Boron neutron capture therapy(BNCT)is recognized as a precise binary targeted radiotherapy technique that effectively eliminates tumors through the^(10)B(n,α)^(7)Li nuclear reaction.Among various neutron sources,acce...Boron neutron capture therapy(BNCT)is recognized as a precise binary targeted radiotherapy technique that effectively eliminates tumors through the^(10)B(n,α)^(7)Li nuclear reaction.Among various neutron sources,accelerator-based sources have emerged as particularly promising for BNCT applications.The^(7)Li(p,n)^(7)Be reaction is highly regarded as a potential neutron source for BNCT,owing to its low threshold energy for the reaction,significant neutron yield,appropriate average neutron energy,and additional benefits.This study utilized Monte Carlo simulations to model the physical interactions within a lithium target subjected to proton bombardment,including neutron moderation by an MgF_(2)moderator and subsequent BNCT dose analysis using a Snyder head phantom.The study focused on calculating the yields of epithermal neutrons for various incident proton energies,finding an optimal energy at 2.7 MeV.Furthermore,the Snyder head phantom was employed in dose simulations to validate the effectiveness of this specific incident energy when utilizing a^(7)Li(p,n)^(7)Be neutron source for BNCT purposes.展开更多
The neutron yield in the12C(d,n)13N reaction and the proton yield in the12C(d,p)13C reaction have been measured using deuteron beams of energies 0.6-3 MeV.The deuteron beam is delivered from a 4-MeV electrostatic acce...The neutron yield in the12C(d,n)13N reaction and the proton yield in the12C(d,p)13C reaction have been measured using deuteron beams of energies 0.6-3 MeV.The deuteron beam is delivered from a 4-MeV electrostatic accelerator and bombarded on a thick carbon target.The neutrons are detected at 0°,24°,and 48°and the protons at135°in the laboratory frame.Further,the ratio of the neutron yield to the proton yield was calculated.This can be used to effectively recognize the resonances.The resonances are found at 1.4 MeV,1.7 MeV,and 2.5 MeV in the12C(d,p)13C reaction,and at 1.6 MeV and 2.7 MeV in the12C(d,n)13N reaction.The proposed method provides a way to reduce systematic uncertainty and helps confirm more resonances in compound nuclei.展开更多
文摘Boron neutron capture therapy(BNCT)is recognized as a precise binary targeted radiotherapy technique that effectively eliminates tumors through the^(10)B(n,α)^(7)Li nuclear reaction.Among various neutron sources,accelerator-based sources have emerged as particularly promising for BNCT applications.The^(7)Li(p,n)^(7)Be reaction is highly regarded as a potential neutron source for BNCT,owing to its low threshold energy for the reaction,significant neutron yield,appropriate average neutron energy,and additional benefits.This study utilized Monte Carlo simulations to model the physical interactions within a lithium target subjected to proton bombardment,including neutron moderation by an MgF_(2)moderator and subsequent BNCT dose analysis using a Snyder head phantom.The study focused on calculating the yields of epithermal neutrons for various incident proton energies,finding an optimal energy at 2.7 MeV.Furthermore,the Snyder head phantom was employed in dose simulations to validate the effectiveness of this specific incident energy when utilizing a^(7)Li(p,n)^(7)Be neutron source for BNCT purposes.
基金partially supported by the Strategic Priority Research Program of the Chinese Academy of Sciences(Nos.XDB16 and XDPB09)the National Natural Science Foundation of China(Nos.11890714 and 11421505)the Key Research Program of Frontier Sciences of the CAS(No.QYZDJ-SSW-SLH002)
文摘The neutron yield in the12C(d,n)13N reaction and the proton yield in the12C(d,p)13C reaction have been measured using deuteron beams of energies 0.6-3 MeV.The deuteron beam is delivered from a 4-MeV electrostatic accelerator and bombarded on a thick carbon target.The neutrons are detected at 0°,24°,and 48°and the protons at135°in the laboratory frame.Further,the ratio of the neutron yield to the proton yield was calculated.This can be used to effectively recognize the resonances.The resonances are found at 1.4 MeV,1.7 MeV,and 2.5 MeV in the12C(d,p)13C reaction,and at 1.6 MeV and 2.7 MeV in the12C(d,n)13N reaction.The proposed method provides a way to reduce systematic uncertainty and helps confirm more resonances in compound nuclei.