With the wide application of laser in the field of skin plastic surgery, micro laser galvanometer scanner has made great progress in this field with its portability. However, the measurement method used to measure the...With the wide application of laser in the field of skin plastic surgery, micro laser galvanometer scanner has made great progress in this field with its portability. However, the measurement method used to measure the deflection angle of laser galvanometer in the narrow space of scanner with high precision remains to be studied. In this paper, an angle measurement method based on magnetic field is proposed, and the effect of the shapes of permanent magnets(PMs) on the measurement is studied by theoretical and experimental study under the condition that the maximum available space for the PMs is a 10 mm side cube. An angle measuring experimental device is set up, and the contrast experiment is carried out with different PMs which are the same as simulation. The experimental results show that cylindrical PM is more suitable than other PMs, which is consistent with the simulation results, and the maximum nonlinearity error is 0.562%. This method has the advantages of small volume,non-contact measurement, small moment of inertia, good dynamic response and no external excitation for the PMs, so it has a broad application prospect in micro laser galvanometer scanner.展开更多
In this study, we tried to improve the performance by giving a pre-swirling flow to the radial inflow that occurred in the semi-opened axial fan. In addition, the flow fields of rotor outlet were clarified experimenta...In this study, we tried to improve the performance by giving a pre-swirling flow to the radial inflow that occurred in the semi-opened axial fan. In addition, the flow fields of rotor outlet were clarified experimentally, and the effect of pre-swirling flow was considered. The experiment was carried out using a performance test wind tunnel with a square cross section of 880 mm. Three types of casings were prepared, in which the blade tip protruded 0%, 20%, and 40% of the meridional chord length. They were called R25, R15, and R05, respectively, in the casing bellmouth model code. Guide blades for generating a pre-swirling flow were installed on the vertical wall surface of the casing. In addition, a vertical wall was installed 60% upstream of the meridional chord length as an obstacle to prevent axial inflow. The velocity fields of the rotor outlet were measured using a hot-wire anemometer. From the results, the pre-swirling flow did not significantly affect the fan performance. When there was no obstacles wall upstream, there was a partial increase in efficiency, but the difference was not so large. When there was an obstacle wall upstream, the efficiency increased overall in the case of R15, but in the case of R05, the efficiency increased only in the low flow rate region, and conversely decreased in the high flow rate region. By observing the blade outlet flow fields when the performance was improved, it was confirmed that the influence of the tip leakage vortex was weakened.展开更多
Background: Rheumatoid arthritis is a form of autoimmune disease characterized by synovitis that can ultimately cause joint deformities and impaired functioning. The cartilage destruction is one of the most important ...Background: Rheumatoid arthritis is a form of autoimmune disease characterized by synovitis that can ultimately cause joint deformities and impaired functioning. The cartilage destruction is one of the most important indicators for diagnosis and treatment of rheumatoid arthritis, and it is radiographically manifested as joint space narrowing. Issue: In the literature, the joint space narrowing progression between a baseline and its follow-up finger joint images can be quantified by using image registration algorithm. We found that the inconsistencies of joint angles may lead to characteristic mismatches and thus severely affect the accuracy of joint space narrowing quantifications. Methods: In this work, we introduce a rotation invariant phase only correlation in joint space narrowing quantification for the joint angle correction. Further, we propose a confidence index to quantify the quantification reliability of phase only correlation based on phase dispersion in phase difference spectrum. Conclusion: In our clinical experiments, the proposed quantification method can effectively overcome and manage the mismatch due to the inconsistency of joint angles. Additionally, the confidence index shows a high consistency with the joint space narrowing progression examinations manually done by a trained radiologist and one radiological technologist.展开更多
A single-/dual-wavelength switchable and tunable erbium-doped fiber laser(EDFL) with super-narrow linewidth has been proposed and experimentally demonstrated at room temperature. The fiber laser is based on a compound...A single-/dual-wavelength switchable and tunable erbium-doped fiber laser(EDFL) with super-narrow linewidth has been proposed and experimentally demonstrated at room temperature. The fiber laser is based on a compound cavity simply composed of a ring main cavity and a two-ring subring cavity(TR-SC). Regardless of single- or dual-wavelength operation, the EDFL could always work well in single-longitudinal-mode(SLM) state at every oscillating wavelength. In dual-wavelength operation, the spacing could be tuned from 0 nm to 4.83 nm. In single-wavelength operation, the EDFL could lase at a fixed wavelength of 1 543.65 nm or another wavelength with a tunable range of 4.83 nm. The super-narrow linewidths of 550 Hz and 600 Hz for two wavelengths are obtained. The proposed EDFL has potential applications in microwave/terahertz-wave generation and high-precision distributed fiber optical sensing.展开更多
High intensity resistance training(HI-RT)is a treatment option for Knee Osteoarthritis(KOA).Isotonic machines(leg press,leg extension)are utilized for standardization and reproducibility reasons,but the load used duri...High intensity resistance training(HI-RT)is a treatment option for Knee Osteoarthritis(KOA).Isotonic machines(leg press,leg extension)are utilized for standardization and reproducibility reasons,but the load used during the protocol is often low,considering that elder people usually have low strength levels,training so with high in-tensities calculated on low loads.The physiological response of an elder woman trained with high loads on a free weight exercise,the regular barbell deadlift,with a 1 Repetition Maximum(1RM)of 100 kg,can be appreciated in this report,so that for the first time we can see the effect of a one year of high intensity resistance training program on a powerlifting exercise on a 72 year-old woman with KOA.A Western Ontario and McMaster Uni-versities Arthritis Index(WOMAC)questionnaire was administered before starting the training program(T0)and after 1 year of training,as long as a control RX,to evaluate the effect of HI-RT on joint functionality and quality of life.展开更多
基金supported by the Aeronautical Science Foundation of China [grant numbers 20175748009]。
文摘With the wide application of laser in the field of skin plastic surgery, micro laser galvanometer scanner has made great progress in this field with its portability. However, the measurement method used to measure the deflection angle of laser galvanometer in the narrow space of scanner with high precision remains to be studied. In this paper, an angle measurement method based on magnetic field is proposed, and the effect of the shapes of permanent magnets(PMs) on the measurement is studied by theoretical and experimental study under the condition that the maximum available space for the PMs is a 10 mm side cube. An angle measuring experimental device is set up, and the contrast experiment is carried out with different PMs which are the same as simulation. The experimental results show that cylindrical PM is more suitable than other PMs, which is consistent with the simulation results, and the maximum nonlinearity error is 0.562%. This method has the advantages of small volume,non-contact measurement, small moment of inertia, good dynamic response and no external excitation for the PMs, so it has a broad application prospect in micro laser galvanometer scanner.
文摘In this study, we tried to improve the performance by giving a pre-swirling flow to the radial inflow that occurred in the semi-opened axial fan. In addition, the flow fields of rotor outlet were clarified experimentally, and the effect of pre-swirling flow was considered. The experiment was carried out using a performance test wind tunnel with a square cross section of 880 mm. Three types of casings were prepared, in which the blade tip protruded 0%, 20%, and 40% of the meridional chord length. They were called R25, R15, and R05, respectively, in the casing bellmouth model code. Guide blades for generating a pre-swirling flow were installed on the vertical wall surface of the casing. In addition, a vertical wall was installed 60% upstream of the meridional chord length as an obstacle to prevent axial inflow. The velocity fields of the rotor outlet were measured using a hot-wire anemometer. From the results, the pre-swirling flow did not significantly affect the fan performance. When there was no obstacles wall upstream, there was a partial increase in efficiency, but the difference was not so large. When there was an obstacle wall upstream, the efficiency increased overall in the case of R15, but in the case of R05, the efficiency increased only in the low flow rate region, and conversely decreased in the high flow rate region. By observing the blade outlet flow fields when the performance was improved, it was confirmed that the influence of the tip leakage vortex was weakened.
文摘Background: Rheumatoid arthritis is a form of autoimmune disease characterized by synovitis that can ultimately cause joint deformities and impaired functioning. The cartilage destruction is one of the most important indicators for diagnosis and treatment of rheumatoid arthritis, and it is radiographically manifested as joint space narrowing. Issue: In the literature, the joint space narrowing progression between a baseline and its follow-up finger joint images can be quantified by using image registration algorithm. We found that the inconsistencies of joint angles may lead to characteristic mismatches and thus severely affect the accuracy of joint space narrowing quantifications. Methods: In this work, we introduce a rotation invariant phase only correlation in joint space narrowing quantification for the joint angle correction. Further, we propose a confidence index to quantify the quantification reliability of phase only correlation based on phase dispersion in phase difference spectrum. Conclusion: In our clinical experiments, the proposed quantification method can effectively overcome and manage the mismatch due to the inconsistency of joint angles. Additionally, the confidence index shows a high consistency with the joint space narrowing progression examinations manually done by a trained radiologist and one radiological technologist.
基金supported by the Youth Foundation of Hebei Educational Committee(No.QN2015235)the Technology Foundation for Selected Overseas Chinese Scholar of Ministry of Human Resources and Social Security of China(No.CG2015003006)the Special Funding of Comprehensive Capability Enhancement Program from Hebei University
文摘A single-/dual-wavelength switchable and tunable erbium-doped fiber laser(EDFL) with super-narrow linewidth has been proposed and experimentally demonstrated at room temperature. The fiber laser is based on a compound cavity simply composed of a ring main cavity and a two-ring subring cavity(TR-SC). Regardless of single- or dual-wavelength operation, the EDFL could always work well in single-longitudinal-mode(SLM) state at every oscillating wavelength. In dual-wavelength operation, the spacing could be tuned from 0 nm to 4.83 nm. In single-wavelength operation, the EDFL could lase at a fixed wavelength of 1 543.65 nm or another wavelength with a tunable range of 4.83 nm. The super-narrow linewidths of 550 Hz and 600 Hz for two wavelengths are obtained. The proposed EDFL has potential applications in microwave/terahertz-wave generation and high-precision distributed fiber optical sensing.
文摘High intensity resistance training(HI-RT)is a treatment option for Knee Osteoarthritis(KOA).Isotonic machines(leg press,leg extension)are utilized for standardization and reproducibility reasons,but the load used during the protocol is often low,considering that elder people usually have low strength levels,training so with high in-tensities calculated on low loads.The physiological response of an elder woman trained with high loads on a free weight exercise,the regular barbell deadlift,with a 1 Repetition Maximum(1RM)of 100 kg,can be appreciated in this report,so that for the first time we can see the effect of a one year of high intensity resistance training program on a powerlifting exercise on a 72 year-old woman with KOA.A Western Ontario and McMaster Uni-versities Arthritis Index(WOMAC)questionnaire was administered before starting the training program(T0)and after 1 year of training,as long as a control RX,to evaluate the effect of HI-RT on joint functionality and quality of life.