期刊文献+
共找到15篇文章
< 1 >
每页显示 20 50 100
A novel SVPWM strategy considering neutral-point potential balancing for three-level NPC inverter 被引量:2
1
作者 陈国呈 宋文祥 +1 位作者 武慧 孙承波 《Journal of Shanghai University(English Edition)》 CAS 2006年第1期53-58,共6页
This paper proposes a novel SVPWM (space vector pulse width modulation) strategy for the three-level neutral-point-clamped voltage source inverter, based on the particular disposition of all the redundant voltage ve... This paper proposes a novel SVPWM (space vector pulse width modulation) strategy for the three-level neutral-point-clamped voltage source inverter, based on the particular disposition of all the redundant voltage vectors. The new modulation approach shows superior performance for harmonic voltage and balancing control of neutral-point potential compared to the popular eight-stage centered SVPWM. It realizes suppression of inverter neutral-point potential variation by accurately modifying redundant factor of small vectors pairs, only requiring information of DC-link capacitor voltages and three-phase load currents. This is convenient to apply and is compatible of digital computer realization. Feasibility of the proposed control approach is verified by simulation and experimental results. 展开更多
关键词 neutral-point-clamped inverter neutral-point potential control SVPWM distribution factor.
下载PDF
A Modified Neutral-point Voltage Control Strategy for Three-level Inverters Based on Decomposition of Space Vector Diagram 被引量:1
2
作者 Dereje Woldegiorgis H.Alan Mantooth 《CES Transactions on Electrical Machines and Systems》 CSCD 2022年第2期124-134,共11页
Capacitor voltage imbalance is a significant problem for three-level inverters.Due to the mid-point modulation of these inverter topologies,the neutral point potential moves up or down depending on the neutral point c... Capacitor voltage imbalance is a significant problem for three-level inverters.Due to the mid-point modulation of these inverter topologies,the neutral point potential moves up or down depending on the neutral point current direction creating imbalanced voltages among the two capacitors.This imbalanced capacitor voltage causes imbalanced voltage stress among the semiconductor devices and causes increase output voltage and current harmonics.This paper introduces a modified voltage balancing strategy using two-level space vector modulation.By decomposing the three-level space vector diagram into two-level space vector diagram and redistributing the dwell times of the two-level zero space vectors,the modified voltage balancing method ensures minimal NP voltage ripple.Compared to the commonly used NP voltage control method(using 3L SVM[9]),the proposed modified NP voltage control method offers a slightly higher neutral-point voltage ripple and output voltage harmonics but,it has much lower switching loss,code size and execution time. 展开更多
关键词 three-level inverter Neutral-point voltage control Execution time
下载PDF
Research of Wavelet Modulation for Single-Phase Three-Level Inverter
3
作者 Hongchen Liu Guolei Fan Zhenxia Su 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2017年第1期11-18,共8页
The single-phase three-level voltage source inverter based on wavelet modulation(WM) is proposed.The WM technique is based on constructing a nondyadic-type multi-resolution analysis(MRA),which supports sampling contin... The single-phase three-level voltage source inverter based on wavelet modulation(WM) is proposed.The WM technique is based on constructing a nondyadic-type multi-resolution analysis(MRA),which supports sampling continuous-time sinusoidal signals in a nonuniform recurrent manner,and then reconstructing it by using inverter switching actions. In order to further improve the output voltage waveform and reduce harmonic distortion,the wavelet modulation is used to three-level inverter. The high magnitude of fundamental component and significantly reduced harmonic contents of the inverter output voltage can be achieved by using WM in the single-phase three-level voltage source inverter. Furthermore,the WM algorithm is implemented by using only one element government(EV) in DSP. The simulated and experimental results prove the accuracy and feasibility of the WM scheme for single-phase three-level voltage source inverter. 展开更多
关键词 wavelet modulation three-level voltage source inverters harmonic contents fundamental component
下载PDF
A neutral point potential drift control method for NPC three-level inverter
4
作者 吴琳 Qi Xin +2 位作者 Shi Xiangyang Su Tao Tao Yong 《High Technology Letters》 EI CAS 2021年第3期256-261,共6页
The output current harmonic distortion of a three-level inverter is less than the traditional twolevel inverter.The voltage stress of the semiconductor switch is low.A neutral point potential drift control method is p... The output current harmonic distortion of a three-level inverter is less than the traditional twolevel inverter.The voltage stress of the semiconductor switch is low.A neutral point potential drift control method is proposed to solve the problem of the neutral point potential drift of the three-level inverter.The interaction mechanism between the neutral point potential and the space voltage vector is presented.The small vector output by the inverter is found to be the root cause of the midpoint potential drift.It is found that the fluctuation of the midpoint potential could be suppressed by increasing the capacitance value of the inverter bus voltage stabilizing capacitor.Furthermore,it inhibits the fluctuation of the midpoint potential.The experimental results verify the efficiency and precision of the proposed method. 展开更多
关键词 neutral-point potential drift space voltage vector three-level inverter small vector output inverter bus voltage stabilizing
下载PDF
Ride through Strategy for a Three-Level Dual Z-Source Inverter Using TRIAC
5
作者 A. Nazar Ali Dr. R. Jeyabharath 《Circuits and Systems》 2016年第11期3911-3921,共11页
A new ride through strategy is introduced in a three-level dual Z-source inverter, for isolation under semiconductor switching failure condition. Here the output will have no significant decrease in the amplitude and ... A new ride through strategy is introduced in a three-level dual Z-source inverter, for isolation under semiconductor switching failure condition. Here the output will have no significant decrease in the amplitude and quality. Instead of diodes, the triacs are added to the inverter source ends, as it can perform a bidirectional power transfer also it can operate well in both low and high voltage operating conditions. The faulted part can be isolated by simply altering the firing pulses for turning on/off the triacs using the carrier based SPWM technique and resulting in a boosting output with zero common mode voltage. Consequently, it forms a common floating point or null point with a zero common mode voltage. It is experimentally verified by using MATLAB, and digital oscilloscope. 展开更多
关键词 Common Mode Voltage Fault Compensation three-level inverter Sinusoidal Pulse Width Modulation Z-Source inverter
下载PDF
A Study of DTC-Power Electronic Cascade Fed by Photovoltaic Cell-Three-Level NPC Inverter
6
作者 Iqbal Messaif El-Madjid Berkouk Nadia Saadia 《Smart Grid and Renewable Energy》 2010年第3期109-118,共10页
This paper proposes a high performance three-level inverter Neutral Point Clamped (NPC) structure for photovoltaic system. The proposed configuration which can boost the low voltage of photovoltaic (PV) array, can als... This paper proposes a high performance three-level inverter Neutral Point Clamped (NPC) structure for photovoltaic system. The proposed configuration which can boost the low voltage of photovoltaic (PV) array, can also convert the photovoltaic DC power into high quality AC power. Attention has been paid to the problem of neutral point potential variation. In this way, a Direct Torque Control (DTC) technique has been applied and the estimated value of the Neutral Point Potential (NPP) is used, which is calculated by motor currents. This control strategy uses the redundancy presented by the inverter for selecting appropriate switching state through a switching table to achieve the control of NPP. This study shows the effect of the stability problem of the DC voltages and good static and dynamic performances were obtained in simulation of the proposed cascade “photovoltaic cell-three-level NPC VSI-induction motor”. 展开更多
关键词 DTC Switching Table NPC three-level inverter Photovoltaic Neutral Point Potential Redundant States
下载PDF
Three-level inverter configuration with common mode voltage elimination for induction motor drive (To continue)
7
《变频器世界》 2006年第5期27-28,共2页
The multiplicity of vector combinations for vectors of combined three-level inverters plays an important role, when deciding on the modulation scheme, to obtain minimum switching per inverter vector change, as describ... The multiplicity of vector combinations for vectors of combined three-level inverters plays an important role, when deciding on the modulation scheme, to obtain minimum switching per inverter vector change, as described in the next Section. This is not possible with reduced common-mode three-level inverter structure, obtained with a five-level cascaded H-bridge configuration, as the space vectors locations do not exhibit multiplicity. Moreover, the proposed configuration requires only two power supplies, whereas the scheme with the five-level H-bridge configuration requires six isolated power supplies. 展开更多
关键词 MODE To continue three-level inverter configuration with common mode voltage elimination for induction motor drive
下载PDF
Three-level inverter configuration with common mode voltage elimination for induction motor drive
8
《变频器世界》 2006年第6期26-27,共2页
The multiplicity of vector combinations for vectors of combined three-level inverters plays an important role, when deciding on the modulation scheme, to obtain minimum switching per inverter vector change, as describ... The multiplicity of vector combinations for vectors of combined three-level inverters plays an important role, when deciding on the modulation scheme, to obtain minimum switching per inverter vector change, as described in the next Section. This is not possible with reduced common-mode three-level inverter structure, obtained with a five-level cascaded H-bridge configuration, as the space vectors locations do not exhibit multiplicity. Moreover, the proposed configuration requires only two power supplies, whereas the scheme with the five-level H-bridge configuration requires six isolated power supplies. 展开更多
关键词 MODE three-level inverter configuration with common mode voltage elimination for induction motor drive
下载PDF
Impedance Modeling and Stability Analysis of a Three-phase Three-level NPC Inverter Connected to the Grid 被引量:4
9
作者 Bo Zhang Xiong Du +2 位作者 Jingbo Zhao Jiapei Zhou Xiaoming Zou 《CSEE Journal of Power and Energy Systems》 SCIE CSCD 2020年第2期270-278,共9页
The interaction between grid-connected inverters and the grid may cause stability issues,and compromise the reliable operation of the inverters.This study investigates the stability of a three-level neutral point clam... The interaction between grid-connected inverters and the grid may cause stability issues,and compromise the reliable operation of the inverters.This study investigates the stability of a three-level neutral point clamped(NPC)inverter connected to the grid using impedance-based methods.Because the impedance model of a three-phase three-level NPC inverter has not yet been reported,this study fills the literature gap by analyzing the influence of three-level DC-side neutral point control on the impedance characteristics.By fully considering the DC bus dynamics and DC voltage control loop,and the current loop and phase-locked loop(PLL),the admittance model of a three-phase three-level NPC inverter is established and verified by simulation.Additionally,in the stability analysis of a threelevel NPC inverter grid-connected system,the frequency coupling introduced by the PLL and DC bus dynamics is included with the help of an established admittance model.The stability of the grid-connected system under different grid short circuit ratios(SCR)and operating power levels is analyzed according to the Nyquist stability criterion.The experimental results revealed that the established impedance model of the three-phase three-level NPC inverter can properly represent the stability of this system. 展开更多
关键词 Grid-connected inverter neutral point control STABILITY three-level
原文传递
Direct torque control of doubly fed induction motor using three-level NPC inverter 被引量:3
10
作者 Najib El Ouanjli Aziz Derouich +4 位作者 Abdelaziz El Ghzizal Mohammed Taoussi Youness El Mourabit Khalid Mezioui Badre Bossoufi 《Protection and Control of Modern Power Systems》 2019年第1期208-216,共9页
This article presents the direct torque control (DTC) strategy for the doubly fed induction motor (DFIM) connected to two three-level voltage source inverters (3LVSIs) with neutral point clamped (NPC) structure. This ... This article presents the direct torque control (DTC) strategy for the doubly fed induction motor (DFIM) connected to two three-level voltage source inverters (3LVSIs) with neutral point clamped (NPC) structure. This control method allows to reduce the torque and flux ripples as well as to optimize the total harmonic distortion (THD) of motor currents. The use of 3LVSI increases the number of generated voltage, which allows improving the quality of its waveform and thus improves the DTC strategy. The system modeling and control are implemented in Matlab/Simulink environment. The analysis of simulation results shows the better performances of this control, especially in terms of torque and flux behavior, compared to conventional DTC. 展开更多
关键词 Direct torque control Doubly fed induction motor three-level inverter RIPPLES Switching table
原文传递
Unified power quality conditioner based on a three-level NPC inverter using fuzzy control techniques for all voltage disturbances compensation 被引量:1
11
作者 Salim CHENNAI M-T BENCHOUIA 《Frontiers in Energy》 SCIE CSCD 2014年第2期221-239,共19页
This paper presents a novel and efficient control scheme for unified power quality conditioner (UPQC) based on three-level neutral point clamped (NPC) inverter using fuzzy logic techniques. The proposed UPQC is ca... This paper presents a novel and efficient control scheme for unified power quality conditioner (UPQC) based on three-level neutral point clamped (NPC) inverter using fuzzy logic techniques. The proposed UPQC is capable of mitigating source current harmonics and compensate all voltage disturbances such as voltage sags, swells, unbalances and harmonics. It is designed by the integration of series and shunt active filters (AFs) sharing a common DC bus capacitor. The DC voltage is maintained constant using proportional integral voltage controller. The synchronous reference frame (SRF) theory is used to get the reference signals for shunt active power filters (APFs) and the power reactive theory (p-q theory) for series APFs. The shunt and series APF reference signals derived from the control algorithm and sensed signals are injected in two controllers to generate switching signals. To improve the UPQC capability, fuzzy logic techniques are introduced to control the series APF. The performances of the proposed UPQC system are evaluated in terms of power factor correction, mitigation of voltage or current harmonics and all other voltage disturbances compensation using Matlab-Simulink software and SimPowerSystem toolbox. The simulation results illustrate the performance of the proposed UPQC at the common connection point of the nonlinear load to improve the power energy quality. 展开更多
关键词 three-level neutral point clamped (NPC) inverter unified power quality conditioner (UPQC) current
原文传递
Wind energy conversion system using perturb&observe-based maximum power point approach interfaced with T-type three-level inverter connected to grid
12
作者 Pranupa S A.T.Sriram S.Nagaraja Rao 《Clean Energy》 EI 2022年第4期534-549,共16页
In this paper,the performance of a permanent magnet synchronous generator(PMSG)-based wind energy conversion system(WECS)supplied to an uncontrolled rectifier-fed boost converter(BC)interfaced with a three-phase T-typ... In this paper,the performance of a permanent magnet synchronous generator(PMSG)-based wind energy conversion system(WECS)supplied to an uncontrolled rectifier-fed boost converter(BC)interfaced with a three-phase T-type three-level inverter(TLI)has been analysed.The proposed WECS involves three converters,namely an uncontrolled rectifier that is used for conversion from AC to DC;a BC supplied by a PMSG-fed rectifier used to enhance the voltage gain;and a grid-connected three-phase T-type TLI is proposed to eliminate power-quality issues with synchronization of grid voltage and current.The main goal of this research is to model and control the grid-connected T-type TLI using a d-q synchronous frame for wind energy for regulating the DC-link voltage and transferring the generated wind power from the BC to the grid.Furthermore,the perturb&observe(P&O)-based maximum power point(MPP)approach is recommended to keep track of the MPP for a BC that is supplied from a PMSG-based WECS under constant and variable wind speeds.The proposed PMSG-based WECS interfaced with grid-connected T-type TLI using d-q control has been computationally modelled,simulated and validated with constant and variable speeds using MATLAB®and Simulink®.It is confirmed that the P&O-based MPP approach ensures maximum power for varying wind speeds,and the total harmonic distortion of the T-type TLI grid current value is 3.18%,which is within IEEE-519 limits.Furthermore,with grid synchronization,the power factor of the T-type TLI is maintained at unity to avoid power-quality issues. 展开更多
关键词 boost converter grid synchronization perturb&observe T-type three-level inverter wind turbine
原文传递
Multi-objective Model Predictive Control of Grid-connected Three-level Inverter Based on Hierarchical Optimization
13
作者 Ting Liu Yong Li +4 位作者 Li Jiang Jianghu Wan Jiaqi Yu Chao Ding Yijia Cao 《Chinese Journal of Electrical Engineering》 CSCD 2021年第1期63-72,共10页
In order to solve the problem of weighting factors selection in the conventional finite-control-set model predictive control for a grid-connected three-level inverter,an improved multi-objective model predictive contr... In order to solve the problem of weighting factors selection in the conventional finite-control-set model predictive control for a grid-connected three-level inverter,an improved multi-objective model predictive control without weighting factors based on hierarchical optimization is proposed.Four control objectives are considered in this strategy.The grid current and neutral-point voltage of the DC-link are taken as the objectives in the first optimization hierarchy,and by using fuzzy satisfaction decision,several feasible candidates of voltage vectors are determined.Then,the average switching frequency and common-mode voltage are optimized in the second hierarchy.The average ranking criterion is introduced to sort the objective functions,and the best voltage vector is obtained to realize the coordinated control of multiple objectives.At last,the effectiveness of the proposed strategy is verified by simulation results. 展开更多
关键词 Multi-objective model predictive control grid-connected three-level inverter hierarchical optimization fuzzy satisfaction decision average ranking criterion
原文传递
Sliding mode approach applied to sensorless direct torque control of cage asynchronous motor via multi-level inverter 被引量:3
14
作者 Soukaina El Daoudi Loubna Lazrak Mustapha Ait Lafkih 《Protection and Control of Modern Power Systems》 2020年第1期166-175,共10页
To improve the robustness and performance of the dynamic response of a cage asynchronous motor,a direct torque control(DTC)based on sliding mode control(SMC)is adopted to replace traditional proportional-integral(PI)a... To improve the robustness and performance of the dynamic response of a cage asynchronous motor,a direct torque control(DTC)based on sliding mode control(SMC)is adopted to replace traditional proportional-integral(PI)and hysteresis comparators.The combination of the proposed strategy with sinusoidal pulse width modulation(SPWM)applied to a three-level neutral point clamped(NPC)inverter brings many advantages such as a reduction in harmonics,and precise and rapid tracking of the references.Simulations are performed for a three-level inverter with SM-DTC,a two-level inverter with SM-DTC and the three-level inverter with PI-DTC-SPWM.The results show that the SM-DTC method achieves better performance in terms of reference tracking,while adoption of the threelevel inverter topology can effectively reduce the ripples.Applying the SM-DTC to the three-level inverter presents the best solution for achieving efficient and robust control.In addition,the use of a sliding mode speed estimator eliminates the mechanical sensor and this increases the reliability of the system. 展开更多
关键词 Asynchronous cage motor Direct torque control Sinusoidal pulse width modulation Sliding mode control Speed estimator three-level inverter
原文传递
In-situ Health Monitoring of IGBT Modules of an On-line Medium-voltage Inverter System Using Industrial Internet of Things
15
作者 Mingyao Ma Bing Ji +3 位作者 Jinsong Han Jianing Wang Mingyue Zhan Nianwen Xiang 《CSEE Journal of Power and Energy Systems》 SCIE CSCD 2020年第3期638-648,共11页
Requirements of the Internet of things for the network includes the ability to monitor the equipment and devices.Nowadays,the reliability of a power electronics converter has raised concerns of both academia and indus... Requirements of the Internet of things for the network includes the ability to monitor the equipment and devices.Nowadays,the reliability of a power electronics converter has raised concerns of both academia and industry.In particular,power semiconductor devices are continuously exposed to excessive stress while being designed with high power handling capability and are considered as the most fragile component in power converters suffering from a high failure rate.Aiming to find an effective monitoring method which is also helpful for the Internet of Things and improve the reliability of a three-level neutral-point-clamped power inverter,an in-situ health monitoring method is proposed by harnessing the inverter operational characteristics and degradation sensitive electrical parameters to address the IGBT wire bonding faults.The zero voltage state provides an inherent redundant feature that allows for a power switch to be diagnosed during its normal operation in a neutralpoint-clamped power inverter.The proposed prognostic approach obtains both the wire bonding failure features and junction temperature from the terminals of an IGBT module,which is regarded as non-invasive on-line health monitoring.The system performance can be affected by the designated testing point and testing window,which is discussed and experimentally validated.The proposed technique allows unhealthy wire bonding in IGBT modules online monitoring during the operational period of the inverter.And the proposed in-situ health monitoring of IGBT modules can be used for the industrial Internet of things. 展开更多
关键词 IGBT health monitoring temperature sensitive electrical parameter(TSEP) three-level inverters RELIABILITY
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部