Optical frequency combbased Fourier transform spectroscopy has the features of broad spectral bandwidth,high sensitivity,andmultiplexed trace gas detection,which has valuable application potential in the fields of pre...Optical frequency combbased Fourier transform spectroscopy has the features of broad spectral bandwidth,high sensitivity,andmultiplexed trace gas detection,which has valuable application potential in the fields of precision spectroscopy and trace gas detection.Here,we report the development of a mid-infrared Fourier transform spectrometer based on an optical frequency comb combined with a Herriott-type multipass cell.Using this instrument,the broadband absorption spectra of several important molecules,including methane,acetylene,water molecules and nitrous oxide,are measured by near real-time data acquisition in the 2800-3500 cm^(-1)spectral region.The achieved minimum detectable absorption of the instrument is 4.4×10^(-8)cm^(-1)·Hz^(-1/2)per spectral element.Broadband spectra of H_(2)0 are fited using the Voigt profile multispectral fitting technique and the consistency of the concentration inversion is 1%.Our system also enables precise spectroscopic measurements,and it allows the determination of the spectral line positions and upper state constants of N_(2)O in the(0002)-(1000)band,with results in good agreement with those reported by Toth[Appl.Opt.30,5289(1991)].展开更多
Cowpea (Vigna unguiculata L. Walp) is a multi-purpose legume with high quality protein for human consumption and livestock. The objective of this work was to develop near-infrared spectroscopy (NIRS) prediction models...Cowpea (Vigna unguiculata L. Walp) is a multi-purpose legume with high quality protein for human consumption and livestock. The objective of this work was to develop near-infrared spectroscopy (NIRS) prediction models to estimate protein content in cowpea. A total of 116 cowpea breeding lines with a wide range of protein contents (19.28 % to 32.04%) were selected to build the model using whole seed and ground seed samples. Partial least-squares discriminant analysis (PLS-DA) regression technique with different pre-treatments (derivatives, standard normal variate, and multiplicative scatter correction) were carried out to develop the protein prediction model. Results showed: 1) spectral plots of both the whole seed and ground seed showed higher spectral scatter at higher wavelengths (>1450 nm), 2) data pre-processing affects prediction accuracy for bot whole seed and ground seed samples, 3) prediction using ground seed samples (0.64 R<sup>2</sup> 0.85) is better than the whole seed (0.33 R<sup>2</sup> 0.78), and 4) the data pre-processing second derivative with standard normal variate has the best prediction (R<sup>2</sup>_whole seed = 0.78, R<sup>2</sup>_ground seed = 0.85). The results will be of interest in cowpea breeding programs aimed at improving total seed protein content.展开更多
At present,Tradition Chinese Medicine(TCM)industry in China is in the stage from the empirical development to industrial production.Near infrared(NIR)spectroscopy has been widely used in the quality control of TCM'...At present,Tradition Chinese Medicine(TCM)industry in China is in the stage from the empirical development to industrial production.Near infrared(NIR)spectroscopy has been widely used in the quality control of TCM's modernization with its characteristics incuding rapidness,nondestruction,simplicity,economy,and so on.In this study,as one type of a portable micro NIR spectrometer,Micro NIR 1700 was used to establish the qualitative models for identification of geographical region and authenticity of Radix codonopsis based on discriminant analysis(DA)method.Both of the DA models had better predictive ability with 100%accuracy.In addition,a method for rapid quantitative analysis of polysaccharide in Radix codonopsis was also developed based on Micro NIR 1700 spectrometer with partial last-squares(PLS)algo-rithm.In the PLS calibration model,the NIR.spectra of samples were pretreated with different preprocessing methods and the spectral region was selected with different variable selection methods as well.The performance of the final PLS model was evaluated according to correlation cofficient of calibration(Rc),correlation coefficient of prediction(Rp),root mean squared error of cross validation(RMSECV),and root mean squared of prediction(RMSEP).The values of Re,Rp,RMSECV,and RMSEP were 0.9775,0.9602,2.496,and 2.734 g/mL,respectively.This work demonstrated that micro infrared spectrometer could be more convenient and rapid for quality control of Radix codonopsis,and the presented models would be a u1seful reference for quality control of other simi lar raw materials of TCM.展开更多
In view of the difficulties in traditional long-wave infrared imaging spectrometer which is hard to realize a high signal-to-noise ratio and miniaturization as well under the weak remote sensing signal,Offner convex g...In view of the difficulties in traditional long-wave infrared imaging spectrometer which is hard to realize a high signal-to-noise ratio and miniaturization as well under the weak remote sensing signal,Offner convex grating spectrometer and Dyson concave grating spectrometer,both having concentric structure,are designed and analyzed in the band of 8-12 μm. The diffraction angle expressions of the two spectrometers are obtained and the diffraction characteristics are acquired. Both of the spectrometers are designed in Zemax environment under different F-numbers and different grating constants with the same slit,spatial resolution,spectral resolution and detector. The results show that Dyson grating spectrometer possesses the advantages of higher throughput and smaller volume, and Offner grating spectrometer possesses the advantage of more accessible material and the absence of chromatic aberration. The differences between Dyson form and Offner form show that the former is a better choice in the long-wave infrared imaging spectrometer.展开更多
A miniaturized short-wavelength infrared spectrometer for use with diffuse light was created by combining a thin form factor carbon nanotube composite collimator,a linear variable filter,and an InGaAs photodiode array...A miniaturized short-wavelength infrared spectrometer for use with diffuse light was created by combining a thin form factor carbon nanotube composite collimator,a linear variable filter,and an InGaAs photodiode array.The resulting spectrometer measures 3 mm×4 mm×14 mm and shows a significant improvement in resolution over a spectrometer without the collimator when used with diffuse light.Its small size and high throughput make it ideal for applications such as wearable optical sensing,where light from highly scattering tissue is measured.Plethysmographic measurements on the wrist were demonstrated,showing rapid data collection with diffuse light.展开更多
Near infrared spectroscopy (NIRS) is a method for non-invasive monitoring of cerebral oxygenation and haemodynamics. Different devices provide information on changes of oxygenated (HbO2) and deoxygenated haemoglobin (...Near infrared spectroscopy (NIRS) is a method for non-invasive monitoring of cerebral oxygenation and haemodynamics. Different devices provide information on changes of oxygenated (HbO2) and deoxygenated haemoglobin (HHb), oxidized cytochrome aa3 (CytOx) or regional oxygen saturation (rSO2). NIRS has been used during adult and paediatric cardiac surgery.展开更多
This experiment studies on the used infrared spectroscopy to establish technology methods for liquor identification methods, as well as offers the science data for establishment of the fingerprint in white spirit. The...This experiment studies on the used infrared spectroscopy to establish technology methods for liquor identification methods, as well as offers the science data for establishment of the fingerprint in white spirit. The results have shown that using near-infrared spectroscopy analysis of liquor has the obvious features such as strong specificity, good reproducibility, simple operation, and finally confirmed that it is an authentic and ideal method for identification in white spirit.展开更多
Presenteeism refers to impaired performance attributed to attending work with health problems. There has been no study examining the state of presenteeism with objective measures. We compared cerebral hemodynamic chan...Presenteeism refers to impaired performance attributed to attending work with health problems. There has been no study examining the state of presenteeism with objective measures. We compared cerebral hemodynamic changes, measured by near-infrared spectroscopy (NIRS), during neuropsychological tests conducted by university students with presenteeism and healthy controls. Twenty-two university students participated in the study;11 of them with impaired performance caused by mental health problem were allocated to the presenteeism group and 11 without health problems to the control group. Presenteeism was assessed by the Presenteeism Scale for Students. To evoke hemodynamics changes, the participants completed a Word Fluency Test (WFT) and a Trail Making Test (TMT). The NIRS probes were located over the bilateral prefrontal area. Students with presenteeism had significantly higher incidences of depression than controls. However, there was no significant difference in behavioral performance examinations between the two groups. With regard to hemodynamics changes, the repeated measures analysis of covariance of the NIRS signals revealed significant interactions between group and task activation. Although we observed a significant increase in oxygenated hemoglobin concentration during the WFT among controls (simple main effect;left channel, F(1, 19) = 27.34, P F(1, 19) = 22.05, P < 0.001), no changes were found in students with presenteeism during either the WFT (simple main effect;left channel, F(1, 19) = 0.12, P F(1, 19) = 0.08, P t = ﹣0.94, P with Bonferroni correction = 0.745;right channel, t = ﹣2.19, P with Bonferroni correction < 0.113). This is the first study to reveal differences in activity in the cerebral cortex associated with presenteeism. The fact that students with presenteeism have prefrontal dysfunction might reinforce the concept of presenteeism.展开更多
The performance of a portable near-infrared (NIR) spectrometer to determine organic carbon (OC) in marine sediments was evaluated. The NIR reflection spectra of 180 samples in the range 950 - 1650 nm were acquired usi...The performance of a portable near-infrared (NIR) spectrometer to determine organic carbon (OC) in marine sediments was evaluated. The NIR reflection spectra of 180 samples in the range 950 - 1650 nm were acquired using an ultra-compact spectrometer. NIR spectroscopy combined with the partial least squares (PLS) regression and Savitzky-Golay (SG) smoothing was successfully applied to rapid and reagent-free determination of OC. Using the PLS-SG model with 1nd order derivative, 2th polynomial and eleven smoothing points, the root-mean-square errors (RMSEPM) and correlation coefficients (RP,M) of prediction for modeling were 0.073% and 0.894, respectively, the root-mean-square errors (RMSEPV) and correlation coefficients (RP,V) of prediction for validation were 0.075% and 0.883, respectively. Results showed that the small portable NIR instrument achieved well prediction effect for the analysis of OC in marine sediments, which had advantages of rapid, easy to carry and operate suitable for large-scale applications to analyze marine sediments.展开更多
Depression has been known to reduce the prefrontal activity associated with the execution of certain cognitive tasks, although whether a temporarily depressed or anxious mood in healthy individuals affects the prefron...Depression has been known to reduce the prefrontal activity associated with the execution of certain cognitive tasks, although whether a temporarily depressed or anxious mood in healthy individuals affects the prefrontal blood oxygen level during cognitive tasks is unknown. Combining the measurement of prefrontal activity with near-infrared spectroscopy (NIRS) and the two cognitive tasks, namely the letter version of the verbal fluency test (VFT-l) and the Stroop test, we measured the effect of a depressed or anxious mood and gender on the changes in the prefrontal oxygenated hemoglobin (Oxy-Hb) levels during those cognitive tests in healthy individuals. Depressed mood or anxious mood was assessed by the Hospital Anxiety and Depression Scale (HADS). Thereby we aimed to explore the possibility of NIRS measurement for detecting the early subclinical manifestation of major depression. Moreover, we examined the possible relationships between prefrontal activation and the functional Val66Met polymorphisms of the brain derived neurotropic factor (BDNF) gene and serum BDNF level. As a result, the increased prefrontal Oxy-Hb levels during cognitive tasks were significantly correlated with the severity of depressed mood in males. The course of the prefrontal Oxy-Hb increase was different depending on the cognitive tasks, i.e., the VFT-l or the Stroop test, in both genders. Correlations of BDNF genotype and serum BDNF level with the prefrontal Oxy-Hb levels during those cognitive tasks were negative. Our results suggest that the early subclinical manifestation of depressed mood in males might be detected by the NIRS measurement, which is not correlated with the individual properties of BDNF.展开更多
Near-infrared (NIR) spectrometer based on semiconductor lasers can combine light source and splitter into one, which is an important direction for development of miniature instruments. In order to avoid random interfe...Near-infrared (NIR) spectrometer based on semiconductor lasers can combine light source and splitter into one, which is an important direction for development of miniature instruments. In order to avoid random interference caused by inconsistency between light sources, the novel evaluation indicators for global stability of multi-channels spectral system were proposed based on the correlation between dynamic deviation spectra of any two channels. The NIR analysis of moisture for corn powder samples based on the partial least squares combined with Savitzky-Golay (SG) smoothing was taken as an example, and a spectral correction method for enhancing prediction performance of multi-channels spectral system was further provided using above evaluation indicators. The experiment results showed that the global stability evaluation indicators significantly increased after SG smoothing correction. Meanwhile, the root-mean-square errors of prediction for corn moisture reduced from 0.373 to 0.283 (%), and the correlation coefficient between predicted and actual values was improved from 0.702 to 0.855. The above results indicated that by improving global stability indicators, the prediction ability of multi-channels spectral system can be improved. The proposed method provided a valuable reference for designing multi-channels diminutive spectrometer with high prediction performance, which had significance for large-scale application of NIR technology.展开更多
The synchronous monitoring of cerebral blood flow and blood oxygen levels plays a pivotal role in the prevention,diagnosis,and treatment of cerebrovascular diseases.This study introduces a novel noninvasive device uti...The synchronous monitoring of cerebral blood flow and blood oxygen levels plays a pivotal role in the prevention,diagnosis,and treatment of cerebrovascular diseases.This study introduces a novel noninvasive device utilizing inductive sensing and near-infrared spectroscopy technology to facilitate simultaneous monitoring of cerebral blood flow and blood oxygen levels.The device consists of modules for cerebral blood flow monitoring,cerebral blood oxygen monitoring,control,communication,and a host machine.Through experiments conducted on healthy subjects,it was confirmed that the device can effectively achieve synchronous monitoring and recording of cerebral blood flow and blood oxygen signals.The results demonstrate the device’s capability to accurately measure these signals simultaneously.This technology enables dynamic monitoring of cerebral blood flow and blood oxygen signals with potential clinical applications in preventing,diagnosing,treating cerebrovascular diseases while reducing their associated harm.展开更多
基金supported by the National Natural Science Foundation China(No.42022051,No.U21A2028)Youth Innovation Promotion Association of the Chinese Academy of Sciences(No.Y202089)the HFIPS Director's Fund(No.YZJJ202101,No.BJPY2023A02).
文摘Optical frequency combbased Fourier transform spectroscopy has the features of broad spectral bandwidth,high sensitivity,andmultiplexed trace gas detection,which has valuable application potential in the fields of precision spectroscopy and trace gas detection.Here,we report the development of a mid-infrared Fourier transform spectrometer based on an optical frequency comb combined with a Herriott-type multipass cell.Using this instrument,the broadband absorption spectra of several important molecules,including methane,acetylene,water molecules and nitrous oxide,are measured by near real-time data acquisition in the 2800-3500 cm^(-1)spectral region.The achieved minimum detectable absorption of the instrument is 4.4×10^(-8)cm^(-1)·Hz^(-1/2)per spectral element.Broadband spectra of H_(2)0 are fited using the Voigt profile multispectral fitting technique and the consistency of the concentration inversion is 1%.Our system also enables precise spectroscopic measurements,and it allows the determination of the spectral line positions and upper state constants of N_(2)O in the(0002)-(1000)band,with results in good agreement with those reported by Toth[Appl.Opt.30,5289(1991)].
文摘Cowpea (Vigna unguiculata L. Walp) is a multi-purpose legume with high quality protein for human consumption and livestock. The objective of this work was to develop near-infrared spectroscopy (NIRS) prediction models to estimate protein content in cowpea. A total of 116 cowpea breeding lines with a wide range of protein contents (19.28 % to 32.04%) were selected to build the model using whole seed and ground seed samples. Partial least-squares discriminant analysis (PLS-DA) regression technique with different pre-treatments (derivatives, standard normal variate, and multiplicative scatter correction) were carried out to develop the protein prediction model. Results showed: 1) spectral plots of both the whole seed and ground seed showed higher spectral scatter at higher wavelengths (>1450 nm), 2) data pre-processing affects prediction accuracy for bot whole seed and ground seed samples, 3) prediction using ground seed samples (0.64 R<sup>2</sup> 0.85) is better than the whole seed (0.33 R<sup>2</sup> 0.78), and 4) the data pre-processing second derivative with standard normal variate has the best prediction (R<sup>2</sup>_whole seed = 0.78, R<sup>2</sup>_ground seed = 0.85). The results will be of interest in cowpea breeding programs aimed at improving total seed protein content.
基金supported by the Project of Shandong Province(No.2012CX20203)the Major Special Project of National Scientic Instruments and Equipment Development(No.2014YQ47037709).
文摘At present,Tradition Chinese Medicine(TCM)industry in China is in the stage from the empirical development to industrial production.Near infrared(NIR)spectroscopy has been widely used in the quality control of TCM's modernization with its characteristics incuding rapidness,nondestruction,simplicity,economy,and so on.In this study,as one type of a portable micro NIR spectrometer,Micro NIR 1700 was used to establish the qualitative models for identification of geographical region and authenticity of Radix codonopsis based on discriminant analysis(DA)method.Both of the DA models had better predictive ability with 100%accuracy.In addition,a method for rapid quantitative analysis of polysaccharide in Radix codonopsis was also developed based on Micro NIR 1700 spectrometer with partial last-squares(PLS)algo-rithm.In the PLS calibration model,the NIR.spectra of samples were pretreated with different preprocessing methods and the spectral region was selected with different variable selection methods as well.The performance of the final PLS model was evaluated according to correlation cofficient of calibration(Rc),correlation coefficient of prediction(Rp),root mean squared error of cross validation(RMSECV),and root mean squared of prediction(RMSEP).The values of Re,Rp,RMSECV,and RMSEP were 0.9775,0.9602,2.496,and 2.734 g/mL,respectively.This work demonstrated that micro infrared spectrometer could be more convenient and rapid for quality control of Radix codonopsis,and the presented models would be a u1seful reference for quality control of other simi lar raw materials of TCM.
基金Sponsored by the National High Technology Research and Development Program of China(863 Program)(Grant No.2013AA03A116)
文摘In view of the difficulties in traditional long-wave infrared imaging spectrometer which is hard to realize a high signal-to-noise ratio and miniaturization as well under the weak remote sensing signal,Offner convex grating spectrometer and Dyson concave grating spectrometer,both having concentric structure,are designed and analyzed in the band of 8-12 μm. The diffraction angle expressions of the two spectrometers are obtained and the diffraction characteristics are acquired. Both of the spectrometers are designed in Zemax environment under different F-numbers and different grating constants with the same slit,spatial resolution,spectral resolution and detector. The results show that Dyson grating spectrometer possesses the advantages of higher throughput and smaller volume, and Offner grating spectrometer possesses the advantage of more accessible material and the absence of chromatic aberration. The differences between Dyson form and Offner form show that the former is a better choice in the long-wave infrared imaging spectrometer.
文摘A miniaturized short-wavelength infrared spectrometer for use with diffuse light was created by combining a thin form factor carbon nanotube composite collimator,a linear variable filter,and an InGaAs photodiode array.The resulting spectrometer measures 3 mm×4 mm×14 mm and shows a significant improvement in resolution over a spectrometer without the collimator when used with diffuse light.Its small size and high throughput make it ideal for applications such as wearable optical sensing,where light from highly scattering tissue is measured.Plethysmographic measurements on the wrist were demonstrated,showing rapid data collection with diffuse light.
文摘Near infrared spectroscopy (NIRS) is a method for non-invasive monitoring of cerebral oxygenation and haemodynamics. Different devices provide information on changes of oxygenated (HbO2) and deoxygenated haemoglobin (HHb), oxidized cytochrome aa3 (CytOx) or regional oxygen saturation (rSO2). NIRS has been used during adult and paediatric cardiac surgery.
文摘This experiment studies on the used infrared spectroscopy to establish technology methods for liquor identification methods, as well as offers the science data for establishment of the fingerprint in white spirit. The results have shown that using near-infrared spectroscopy analysis of liquor has the obvious features such as strong specificity, good reproducibility, simple operation, and finally confirmed that it is an authentic and ideal method for identification in white spirit.
文摘Presenteeism refers to impaired performance attributed to attending work with health problems. There has been no study examining the state of presenteeism with objective measures. We compared cerebral hemodynamic changes, measured by near-infrared spectroscopy (NIRS), during neuropsychological tests conducted by university students with presenteeism and healthy controls. Twenty-two university students participated in the study;11 of them with impaired performance caused by mental health problem were allocated to the presenteeism group and 11 without health problems to the control group. Presenteeism was assessed by the Presenteeism Scale for Students. To evoke hemodynamics changes, the participants completed a Word Fluency Test (WFT) and a Trail Making Test (TMT). The NIRS probes were located over the bilateral prefrontal area. Students with presenteeism had significantly higher incidences of depression than controls. However, there was no significant difference in behavioral performance examinations between the two groups. With regard to hemodynamics changes, the repeated measures analysis of covariance of the NIRS signals revealed significant interactions between group and task activation. Although we observed a significant increase in oxygenated hemoglobin concentration during the WFT among controls (simple main effect;left channel, F(1, 19) = 27.34, P F(1, 19) = 22.05, P < 0.001), no changes were found in students with presenteeism during either the WFT (simple main effect;left channel, F(1, 19) = 0.12, P F(1, 19) = 0.08, P t = ﹣0.94, P with Bonferroni correction = 0.745;right channel, t = ﹣2.19, P with Bonferroni correction < 0.113). This is the first study to reveal differences in activity in the cerebral cortex associated with presenteeism. The fact that students with presenteeism have prefrontal dysfunction might reinforce the concept of presenteeism.
文摘The performance of a portable near-infrared (NIR) spectrometer to determine organic carbon (OC) in marine sediments was evaluated. The NIR reflection spectra of 180 samples in the range 950 - 1650 nm were acquired using an ultra-compact spectrometer. NIR spectroscopy combined with the partial least squares (PLS) regression and Savitzky-Golay (SG) smoothing was successfully applied to rapid and reagent-free determination of OC. Using the PLS-SG model with 1nd order derivative, 2th polynomial and eleven smoothing points, the root-mean-square errors (RMSEPM) and correlation coefficients (RP,M) of prediction for modeling were 0.073% and 0.894, respectively, the root-mean-square errors (RMSEPV) and correlation coefficients (RP,V) of prediction for validation were 0.075% and 0.883, respectively. Results showed that the small portable NIR instrument achieved well prediction effect for the analysis of OC in marine sediments, which had advantages of rapid, easy to carry and operate suitable for large-scale applications to analyze marine sediments.
文摘Depression has been known to reduce the prefrontal activity associated with the execution of certain cognitive tasks, although whether a temporarily depressed or anxious mood in healthy individuals affects the prefrontal blood oxygen level during cognitive tasks is unknown. Combining the measurement of prefrontal activity with near-infrared spectroscopy (NIRS) and the two cognitive tasks, namely the letter version of the verbal fluency test (VFT-l) and the Stroop test, we measured the effect of a depressed or anxious mood and gender on the changes in the prefrontal oxygenated hemoglobin (Oxy-Hb) levels during those cognitive tests in healthy individuals. Depressed mood or anxious mood was assessed by the Hospital Anxiety and Depression Scale (HADS). Thereby we aimed to explore the possibility of NIRS measurement for detecting the early subclinical manifestation of major depression. Moreover, we examined the possible relationships between prefrontal activation and the functional Val66Met polymorphisms of the brain derived neurotropic factor (BDNF) gene and serum BDNF level. As a result, the increased prefrontal Oxy-Hb levels during cognitive tasks were significantly correlated with the severity of depressed mood in males. The course of the prefrontal Oxy-Hb increase was different depending on the cognitive tasks, i.e., the VFT-l or the Stroop test, in both genders. Correlations of BDNF genotype and serum BDNF level with the prefrontal Oxy-Hb levels during those cognitive tasks were negative. Our results suggest that the early subclinical manifestation of depressed mood in males might be detected by the NIRS measurement, which is not correlated with the individual properties of BDNF.
文摘Near-infrared (NIR) spectrometer based on semiconductor lasers can combine light source and splitter into one, which is an important direction for development of miniature instruments. In order to avoid random interference caused by inconsistency between light sources, the novel evaluation indicators for global stability of multi-channels spectral system were proposed based on the correlation between dynamic deviation spectra of any two channels. The NIR analysis of moisture for corn powder samples based on the partial least squares combined with Savitzky-Golay (SG) smoothing was taken as an example, and a spectral correction method for enhancing prediction performance of multi-channels spectral system was further provided using above evaluation indicators. The experiment results showed that the global stability evaluation indicators significantly increased after SG smoothing correction. Meanwhile, the root-mean-square errors of prediction for corn moisture reduced from 0.373 to 0.283 (%), and the correlation coefficient between predicted and actual values was improved from 0.702 to 0.855. The above results indicated that by improving global stability indicators, the prediction ability of multi-channels spectral system can be improved. The proposed method provided a valuable reference for designing multi-channels diminutive spectrometer with high prediction performance, which had significance for large-scale application of NIR technology.
基金National Natural Science Foundation of China(No.51977214)Science and Technology Research Project of Chongqing Education Commission(No.KJQN202212805)Special funding project of Army Medical University(No.2021XJS08)。
文摘The synchronous monitoring of cerebral blood flow and blood oxygen levels plays a pivotal role in the prevention,diagnosis,and treatment of cerebrovascular diseases.This study introduces a novel noninvasive device utilizing inductive sensing and near-infrared spectroscopy technology to facilitate simultaneous monitoring of cerebral blood flow and blood oxygen levels.The device consists of modules for cerebral blood flow monitoring,cerebral blood oxygen monitoring,control,communication,and a host machine.Through experiments conducted on healthy subjects,it was confirmed that the device can effectively achieve synchronous monitoring and recording of cerebral blood flow and blood oxygen signals.The results demonstrate the device’s capability to accurately measure these signals simultaneously.This technology enables dynamic monitoring of cerebral blood flow and blood oxygen signals with potential clinical applications in preventing,diagnosing,treating cerebrovascular diseases while reducing their associated harm.