期刊文献+
共找到1,706篇文章
< 1 2 86 >
每页显示 20 50 100
Discharge evolution law of debris flow based on a sharp bend physical modeling test
1
作者 LU Ming SUN Hao +3 位作者 LIU Jinfeng Abrar HUSSAIN SHANG Yuqi FU Hang 《Journal of Mountain Science》 SCIE CSCD 2024年第6期1904-1915,共12页
For the basins with debris flow development,its channel terrain exhibits a tortuous shape,which significantly restricts the movement of debris flows and leads to severe erosion effects on the concave bank.Therefore,th... For the basins with debris flow development,its channel terrain exhibits a tortuous shape,which significantly restricts the movement of debris flows and leads to severe erosion effects on the concave bank.Therefore,this study aims to analyze the shear force of debris flows within the bend channel.We established the relationship between the shear force and bend curvature through laboratory experiments.Under the long-term erosion by debris flows,the curvature radius of bends gradually increases,however,when this increasing trend reaches an equilibrium state with the intensity of debris flow discharge,there will be no significant change in curvature radius.In general,the activity pattern and discharges of debris flows would remain relatively stable.Hence,we can infer the magnitude of debris flow discharges from the terrain parameters of the bend channel. 展开更多
关键词 Debris flow discharge Erosion effect Bend channel Curvature radius
下载PDF
Single flow treatment degradation of antibiotics in water using falling-film dielectric barrier discharge
2
作者 许志远 章程 +4 位作者 伍云健 黄邦斗 席登科 张晓星 邵涛 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第4期27-36,共10页
The environmental contamination caused by antibiotics is increasingly conspicuous due to their widespread manufacture and misuse. Plasma has been employed in recent years for the remediation of antibiotic pollution in... The environmental contamination caused by antibiotics is increasingly conspicuous due to their widespread manufacture and misuse. Plasma has been employed in recent years for the remediation of antibiotic pollution in the environment. In this work, a falling-film dielectric barrier discharge was used to degrade the antibiotic tetracycline(TC) in water. The reactor combined the gas-liquid discharge and active gas bubbling to improve the TC degradation performance. The discharge characteristics, chemical species’ concentration, and degradation rates at different parameters were systematically studied. Under the optimized conditions(working gas was pure oxygen, liquid flow rate was 100 mL/min, gas flow rate was 1 L/min,voltage was 20 kV, single treatment), TC was removed beyond 70% in a single flow treatment with an energy efficiency of 145 mg/(kW·h). The reactor design facilitated gas and liquid flow in the plasma area to produce more ozone in bubbles after a single flow under pure oxygen conditions, affording fast TC degradation. Furthermore, long-term stationary experiment indicated that long-lived active species can sustain the degradation of TC. Compared with other plasma treatment systems, this work offers a fast and efficient degradation method, showing significant potential in practical industrial applications. 展开更多
关键词 antibiotic degradation dielectric barrier discharge reactive species single flow treatment
下载PDF
Flow control performance evaluation of a tri-electrode sliding discharge plasma actuator
3
作者 郑博睿 刘园鹏 +3 位作者 喻明浩 金元中 张倩 陈全龙 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第9期348-355,共8页
Tri-electrode sliding discharge(TED)plasma actuators are formed by adding a direct current(DC)exposed electrode to conventional dielectric barrier discharge(DBD)plasma actuators.There are three TED modes depending on ... Tri-electrode sliding discharge(TED)plasma actuators are formed by adding a direct current(DC)exposed electrode to conventional dielectric barrier discharge(DBD)plasma actuators.There are three TED modes depending on the polarity and amplitude of the DC supply:DBD discharge,extended discharge and sliding discharge.This paper evaluates the electrical,aerodynamic and mechanical characteristics of a TED plasma actuator based on energy analysis,particle image velocimetry experiments and calculations using the Navier-Stokes equation.The flow control performances of different discharge modes are quantitatively analyzed based on characteristic parameters.The results show that flow control performance in both extended discharge and sliding discharge is more significant than that of DBD,mainly because of the significantly higher(up to 141%)body force of TED compared with DBD.However,conductivity loss is the primary power loss caused by the DC polarity for TED discharge.Therefore,power consumption can be reduced by optimizing the dielectric material and thickness,thus improving the flow control performance of plasma actuators. 展开更多
关键词 plasma flow control tri-electrode sliding discharge particle image velocimetry(PIV) performance evaluation
下载PDF
The effects of rainfall regimes and rainfall characteristics on peak discharge in a small debris flow-prone catchment 被引量:3
4
作者 WEI Zhen-lei SUN Hong-yue +2 位作者 XU Hao-di WU Gang XIE Wei 《Journal of Mountain Science》 SCIE CSCD 2019年第7期1646-1660,共15页
Peak discharge plays an important role in triggering channelized debris flows.The rainfall regimes and rainfall characteristics have been demonstrated to have important influences on peak discharge.In order to explore... Peak discharge plays an important role in triggering channelized debris flows.The rainfall regimes and rainfall characteristics have been demonstrated to have important influences on peak discharge.In order to explore the relationship between rainfall regimes and peak discharge,a measuring system was placed at the outlet of a small,debris flow-prone catchment.The facility consisted of an approximately rectangular stilling basin,ending with a sharp-crested weir.Six runoff events were recorded which provided a unique opportunity for characterizing the hydrological response of the debris flow-prone catchment.Then,a rainfall–runoff model was tested against the flow discharge measurements to have a deep understanding of hydrological response.Based on the calibrated rainfall-runoff model,twelve different artificially set rainfall patterns were regarded as the input parameters to investigate the effect of rainfall regimes on peak discharge.The results show that the rainfall patterns have a significant effect on peak discharge.The rainfall regimes which have higher peak rainfall intensity and peak rainfall point occur at the later part of rainfall process are easy to generate larger peak discharge in the condition of the same cumulative rainfall and duration.Then,in order to explore the relationship between rainfall characteristics and peak discharge under different cumulative precipitation and different duration,167 measured rainfall events were also collected.On the basis of rainfall depth,rainfall duration,and maximum hourly intensity,all the rainfall events were classified into four categories by using K-mean clustering.Rainfall regime 1 was composed of rainfall events with a moderate mean P(precipitation),a moderate D(duration),and a moderate I60(maximum hourly intensity).Rainfall regime 2 was the group of rainfall events with a high mean P,long D.Rainfall regime 3,however,had a low P and a long D.The characteristic of Rainfall regime 4 was high I60 and short duration with large P.The results show that the rainfall regime 2 and 4 are easier to generate peak discharge as the rainfall intensity plays an important role in generating peak discharge.The results in this study have implications for improving peak discharge prediction accuracy in debris flow gully. 展开更多
关键词 DEBRIS flow RAINFALL regimes RAINFALL characteristics Peak discharge RAINFALL-RUNOFF model
下载PDF
Analysis of flow separation control using nanosecond-pulse discharge plasma actuators on a flying wing 被引量:4
5
作者 李铮 史志伟 +3 位作者 杜海 孙琪杰 魏晨瑶 耿玺 《Plasma Science and Technology》 SCIE EI CAS CSCD 2018年第11期116-125,共10页
Dielectric barrier discharge (DBD) plasma is one of most promising flow control method for its several advantages. The present work investigates the control authority of nanosecond pulse DBD plasma actuators on a fl... Dielectric barrier discharge (DBD) plasma is one of most promising flow control method for its several advantages. The present work investigates the control authority of nanosecond pulse DBD plasma actuators on a flying wing model's aerodynamic characteristics. The aerodynamic forces and moments are studied by means of experiment and numerical simulation. The numerical simulation results are in good agreement with experiment results. Both results indicate that the NS-DBD plasma actuators have negligible effect on aerodynamic forces and moment at the angles of attack smaller than 16-. However, significant changes can be achieved with actuation when the model's angle of attack is larger than 16° where the flow separation occurs. The spatial flow field structure results from numerical simulation suggest that the volumetric heat produced by NS-DBD plasma actuator changes the local temperature and density and induces several vortex structures, which strengthen the mixing of the shear layer with the main flow and delay separation or even reattach the separated flow. 展开更多
关键词 nanosecond dielectric barrier discharge flying wing aircraft flow separation control
下载PDF
Numerical Simulation of Unsteady Discharge Flow with Fluctuation in Positive Discharge Blower 被引量:3
6
作者 LIU Zhengxia WANG Dou XU Lianhuan 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2009年第2期214-220,共7页
The operating performance of positive discharge blower is markedly influenced by the pulsation of the discharge flow, but difficult to be measured with experimental methods. The internal and discharge flow of positive... The operating performance of positive discharge blower is markedly influenced by the pulsation of the discharge flow, but difficult to be measured with experimental methods. The internal and discharge flow of positive discharge blower with involute type three-lobe are numerically investigated, both in air cooling and countercurrent cooling conditions by means of computational fluid dynamics (CFD). The unsteady compressible flow equations are solved using RNG x-ε turbulent model. The finite difference method and the second order upwind difference scheme are applied into discrete equations. In the numerical simulation, the dynamic mesh techniques are used to approach the rotating displacement of cell cubage and the alterability of inlet, outlet flow area. The non-uniform mesh is applied to the rotor-stator coupled area. The reliability of the numerical method is verified by simulating the inner flow and comparing with the semi-empirical theory. The flow flux curves and the distributing of velocity vector showed obvious vortex motion in all the discharge process, both in air cooling and countercurrent cooling conditions. These vortexes with different positions, intension and numbers at different rotating angles have remarkable influences on the discharge flux. For air cooling, the vortex produced a second pulsation with big-amplitude in a cycle, and led to the early appearance of maximum of backflow. For countercurrent cooling, the frequency of pulsation increased due to the pre-inflow, but the backflow at the outlet is prevented, also the pulsation strength has greatly decreased. 展开更多
关键词 countercurrent cooling positive discharge blower dynamic mashing techniques flow fluctuation mumerical simulation
下载PDF
Experimental Study on Surface Dielectric Barrier Discharge Plasma Actuator with Different Encapsulated Electrode Widths for Airflow Control at Atmospheric Pressure 被引量:3
7
作者 齐晓华 杨亮 +3 位作者 闫慧杰 金英 滑跃 任春生 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第10期1005-1011,共7页
The surface dielectric barrier discharge (SDBD) plasma actuator has shown great promise as an aerodynamic flow control device. In this paper, the encapsulated electrode width of a SDBD actuator is changed to study t... The surface dielectric barrier discharge (SDBD) plasma actuator has shown great promise as an aerodynamic flow control device. In this paper, the encapsulated electrode width of a SDBD actuator is changed to study the airflow acceleration behavior. The effects of encapsulated electrode width on the actuator performance are experimentally investigated by measuring the dielectric layer surface potential, time-averaged ionic wind velocity and thrust force. Experimental results show that the airflow velocity and thrust force increase with the encapsulated electrode width. The results can be attributed to the distinct plasma distribution at different encapsulated electrode widths. 展开更多
关键词 atmospheric pressure discharge plasma surface dielectric barrier discharge(SDBD) flow control encapsulated electrode width Schlieren visualization
下载PDF
The effects of drainage basin geomorphometry on minimum low flow discharge: the study of small watershed in Kelang River Valley in Peninsular Malaysia 被引量:2
8
作者 Ahmad Jailani Muhamed Yunus Nobukazu Nakagoshi Khairulmaini Osman Salleh 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2003年第2期249-262,共14页
This study investigate the relationships between geomorphometric properties and the minimum low flow discharge of undisturbed drainage basins in the Taman Bukit Cahaya Seri Alam Forest Reserve, Peninsular Malaysia. Th... This study investigate the relationships between geomorphometric properties and the minimum low flow discharge of undisturbed drainage basins in the Taman Bukit Cahaya Seri Alam Forest Reserve, Peninsular Malaysia. The drainage basins selected were third-order basins so as to facilitate a common base for sampling and performing an unbiased statistical analyses. Three levels of relationships were observed in the study. Significant relationships existed between the geomorphometric properties as shown by the correlation network analysis; secondly, individual geomorphometric properties were observed to influence minimum flow discharge; and finally, the multiple regression model set up showed that minimum flow discharge(Q min) was dependent of basin area(AU), stream length(LS), maximum relief(Hmax), average relief(HAV) and stream frequency(SF). These findings further enforced other studies of this nature that drainage basins were dynamic and functional entities whose operations were governed by complex interrelationships occurring within the basins. Changes to any of the geomorphometric properties would influence their role as basin regulators thus influencing a change in basin response. In the case of the basin's minimum low flow, a change in any of the properties considered in the regression model influenced the “time to peak' of flow. A shorter time period would mean higher discharge, which is generally considered the prerequisite to flooding. This research also conclude that the role of geomorphometric properties to control the water supply within the stream through out the year even though during the drought and less precipitations months. Drainage basins are sensitive entities and any deteriorations involve will generate reciprocals and response to the water supply as well as the habitat within the areas. 展开更多
关键词 geomorphometric minimum low flow discharge regression model third-order drainage basins
下载PDF
Seasonal and interannual variations of flow discharge from Pearl River into sea 被引量:2
9
作者 Wei ZHANG Shou-sheng MU +1 位作者 Yan-jing ZHANG Kai-min CHEN 《Water Science and Engineering》 EI CAS 2012年第4期399-409,共11页
Flow discharge from the river basin into the sea has severe impacts on the immediate vicinity of river channels, estuaries, and coastal areas. This paper analyzes the features and temporal trends of flow discharge at ... Flow discharge from the river basin into the sea has severe impacts on the immediate vicinity of river channels, estuaries, and coastal areas. This paper analyzes the features and temporal trends of flow discharge at Pearl River's three main gauge stations: the Wuzhou, Shijiao, and Boluo gauge stations on the West River, North River, and East River, respectively. The results show no significant trend in annual mean discharge into the sea at the three gauge stations. Changes of monthly mean discharge at the Boluo Gauge Station are evident, and a majority of monthly discharge in the dry season displays significant increasing trends. Furthermore, changes of the extreme discharge are quite evident, with a significant decreasing trend in the annual maximum discharge and a significant increasing trend in the minimum one. The significantly decreasing ratio of the flood discharge to annual discharge at the Boluo Gauge Station indicates that the flow discharge from the East River has increased in the dry season and decreased in the flood season since the construction of dams and reservoirs. At the other two gauge stations, the Wuzhou and Shijiao gauge stations, the seasonal discharge generally does not change perceptibly. Human impacts, especially those pertaining to reservoir and dam construction, appear to be responsible for the seasonal variation of flow discharge. The results indicate that the construction and operation of dams and reservoirs in the East River have a greater influence on flow discharge, which can well explain why the seasonal variation of flow discharge from the East River is more evident. 展开更多
关键词 Pearl River flow discharge climate change human impact dam and reservoir
下载PDF
Rotor performance enhancement by alternating current dielectric barrier discharge plasma actuation
10
作者 赵光银 王畅 +2 位作者 杨永东 李国强 史喆羽 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第1期120-127,共8页
An experimental system was established to explore the plasma flow control effect for helicopter rotors in hover mode.With the plasma actuator applied at the leading edge of the rotor blades,alternating current dielect... An experimental system was established to explore the plasma flow control effect for helicopter rotors in hover mode.With the plasma actuator applied at the leading edge of the rotor blades,alternating current dielectric barrier discharge(AC-DBD) plasma actuation was generated by a sinusoidal AC high-voltage generator.By direct force measurement,the influence of actuation parameters on the aerodynamic performance of the rotor was investigated at a tip Reynolds number of 1.7 × 105.AC-DBD actuation can delay the blade stall to more than 3° with a 20%increase of about in the thrust coefficient at the post-stall pitch.At a constant motor power driving the rotor,AC-DBD actuation could reduce the rotor’s torque at the stalled pitch and increase the rotational speed of the rotor.Also,AC-DBD actuation could maintain a relatively high hover efficiency of the rotor at large collective pitches.In a wide range of actuation parameters,AC-DBD plasma actuation could improve the rotor’s aerodynamic performance at large blade pitches.High-speed photography of the tuft motion on the blade’s upper surface showed that AC-DBD plasma actuation could promote the reattachment of the blade’s separation flow. 展开更多
关键词 ROTOR flow control plasma actuator dielectric barrier discharge force measurement
下载PDF
Two-Phase Flow Regimes and Discharge Characteristics of a Plasma Electrohydrodynamic Atomization 被引量:1
11
作者 孙明 D.BOROCILO +5 位作者 G.D.HARVEL M.IBE H.MATSUBARA P.FANSON H.HIRATA J.S.CHANG 《Plasma Science and Technology》 SCIE EI CAS CSCD 2011年第1期73-76,共4页
Experimental investigation was conducted to study the flow regimes and discharge characteristics of plasma electrohydrodynamic atomization (EHDA) for decane (CloH22) under pulsed applied negative voltage. The expe... Experimental investigation was conducted to study the flow regimes and discharge characteristics of plasma electrohydrodynamic atomization (EHDA) for decane (CloH22) under pulsed applied negative voltage. The experimental parameters were set as the flow rate of decane from 0 mL/min to 10 mL/min and the DC charging voltage from DC 0 V to 12 V with a pulse repetition rates of 200 Hz. The flow regime of decane was observed and the volume-to-electrical charge ratio was measured. Unlike a conventional EHDA system, the results show that a corona discharge was initiated at the edge of the hollow electrode at a specific corona on-set voltage of -17 kV or -20 kV in the case with or without decane flow, respectively. This phenomenon was defined as plasma EHDA. 展开更多
关键词 plasma eletrohydrodynamic atomization DECANE pulsed corona discharge flow regime
下载PDF
Thermal and induced flow characteristics of radio frequency surface dielectric barrier discharge plasma actuation at atmospheric pressure 被引量:1
12
作者 王蔚龙 李军 +3 位作者 宋慧敏 金迪 贾敏 吴云 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第1期320-325,共6页
Thermal and induced flow velocity characteristics of radio frequency(RF) surface dielectric barrier discharge(SDBD)plasma actuation are experimentally investigated in this paper. The spatial and temporal distribut... Thermal and induced flow velocity characteristics of radio frequency(RF) surface dielectric barrier discharge(SDBD)plasma actuation are experimentally investigated in this paper. The spatial and temporal distributions of the dielectric surface temperature are measured with the infrared thermography at atmospheric pressure. In the spanwise direction, the highest dielectric surface temperature is acquired at the center of the high voltage electrode, while it reduces gradually along the chordwise direction. The maximum temperature of the dielectric surface raises rapidly once discharge begins.After several seconds(typically 100 s), the temperature reaches equilibrium among the actuator's surface, plasma, and surrounding air. The maximum dielectric surface temperature is higher than that powered by an AC power supply in dozens of k Hz. Influences of the duty cycle and the input frequency on the thermal characteristics are analyzed. When the duty cycle increases, the maximum dielectric surface temperature increases linearly. However, the maximum dielectric surface temperature increases nonlinearly when the input frequency varies from 0.47 MHz to 1.61 MHz. The induced flow velocity of the RF SDBD actuator is 0.25 m/s. 展开更多
关键词 radio frequency discharge temperature distribution induced flow velocity plasma aerodynamic actuation
下载PDF
Experimental Investigation of Flow Separation Control Using Dielectric Barrier Discharge Plasma Actuators 被引量:1
13
作者 李钢 聂超群 +2 位作者 李轶明 朱俊强 徐燕骥 《Plasma Science and Technology》 SCIE EI CAS CSCD 2008年第5期605-611,共7页
Influence of plasma actuators as a flow separation control device was investigated experimentally. Hump model was used to demonstrate the effect of plasma actuators on external flow separation, while for internal flow... Influence of plasma actuators as a flow separation control device was investigated experimentally. Hump model was used to demonstrate the effect of plasma actuators on external flow separation, while for internal flow separation a set of compressor cascade was adopted. In order to investigate the modification of the flow structure by the plasma actuator, the flow field was examined non-intrusively by particle image velocimetry measurements in the hump model experiment and by a hot film probe in the compressor cascade experiment. The results showed that the plasma actuator could be effective in controlling the flow separation both over the hump and in the compressor cascade when the incoming velocity was low. As the incoming velocity increased, the plasma actuator was less effective. It is urgent to enhance the intensity of the plasma actuator for its better application. Methods to increase the intensity of plasma actuator were also studied. 展开更多
关键词 dielectric barrier discharge PLASMA separation flow control hump model compressor cascade
下载PDF
The Effect of Gas Flow Rate on Radio-Frequency Hollow Cathode Discharge Characteristics 被引量:1
14
作者 赵国明 孙倩 +2 位作者 赵书霞 高书侠 张连珠 《Plasma Science and Technology》 SCIE EI CAS CSCD 2014年第7期669-676,共8页
It is known that gas flow rate is a key factor in controlling industrial plasma processing. In this paper, a 2D PIC/MCC model is developed for an rf hollow cathode discharge with an axial nitrogen gas flow. The effect... It is known that gas flow rate is a key factor in controlling industrial plasma processing. In this paper, a 2D PIC/MCC model is developed for an rf hollow cathode discharge with an axial nitrogen gas flow. The effects of the gas flow rate on the plasma parameters are calculated and the results show that: with an increasing flow rate, the total ion(N+2, N+) density decreases, the mean sheath thickness becomes wider, the radial electric field in the sheath and the axial electric field show an increase, and the energies of both kinds of nitrogen ions increase;and, as the axial ion current density that is moving toward the ground electrode increases, the ion current density near the ground electrode increases. The simulation results will provide a useful reference for plasma jet technology involving rf hollow cathode discharges in N2. 展开更多
关键词 gas flow rate rf hollow cathode discharge PIC/MCC simulation N2 plasma
下载PDF
Study on water treatment effect of dispersion discharge plasma based on flowing water film electrode 被引量:1
15
作者 刘文正 包颖 +1 位作者 段晓霞 张坚 《Plasma Science and Technology》 SCIE EI CAS CSCD 2021年第10期168-178,共11页
To improve the utilization rate of plasma active species,in this study,a closed non-uniform air gap is formed by a flowing water film electrode and a sawtooth insulating dielectric layer to realize the diffuse glow di... To improve the utilization rate of plasma active species,in this study,a closed non-uniform air gap is formed by a flowing water film electrode and a sawtooth insulating dielectric layer to realize the diffuse glow discharge in the atmosphere.Firstly,the electric field distribution characteristics of non-uniform air gap in the sawtooth dielectric layer are studied,and the influence of aspect ratio on the characteristics of diffuse discharge plasma is discussed.Subsequently,the effects of wire mesh,the inclination angle of the dielectric plate,and liquid inlet velocity on the flow characteristics of the water film electrode are analyzed.The results show that the non-uniform electric field distribution formed in the sawtooth groove can effectively inhibit the filamentous discharge,and the 1 mm flowing water film is directly used as the electrode,and high-active plasma is formed directly on the lower surface of the water film.In addition,a plasma flowing water treatment device is built to treat the methyl orange solution and observe its decolorization effect.The experimental results show that after 50 min of treatment,the decolorization rate of the methyl orange solution reaches 96%,which provides a new idea for industrial applications of wastewater treatment. 展开更多
关键词 water film electrode dispersive glow discharge plasma inhomogeneous electric field closed discharge space flowing water treatment
下载PDF
Aerodynamic actuation characteristics of radio-frequency discharge plasma and control of supersonic flow
16
作者 杨臻 宋慧敏 +3 位作者 王宏宇 郭善广 贾敏 王康 《Chinese Physics B》 SCIE EI CAS CSCD 2019年第2期321-330,共10页
In this paper, aerodynamic actuation characteristics of radio-frequency(RF) discharge plasma are studied and a method is proposed for shock wave control based on RF discharge. Under the static condition, a RF diffuse ... In this paper, aerodynamic actuation characteristics of radio-frequency(RF) discharge plasma are studied and a method is proposed for shock wave control based on RF discharge. Under the static condition, a RF diffuse glow discharge can be observed; under the supersonic inflow, the plasma is blown downstream but remains continuous and stable.Time-resolved schlieren is used for flow field visualization. It is found that RF discharge not only leads to continuous energy deposition on the electrode surface but also induces a compression wave. Under the supersonic inflow condition, a weak oblique shock wave is induced by discharge. Experimental results of the shock wave control indicate that the applied actuation can disperse the bottom structure of the ramp-induced oblique shock wave, which is also observed in the extracted shock wave structure after image processing. More importantly, this control effect can be maintained steadily due to the continuous high-frequency(MHz) discharge. Finally, correlations for schlieren images and numerical simulations are employed to further explore the flow control mechanism. It is observed that the vortex in the boundary layer increases after the application of actuation, meaning that the boundary layer in the downstream of the actuation position is thickened. This is equivalent to covering a layer of low-density smooth wall around the compression corner and on the ramp surface, thereby weakening the compressibility at the compression corner. Our results demonstrate the ability of RF plasma aerodynamic actuation to control the supersonic airflow. 展开更多
关键词 radio-frequency(RF) discharge PLASMA surface discharge flow control aerodynamic ACTUATION
下载PDF
The effects of gas flow pattern on the generation of ozone in surface dielectric barrier discharge
17
作者 谢松汝 何勇 +4 位作者 袁定琨 王智化 Sunel KUMAR 朱燕群 岑可法 《Plasma Science and Technology》 SCIE EI CAS CSCD 2019年第5期168-178,共11页
Ozone production utilizing surface dielectric barrier discharge(SDBD)was experimental studied for different flow patterns considering the influences of transversal flow,lateral flow and different lateral flow position... Ozone production utilizing surface dielectric barrier discharge(SDBD)was experimental studied for different flow patterns considering the influences of transversal flow,lateral flow and different lateral flow positions.Results show that the flow patterns have a remarkable impact on the ozone yield by affecting the uniformity and turbulenee of gas flow.Meanwhile,distributing the O2 flow rate according to the intensity of the plasma reaction would also increase the generation efficiency of SDBD for ozone production.By improving the uniformity and introducing the lateral flow to the transversal flow,the highest ozone yield was obtained in flow pattern'F‘.In this case,the ozone yield increased by 28.4%to 131 g kWh^-1 from 102.8 g kWh^-1 in flow pattern‘A’. 展开更多
关键词 surface DIELECTRIC BARRIER discharge gas flow OZONE generation
下载PDF
Numerical Study on Instantaneous Discharge of Unsorted Particle Cloud in Cross Flow
18
作者 顾杰 李志伟 +1 位作者 杨红 詹咏 《China Ocean Engineering》 SCIE EI 2007年第2期305-316,共12页
The mixing characteristics of particles such as dredged sediment of variable size discharged into cross flow are studied by a 3D numerical modal, which is developed to model the particle-fluid two-phase flow. The Eule... The mixing characteristics of particles such as dredged sediment of variable size discharged into cross flow are studied by a 3D numerical modal, which is developed to model the particle-fluid two-phase flow. The Eulerian method with the modified k- ε parameterization of turbulence for the fluid phase is used to solve fluid phase, while a Lagrangian method for the sohd phase (particles), both the processes are coupled through the momentmn sources. In the model the wake turbulence induced by particles has been included as additional source term in the k - ε model; and the variable drift velocities of the particles are treated efficiently by the Lagrangian method in which the particles are tracked explicitly and the diffusion process is approximated by a random walk model. The hydrodynamic behavior of dumping a cloud of particles is governed by the total buoyancy of the cloud, the drag force on each particle and the velocity of cross-flow. The computed results show a roughly linear relationship between the displacement of the frontal position and the longitudi- nal width of the particle cloud. The particle size in the cloud and the velocity of cross flow dominate the flow behavior. The computed results are compared with the results of laboratory experiments and satisfactory agreement is obtained. 展开更多
关键词 3D numerical model two-phase flow Eulerian-Lagrangian method instantaneous discharge particlecloud cross flow
下载PDF
The Effect of Flow Distribution on the Concentration of NO Produced by Pulsed Arc Discharge
19
作者 胡辉 包滨 +4 位作者 王贺礼 梁海艳 何俊佳 何正浩 李劲 《Plasma Science and Technology》 SCIE EI CAS CSCD 2007年第6期766-769,共4页
As a new method to cure acute respiratory distress syndrome (ARDS), high blood pressure and some illnesses related to the lung, NO has recently received more attention. Thermal plasmas produced by arc discharge can ... As a new method to cure acute respiratory distress syndrome (ARDS), high blood pressure and some illnesses related to the lung, NO has recently received more attention. Thermal plasmas produced by arc discharge can create medical NO, but the concentration of NO2 produced by arc discharge must be controlled simultaneously. This paper investigates the characteristics and regulations of NO production at different flow distribution by pulsed arc discharge in dry air with a special pulsed power, The experimental results show that the flow distribution has a considerable effect on the NO concentration, the stabilization of NO. The production of NO2 could be controlled and the ratio of NO2/NO was decreased to about 10% in the arc discharge. Therefore, the arc discharge could produce stable inhaled NO for medical treatment by changing the flow distribution. 展开更多
关键词 nitric oxide flow distribution pulsed arc discharge ARDS
下载PDF
Effects of Gas Flow Rate on the Discharge Characteristics of a DC Excited Plasma Jet
20
作者 李雪辰 贾鹏英 +2 位作者 狄聪 鲍文婷 张春燕 《Plasma Science and Technology》 SCIE EI CAS CSCD 2015年第9期738-742,共5页
A direct current(DC) source excited plasma jet consisting of a hollow needle anode and a plate cathode has been developed to form a diffuse discharge plume in ambient air with flowing argon as the working gas.Using ... A direct current(DC) source excited plasma jet consisting of a hollow needle anode and a plate cathode has been developed to form a diffuse discharge plume in ambient air with flowing argon as the working gas.Using optical and electrical methods,the discharge characteristics are investigated for the diffuse plasma plume.Results indicate that the discharge has a pulse characteristic,under the excitation of a DC voltage.The discharge pulse corresponds to the propagation process of a plasma bullet travelling from the anode to the cathode.It is found that,with an increment of the gas flow rate,both the discharge plume length and the current peak value of the pulsed discharge decrease in the laminar flow mode,reach their minima at about1.5 L/min,and then slightly increase in the turbulent mode.However,the frequency of the pulsed discharge increases in the laminar mode with increasing the argon flow rate until the argon flow rate equals to about 1.5 L/min,and then slightly decreases in the turbulent mode. 展开更多
关键词 DC excited plasma jet plasma bullet pulsed discharge gas flow rate laminar mode turbulent mode
下载PDF
上一页 1 2 86 下一页 到第
使用帮助 返回顶部