are utilized to record information within a single metasurface and increase the information capacity and security for anticracks.A total of 48 monochrome images consisting of pure color characters and multilevel color video frames were reconstructed in dual polarization channels of the birefringent metasurface to exhibit high information density,and a video was displayed via sequential illumination of the corresponding code patterns to verify the ability of dynamic manipulation.Our approach demonstrates significant application potential in optical data storage,optical encryption,multiwavelengthversatile diffractive optical elements,and stimulated emission depletion microscopy. 展开更多
关键词 metasurface color holography dynamic display code division multiplexing
下载PDF
Planar peristrophic multiplexing metasurfaces 被引量:4
18
作者 Jia Chen Dapeng Wang +3 位作者 Guangyuan Si Siew Lang Teo Qian Wang Jiao Lin 《Opto-Electronic Advances》 SCIE EI CAS CSCD 2023年第8期40-48,共9页
As a promising counterpart of two-dimensional metamaterials,metasurfaces enable to arbitrarily control the wavefront of light at subwavelength scale and hold promise for planar holography and applicable multiplexing d... As a promising counterpart of two-dimensional metamaterials,metasurfaces enable to arbitrarily control the wavefront of light at subwavelength scale and hold promise for planar holography and applicable multiplexing devices.Nevertheless,the degrees of freedom(DoF)to orthogonally multiplex data have been almost exhausted.Compared with state-of-theart methods that extensively employ the orthogonal basis such as wavelength,polarization or orbital angular momentum,we propose an unprecedented method of peristrophic multiplexing by combining the spatial frequency orthogonality with the subwavelength detour phase principle.The orthogonal relationship between the spatial frequency of incident light and the locally shifted building blocks of metasurfaces can be regarded as an additional DoF.We experimentally demonstrate the viability of the multiplexed holograms.Moreover,this newly-explored orthogonality is compatible with conventional DoFs.Our findings will contribute to the development of multiplexing metasurfaces and provide a novel solution to nanophotonics,such as large-capacity chip-scale devices and highly integrated communication. 展开更多
关键词 peristrophic multiplexing metasurface HOLOGRAPHY
下载PDF
基于AL37219 Multiplexer的多功能视频分割器的设计
19
作者 谢可杨 李兵 《工业仪表与自动化装置》 2006年第6期50-52,共3页
监视系统是楼宇安防、电视指挥中心等场合重要的设备,该文采用8051单片机操作系统,基于视频复用芯片AL37219和解码芯片AL240的组合使用,设计了一种新的视频分割器,用于监视系统的前端处理,可在一套主监视系统下实现画面帧测和画面分割... 监视系统是楼宇安防、电视指挥中心等场合重要的设备,该文采用8051单片机操作系统,基于视频复用芯片AL37219和解码芯片AL240的组合使用,设计了一种新的视频分割器,用于监视系统的前端处理,可在一套主监视系统下实现画面帧测和画面分割显示的作用。 展开更多
关键词 解码 动态帧测 画面分割
下载PDF
DELAY JITTER OF A PERIODIC CELL STREAM THROUGH AN ATM MULTIPLEXER IN A BURSTY TRAFFIC ENVIRONMENT
20
作者 He Jiafu Li Lemin(University of Electronic Science and Technology of China, Chengdu 610054) 《Journal of Electronics(China)》 1997年第4期318-327,共10页
The periodic cell stream is a very important member among the input traffic sources in ATM networks. In this paper, a finite-buffered ATM multiplexer with traffic sources composed of a periodic cell stream, multiple i... The periodic cell stream is a very important member among the input traffic sources in ATM networks. In this paper, a finite-buffered ATM multiplexer with traffic sources composed of a periodic cell stream, multiple i.i.d Bernoulli cell streams and bursty two-state Markov Modulated Bernoulli Process (MMBP) cell streams is exactly analyzed. The probability mass function of queuing delay, the autocorrelation and power spectrum of delay jitter for this periodic cell stream are derived. The analysis is used to expose the behavior of delay jitter for a periodic cell stream through an ATM multiplexer in a bursty traffic environment. The simulation results indicate that the analytical results are accurate. 展开更多
关键词 ATM multiplexer PERIODIC CELL STREAM Bursty traffic Delay JITTER
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部