We review the short-circuit testing of distribution and power transformers, and include a list of 110-220kV power transformers tested up to February 2002.
Partial discharge test on a transformer is carried out according to the items in IEC 60. During the test, unproved measuring system is calibrated by proved system at a voltage no less than 50% the rated testing voltag...Partial discharge test on a transformer is carried out according to the items in IEC 60. During the test, unproved measuring system is calibrated by proved system at a voltage no less than 50% the rated testing voltage. The result is then extrapolated linearly, leading to an error related to the distribution of stray capacitance, which varies with the testing frequency, especially to large transformers. In this paper a factor, named the capacitive rise fact, is introduced to assess the rise. The factor can be adjusted to some extent by changing the reactance that is connected to the LV side of the testing circuit to lower the capacity of the power source. However, the factor changes when the voltage divider on the high voltage side is removed after the voltage ratio has been calculated, and a great error is resulted under unfavorable conditios.展开更多
1 Development of UHVDC transmission capabilities The economical development of China is closely connected with safe and reliable power supply.Load centers e.g.in central and eastern China need huge amounts of electric...1 Development of UHVDC transmission capabilities The economical development of China is closely connected with safe and reliable power supply.Load centers e.g.in central and eastern China need huge amounts of electrical power.Available energy resources and consumption areas are often distributed inverse.As a consequence it is necessary to import electrical power to load center areas in an economic and efficient way.展开更多
The large transformer is pivotal equipment in an electric power supply system; Its partial discharge test and the induced voltage withstand test on large transformers are carried out at a frequency about twice the wor...The large transformer is pivotal equipment in an electric power supply system; Its partial discharge test and the induced voltage withstand test on large transformers are carried out at a frequency about twice the working frequency. If the magnetizing inductance cannot compensate for the stray capacitance, the test sample turns into a capacitive load and a capacitive rise exhibits in the testing circuit. For self-restoring insulation, a method has been recommended in IEC60-1 that an unapproved measuring system be calibrated by an approved system at a voltage not less than 50% of the rated testing voltage, and the result then be extrapolated linearly. It has been found that this method leads to great error due to the capacitive rise if it is not correctly used during a withstand voltage test under certain testing conditions, especiaUy for a test on high voltage transformers with large capacity. Since the withstand voltage test is the most important means to examine the operation reliability of a transformer, and it can be destructive to the insulation, a precise measurement must be guaranteed. In this paper a factor, named as the capacitive rise factor, is introduced to assess the rise. The voltage measurement error during the calibration is determined by the parameters of the test sample and the testing facilities, as well as the measuring point. Based on theoretical analysis in this paper, a novel method is suggested and demonstrated to estimate the error by using the capacitive rise factor and other known parame- ters of the testing circuit.展开更多
In this paper, a method to calculate the slope of the ratio restraint characteristic of a transformer differential relay protection is proposed. The method allows using some concise but effective means to get the slop...In this paper, a method to calculate the slope of the ratio restraint characteristic of a transformer differential relay protection is proposed. The method allows using some concise but effective means to get the slope. Modulating the argument of current output from ONLLY testing equipment can make the relay protection device operate, thus, the data used for calculation would be obtained naturally after several trails. In order to make sure how effective that method could be, some experiment data is given as well.展开更多
This paper analyzes characteristics of multi type current transformers hybrid operation for each branch of the bus and their effects on differential protection of the bus. By theoretically analyzing transmission chara...This paper analyzes characteristics of multi type current transformers hybrid operation for each branch of the bus and their effects on differential protection of the bus. By theoretically analyzing transmission characteristics of multi type current transformers and their influence factors, we study the dynamic model testing method of multi type current transformers for the bus, and design 3 kinds of testing schemes by making the equivalent model based on the field of P-level current transformer, TPY-level current transformer and electronic current transformer, and build the hybrid operation testing platform of multi type current transformers. Finally, we compare and analyze the transmission characteristics difference of multi type current transformers on the same branch and the characteristics difference of hybrid operation in two successive external faults, analyze the cause behind the differences, and put forward the corresponding improvement measures.展开更多
To obtain the phase transformation latent heat corresponding to different cooling rates with low test workload and cost,the Newton thermal analysis method and the improved Newtonian thermal analysis method were discus...To obtain the phase transformation latent heat corresponding to different cooling rates with low test workload and cost,the Newton thermal analysis method and the improved Newtonian thermal analysis method were discussed based on the cooling curve obtained in the end-quench test.The validity of two methods was given by the latent heat calculation of 45^(#) steel.The results show that the relative error of latent heat is 5.20%through the improved Newtonian thermal analysis method,which is more accurate than the Newtonian thermal analysis method.Furthermore,the latent heat release of phase transformation of the self-designed CSU-A1 powder metallurgy nickel-based superalloy increases from 4.3 to 12.29 J/g when the cooling rate decreases from 50.15 to 33.40℃/min,because there is more sufficient time for the alloy microstructure to complete the phase transformation process when the cooling rate is smaller.展开更多
Background: When continuous scale measurements are available, agreements between two measuring devices are assessed both graphically and analytically. In clinical investigations, Bland and Altman proposed plotting sub...Background: When continuous scale measurements are available, agreements between two measuring devices are assessed both graphically and analytically. In clinical investigations, Bland and Altman proposed plotting subject-wise differences between raters against subject-wise averages. In order to scientifically assess agreement, Bartko recommended combining the graphical approach with the statistical analytic procedure suggested by Bradley and Blackwood. The advantage of using this approach is that it enables significance testing and sample size estimation. We noted that the direct use of the results of the regression is misleading and we provide a correction in this regard. Methods: Graphical and linear models are used to assess agreements for continuous scale measurements. We demonstrate that software linear regression results should not be readily used and we provided correct analytic procedures. The degrees of freedom of the F-statistics are incorrectly reported, and we propose methods to overcome this problem by introducing the correct analytic form of the F statistic. Methods for sample size estimation using R-functions are also given. Results: We believe that the tutorial and the R-codes are useful tools for testing and estimating agreement between two rating protocols for continuous scale measurements. The interested reader may use the codes and apply them to their available data when the issue of agreement between two raters is the subject of interest.展开更多
Despite the importance of aloe in cosmetic and pharmaceutical industries, improvement of aloe (Aloe barbadensis Miller) by genetic engineering was seldom reported previously. In this study, regeneration and transfor...Despite the importance of aloe in cosmetic and pharmaceutical industries, improvement of aloe (Aloe barbadensis Miller) by genetic engineering was seldom reported previously. In this study, regeneration and transformation conditions, including explant selection and surface sterilization, use of different Agrobacterium strains, and co-culture processing, are optimized. The use of 20.0% sodium hypochloride (25 rain) for sterilization was less detrimental to the health of explant than 0.1% mercuric chloride (10 min). Regeneration frequency from stems was much higher than that from leaves or sheaths. Explants were infected by Agrobacterium (30 rain) in liquid co-cultural medium, and this was followed by three days co-culture on sterile filter papers with light for 10 h per day at 24℃. Histochemical data demonstrated that the transient expression of GUS gene in the stem explants of aloe infected with Agrobacterium strains EHAI05 and C58CI was 80.0% and 30.0%, respectively, suggesting the higher sensitivity of the explants to EHAI05 than to C58C1. Infected tissues were selected using G418 (10.0-25.0 mg/L) to generate transformants. Sixty-seven G418 resistant plantlets were generated from the infected explants. Southern blotting, PCR, and ELISA analyses indicated that the alien gene were successfully transferred into aloe and was expressed in the transgenic plants. This newly established transformation system could be used for the genetic improvement of aloe.展开更多
Traditional modal parameter identifi cation methods have many disadvantages,especially when used for processing nonlinear and non-stationary signals.In addition,they are usually not able to accurately identify the dam...Traditional modal parameter identifi cation methods have many disadvantages,especially when used for processing nonlinear and non-stationary signals.In addition,they are usually not able to accurately identify the damping ratio and damage.In this study,methods based on the Hilbert-Huang transform(HHT) are investigated for structural modal parameter identifi cation and damage diagnosis.First,mirror extension and prediction via a radial basis function(RBF) neural network are used to restrain the troublesome end-effect issue in empirical mode decomposition(EMD),which is a crucial part of HHT.Then,the approaches based on HHT combined with other techniques,such as the random decrement technique(RDT),natural excitation technique(NExT) and stochastic subspace identifi cation(SSI),are proposed to identify modal parameters of structures.Furthermore,a damage diagnosis method based on the HHT is also proposed.Time-varying instantaneous frequency and instantaneous energy are used to identify the damage evolution of the structure.The relative amplitude of the Hilbert marginal spectrum is used to identify the damage location of the structure.Finally,acceleration records at gauge points from shaking table testing of a 12-story reinforced concrete frame model are taken to validate the proposed approaches.The results show that the proposed approaches based on HHT for modal parameter identifi cation and damage diagnosis are reliable and practical.展开更多
Eddy current pulsed thermography(ECPT) is an emerging Non-destructive testing and evaluation(NDT E) technique, which uses hybrid eddy current and thermography NDT E techniques that enhances the detectability fro...Eddy current pulsed thermography(ECPT) is an emerging Non-destructive testing and evaluation(NDT E) technique, which uses hybrid eddy current and thermography NDT E techniques that enhances the detectability from their compensation. Currently, this technique is limited by the manual selection of proper contrast frames and the issue of improving the efficiency of defect detection of complex structure samples remains a challenge. In order to select a specific frame from transient thermal image sequences to maximize the contrast of thermal variation and defect pattern from complex structure samples, an energy driven approach to compute the coefficient energy of wavelet transform is proposed which has the potential of automatically selecting both optimal transient frame and spatial scale for defect detection using ECPT. According to analysis of the variation of different frequency component and the comparison study of the detection performance of different scale and wavelets, the frame at the end of heating phase is automatically selected as an optimal transient frame for defect detection. In addition, the detection capabilities of the complex structure samples can be enhanced through proper spatial scale and wavelet selection. The proposed method has successfully been applied to low speed impact damage detection of carbon fibre reinforced polymer(CFRP) composite as well as providing the guidance to improve the detectability of ECPT technique.展开更多
Gravity retaining wall with geogrids has showed excellent seismic performance from Wenchuan great earthquake.However,seismic damage mechanism of this kind of wall is not sufficiently clear.In view of this,a large shak...Gravity retaining wall with geogrids has showed excellent seismic performance from Wenchuan great earthquake.However,seismic damage mechanism of this kind of wall is not sufficiently clear.In view of this,a large shaking table test of the gravity retaining wall with geogrids to reinforce the subgrade slope was carried out,and based on the HilbertHuang transform and the marginal spectrum theory,the energy identification method of the slope dynamic failure mode was studied.The results show that the geogrids can effectively reduce displacement and rotation of the retaining wall,and it can effectively absorb the energy of the ground movement when combined with the surrounding soil.In addition,it also reveals the failure development of the gravity retaining wall with geogrids to reinforce the subgrade slope.The damage started in the deep zone near the geogrids,and then gradually extended to the surface of the subgrade slope and other zones,finally formed a continuous failure surface along the geogrids.The analysis results of the failure mode identified by the Hilbert marginal spectrum are in good consistency with the experimental results,which prove that the Hilbert marginal spectrum can be applied to obtain the seismic damage mechanism of slope.展开更多
The digital testing technique based on computers for dynamic characteristics of electrohydraulic servovalves via frequency scan method is researched. The no-load piston which measures the servo's transient output ...The digital testing technique based on computers for dynamic characteristics of electrohydraulic servovalves via frequency scan method is researched. The no-load piston which measures the servo's transient output flow is designed properly. The velocity testing method by which the speed signal can be obtained indirectly by means of a piezoelectral accelerometer is given. High speed sampling has been realized in Windows OS. Wavelet denoising and Fourier transform are adopted in data processing and analyses. The testing technique discussed has been applied to actual testing systems and the experimental results have proved it to be correct.展开更多
In the present paper, the authors introduce a new integral transform which yields a number of potentially useful (known or new) integral transfoms as its special cases. Many fundamental results about this new integr...In the present paper, the authors introduce a new integral transform which yields a number of potentially useful (known or new) integral transfoms as its special cases. Many fundamental results about this new integral transform, which are established in this paper, in- clude (for example) existence theorem, Parseval-type relationship and inversion formula. The relationship between the new integral transform with the H-function and the H-transform are characterized by means of some integral identities. The introduced transform is also used to find solution to a certain differential equation. Some illustrative examples are also given.展开更多
The high-rise frame structure has become more and more widespread, like its damage from the complication of the environment. The traditional method of damage detection, which is only suitable for the stationary signal...The high-rise frame structure has become more and more widespread, like its damage from the complication of the environment. The traditional method of damage detection, which is only suitable for the stationary signal, does not apply to a high-rise frame structure because its damage signal is non-stationary. Thus, this paper presents an application of the short-time Fourier transform(STFT) to damage detection of high-rise frame structures. Compared with the fast Fourier transform, STFT is found to be able to express the frequency spectrum property of the time interval using the signal within this interval. Application of STFT to analyzing a Matlab model and the shaking table test with a twelve-story frame-structure model reveals that there is a positive correlation between the slope of the frequency versus time and the damage level. If the slope is equal to or greater than zero, the structure is not damaged. If the slope is smaller than zero, the structure is damaged, and the less the slope is, the more serious the damage is. The damage results from calculation based on the Matlab model are consistent with those from the shaking table test, demonstrating that STFT can be a reliable tool for the damage detection of high-rise frame structures.展开更多
A new online system of monitoring yarn quality and fault diagnosis is presented. This system integrates the technologies of sensor, signal process, communication, network, computer, control, instrument structure and m...A new online system of monitoring yarn quality and fault diagnosis is presented. This system integrates the technologies of sensor, signal process, communication, network, computer, control, instrument structure and mass knowledge of experts. Comparing with conventional off-line yarn test, the new system can find the quality defects of yarn online in time and compensate for the lack of expert knowledge in manual analysis. It can save a lot of yarn wasted in off-line test and improve product quality. By using laser sensor to sample the diameter signal of yarn and doing wavelet analysis and FFT to extract fault characteristics, a set of reasoning mechanism is established to analyze yarn quality and locate the fault origination. The experimental results show that new system can do well in monitoring yarn quality online comparing with conventional off-line yarn test. It can test the quality of yarn in real-time with high efficiency and analyze the fault reason accurately. It is very useful to apply this new system to upgrade yarn quality in cotton textile industry at present.展开更多
Transformation plasticity is known to play an important role in the course of heat treatment processes, and so affect the results of heat treatment simulations, which means that the transformation plasticity coefficie...Transformation plasticity is known to play an important role in the course of heat treatment processes, and so affect the results of heat treatment simulations, which means that the transformation plasticity coefficient is necessary to be identifies. The authors developed a new method by use of four-point bending system of a beam to identify transformation plasticity coefficient taking advantage of its easiness and high accuracy compared with other conventional methods like tension test, etc., and identified the coefficient for four kinds of steels; plane carbon steel, Cr-steel, Cr-Mo steel and bearing steel. In this paper, further experimental data are presented for the steels if the coefficient Kp during pearlite transformation depend on the applied stress. Obtained results reveals that the stress dependence of Kp is rather trivial except for uncertain tendency detected in plane carbon steel. The relation between the Kp and carbon content included is discussed in comparison with other data referred from references.展开更多
文摘We review the short-circuit testing of distribution and power transformers, and include a list of 110-220kV power transformers tested up to February 2002.
文摘Partial discharge test on a transformer is carried out according to the items in IEC 60. During the test, unproved measuring system is calibrated by proved system at a voltage no less than 50% the rated testing voltage. The result is then extrapolated linearly, leading to an error related to the distribution of stray capacitance, which varies with the testing frequency, especially to large transformers. In this paper a factor, named the capacitive rise fact, is introduced to assess the rise. The factor can be adjusted to some extent by changing the reactance that is connected to the LV side of the testing circuit to lower the capacity of the power source. However, the factor changes when the voltage divider on the high voltage side is removed after the voltage ratio has been calculated, and a great error is resulted under unfavorable conditios.
文摘1 Development of UHVDC transmission capabilities The economical development of China is closely connected with safe and reliable power supply.Load centers e.g.in central and eastern China need huge amounts of electrical power.Available energy resources and consumption areas are often distributed inverse.As a consequence it is necessary to import electrical power to load center areas in an economic and efficient way.
文摘The large transformer is pivotal equipment in an electric power supply system; Its partial discharge test and the induced voltage withstand test on large transformers are carried out at a frequency about twice the working frequency. If the magnetizing inductance cannot compensate for the stray capacitance, the test sample turns into a capacitive load and a capacitive rise exhibits in the testing circuit. For self-restoring insulation, a method has been recommended in IEC60-1 that an unapproved measuring system be calibrated by an approved system at a voltage not less than 50% of the rated testing voltage, and the result then be extrapolated linearly. It has been found that this method leads to great error due to the capacitive rise if it is not correctly used during a withstand voltage test under certain testing conditions, especiaUy for a test on high voltage transformers with large capacity. Since the withstand voltage test is the most important means to examine the operation reliability of a transformer, and it can be destructive to the insulation, a precise measurement must be guaranteed. In this paper a factor, named as the capacitive rise factor, is introduced to assess the rise. The voltage measurement error during the calibration is determined by the parameters of the test sample and the testing facilities, as well as the measuring point. Based on theoretical analysis in this paper, a novel method is suggested and demonstrated to estimate the error by using the capacitive rise factor and other known parame- ters of the testing circuit.
文摘In this paper, a method to calculate the slope of the ratio restraint characteristic of a transformer differential relay protection is proposed. The method allows using some concise but effective means to get the slope. Modulating the argument of current output from ONLLY testing equipment can make the relay protection device operate, thus, the data used for calculation would be obtained naturally after several trails. In order to make sure how effective that method could be, some experiment data is given as well.
文摘This paper analyzes characteristics of multi type current transformers hybrid operation for each branch of the bus and their effects on differential protection of the bus. By theoretically analyzing transmission characteristics of multi type current transformers and their influence factors, we study the dynamic model testing method of multi type current transformers for the bus, and design 3 kinds of testing schemes by making the equivalent model based on the field of P-level current transformer, TPY-level current transformer and electronic current transformer, and build the hybrid operation testing platform of multi type current transformers. Finally, we compare and analyze the transmission characteristics difference of multi type current transformers on the same branch and the characteristics difference of hybrid operation in two successive external faults, analyze the cause behind the differences, and put forward the corresponding improvement measures.
基金the financial supports from the National Key Research and Development Program of China(No.2016YFB0700300)the Postgraduate Independent Exploration and Innovation Project of Central South University,China(No.2019zzts262)。
文摘To obtain the phase transformation latent heat corresponding to different cooling rates with low test workload and cost,the Newton thermal analysis method and the improved Newtonian thermal analysis method were discussed based on the cooling curve obtained in the end-quench test.The validity of two methods was given by the latent heat calculation of 45^(#) steel.The results show that the relative error of latent heat is 5.20%through the improved Newtonian thermal analysis method,which is more accurate than the Newtonian thermal analysis method.Furthermore,the latent heat release of phase transformation of the self-designed CSU-A1 powder metallurgy nickel-based superalloy increases from 4.3 to 12.29 J/g when the cooling rate decreases from 50.15 to 33.40℃/min,because there is more sufficient time for the alloy microstructure to complete the phase transformation process when the cooling rate is smaller.
文摘Background: When continuous scale measurements are available, agreements between two measuring devices are assessed both graphically and analytically. In clinical investigations, Bland and Altman proposed plotting subject-wise differences between raters against subject-wise averages. In order to scientifically assess agreement, Bartko recommended combining the graphical approach with the statistical analytic procedure suggested by Bradley and Blackwood. The advantage of using this approach is that it enables significance testing and sample size estimation. We noted that the direct use of the results of the regression is misleading and we provide a correction in this regard. Methods: Graphical and linear models are used to assess agreements for continuous scale measurements. We demonstrate that software linear regression results should not be readily used and we provided correct analytic procedures. The degrees of freedom of the F-statistics are incorrectly reported, and we propose methods to overcome this problem by introducing the correct analytic form of the F statistic. Methods for sample size estimation using R-functions are also given. Results: We believe that the tutorial and the R-codes are useful tools for testing and estimating agreement between two rating protocols for continuous scale measurements. The interested reader may use the codes and apply them to their available data when the issue of agreement between two raters is the subject of interest.
基金the grant from Beijing Education Committee (No. KZ200410011006).
文摘Despite the importance of aloe in cosmetic and pharmaceutical industries, improvement of aloe (Aloe barbadensis Miller) by genetic engineering was seldom reported previously. In this study, regeneration and transformation conditions, including explant selection and surface sterilization, use of different Agrobacterium strains, and co-culture processing, are optimized. The use of 20.0% sodium hypochloride (25 rain) for sterilization was less detrimental to the health of explant than 0.1% mercuric chloride (10 min). Regeneration frequency from stems was much higher than that from leaves or sheaths. Explants were infected by Agrobacterium (30 rain) in liquid co-cultural medium, and this was followed by three days co-culture on sterile filter papers with light for 10 h per day at 24℃. Histochemical data demonstrated that the transient expression of GUS gene in the stem explants of aloe infected with Agrobacterium strains EHAI05 and C58CI was 80.0% and 30.0%, respectively, suggesting the higher sensitivity of the explants to EHAI05 than to C58C1. Infected tissues were selected using G418 (10.0-25.0 mg/L) to generate transformants. Sixty-seven G418 resistant plantlets were generated from the infected explants. Southern blotting, PCR, and ELISA analyses indicated that the alien gene were successfully transferred into aloe and was expressed in the transgenic plants. This newly established transformation system could be used for the genetic improvement of aloe.
基金Gansu Science and Technology Key Project under Grant No.2GS057-A52-008
文摘Traditional modal parameter identifi cation methods have many disadvantages,especially when used for processing nonlinear and non-stationary signals.In addition,they are usually not able to accurately identify the damping ratio and damage.In this study,methods based on the Hilbert-Huang transform(HHT) are investigated for structural modal parameter identifi cation and damage diagnosis.First,mirror extension and prediction via a radial basis function(RBF) neural network are used to restrain the troublesome end-effect issue in empirical mode decomposition(EMD),which is a crucial part of HHT.Then,the approaches based on HHT combined with other techniques,such as the random decrement technique(RDT),natural excitation technique(NExT) and stochastic subspace identifi cation(SSI),are proposed to identify modal parameters of structures.Furthermore,a damage diagnosis method based on the HHT is also proposed.Time-varying instantaneous frequency and instantaneous energy are used to identify the damage evolution of the structure.The relative amplitude of the Hilbert marginal spectrum is used to identify the damage location of the structure.Finally,acceleration records at gauge points from shaking table testing of a 12-story reinforced concrete frame model are taken to validate the proposed approaches.The results show that the proposed approaches based on HHT for modal parameter identifi cation and damage diagnosis are reliable and practical.
基金Supported by National Natural Science Foundation of China(Grant No.51377015)China Post Doctor Project(Grant No.136413)Science&Technology Department of Sichuan Province,China(Grant No.2013HH0059)
文摘Eddy current pulsed thermography(ECPT) is an emerging Non-destructive testing and evaluation(NDT E) technique, which uses hybrid eddy current and thermography NDT E techniques that enhances the detectability from their compensation. Currently, this technique is limited by the manual selection of proper contrast frames and the issue of improving the efficiency of defect detection of complex structure samples remains a challenge. In order to select a specific frame from transient thermal image sequences to maximize the contrast of thermal variation and defect pattern from complex structure samples, an energy driven approach to compute the coefficient energy of wavelet transform is proposed which has the potential of automatically selecting both optimal transient frame and spatial scale for defect detection using ECPT. According to analysis of the variation of different frequency component and the comparison study of the detection performance of different scale and wavelets, the frame at the end of heating phase is automatically selected as an optimal transient frame for defect detection. In addition, the detection capabilities of the complex structure samples can be enhanced through proper spatial scale and wavelet selection. The proposed method has successfully been applied to low speed impact damage detection of carbon fibre reinforced polymer(CFRP) composite as well as providing the guidance to improve the detectability of ECPT technique.
基金Supported by:Strategic International Science and Technology Innovation Cooperation Project from National Key R&D Program of China under Grant No.2018YFE0207100the National Natural Science Foundation of China under Grant No.41602332。
文摘Gravity retaining wall with geogrids has showed excellent seismic performance from Wenchuan great earthquake.However,seismic damage mechanism of this kind of wall is not sufficiently clear.In view of this,a large shaking table test of the gravity retaining wall with geogrids to reinforce the subgrade slope was carried out,and based on the HilbertHuang transform and the marginal spectrum theory,the energy identification method of the slope dynamic failure mode was studied.The results show that the geogrids can effectively reduce displacement and rotation of the retaining wall,and it can effectively absorb the energy of the ground movement when combined with the surrounding soil.In addition,it also reveals the failure development of the gravity retaining wall with geogrids to reinforce the subgrade slope.The damage started in the deep zone near the geogrids,and then gradually extended to the surface of the subgrade slope and other zones,finally formed a continuous failure surface along the geogrids.The analysis results of the failure mode identified by the Hilbert marginal spectrum are in good consistency with the experimental results,which prove that the Hilbert marginal spectrum can be applied to obtain the seismic damage mechanism of slope.
文摘The digital testing technique based on computers for dynamic characteristics of electrohydraulic servovalves via frequency scan method is researched. The no-load piston which measures the servo's transient output flow is designed properly. The velocity testing method by which the speed signal can be obtained indirectly by means of a piezoelectral accelerometer is given. High speed sampling has been realized in Windows OS. Wavelet denoising and Fourier transform are adopted in data processing and analyses. The testing technique discussed has been applied to actual testing systems and the experimental results have proved it to be correct.
文摘In the present paper, the authors introduce a new integral transform which yields a number of potentially useful (known or new) integral transfoms as its special cases. Many fundamental results about this new integral transform, which are established in this paper, in- clude (for example) existence theorem, Parseval-type relationship and inversion formula. The relationship between the new integral transform with the H-function and the H-transform are characterized by means of some integral identities. The introduced transform is also used to find solution to a certain differential equation. Some illustrative examples are also given.
文摘The high-rise frame structure has become more and more widespread, like its damage from the complication of the environment. The traditional method of damage detection, which is only suitable for the stationary signal, does not apply to a high-rise frame structure because its damage signal is non-stationary. Thus, this paper presents an application of the short-time Fourier transform(STFT) to damage detection of high-rise frame structures. Compared with the fast Fourier transform, STFT is found to be able to express the frequency spectrum property of the time interval using the signal within this interval. Application of STFT to analyzing a Matlab model and the shaking table test with a twelve-story frame-structure model reveals that there is a positive correlation between the slope of the frequency versus time and the damage level. If the slope is equal to or greater than zero, the structure is not damaged. If the slope is smaller than zero, the structure is damaged, and the less the slope is, the more serious the damage is. The damage results from calculation based on the Matlab model are consistent with those from the shaking table test, demonstrating that STFT can be a reliable tool for the damage detection of high-rise frame structures.
文摘A new online system of monitoring yarn quality and fault diagnosis is presented. This system integrates the technologies of sensor, signal process, communication, network, computer, control, instrument structure and mass knowledge of experts. Comparing with conventional off-line yarn test, the new system can find the quality defects of yarn online in time and compensate for the lack of expert knowledge in manual analysis. It can save a lot of yarn wasted in off-line test and improve product quality. By using laser sensor to sample the diameter signal of yarn and doing wavelet analysis and FFT to extract fault characteristics, a set of reasoning mechanism is established to analyze yarn quality and locate the fault origination. The experimental results show that new system can do well in monitoring yarn quality online comparing with conventional off-line yarn test. It can test the quality of yarn in real-time with high efficiency and analyze the fault reason accurately. It is very useful to apply this new system to upgrade yarn quality in cotton textile industry at present.
基金one part of the fruits of VHT(Virtual Heat Treatment)Project of IMS(Intelligent Manufacturing Science)Program supported by Ministry of Economy,Trade and Industries,Japan.
文摘Transformation plasticity is known to play an important role in the course of heat treatment processes, and so affect the results of heat treatment simulations, which means that the transformation plasticity coefficient is necessary to be identifies. The authors developed a new method by use of four-point bending system of a beam to identify transformation plasticity coefficient taking advantage of its easiness and high accuracy compared with other conventional methods like tension test, etc., and identified the coefficient for four kinds of steels; plane carbon steel, Cr-steel, Cr-Mo steel and bearing steel. In this paper, further experimental data are presented for the steels if the coefficient Kp during pearlite transformation depend on the applied stress. Obtained results reveals that the stress dependence of Kp is rather trivial except for uncertain tendency detected in plane carbon steel. The relation between the Kp and carbon content included is discussed in comparison with other data referred from references.