期刊文献+
共找到1,016篇文章
< 1 2 51 >
每页显示 20 50 100
Effect of heat-activated nickel-titanium arch wire for orthodontic treatment on local tissue inflammation and bone destruction
1
作者 Yan-Fang Duan Min-Jie Fan 《Journal of Hainan Medical University》 2018年第6期81-84,共4页
Objective:To study the effect of heat-activated nickel-titanium arch wire for orthodontic treatment on local tissue inflammation and bone destruction.Methods:Patients who received orthodontic treatment with nickel-tit... Objective:To study the effect of heat-activated nickel-titanium arch wire for orthodontic treatment on local tissue inflammation and bone destruction.Methods:Patients who received orthodontic treatment with nickel-titanium arch wire in Hancheng People's Hospital between March 2012 and October 2017 were retrospectively studied, and according to the nickel-titanium arch wire materials in history data, the patients were divided into the experimental group who used heat-activated nickel-titanium arch wire and the control group who used common nickel-titanium arch wire. 1 week after treatment, the gingival crevicular fluid was collected to determine the contents of inflammatory cytokines as well as the mRNA expression of osteoblast markers and osteoclast markers.Results: 1 week after treatment, IL-1α, IL-1β, sTREM1 and HMGB1 contents as well as RANKL, 5-LOX, LTB4, TRACP5b and ODF mRNA expression in gingival crevicular fluid of experimental group were significantly lower than those of control group whereas OPG, Wnt3a, Runx2, OC, ALP and OCIF mRNA expression were significantly higher than those of control group.Conclusion: Heat-activated nickel-titanium arch wire for orthodontic treatment can be more effective than common nickel-titanium arch wire to reduce the local tissue inflammation and inhibit the bone destruction. 展开更多
关键词 Orthodontic treatment Heat-activated nickel-titanium ARCH WIRE INFLAMMATION Bone destruction Apoptosis
下载PDF
镀镍石墨烯/钛复合材料界面力学行为的分子动力学研究
2
作者 王锐 韩秀丽 +2 位作者 康鹏超 李婉莹 武高辉 《精密成形工程》 北大核心 2024年第4期45-52,共8页
目的研究拉伸载荷下镀镍石墨烯/钛复合材料界面的应力-应变行为。方法采用分子动力学模拟方法,建立了镀镍石墨烯/钛复合材料界面的单晶模型,研究了不同方向拉伸载荷下材料的力学行为。结果镀镍石墨烯复合材料的力学性能随着镀层厚度的... 目的研究拉伸载荷下镀镍石墨烯/钛复合材料界面的应力-应变行为。方法采用分子动力学模拟方法,建立了镀镍石墨烯/钛复合材料界面的单晶模型,研究了不同方向拉伸载荷下材料的力学行为。结果镀镍石墨烯复合材料的力学性能随着镀层厚度的增大而提高,镀层镍可以作为位错源使复合材料的位错密度提高,镀层镍塑性变形的滞后使镀镍石墨烯/钛复合材料具有更高的塑性变形能力。结论材料的力学性能更多依赖于镀镍层数,随着镀层厚度的增大,镀镍石墨烯/钛复合材料表现出了更高的抗拉强度,但界面处的裂纹和空洞数量也有所增加,材料的延伸率有所下降。 展开更多
关键词 镀镍石墨烯 钛基复合材料 分子动力学 界面 力学行为
下载PDF
3种镍钛锉预备弯曲根管时抗循环疲劳性能的体外研究
3
作者 王渝鑫 焦任天 +2 位作者 赵莹 王天琪 梁广智 《口腔疾病防治》 2024年第2期101-107,共7页
目的探究不同角度的弯曲根管模型中,不同尖端直径的Woride KS(WKS)、Protaper Gold(PTG)及Hyflex CM(HCM)机用镍钛器械抗循环疲劳性能的差异,为临床上预备弯曲根管时有针对性地选用合适的镍钛器械提供参考。方法选取不同尖端直径20#、25... 目的探究不同角度的弯曲根管模型中,不同尖端直径的Woride KS(WKS)、Protaper Gold(PTG)及Hyflex CM(HCM)机用镍钛器械抗循环疲劳性能的差异,为临床上预备弯曲根管时有针对性地选用合适的镍钛器械提供参考。方法选取不同尖端直径20#、25#(0.20 mm、0.25 mm)的3种全新镍钛锉,WKS(20/0.06)、WKS(25/0.06)、PTG(20/0.07)、PTG(25/0.08)、HCM(20/0.06)、HCM(25/0.06)各20支。根据推荐设置马达的转速和扭矩,于30°和60°的不锈钢根管模型中测试镍钛锉的抗循环疲劳性能,用摄像机及计时器记录镍钛锉从开始旋转到疲劳折断的时间(time from ratation to fatigue fracture,TTF),用游标卡尺测量并记录折断碎片的长度(fragment length,FL)。结果同种锉的TTF比较,①WKS:尖端同直径锉在30°弯曲根管中的TTF均长于60°(P<0.05),同角度弯曲根管中25#锉的TTF均长于20#锉(P<0.05);②PTG:20#锉在30°弯曲根管中的TTF长于60°(P<0.05),25#锉在30°弯曲根管中的TTF与60°无统计学差异(P>0.05),在30°弯曲根管中的20#锉TTF长于25#锉(P<0.05),在60°弯曲根管中20#锉的TTF与25#锉无统计学差异(P>0.05);③HCM:尖端同直径锉在30°弯曲根管中的TTF均长于60°(P<0.05),同角度弯曲根管中20#锉的TTF均长于25#锉。不同锉的TTF比较:在30°弯曲根管中,3种20#锉的TTF无统计学差异(P>0.05),25#WKS的TTF长于其他锉(P<0.05);在60°弯曲根管中,20#HCM的TTF长于尖端同直径的其他锉(P<0.05),25#WKS的TTF长于尖端同直径的HCM(P<0.05)。20#PTG、25#PTG、20#HCM在30°的弯曲根管模型中FL均分别显著长于60°(P<0.05),20#WKS、25#WKS、25#HCM在30°及60°的弯曲根管模型中FL无统计学差异。结论WKS镍钛锉的抗循环疲劳性能在30°模拟弯曲根管内较PTG及HCM镍钛锉有明显优势;而在60°模拟弯曲根管内,20#镍钛锉中HCM镍钛锉的抗循环疲劳性能较其他锉有明显优势,25#镍钛锉中仅WKS镍钛锉的抗循环疲劳性能较HCM镍钛锉有明显优势。 展开更多
关键词 镍钛器械 抗循环疲劳 热处理 弯曲度 弯曲根管 器械分离 Woride KS Protaper Gold Hyflex CM
下载PDF
不同机用镍钛器械在后牙根管治疗中的应用
4
作者 郭莉莉 魏士刚 刘纪雷 《海南医学》 CAS 2024年第8期1124-1127,共4页
目的比较不同机用镍钛器械在后牙根管治疗中的临床应用效果。方法回顾性分析2021年1月至2021年6月于河南中医药大学第一附属医院口腔科行磨牙根管治疗的72例患者的临床资料,根据采用机用镍钛器械的不同分为A组、B组和C组各24例。所有患... 目的比较不同机用镍钛器械在后牙根管治疗中的临床应用效果。方法回顾性分析2021年1月至2021年6月于河南中医药大学第一附属医院口腔科行磨牙根管治疗的72例患者的临床资料,根据采用机用镍钛器械的不同分为A组、B组和C组各24例。所有患者均接受后牙根管治疗,A组采用Wave One Gold机用镍钛器械治疗,B组采用Protaper Gold机用镍钛器械治疗,C组采用Protaper Universal机用镍钛器械治疗。比较三组每个根管预备时间、根管充填质量、临床疗效、牙根微裂情况及术后疼痛情况。结果A组患者的每个根管预备时间为(29.35±4.20)s,明显短于B组的(87.42±8.56)s和C组的(88.23±8.79)s,差异有统计学意义(P<0.05),但B组、C组患者的每个根管预备时间比较差异无统计学意义(P>0.05);A组、B组、C组患者的根管充填质量合格率分别为92.13%、96.47%、94.81%,治疗的总有效率分别为95.83%、91.67%、95.83%,牙根微裂发生率分别为4.17%、4.17%、8.33%,差异均无统计学意义(P>0.05);术后24 h内,三组患者的术后疼痛分级比较差异无统计学意义(P>0.05)。结论Wave One Gold、Protaper Universal、Protaper Gold机用镍钛器械在后牙根管治疗中疗效确切,相比于Wave One Gold,Protaper Universal、Protaper Gold的预备时间较长,且三者均不会明显增加牙根微裂发生率与术后疼痛程度。 展开更多
关键词 镍钛器械 根管预备 临床疗效 牙根微裂 疼痛
下载PDF
四种镍钛单支锉预备弯曲根管的成形效果比较
5
作者 张筱娅 林华洁 +1 位作者 孟伟涛 王静 《郑州大学学报(医学版)》 CAS 北大核心 2024年第1期91-95,共5页
目的:比较4种镍钛单支锉预备弯曲根管的成形效果。方法:选择64颗离体上颌第一磨牙的近中颊根管,根据弯曲度分为中度弯曲组、重度弯曲组,每组再随机分成4个亚组(n=8),分别用4种镍钛单支锉WaveOne Gold、Reciproc Blue、M3-L以及锋度V Blu... 目的:比较4种镍钛单支锉预备弯曲根管的成形效果。方法:选择64颗离体上颌第一磨牙的近中颊根管,根据弯曲度分为中度弯曲组、重度弯曲组,每组再随机分成4个亚组(n=8),分别用4种镍钛单支锉WaveOne Gold、Reciproc Blue、M3-L以及锋度V Blue预备根管,记为WG组、RB组、M3组和VB组。记录各组根管预备时间。采用锥形束CT测算根管偏移量、轴中心率及弯曲度变化。结果:预备过程中均未发生器械变形或折断。同一弯曲程度下各亚组根管预备时间差异无统计学意义(P>0.05)。重度弯曲根管中,M3组弯曲度变化值最小。4种单支锉产生的根管偏移量均<0.30 mm;距根尖3 mm处,WG组根管偏移量最大;距根尖5 mm处,WG组根管偏移量较小,轴中心率最接近1。结论:虽然4种镍钛单支锉均能较好地维持弯曲根管原有的解剖形态,但WaveOne Gold在根管中段具有更好的中心定位能力,M3-L在维持根管弯曲角度上更具优势。 展开更多
关键词 镍钛单支锉 弯曲根管 根管预备 锥形束CT 成形效果
下载PDF
Mechanical properties of nickel-titanium archwire used in the final treatment phase of Tip-Edge Plus technique: an in vitro study 被引量:2
6
作者 SHEN Xiao SUN Xin-hua +3 位作者 TIAN Hua ZHANG Chun-bo YAN Kuo GUO Yong-liang 《Chinese Medical Journal》 SCIE CAS CSCD 2013年第1期135-139,共5页
Background As the only active component in final treatment phase of Tip-Edge Plus technique, the activation of nickel-titanium orthodontic archwires is one of the factors that affect the torque expression. It is neces... Background As the only active component in final treatment phase of Tip-Edge Plus technique, the activation of nickel-titanium orthodontic archwires is one of the factors that affect the torque expression. It is necessary to evaluate the mechanical properties of the nickel-titanium wire used in the final treatment phase in simulated oral environments to forecast the treatment outcomes. Methods The mechanical properties of 171 thermal nickel-titanium wires of 0.35 mm (0.014-in) in diameters with different deflection of 40 mm in length were investigated with three-point bending test. The samples were divided into 2 groups: as-received and bended groups. In the bended group, samples were divided into 7 subgroups according to the amounts of deflection and named by the canine angulations (-25~, -19~, -13~, -7~, -1~, +5~, +11~). The deflection of wires was made by inserting the wires into the deep tunnel of Tip-Edge Plus brackets positioned in plaster casts with different canine angulations to mimic the use of nickel-titanium wires in the final treatment phase. Immersed the bended group in artificial saliva (pH 6.8) and preserved at 37.0~C. Eight durations of incubation were tested: 1 to 8 weeks. Three analogous samples of each group and subgroups were tested per week. Stiffness (YS:E) and the load-deflection characteristics of unloading plateau section were obtained. Results Significant changes in specific mechanical properties were observed in long-term immersed and large deflected wires compared with as-received groups. Both immersion time and deflection affected the mechanical properties of wires in the simulated oral environment, and the two factors had synergistic effect. In groups -25~, -19~ and -13~, stiffness (YS:E) increased then decreased and average plateau force and ratio of variance decreased then increased correspondingly at specific time. Conclusions In the final treatment phase of Tip-Edge Plus technique, the mechanical properties of nickel-titanium wire are associated with the using time and amounts of deflection and it may affect treatment outcomes. As the main reason for wire deflection, canine crown angulation plays an important role in the wire performance. It may be wise to focus on the canine crown angulations and using time in clinic with Tip-Edge Plus technique and make proper adjustment to help to make sure the treatment outcomes. 展开更多
关键词 Tip-Edge Plus archwires nickel-titanium three-point bending test crown angulation
原文传递
Phase transformation analysis of varied nickel-titanium orthodontic wires 被引量:1
7
作者 REN Chao-chao BAI Yu-xing +2 位作者 WANG Hong-mei ZHENG Yu-feng LI Song 《Chinese Medical Journal》 SCIE CAS CSCD 2008年第20期2060-2064,共5页
Background The shape memory effect of nickel-titanium (NiTi) archwires is largely determined by the phase transition temperature. It is associated with a reversible transformation from martensite to austenite. The a... Background The shape memory effect of nickel-titanium (NiTi) archwires is largely determined by the phase transition temperature. It is associated with a reversible transformation from martensite to austenite. The aim of this study was to characterize austenite, martensite and R phase temperatures as well as transition temperature ranges of the commonly used clinical NiTi orthodontic arch wires selected from several manufacturers. Methods Differential scanning calorimetry (DSC) method was used to study the phase transformation temperatures and the phase transition processes of 9 commonly used clinical NiTi alloys (types: 0.40 mm (0.016 inch), 0.40 mm × 0.56 mm (0.016 inch × 0.022 inch)).Results The austenite finish temperatures (Af) of 0.40 mm Smart, Ormco and 3M NiTi wires were lower than the room temperature, and no phase transformation was detected during oral temperature. Therefore, we predicted that these types of NiTi did not possess shape memory property. For 0.40 mm and 0.40 mm × 0.56 mm Youyan I NiTi wires, no phase transformation was detected during the scanning temperature range, suggesting that these two types of wires did not possess shape memory either. The Af of 0.40 mm × 0.56 mm Smart, L&H, Youyan II Ni-Ti wires were close to the oral temperature and presented as martensitic-austenitic structures at room temperature, suggesting the NiTi wires listed above have good shape memory effect. Although the 0.40 mm × 0.56 mm Damon CuNiTi wire showed martensitic- austenitic structures at oral temperature, its Af was much higher than the oral temperature. It means that transformation from martensite to austenite for this type of NiTi only finishes when oral temperature is above normal. Conclusion The phase transformation temperatures and transformation behavior varied among different commonly used NiTi orthodontic arch wires, leading to variability in shape memory effect. 展开更多
关键词 phase transformation nickel-titanium differential scanning calorimetry shape memory
原文传递
NIC X-FILE和DENCO Pre-Shaper镍钛器械对模拟弯曲根管成形的影响
8
作者 申煜荣 乃仁桐 +4 位作者 赵玲 刘飞刚 尹曹洋 顾远平 陈铁一 《中国组织工程研究》 CAS 北大核心 2024年第3期387-391,共5页
背景:根管预备是根管治疗的关键步骤,近年来随着新型镍钛器械的迅速发展,根管成形能力得到了显著提高,然而不同种类的镍钛系统成形能力亦不同,目前国内外关于R相热处理机用镍钛器械NIC X-FILE和DENCO Pre-Shaper对弯曲根管成形能力的影... 背景:根管预备是根管治疗的关键步骤,近年来随着新型镍钛器械的迅速发展,根管成形能力得到了显著提高,然而不同种类的镍钛系统成形能力亦不同,目前国内外关于R相热处理机用镍钛器械NIC X-FILE和DENCO Pre-Shaper对弯曲根管成形能力的影响鲜见报道。目的:比较NIC X-FILE和DENCO Pre-Shaper机用镍钛锉预备树脂模拟弯曲根管的成形效果。方法:选取树脂模拟弯曲根管50个,随机分为2组(n=25),分别使用NIC X-FILE、DENCO Pre-Shaper镍钛根管锉进行根管预备,记录根管预备时间、采集根管预备前后图像。使用图像处理和分析软件测量各观测点的根管内、外侧壁树脂去除量,运用统计学软件,对比研究两种机用镍钛锉的根管预备时间和中心定位能力。结果与结论:①DENCO Pre-Shaper组平均根管预备时间为(1.58±0.02)min,NIC X-FILE组平均根管预备时间为(2.22±0.03)min,两组间比较差异有显著性意义(P<0.05);②DENCO Pre-Shaper组在距离根尖孔4,5,7,8,9,10 mm处的内侧树脂去除量多于NIC X-FILE组(P<0.05),在距离根尖孔3,5,6,7,8 mm处的外侧树脂去除量少于NIC X-FILE组(P<0.05);③在距离根尖孔2,4,5,6,7,8,9 mm处,NIC X-FILE组的中心定位能力优于DENCO Pre-Shaper组(P<0.05),其中在距离根尖孔4 mm处的中心定位能力最佳;④结果表明,DENCO Pre-Shaper根管锉较NIC X-FILE镍钛根管锉具有较高的机械效率,但其中心定位能力不如NIC X-FILE镍钛根管锉。 展开更多
关键词 NIC X-FILE DENCO Pre-Shaper 根管预备 镍钛器械 根管预备时间 中心定位能力
下载PDF
2种机用镍钛器械在乳磨牙根管治疗中的临床效果观察
9
作者 史婷 邢晓华 《中国卫生标准管理》 2024年第11期18-21,共4页
目的探讨Reciproc机用镍钛器械和Protaper机用镍钛器械在乳磨牙根管治疗中的临床应用效果。方法选取2020年1月—2021年1月甘肃中医药大学附属医院口腔科就诊的乳牙牙髓病患儿50例,分别用Reciproc镍钛器械(RE组)和Protaper镍钛器械(PT组... 目的探讨Reciproc机用镍钛器械和Protaper机用镍钛器械在乳磨牙根管治疗中的临床应用效果。方法选取2020年1月—2021年1月甘肃中医药大学附属医院口腔科就诊的乳牙牙髓病患儿50例,分别用Reciproc镍钛器械(RE组)和Protaper镍钛器械(PT组)进行根管治疗。分别记录2组的根管预备时间、诊间疼痛评估值和术后X线片检查充填效果。所有的根管治疗操作均为同一医生进行。结果平均每根根管预备时间RE组为(3.70±1.19)min,PT组为(5.43±1.16)min,RE组的预备时间短于PT组,差异有统计学意义(P<0.05)。2组约诊间痛评分和根管充填效果比较,差异无统计学意义(P>0.05)。结论机用镍钛器械Protaper和Reciproc在乳牙根管治疗时具有预备时间短、诊间疼痛反应低、充填效果佳的优点,其中Reciproc在治疗操作时间方面优于Protaper。 展开更多
关键词 Reciproc镍钛机械 PROTAPER镍钛器械 根管治疗 乳磨牙 诊间疼痛 根管预备时间
下载PDF
钛镍记忆合金线分次牵张联合负压封闭引流修复慢性下肢皮肤缺损创面
10
作者 朱召银 林育林 +3 位作者 黄伍良 陈为坚 王婷 陈荣恒 《中国骨科临床与基础研究杂志》 2024年第1期21-25,共5页
目的探讨钛镍记忆合金线分次牵张联合负压封闭引流(VSD)修复慢性下肢皮肤缺损创面的治疗效果。方法回顾性分析2019年6月至2022年12月广州医科大学附属第五医院应用钛镍记忆合金线分次牵拉联合VSD修复30例慢性下肢小面积全层皮肤缺损创... 目的探讨钛镍记忆合金线分次牵张联合负压封闭引流(VSD)修复慢性下肢皮肤缺损创面的治疗效果。方法回顾性分析2019年6月至2022年12月广州医科大学附属第五医院应用钛镍记忆合金线分次牵拉联合VSD修复30例慢性下肢小面积全层皮肤缺损创面患者的临床资料。创面缺损面积1.5cm×2.0cm~3.0cm×13.0 cm,观察患者术后伤口愈合情况,记录并发症及随访结果。结果住院时间8~35 d(平均16.8 d);所有患者伤口愈合均良好,愈合时间19~31 d(平均24.5 d),外观良好;术后和随访期间未出现创面裂开或感染。结论钛镍记忆合金线分次牵张联合VSD治疗一期无法缝合的下肢小面积皮肤全层缺损慢性创面简便有效,具有愈合时间短、外观良好等优点。 展开更多
关键词 下肢 皮肤 创伤和损伤 慢性病 形状记忆合金 缝线 负压伤口疗法 伤口愈合
下载PDF
不同镍钛器械在磨牙弯曲根管中的应用效果比较
11
作者 周冬燕 董佳增 蔡琪 《中国现代医生》 2024年第14期53-56,共4页
目的探析Waveone Gold、Protaper、MTwo及Reciproc 4种不同镍钛器械在磨牙弯曲根管中的应用效果。方法收集100颗弯曲离体磨牙,采用随机数字表法分为五组,分别使用Waveone Gold、Protaper、Reciproc、MTwo和不锈钢K锉进行根管预备。比较... 目的探析Waveone Gold、Protaper、MTwo及Reciproc 4种不同镍钛器械在磨牙弯曲根管中的应用效果。方法收集100颗弯曲离体磨牙,采用随机数字表法分为五组,分别使用Waveone Gold、Protaper、Reciproc、MTwo和不锈钢K锉进行根管预备。比较五组根管预备效果及相关并发症、根管偏移量、根管充填效果。结果五组根管预备时间比较,差异有统计学意义(P<0.05),以Waveone Gold组根管预备时间最短;五组台阶形成发生率比较,差异有统计学意义(P<0.05),五组根管侧穿、器械折断发生率比较,差异无统计学意义(P>0.05)。五组2mm、4mm及6mm垂直平面根管偏移量较小,差异有统计学意义(P<0.05),以Waveone Gold组根管偏移量最小。五组超充率比较,差异无统计学意义(P>0.05)。五组恰充及欠充率比较,差异有统计学意义(P<0.05),其中Waveone Gold组、Reciproc组恰充率均高于对照组,欠充率均低于对照组(P<0.05)。结论磨牙弯曲根管应用镍钛器械可缩短根管预备时间,相关并发症少、根管偏移量小、根管充填效果佳,尤以Waveone Gold具有明显优势。 展开更多
关键词 磨牙弯曲根管 WaveOne Gold 根管预备 机用镍钛器械
下载PDF
不同陶瓷颗粒表面处理对陶瓷/高铬铸铁复合材料微观界面的影响
12
作者 汪勇 余申卫 +3 位作者 刘春溪 魏昂 王成辉 王惠梅 《热加工工艺》 北大核心 2024年第5期142-146,共5页
采用传统的高铬铸铁制备电厂用磨煤机磨辊、磨盘已无法满足耐磨需求,陶瓷颗粒增强金属基耐磨复合材料成为替代传统耐磨材料的首选。本文研究了镀镍、镀钛表面处理对陶瓷/高铬铸铁复合材料微观界面的影响。结果表明,表面处理后陶瓷与高... 采用传统的高铬铸铁制备电厂用磨煤机磨辊、磨盘已无法满足耐磨需求,陶瓷颗粒增强金属基耐磨复合材料成为替代传统耐磨材料的首选。本文研究了镀镍、镀钛表面处理对陶瓷/高铬铸铁复合材料微观界面的影响。结果表明,表面处理后陶瓷与高铬铸铁界面润湿性改善,可获得较好的铸渗效果。镀镍陶瓷颗粒与高铬铸铁复合材料没有明显的中间过渡层,二者之间的结合强度不高,陶瓷与高铬铸铁结合为机械结合。镀钛陶瓷颗粒与高铬铸铁复合材料的界面由于Ti元素的作用发生化学反应,形成明显的中间过渡层,界面结合强度高,陶瓷与高铬铸铁结合为冶金结合。 展开更多
关键词 镀镍 镀钛 ZTA陶瓷 高铬铸铁 界面结合
下载PDF
SB-265 Gr.12钛镍钼合金焊接工艺研究
13
作者 刘玉祥 叶旭东 《电站辅机》 2024年第1期42-48,共7页
介绍了SB-265 Gr.12钛镍钼合金的化学成分与力学性能,对化学成分中各元素的作用进行了阐述,并对SB-265 Gr.12钛镍钼合金的焊接性以及焊接注意事项进行了介绍。工艺评定试验采用24 mm厚的SB-265 Gr.12板材,焊接采用钨极惰性气体保护焊(GT... 介绍了SB-265 Gr.12钛镍钼合金的化学成分与力学性能,对化学成分中各元素的作用进行了阐述,并对SB-265 Gr.12钛镍钼合金的焊接性以及焊接注意事项进行了介绍。工艺评定试验采用24 mm厚的SB-265 Gr.12板材,焊接采用钨极惰性气体保护焊(GTAW)焊接方法。焊接工艺评定试板经渗透检测(PT)、射线检测(RT)检测合格后,进行拉伸、弯曲、硬度等理化试验,试验结果满足标准及相关工程规范的要求。对焊接接头进行宏观金相及显微组织试验,宏观金相试验结果良好,母材的显微组织为α相+少量β相,基体上弥散分布着Ni_(2)Ti相,焊接热影响区的显微组织为α相+少量β相+Ni_(2)Ti相+片层状α’相,焊缝的显微组织为片层状的α’相+少量β相。 展开更多
关键词 SB-265 Gr.12 钛镍钼合金 焊接 钨极惰性气体保护焊 试验 显微组织
下载PDF
前处理及热处理对钛合金化学镀镍层性能影响的研究
14
作者 胡波 《工程与试验》 2024年第2期43-46,共4页
为满足新一代战机对减重的要求,钛合金作动筒正逐步替代传统的钢制作动筒。为提升钛合金表面硬度,增强其耐磨性能,开展了钛合金化学镀镍工艺研究,探索不同前处理及热处理方式对镀层性能指标的影响。采用硬度测试仪、扫描电镜、能谱测试... 为满足新一代战机对减重的要求,钛合金作动筒正逐步替代传统的钢制作动筒。为提升钛合金表面硬度,增强其耐磨性能,开展了钛合金化学镀镍工艺研究,探索不同前处理及热处理方式对镀层性能指标的影响。采用硬度测试仪、扫描电镜、能谱测试仪等对镀镍后TC6钛合金的硬度、厚度、表面形貌、结合力、膜层成分及含氢量进行了检测分析。结果表明,前处理采用低压吹细砂+氢氟酸腐蚀活化,得到结合力良好的Ni-P合金镀层,镀层硬度在各个温度区间内分布均匀且随着温度升高而提升,真空炉399℃热处理,硬度可达900HV,含氢量为104.28ppm,满足产品使用需求。 展开更多
关键词 TC6钛合金 前处理 化学镀镍 真空热处理
下载PDF
Surface nanostructures orienting self-protection of an orthodontic nickel-titanium shape memory alloys wire 被引量:4
15
作者 NIE Qiong JI ZhuoYu +1 位作者 LIN JiuXiang HU WenPing 《Chinese Science Bulletin》 SCIE EI CAS 2007年第21期3020-3023,共4页
Shape memory alloys (SMA) have been applied to a wide variety of applications in a number of different fields such as aeronautical applications, sensors/actuators, medical sciences as well as orthodontics. It is a hot... Shape memory alloys (SMA) have been applied to a wide variety of applications in a number of different fields such as aeronautical applications, sensors/actuators, medical sciences as well as orthodontics. It is a hot topic to enhance the anti-corrosion ability of orthodontic wires for clinical applications. In this letter, a very nice fractal structure, micro-domains with identical nanometer sized grooves, was ob- tained on the surfaces of the orthodontic wires with an oxygen plasma and acid corrosion. The concave parts of the grooves were dominated by titanium and convex parts were the same as the bulk wires. The micro-nano fractal structure generated a hydrophobic surface with the largest contact angle to water being about 157°. The titanium dominated nanolayer and the hydrophobicity of the surface resulted in jointly the great improvement of the anti-corrosion ability of the orthodontic wires. Because the fractal structures of the wires were formed automatically when they immersed in acidic environment, hence, the self-protection of the oxygen plasma-treated orthodontic wires in acidic environment indicates their potential applications in orthodontics, and should be also inspirable for other applications of SMA materials. 展开更多
关键词 口腔正畸学 定型器材 合金线 临床研究
原文传递
激光功率对汽车活塞销轴表面Ni-TiN涂层组织结构和性能的影响
16
作者 王斌 徐律 张晓明 《电镀与涂饰》 CAS 北大核心 2023年第22期8-14,共7页
采用激光熔覆沉积法在汽车活塞销轴常用的40Cr钢表面制备了Ni–TiN涂层,利用扫描电子显微镜(SEM)、X射线衍射仪(XRD)、显微硬度计、抗剪强度试验机、摩擦磨损试验机等设备研究了激光功率(1.0、1.5和2.0 kW)对Ni–TiN涂层表面形貌、物相... 采用激光熔覆沉积法在汽车活塞销轴常用的40Cr钢表面制备了Ni–TiN涂层,利用扫描电子显微镜(SEM)、X射线衍射仪(XRD)、显微硬度计、抗剪强度试验机、摩擦磨损试验机等设备研究了激光功率(1.0、1.5和2.0 kW)对Ni–TiN涂层表面形貌、物相组成、显微硬度、抗剪强度及耐磨性的影响。结果表明:当激光功率为1.5 kW时,Ni–TiN涂层组织结构均匀、致密,颗粒细化程度最高,因此其显微硬度和抗剪强度最高,分别约为843.2 HV和802.8 MPa,在摩擦磨损试验中的摩擦因数最小(平均值为0.44)。 展开更多
关键词 氮化钛 复合涂层 激光熔覆 功率 抗剪强度 微观形貌 摩擦因数
下载PDF
增材制造金属材料各向异性的研究现状
17
作者 陈靓瑜 秦博渊 +2 位作者 褚宇航 郑传波 姚增健 《江苏科技大学学报(自然科学版)》 CAS 北大核心 2023年第3期18-23,共6页
近年来,人们利用增材制造这项高性能、高效率、低成本的高潜力技术制造出了许多传统工艺制造不出的复杂零件.但是,由于增材制造技术和扫描策略的不同,采用增材制造技术制备的样品在微观结构和力学性能上具有三维各向异性.文中通过对不... 近年来,人们利用增材制造这项高性能、高效率、低成本的高潜力技术制造出了许多传统工艺制造不出的复杂零件.但是,由于增材制造技术和扫描策略的不同,采用增材制造技术制备的样品在微观结构和力学性能上具有三维各向异性.文中通过对不同增材制造技术的特点进行对比,从而讨论其生产出的不同金属样品组织和性能的区别,通过对组织的分析来探索其性能上的差异,进一步了解样品的各向异性,并简要说明他们之间的差异.最后,根据目前的研究成果,提出了未来研究还需解决的问题. 展开更多
关键词 增材制造 微观组织 各向异性 钛合金 镍基合金
下载PDF
氮化钛镀层和镍镀层钕铁硼磁环的生物相容性实验研究
18
作者 张苗苗 任宇翔 +4 位作者 王伊睿 孙宛婧 白纪刚 吕毅 严小鹏 《医疗卫生装备》 CAS 2023年第6期31-35,共5页
目的:通过体内外实验评价氮化钛镀层和镍镀层表面改性后的钕铁硼磁环的生物相容性,为血管磁吻合装置的表面改性方法提供参考。方法:各取3个氮化钛镀层和镍镀层钕铁硼磁环,采用视频光学接触角测量仪测试其接触角;将氮化钛镀层和镍镀层钕... 目的:通过体内外实验评价氮化钛镀层和镍镀层表面改性后的钕铁硼磁环的生物相容性,为血管磁吻合装置的表面改性方法提供参考。方法:各取3个氮化钛镀层和镍镀层钕铁硼磁环,采用视频光学接触角测量仪测试其接触角;将氮化钛镀层和镍镀层钕铁硼磁环分别植入SD大鼠肌肉和腹腔组织内,3个月后获取磁环周围组织进行HE和Masson染色,以SD大鼠正常肌肉组织及大网膜病理切片为对照进行组织学观察;采用体外溶血实验以及血小板黏附实验比较氮化钛镀层和镍镀层钕铁硼磁环的溶血率和血小板黏附情况。结果:氮化钛镀层和镍镀层磁环的接触角均大于90°,均表现出疏水特性;2种镀层磁环在SD大鼠体内留置3个月后,磁环周围的肌肉组织和腹膜组织未见明显炎症细胞浸润及组织异物反应;氮化钛镀层和镍镀层磁环的溶血率分别为0.23%和0.84%,氮化钛镀层磁环的溶血率优于镍镀层磁环;镍镀层磁环表面的血小板聚集量明显多于氮化钛镀层磁环,且血小板伪足生长也更为明显。结论:氮化钛镀层钕铁硼磁环生物相容性优于镍镀层钕铁硼磁环,氮化钛镀层更适合用于血管磁吻合装置的表面改性。 展开更多
关键词 钕铁硼 磁环 氮化钛镀层 镍镀层 生物相容性 表面改性 磁吻合
下载PDF
激光选区熔化成形技术在航空航天发动机制造领域的研究与应用现状 被引量:6
19
作者 张海洲 白洁 +1 位作者 马瑞 王栋 《推进技术》 EI CAS CSCD 北大核心 2023年第3期1-16,共16页
本文重点介绍了激光选区熔化(Selective Laser Melting,SLM)成形钛合金、镍基高温合金、铜合金等材料体系的研究进展,以及SLM装备与工艺新技术;同时综述了国内外SLM技术在航空航天发动机领域的典型应用;最后在分析现有相关研究和应用的... 本文重点介绍了激光选区熔化(Selective Laser Melting,SLM)成形钛合金、镍基高温合金、铜合金等材料体系的研究进展,以及SLM装备与工艺新技术;同时综述了国内外SLM技术在航空航天发动机领域的典型应用;最后在分析现有相关研究和应用的基础上,讨论了SLM技术面临的挑战和未来重点研究方向。 展开更多
关键词 激光选区熔化(SLM) 发动机 钛合金 镍基高温合金 铜合金 综述
下载PDF
形状记忆弓齿钉与下胫腓固定螺钉治疗Maisonneuve骨折的疗效对比
20
作者 罗一林 崔进 +2 位作者 谢杨 商艳 年申生 《海军军医大学学报》 CAS CSCD 北大核心 2023年第11期1361-1365,共5页
目的比较镍钛形状记忆弓齿钉和下胫腓固定螺钉治疗Maisonneuve骨折(MFF)的疗效。方法回顾性收集2019年1月至2021年12月我院收治的33例MFF患者的临床资料,根据治疗方法,将患者分为形状记忆合金弓齿钉治疗组(弓齿钉治疗组,13例)和下胫腓... 目的比较镍钛形状记忆弓齿钉和下胫腓固定螺钉治疗Maisonneuve骨折(MFF)的疗效。方法回顾性收集2019年1月至2021年12月我院收治的33例MFF患者的临床资料,根据治疗方法,将患者分为形状记忆合金弓齿钉治疗组(弓齿钉治疗组,13例)和下胫腓固定螺钉治疗组(螺钉组,20例)。比较两组患者的手术时间及术中出血量,末次随访时按照美国骨科足踝外科医师协会(AOFAS)评分标准对手术效果进行评价。结果弓齿钉治疗组和螺钉组患者的手术时间[(118.46±19.55)min vs(113.50±17.97)min]、术中出血量[(90.77±53.85)mL vs(94.50±46.53)mL]差异无统计学意义(P均>0.05)。两组患者术后切口均一期愈合,无皮肤坏死、切口感染等局部并发症。两组患者术后均随访6~24个月,平均随访时间为(14.70±5.20)个月。末次随访时,两组患者的AOFAS踝关节功能总体评估得分及踝关节症状评价得分差异均无统计学意义(P均>0.05)。结论镍钛形状记忆合金弓齿钉及下胫腓固定螺钉处理MFF中下胫腓联合损伤均能达到满意效果,但镍钛形状记忆合金弓齿钉不仅能保留踝关节及下胫腓联合的生理活动,且负重前无须常规取出,是一种值得推广的治疗方法。 展开更多
关键词 MAISONNEUVE骨折 下胫腓联合 骨折固定术 镍钛记忆合金
下载PDF
上一页 1 2 51 下一页 到第
使用帮助 返回顶部