The authors propose a novel method for transporting multi-view videos that aims to keep the bandwidth requirements on both end-users and servers as low as possible. The method is based on application layer multicast, ...The authors propose a novel method for transporting multi-view videos that aims to keep the bandwidth requirements on both end-users and servers as low as possible. The method is based on application layer multicast, where each end point re- ceives only a selected number of views required for rendering video from its current viewpoint at any given time. The set of selected videos changes in real time as the user’s viewpoint changes because of head or eye movements. Techniques for reducing the black-outs during fast viewpoint changes were investigated. The performance of the approach was studied through network experiments.展开更多
This paper analyzes the technical characteristic of three-dimensional display technology (3DTV) system and some core technologies yet to be solved. It points out the ways to solve these problems and presents an effe...This paper analyzes the technical characteristic of three-dimensional display technology (3DTV) system and some core technologies yet to be solved. It points out the ways to solve these problems and presents an effective solution for thediscomfort of watching the three-dimensional TV.展开更多
Mastering quality of experience (QoE) is key to the widespread adoption of stereoscopic 3DTV (S-3DTV). However, assessing QoE of S-3DTV is not straightforward. Methods for determining observer experience need to b...Mastering quality of experience (QoE) is key to the widespread adoption of stereoscopic 3DTV (S-3DTV). However, assessing QoE of S-3DTV is not straightforward. Methods for determining observer experience need to be clearly defined and sufficiently robust. In this paper, we present state-of-the-art subjective QoE assessment for S-3DTV. We present conventional stan- dardized ITU recommendations for evaluating picture quality and discuss new ITU activities in the area of S-3DTV assess- ment. We also present and discuss explorative studies from the literature. We then introduce ways of using conventional quality assessment for S-3DTV QoE assessment. In discussing our pro- posal, we mainly focus on QoE indicators and common features of subjective assessment. Multidimensional QoE indicators need to be used in S-3DTV to highlight advantages and reveal problems. In the second part of our proposal, we discuss the re- quirements for adapting ITU-R BT.500, a conventional subjec- tive QoE assessment method, ITU-R BT.500, for assessing QoE of S-3DTV are presented.展开更多
A novel ZnII-based metal-organic framework with the formula of{[Zn_(2)(BBIP)_(2)(NDC)_(2)]·H_(2)O}n(JXUST-5)derived from 3,5-bis(benzimidazol-1-yl)pyridine(BBIP)and 1,4-naphthalenedicarboxylic acid(H_(2)NDC)has b...A novel ZnII-based metal-organic framework with the formula of{[Zn_(2)(BBIP)_(2)(NDC)_(2)]·H_(2)O}n(JXUST-5)derived from 3,5-bis(benzimidazol-1-yl)pyridine(BBIP)and 1,4-naphthalenedicarboxylic acid(H_(2)NDC)has been synthesized.The adjacent Zn^(II)ions are linked through two BBIP ligands to form a[Zn_(2)(BBIP)_(2)]secondary building unit(SBU).The neighbouring SBUs are further connected by NDC^(2-)withμ2-η^(1):η^(1)andμ2-η^(1):η^(1):η^(1)bridging modes to form a two-dimensional(2D)framework.Topological analysis shows that JXUST-5 could be simplified as an uninodal fes topology with a point symbol of{4.8^(2)}.Furthermore,the 2D framework net could be extended through C-H···πinteraction to form the three-dimensional supramolecular structure.Luminescent experiments suggest that JXUST-5 could selectively and sensitively recognize Al^(3+)and Ga^(3+)through fluorescence enhancement effect along with a relatively large red shift.The detection limits for Al^(3+)and Ga^(3+)are 0.17 and 0.69 ppm,respectively.Interestingly,the sensing process for both Al^(3+)and Ga^(3+)could be directly observed with naked eyes under 365 nm UV lamp.Notably,JXUST-5 could be recycled at least five times as a fluorescent sensor toward Al^(3+)and Ga^(3+),which is the second example of turn-on MOF based fluorescent sensor toward Ga^(3+).展开更多
基金Project (No. 511568) supported by the European Commissionwithin Framework Program 6 with the acronym 3DTV
文摘The authors propose a novel method for transporting multi-view videos that aims to keep the bandwidth requirements on both end-users and servers as low as possible. The method is based on application layer multicast, where each end point re- ceives only a selected number of views required for rendering video from its current viewpoint at any given time. The set of selected videos changes in real time as the user’s viewpoint changes because of head or eye movements. Techniques for reducing the black-outs during fast viewpoint changes were investigated. The performance of the approach was studied through network experiments.
基金supported by the National Natural Science Foundation of China(Grant No.60832003)the Science and Technology Commission of Shanghai Municipality(Grant No.10510500500)the Key Laboratory of Advanced Display and System Applications(Shanghai University),Ministry of Education,China(Grant No.P200801)
文摘This paper analyzes the technical characteristic of three-dimensional display technology (3DTV) system and some core technologies yet to be solved. It points out the ways to solve these problems and presents an effective solution for thediscomfort of watching the three-dimensional TV.
文摘Mastering quality of experience (QoE) is key to the widespread adoption of stereoscopic 3DTV (S-3DTV). However, assessing QoE of S-3DTV is not straightforward. Methods for determining observer experience need to be clearly defined and sufficiently robust. In this paper, we present state-of-the-art subjective QoE assessment for S-3DTV. We present conventional stan- dardized ITU recommendations for evaluating picture quality and discuss new ITU activities in the area of S-3DTV assess- ment. We also present and discuss explorative studies from the literature. We then introduce ways of using conventional quality assessment for S-3DTV QoE assessment. In discussing our pro- posal, we mainly focus on QoE indicators and common features of subjective assessment. Multidimensional QoE indicators need to be used in S-3DTV to highlight advantages and reveal problems. In the second part of our proposal, we discuss the re- quirements for adapting ITU-R BT.500, a conventional subjec- tive QoE assessment method, ITU-R BT.500, for assessing QoE of S-3DTV are presented.
基金supported from the National Natural Science Foundation of China(Nos.22061019,21761012 and 21861018)the Natural Science Foundation of Jiangxi Province(Nos.20192BAB203001,20202ACBL213001,20192ACBL20013 and 20182BCB22010)+1 种基金the Youth Jinggang Scholars Program in Jiangxi Province(No.QNJG2019053)the Two Thousand Talents Program in Jiangxi Province(No.jxsq2019201068)。
文摘A novel ZnII-based metal-organic framework with the formula of{[Zn_(2)(BBIP)_(2)(NDC)_(2)]·H_(2)O}n(JXUST-5)derived from 3,5-bis(benzimidazol-1-yl)pyridine(BBIP)and 1,4-naphthalenedicarboxylic acid(H_(2)NDC)has been synthesized.The adjacent Zn^(II)ions are linked through two BBIP ligands to form a[Zn_(2)(BBIP)_(2)]secondary building unit(SBU).The neighbouring SBUs are further connected by NDC^(2-)withμ2-η^(1):η^(1)andμ2-η^(1):η^(1):η^(1)bridging modes to form a two-dimensional(2D)framework.Topological analysis shows that JXUST-5 could be simplified as an uninodal fes topology with a point symbol of{4.8^(2)}.Furthermore,the 2D framework net could be extended through C-H···πinteraction to form the three-dimensional supramolecular structure.Luminescent experiments suggest that JXUST-5 could selectively and sensitively recognize Al^(3+)and Ga^(3+)through fluorescence enhancement effect along with a relatively large red shift.The detection limits for Al^(3+)and Ga^(3+)are 0.17 and 0.69 ppm,respectively.Interestingly,the sensing process for both Al^(3+)and Ga^(3+)could be directly observed with naked eyes under 365 nm UV lamp.Notably,JXUST-5 could be recycled at least five times as a fluorescent sensor toward Al^(3+)and Ga^(3+),which is the second example of turn-on MOF based fluorescent sensor toward Ga^(3+).