Microbridge testing is used to measure the Young's modulus and residual stresses of metallic films.Nickel film microbridges with widths of several hundred microns are fabricated by Microelectromechanical Systems.I...Microbridge testing is used to measure the Young's modulus and residual stresses of metallic films.Nickel film microbridges with widths of several hundred microns are fabricated by Microelectromechanical Systems.In order to measure the mechanical properties of nickel film microbridges,special shaft structure is designed to solve the problem of getting the load--deflection curves of metal film microbridge by Nanoin--denter XP system with normal Berkovich probe.Theoretical analysis of the micro--bridge load--deflection curve is proposed to evaluate the Young's modulus and residual stress of the films simultaneously.The calculated results based on the experimental measurements show that the average Young's modulus and residual stress are around 190GPa and 175MPa respectively,while the Young's modulus measured by Nano-hardness method on nickel film with silicon substrate is 186.8±7.34GPa.展开更多
基金This work was supported by the National Key Fundamental Research and Development Program(No.G1999033103),The measurements were conducted at the State Key Laboratory of Nonlinear Mechanics(LNM),Institute of Mechanics,Chinese Academy of Sciences.
文摘Microbridge testing is used to measure the Young's modulus and residual stresses of metallic films.Nickel film microbridges with widths of several hundred microns are fabricated by Microelectromechanical Systems.In order to measure the mechanical properties of nickel film microbridges,special shaft structure is designed to solve the problem of getting the load--deflection curves of metal film microbridge by Nanoin--denter XP system with normal Berkovich probe.Theoretical analysis of the micro--bridge load--deflection curve is proposed to evaluate the Young's modulus and residual stress of the films simultaneously.The calculated results based on the experimental measurements show that the average Young's modulus and residual stress are around 190GPa and 175MPa respectively,while the Young's modulus measured by Nano-hardness method on nickel film with silicon substrate is 186.8±7.34GPa.