We study the quantum fluctuations of the charge and current of two L-C dissipative mesoscopic circuit with the mutual inductance in the vacuum state.Our results show that the system state will evolve to a squeezed coh...We study the quantum fluctuations of the charge and current of two L-C dissipative mesoscopic circuit with the mutual inductance in the vacuum state.Our results show that the system state will evolve to a squeezed coherent state under the effect of external source.We find that the squeezing amplitude parameter is relative to the parameters of circuit and the mutual-inductance coefficient in the existence of dissipation.When the circuit has no dissipation or there is complete coupling between two meshes,the squeezing amplitude parameter only depends on the capacitance's ratio.展开更多
An algorithm for precisely calculating the inductance of a three-section solenoid is presented, which is based on summing the layer self-inductances and the mutual inductances. A theoretical model with ex plicit expre...An algorithm for precisely calculating the inductance of a three-section solenoid is presented, which is based on summing the layer self-inductances and the mutual inductances. A theoretical model with ex plicit expressions is firstly developed to calculate the self-inductance of a single layer, and then numerical calcu lation of the mutual inductance between two layers is introduced. Using the presented computation method, the inductance of a solenoid designed in the experiment is successfully calculated (4.30 mH), which has a difference of less than 1% from the experimental data.展开更多
Live line measurement methods can reduce the loss of power outages and eliminate interference. There are three live line measurement methods including integral method, differential method and algebraic method. A simul...Live line measurement methods can reduce the loss of power outages and eliminate interference. There are three live line measurement methods including integral method, differential method and algebraic method. A simulation model of?two coupled parallel transmission lines spanning on the same towers is built in PSCAD and the calculation errors of these three methods are compared with different sampling frequencies by using of Matlab. The effect of harmonic on calculation is also involved. The simulation results indicate that harmonic has the least effect on the algebraic method which provides stable result and small error.展开更多
A live line measurement method for the zero sequence parameters of transmission lines with mutual inductance is introduced. The mathematical models of the measurement method are given. Global Positioning System (GPS) ...A live line measurement method for the zero sequence parameters of transmission lines with mutual inductance is introduced. The mathematical models of the measurement method are given. Global Positioning System (GPS) is used as the synchronous signal for the measurement carried out at different substations simultaneously. The measurement system and digital simulation results are given. Finally, the live line measurement results of two 220 kV transmission lines with mutual inductance in Hainangrid are given. Results from both simulation and on-site measurement show that the live line measurement method is feasible, and its measurement accuracy can satisfactorily meet the requirements of engineering measurement.展开更多
文摘We study the quantum fluctuations of the charge and current of two L-C dissipative mesoscopic circuit with the mutual inductance in the vacuum state.Our results show that the system state will evolve to a squeezed coherent state under the effect of external source.We find that the squeezing amplitude parameter is relative to the parameters of circuit and the mutual-inductance coefficient in the existence of dissipation.When the circuit has no dissipation or there is complete coupling between two meshes,the squeezing amplitude parameter only depends on the capacitance's ratio.
文摘An algorithm for precisely calculating the inductance of a three-section solenoid is presented, which is based on summing the layer self-inductances and the mutual inductances. A theoretical model with ex plicit expressions is firstly developed to calculate the self-inductance of a single layer, and then numerical calcu lation of the mutual inductance between two layers is introduced. Using the presented computation method, the inductance of a solenoid designed in the experiment is successfully calculated (4.30 mH), which has a difference of less than 1% from the experimental data.
文摘Live line measurement methods can reduce the loss of power outages and eliminate interference. There are three live line measurement methods including integral method, differential method and algebraic method. A simulation model of?two coupled parallel transmission lines spanning on the same towers is built in PSCAD and the calculation errors of these three methods are compared with different sampling frequencies by using of Matlab. The effect of harmonic on calculation is also involved. The simulation results indicate that harmonic has the least effect on the algebraic method which provides stable result and small error.
文摘A live line measurement method for the zero sequence parameters of transmission lines with mutual inductance is introduced. The mathematical models of the measurement method are given. Global Positioning System (GPS) is used as the synchronous signal for the measurement carried out at different substations simultaneously. The measurement system and digital simulation results are given. Finally, the live line measurement results of two 220 kV transmission lines with mutual inductance in Hainangrid are given. Results from both simulation and on-site measurement show that the live line measurement method is feasible, and its measurement accuracy can satisfactorily meet the requirements of engineering measurement.