Objective This study aimed to compare the performance of standard-definition white-light endoscopy(SD-WL),high-definition white-light endoscopy(HD-WL),and high-definition narrow-band imaging(HD-NBI)in detecting colore...Objective This study aimed to compare the performance of standard-definition white-light endoscopy(SD-WL),high-definition white-light endoscopy(HD-WL),and high-definition narrow-band imaging(HD-NBI)in detecting colorectal lesions in the Chinese population.Methods This was a multicenter,single-blind,randomized,controlled trial with a non-inferiority design.Patients undergoing endoscopy for physical examination,screening,and surveillance were enrolled from July 2017 to December 2020.The primary outcome measure was the adenoma detection rate(ADR),defined as the proportion of patients with at least one adenoma detected.The associated factors for detecting adenomas were assessed using univariate and multivariate logistic regression.Results Out of 653 eligible patients enrolled,data from 596 patients were analyzed.The ADRs were 34.5%in the SD-WL group,33.5%in the HD-WL group,and 37.5%in the HD-NBI group(P=0.72).The advanced neoplasm detection rates(ANDRs)in the three arms were 17.1%,15.5%,and 10.4%(P=0.17).No significant differences were found between the SD group and HD group regarding ADR or ANDR(ADR:34.5%vs.35.6%,P=0.79;ANDR:17.1%vs.13.0%,P=0.16,respectively).Similar results were observed between the HD-WL group and HD-NBI group(ADR:33.5%vs.37.7%,P=0.45;ANDR:15.5%vs.10.4%,P=0.18,respectively).In the univariate and multivariate logistic regression analyses,neither HD-WL nor HD-NBI led to a significant difference in overall adenoma detection compared to SD-WL(HD-WL:OR 0.91,P=0.69;HD-NBI:OR 1.15,P=0.80).Conclusion HD-NBI and HD-WL are comparable to SD-WL for overall adenoma detection among Chinese outpatients.It can be concluded that HD-NBI or HD-WL is not superior to SD-WL,but more effective instruction may be needed to guide the selection of different endoscopic methods in the future.Our study’s conclusions may aid in the efficient allocation and utilization of limited colonoscopy resources,especially advanced imaging technologies.展开更多
BACKGROUND Conventional magnifying endoscopy with narrow-band imaging(NBI)observation of the gastric body mucosa shows dominant patterns in relation to the regular arrangement of collecting venules,subepithelial capil...BACKGROUND Conventional magnifying endoscopy with narrow-band imaging(NBI)observation of the gastric body mucosa shows dominant patterns in relation to the regular arrangement of collecting venules,subepithelial capillary network,and gastric pits.AIM To evaluate the effectiveness of a new one-dual(near)focus,NBI mode in the assessment of the microscopic features of gastric body mucosa compared to conventional magnification.METHODS During 2021 and 2022,68 patients underwent proximal gastrointestinal endoscopy using magnification endoscopic modalities subsequently applying acetic acid(AA).The GIF-190HQ series NBI system with dual focus capability was used for the investigation of gastric mucosa.At the time of the endoscopy,the gastric body mucosa of all enrolled patients was photographed using the white light endoscopy(WLE),near focus(NF),NF-NBI,AA-NF,and AA-NF-NBI modes.RESULTS The WLE,NF and NF-NBI endoscopic modes for all patients(204 images)were classified in the same order into three groups.Two images from each patient for the AA-NF and AA-NF-NBI endoscopic modes were classified in the same order.According to all three observers who completed the work independently,NF magnification was significantly superior to WLE(P<0.01),and the NF-NBI mode was significantly superior to NF magnification(P<0.01).After applying AA,the three observers confirmed that AA-NF-NBI was significantly superior to AA-NF(P<0.01).Interobserver kappa values for WLE were 0.609,0.704,and 0.598,respectively and were 0.600,0.721,and 0.637,respectively,for NF magnification.For the NF-NBI mode,the values were 0.378,0.471,and 0.553,respectively.For AA-NF,they were 0.453,0.603,and 0.480,respectively,and for AA-NF-NBI,they were 0.643,0.506,and 0.354,respectively.CONCLUSION When investigating gastric mucosa in microscopic detail,NF-NBI was the most powerful endoscopic mode for assessing regular arrangement of collecting venules,subepithelial capillary network,and gastric pits among the five endoscopic modalities investigated in this study.AA-NF-NBI was the most powerful endoscopic mode for analyzing crypt opening and intervening part.展开更多
This editorial summarizes the latest literature on the roles of neuronal PAS domain protein 2 and KN motif/ankyrin repeat domain 1 in type 2 diabetes(T2D).We highlight their involvement inβ-cell dysfunction,explore t...This editorial summarizes the latest literature on the roles of neuronal PAS domain protein 2 and KN motif/ankyrin repeat domain 1 in type 2 diabetes(T2D).We highlight their involvement inβ-cell dysfunction,explore their potential as therapeutic targets,and discuss the implications for new treatment strategies.We offer valuable insights into relevant gene regulation and cellular mechanisms relevant for the targeted management of T2D.展开更多
基金supported by the Beijing Municipal Science and Technology Commission(BMSTC,No.D171100002617001).
文摘Objective This study aimed to compare the performance of standard-definition white-light endoscopy(SD-WL),high-definition white-light endoscopy(HD-WL),and high-definition narrow-band imaging(HD-NBI)in detecting colorectal lesions in the Chinese population.Methods This was a multicenter,single-blind,randomized,controlled trial with a non-inferiority design.Patients undergoing endoscopy for physical examination,screening,and surveillance were enrolled from July 2017 to December 2020.The primary outcome measure was the adenoma detection rate(ADR),defined as the proportion of patients with at least one adenoma detected.The associated factors for detecting adenomas were assessed using univariate and multivariate logistic regression.Results Out of 653 eligible patients enrolled,data from 596 patients were analyzed.The ADRs were 34.5%in the SD-WL group,33.5%in the HD-WL group,and 37.5%in the HD-NBI group(P=0.72).The advanced neoplasm detection rates(ANDRs)in the three arms were 17.1%,15.5%,and 10.4%(P=0.17).No significant differences were found between the SD group and HD group regarding ADR or ANDR(ADR:34.5%vs.35.6%,P=0.79;ANDR:17.1%vs.13.0%,P=0.16,respectively).Similar results were observed between the HD-WL group and HD-NBI group(ADR:33.5%vs.37.7%,P=0.45;ANDR:15.5%vs.10.4%,P=0.18,respectively).In the univariate and multivariate logistic regression analyses,neither HD-WL nor HD-NBI led to a significant difference in overall adenoma detection compared to SD-WL(HD-WL:OR 0.91,P=0.69;HD-NBI:OR 1.15,P=0.80).Conclusion HD-NBI and HD-WL are comparable to SD-WL for overall adenoma detection among Chinese outpatients.It can be concluded that HD-NBI or HD-WL is not superior to SD-WL,but more effective instruction may be needed to guide the selection of different endoscopic methods in the future.Our study’s conclusions may aid in the efficient allocation and utilization of limited colonoscopy resources,especially advanced imaging technologies.
文摘BACKGROUND Conventional magnifying endoscopy with narrow-band imaging(NBI)observation of the gastric body mucosa shows dominant patterns in relation to the regular arrangement of collecting venules,subepithelial capillary network,and gastric pits.AIM To evaluate the effectiveness of a new one-dual(near)focus,NBI mode in the assessment of the microscopic features of gastric body mucosa compared to conventional magnification.METHODS During 2021 and 2022,68 patients underwent proximal gastrointestinal endoscopy using magnification endoscopic modalities subsequently applying acetic acid(AA).The GIF-190HQ series NBI system with dual focus capability was used for the investigation of gastric mucosa.At the time of the endoscopy,the gastric body mucosa of all enrolled patients was photographed using the white light endoscopy(WLE),near focus(NF),NF-NBI,AA-NF,and AA-NF-NBI modes.RESULTS The WLE,NF and NF-NBI endoscopic modes for all patients(204 images)were classified in the same order into three groups.Two images from each patient for the AA-NF and AA-NF-NBI endoscopic modes were classified in the same order.According to all three observers who completed the work independently,NF magnification was significantly superior to WLE(P<0.01),and the NF-NBI mode was significantly superior to NF magnification(P<0.01).After applying AA,the three observers confirmed that AA-NF-NBI was significantly superior to AA-NF(P<0.01).Interobserver kappa values for WLE were 0.609,0.704,and 0.598,respectively and were 0.600,0.721,and 0.637,respectively,for NF magnification.For the NF-NBI mode,the values were 0.378,0.471,and 0.553,respectively.For AA-NF,they were 0.453,0.603,and 0.480,respectively,and for AA-NF-NBI,they were 0.643,0.506,and 0.354,respectively.CONCLUSION When investigating gastric mucosa in microscopic detail,NF-NBI was the most powerful endoscopic mode for assessing regular arrangement of collecting venules,subepithelial capillary network,and gastric pits among the five endoscopic modalities investigated in this study.AA-NF-NBI was the most powerful endoscopic mode for analyzing crypt opening and intervening part.
文摘This editorial summarizes the latest literature on the roles of neuronal PAS domain protein 2 and KN motif/ankyrin repeat domain 1 in type 2 diabetes(T2D).We highlight their involvement inβ-cell dysfunction,explore their potential as therapeutic targets,and discuss the implications for new treatment strategies.We offer valuable insights into relevant gene regulation and cellular mechanisms relevant for the targeted management of T2D.