期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Spectroscopic diagnosis of plasma in atmospheric pressure negative pulsed gas-liquid discharge with nozzle-cylinder electrode
1
作者 孙明 陶瞻 +2 位作者 朱志鹏 王东 潘文军 《Plasma Science and Technology》 SCIE EI CAS CSCD 2018年第5期30-35,共6页
The plasma characteristics of a gas-liquid phase discharge reactor were investigated by optical and electrical methods.The nozzle-cylinder electrode in the discharge reactor was supplied witha negative nanosecond puls... The plasma characteristics of a gas-liquid phase discharge reactor were investigated by optical and electrical methods.The nozzle-cylinder electrode in the discharge reactor was supplied witha negative nanosecond pulsed generator.The optical emission spectrum diagnosis revealed that OH(A2∑+ → X2Π,306–309 nm),N32(CΠ→B3Πg,337 nm),O(3p5p→3s-5s-0,777.2 nm)and O(3p3p→3s3s0,844.6 nm)were produced in the discharge plasma channels.The electron temperature(Te)was calculated from the emission relative intensity ratio between the atomic O 777.2 nm and 844.6 nm,and it increased with the applied voltage and the pulsed frequency and fell within the range of 0.5–0.8 e V.The gas temperature(Tg)that was measured by Lifbase was in a range from 400 K to 600 K. 展开更多
关键词 gas-liquid negative pulsed discharge discharge plasma reactivate species nozzle-cylinder electrode DIAGNOSIS
下载PDF
THEORY AND EXPERIMENT ON THE VISCOUS HEATING OF FLUID DAMPER UNDER SHOCK ENVIRONMENT 被引量:2
2
作者 CHU Deying ZHANG Zhiyi +2 位作者 WANG Gongxian HUA Hongxing WANG Yu 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2008年第3期66-71,共6页
A specially designed fluid damper used as negative shock pulse generator in the shock resistance test system to dissipate the shock input energy in transient time duration is presented. The theoretical modeling based ... A specially designed fluid damper used as negative shock pulse generator in the shock resistance test system to dissipate the shock input energy in transient time duration is presented. The theoretical modeling based on the three-dimensional equation of heat transfer through a fluid element is created to predict the viscous heating in the fluid damper under shock conditions. A comprehensive experimental program that investigates the problem of viscous heating in the fluid damper under different shock conditions is conducted on the shock test machine to validate the analytical expression. Temperature histories for the fluid within the damper at two locations, the annular-oriflce and the-end-of stroke of the damper, are recorded. The experimental results show that the theoretical model can offer a very dependable prediction for the temperature histories in the damper for increasing input velocity. The theoretical model and experimental data both clearly indicate that the viscous heating in the damper is directly related to the maximum shock velocity input and the pressure between the two sides of the piston head. 展开更多
关键词 Fluid damper negative shock pulse generator Viscous heating Shock conditions
下载PDF
NUMERICAL MODELING OF MULTI-CYLINDER ELECTRO-HYDRAULIC SYSTEM AND CONTROLLER DESIGN FOR SHOCK TEST MACHINE
3
作者 CHU Deying ZHANG Zhiyi WANG Gongxian HUA Hongxing 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2007年第2期109-114,共6页
A high fidelity dynamic model of a high-energy hydraulically-actuated shock test machine for heavy weight devices is presented to satisfy the newly-built shock resistance standard and simulate the actual underwater ex... A high fidelity dynamic model of a high-energy hydraulically-actuated shock test machine for heavy weight devices is presented to satisfy the newly-built shock resistance standard and simulate the actual underwater explosion environments in laboratory as well as increase the testing capability of shock test machine. In order to produce the required negative shock pulse in the given time duration, four hydraulic actuators are utilized. The model is then used to formulate an advanced feedforward controller for the system to produce the required negative waveform and to address the motion synchronization of the four cylinders. The model provides a safe and easily controllable way to perform a "virtual testing" before starting potentially destructive tests on specimen and to predict performance of the system. Simulation results have demonstrated the effectiveness of the controller. 展开更多
关键词 Shock test machine negative shock pulse Actuator redundancy Feedforward controller Virtual testing
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部