期刊文献+
共找到14,898篇文章
< 1 2 250 >
每页显示 20 50 100
ENTROPY CHARACTERISTICS OF MAGNETIC REFRIGERANTS
1
作者 You Lixin Guo Xianming Xu Shefa (Denartment of Aircraft Engineering.NUAA,29 Yudao Street.Nanjing 210016.P.R.China) 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 1994年第2期132-138,共7页
Mathematical models for predicting magnetic entropy,lattice entropy and electron entropy of magnetic refrigerants are carried out from the molecular field appoximation,the Debye model and the electron energy level the... Mathematical models for predicting magnetic entropy,lattice entropy and electron entropy of magnetic refrigerants are carried out from the molecular field appoximation,the Debye model and the electron energy level theory respectively of quantum mechanics.Using theabove models the temperature and magnetic field dependences of the calculated magnetic entropy,lattice entropy,electron entropy and the total entropy of gadolinium,which is a typical magnetic refrigerant near room temperature,are obtained.The Influences of kinds of entropy on the performance of magnetic refrigeration are discussed,and some general rules for selecting magnetic refrlyerants are drawn to hely the develoyment of highly economic magnetic refrigerators. 展开更多
关键词 refrigerATION cryogenics MAGNETIC refrigerators MAGNETIC refrigerants AERONAUTICS AEROSPACE
下载PDF
OPTIMIZATION OF THE COMPOSITIONS FOR CFC ALTERNATIVE MIXTURE REFRIGERANTS
2
作者 杜连贵 汪文川 +1 位作者 郑丹星 傅举孚 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 1995年第1期35-41,共7页
In this work,eight commonly used and recently developed cubic EOSs have beenextensively tested for the calculation of thermodynamic properties,including vapor pressure,vaporand liquid densities and heat of vaporizatio... In this work,eight commonly used and recently developed cubic EOSs have beenextensively tested for the calculation of thermodynamic properties,including vapor pressure,vaporand liquid densities and heat of vaporization for 26 pure CFCs and their alternatives.The modifiedDu-Guo EOS is recommended for the vapor-liquid equilibria calculations of mixtures for its goodaccuracy.A method for the development of the optimized mixture compositions of CFC alternativeshas been proposed by using minimization of deviations between the vapor pressures of CFC and thealternative mixtures of interest.As examples,two binary mixtures R22-R142b and R22-R152a,and aternary R22-R142b-R152a have been tested.The results show that the vapor pressure of R12 can bewell duplicated by a mixture refrigerant with the optimized composition.On the other hand,thedeviations between the heat of vaporization are somewhat apparent within 10 percent.Moreover,allthe mixtures discussed here are of the characteristics of being near azeotropic。 展开更多
关键词 VAPOR-LIQUID EQUILIBRIA MIXTURE refrigerANT chlororfluorocarbon
下载PDF
Thermodynamic Analysis of Hydrocarbon Refrigerants-Based Ethylene BOG Re-liquefaction System
3
作者 Boumedienne M. Beladjine Ahmed Ouadha Yacine Addad 《Journal of Marine Science and Application》 CSCD 2016年第3期321-330,共10页
The present study aims to make a thermodynamic analysis of an ethylene cascade re-liquefaction system that consists of the following two subsystems: a liquefaction cycle using ethylene as the working fluid and a refri... The present study aims to make a thermodynamic analysis of an ethylene cascade re-liquefaction system that consists of the following two subsystems: a liquefaction cycle using ethylene as the working fluid and a refrigeration cycle operating with a hydrocarbon refrigerant. The hydrocarbon refrigerants considered are propane(R290), butane(R600), isobutane(R600a), and propylene(R1270). A computer program written in FORTRAN is developed to compute parameters for characteristic points of the cycles and the system's performance, which is determined and analyzed using numerical solutions for the refrigerant condensation temperature, temperature in tank, and temperature difference in the cascade condenser. Results show that R600 a gives the best performance, followed by(in order) R600, R290, and R1270. Furthermore, it is found that an increase in tank temperature improves system performance but that an increase in refrigerant condensation temperature causes deterioration. In addition, it is found that running the system at a low temperature difference in the cascade condenser is advantageous. 展开更多
关键词 ethylene BOG re-liquefaction thermodynamic analysis hydrocarbon refrigerants
下载PDF
AIR CONDITIONING REFRIGERANTS AND OZONE PROTECTION
4
作者 周亚素 华征宇 《Journal of China Textile University(English Edition)》 EI CAS 1995年第1期56-60,共5页
Until recently, CFC-11 and CFC-12 were the most widely used refrigerant gases in air conditioning systems. Environmental agencies around the world, however, have specifical concern for these gases as a direct cause of... Until recently, CFC-11 and CFC-12 were the most widely used refrigerant gases in air conditioning systems. Environmental agencies around the world, however, have specifical concern for these gases as a direct cause of the depletion of the Earth’s ozone layer. Consequently, the world’s industrial nations are taking concerted action to decrease the use of CFCs, calling for attention of the engineers and designers involved in the manufacture and application of refrigeration systems for air conditioning. This paper analyses the available alternatives of CFCs in the industry and examines the problem found in process application. 展开更多
关键词 air CONDITIONING refeigerant CHLOROFLUOROCARBONS OZONE layer ALTERNATIVE refrigerant.
下载PDF
Development of Environmentally Friendly and Energy Efficient Refrigerants for Refrigeration Systems
5
作者 Piyanut Saengsikhiao Juntakan Taweekun +2 位作者 Kittinan Maliwan Somchai Sae-ung Thanansak Theppaya 《Energy Engineering》 EI 2021年第2期411-433,共23页
This paper presents the improvement of eco-friendly and power consumption saving refrigerants for refrigeration systems.The novel azeotropic refrigerant mixtures of HFCs and HCs can replace refrigeration systems,and u... This paper presents the improvement of eco-friendly and power consumption saving refrigerants for refrigeration systems.The novel azeotropic refrigerant mixtures of HFCs and HCs can replace refrigeration systems,and using the R134,R32,R125,and R1270 refrigerants in several compositions found using the decision tree function of the RapidMiner software(which camefirst in the KDnuggets annual software poll).All refrigerant results are mixed of POE,which is A1 classification refrigerant,non-flammable,and innocuous refrigerant,and using REFPROP software and CYCLE_D-HX software are under the CAN/ANSI/AHRI540 standards.The boiling point of the new refrigerant mix R-No.595 is 4.58%,lower than that of R404A,with a higher refrigerant effect and 50.34%lower GWP value than R404A.The proposed mix R-No.595 can be operated in hot environmental country and has high critical temperature and heat-rejection effects,due to the presence of R32 and R1270.The COPc of R463A is 13.49%,higher than R404A in freeze condition.The novel refrigerant mixes provide alternate refrig-erant options mixed of 1%R1270,and which are related with the development of current refrigerants,containing a compose of HFOs and eco refrigerants for producing low-GWP,zero ODP,high-refrigerant effect,low-operating pressure,and innocuous refrigerants. 展开更多
关键词 refrigerANT refrigeration system energy efficiency environmentally friendly data mining
下载PDF
Numerical Investigations on Supercritical Heat Transfer Characteristics of Environmental Friendly Refrigerants
6
作者 Adnan Ibrahim Peng Hu +5 位作者 Yiran Jiang Ali Riaz Farrukh Saleem Yifang Dong Lei Jia Panpan Zhao 《International Journal of Clean Coal and Energy》 2021年第2期21-40,共20页
The heat transfer of supercritical fluids is a vastly growing field, specifically to find suitable alternatives to replace conventional R134a, which can be beneficial for climate change. Most of the experimental and n... The heat transfer of supercritical fluids is a vastly growing field, specifically to find suitable alternatives to replace conventional R134a, which can be beneficial for climate change. Most of the experimental and numerical investigations have been conducted to explore supercritical water, carbon dioxide and R134a as heat transfer working fluids. Hydrofluoroolefin (HFO) and refrigerants blends have been considered the most environment-friendly refrigerants to replace Chlorofluorocarbons (CFCs), Hydrochlorofluoro-carbons (HCFCs) and Hydrofluorocarbons (HFCs). Their main advantage of zero Ozone Depletion Potential (ODP) and comparatively lower Global Warming Potential (GWP) have attracted growing amount of attention to mitigate environmental issues. This work adopts the computational method and takes the environmentally friendly refrigerants to investigate the heat transfer characteristics under widely used shear-stress transport (SST) model. A comprehensive comparison was performed at reduced pressure of 1.10 for supercritical fluids R515A, R1234ze(E) and R134a. The peaks of heat transfer coefficient occurred in the vicinity of pseudo critical temperature for all of these considered fluids;however, R134a resulted in higher heat transfer coefficient, Reynolds number and Prandtl number in comparison with R515A and R1234ze(E). The higher heat transfer coefficient of supercritical fluid R134a is owing to its thermophysical properties and the specific heat plays crucial role in the heat transfer of supercritical fluids. Owing to environmental issues, R515A can be a considerable replacement of R134a. R1234ze(E) is also promising alternative to R134a;however, safety issues should thoroughly concern its mild flammable characteristics. 展开更多
关键词 Heat Transfer Supercritical Fluids Simulations R515A R1234ze(E) Environmental Friendly refrigerants
下载PDF
Theoretical and Experimental Study of Explosion Limits and the Inhibition of Flammable Refrigerants
7
作者 Guansan Tian Xingquan Li +1 位作者 Yunfeng Gao Fengxia Zhang 《Journal of Software Engineering and Applications》 2016年第10期501-515,共15页
In this study, we analyze factors affecting the explosion limits of flammable refrigerants. We conclude that any method used for measuring flammable refrigerant explosion limits has its conditional restrictions. Flamm... In this study, we analyze factors affecting the explosion limits of flammable refrigerants. We conclude that any method used for measuring flammable refrigerant explosion limits has its conditional restrictions. Flammable refrigerants in the atmosphere can also explode under certain conditions, when the concentration is approaching the explosion limits. An experimental study on the explosion limits of six kinds of flammable refrigerants is carried out with a mixture of refrigerant and combustible refrigerant, which has a similar effect to a flame retardant. An experimental apparatus was designed to test the explosion limits of mixtures made from three different nonflammable refrigerants and six different flammable refrigerants. Two practical models were developed to estimate the critical concentration for inhibiting explosion of refrigerant mixtures: one was made up of two flammable components with one nonflammable component, and the second was made up of one flammable component with two nonflammable components. 展开更多
关键词 Flammable refrigerants Explosion Limits Impact Factors INHIBITION
下载PDF
Magnetocaloric properties of phenolic resin bonded La(Fe,Si)13-based plates and its use in a hybrid magnetic refrigerator
8
作者 徐少山 付琪 +6 位作者 周益帆 彭铃 高新强 李振兴 公茂琼 董学强 沈俊 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第2期460-467,共8页
We present a simple hot press-based method for processing La(Fe,Si)13-based compounds consisting of La–Fe–Co–Si–C particles and phenolic resin. The magnetic entropy change △S per unit mass for the La Fe_(10.87)Co... We present a simple hot press-based method for processing La(Fe,Si)13-based compounds consisting of La–Fe–Co–Si–C particles and phenolic resin. The magnetic entropy change △S per unit mass for the La Fe_(10.87)Co_(0.63)Si_(1.5)C_(0.2)/phenolic resin compounds have nearly the same magnitude with the base materials. With the content of phenolic resin of 5.0 wt%, the compound conductivity is 3.13 W·m^(-1)·K^(-1). In order to measure the cooling performance of La(Fe,Si)13-based compounds,the La(Fe_(11.6-x)Co_(x))Si_(1.4)C_(0.15)(x =0.60, 0.65, 0.75, 0.80, 0.85)/phenolic resin compounds were pressed into thin plates and tested in a hybrid refrigerator that combines the active magnetic refrigeration effect with the Stirling cycle refrigeration effect. The test results showed that a maximum cooling power of 41 W was achieved over a temperature span of 30 K. 展开更多
关键词 magnetocaloric effect La(Fe Si)13 phenolic resin magnetic refrigeration hybrid refrigerator
下载PDF
Effect of Refrigerant on the Performance of a C3/MRC Liquefaction Process
9
作者 Xiao Wu Zhaoting Wang +2 位作者 Longfei Dong Yanping Xin Tianshu Yu 《Fluid Dynamics & Materials Processing》 EI 2023年第1期25-36,共12页
The Mixed Refrigerant(MR)component is an important factor influencing the performances of natural gas lique-faction processes.However,there is a lack of systematic research about the utilization of propane pre-cooled(... The Mixed Refrigerant(MR)component is an important factor influencing the performances of natural gas lique-faction processes.However,there is a lack of systematic research about the utilization of propane pre-cooled(C3/MRC).In this paper,this mixed refrigerant cycle liquefaction process is simulated using the HYSYS software and the main influential parameters involved in the process are varied to analyze their influence on the liquefaction rate and power consumption.The results show that an effective way for lowering the power consumption of the compressor consists of reducing the flow through the compressor through optimization of the percentage of mixed refrigerant.The power consumption of the compressor in the hybrid refrigeration process is affected by both flow and pressure ratios.Its specific power consumption can be reduced by increasing the flow and decreasing the pressure ratio at the same time.The increase in refrigerant pressure at the high-pressure end can significantly mitigate the energy loss of the heat exchanger and compressor. 展开更多
关键词 refrigerANT C3/MRC process liquefaction performance power consumption pressure ratio hybrid refrigeration process
下载PDF
Effect of an Internal Heat Exchanger on the Performances of a Double Evaporator Ejector Refrigeration Cycle
10
作者 Rachedi Khadraoui Latra Boumaraf Philippe Haberschill 《Fluid Dynamics & Materials Processing》 EI 2023年第5期1115-1128,共14页
A theoretical investigation is presented about a double evaporator ejector refrigeration cycle(DEERC).Special attention is paid to take into account the influence of the sub-cooling and superheating effects induced by... A theoretical investigation is presented about a double evaporator ejector refrigeration cycle(DEERC).Special attention is paid to take into account the influence of the sub-cooling and superheating effects induced by an internal heat exchanger(IHX).The ejector is introduced into the baseline cycle in order to mitigate the throttling process losses and increase the compressor suction pressure.Moreover,the IHX has the structure of a concentric counter-flow type heat exchanger and is intentionally used to ensure that the fluid at the compressor inlet is vapor.To assess accurately the influence of the IHX on the DEERC performance,a mathematical model is derived in the frame of the dominant one-dimensional theory for ejectors.The model also accounts for the friction effect in the ejector mixing section.The equations of this model are solved using an Engineering Equation Solver(EES)for different fluids.These are:R134a as baseline fluid and other environment friendly refrigerants used for comparison,namely,R1234yf,R1234ze,R600,R600a,R290,R717 and R1270.The simulation results show that the DEERC with an IHX can achieve COP(the coefficient of performance)improvements from 5.2 until 10%. 展开更多
关键词 refrigeration cycle double evaporator EJECTOR IHX performance improvement environment-friendlyrefrigerants
下载PDF
The Non-flammable Skin of Our Textiles
11
作者 Feng Yuan 《China Textile》 2007年第8期49-49,共1页
Do you know that even our curtains and table clothes have skins? They might be invisible to our naked eyes, however they do exist, and also, protect us.
关键词 very The non-flammable Skin of Our Textiles
下载PDF
Performance optimization on finite-time quantum Carnot engines and refrigerators based on spin-1/2 systems driven by a squeezed reservoir
12
作者 刘浩广 何济洲 王建辉 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第3期147-152,共6页
We investigate the finite-time performance of a quantum endoreversible Carnot engine cycle and its inverse operation-Carnot refrigeration cycle,employing a spin-1/2 system as the working substance.The thermal machine ... We investigate the finite-time performance of a quantum endoreversible Carnot engine cycle and its inverse operation-Carnot refrigeration cycle,employing a spin-1/2 system as the working substance.The thermal machine is alternatively driven by a hot boson bath of inverse temperatureβ_(h)and a cold boson bath at inverse temperatureβ_(c)(>βh).While for the engine model the hot bath is constructed to be squeezed,in the refrigeration cycle the cold bath is established to be squeezed,with squeezing parameter r.We obtain the analytical expressions for both efficiency and power in heat engines and for coefficient of performance and cooling rate in refrigerators.We find that,in the high-temperature limit,the efficiency at maximum power is bounded by the analytical valueη_(+)=√sech(2r)(1-η_(C)),and the coefficient of performance at the maximum figure of merit is limited byε_(+)=√sech(2r)(1+ε_(C))/sech(2r)(1+ε_(C))-εC)-1,whereη_(C)=1-β_(h)/β_(c)andε_(C)=β_(h)/(β_(c)-β_(h))are the respective Carnot values of the engines and refrigerators.These analytical results are identical to those obtained from the Carnot engines based on harmonic systems,indicating that the efficiency at maximum power and coefficient at maximum figure of merit are independent of the working substance. 展开更多
关键词 performance optimization squeezed bath quantum Carnot engine quantum Carnot refrigerator
下载PDF
Neural Network Model for Boiling Heat Transfer of R22 and Its Alternative Refrigerants inside Horizontal Smooth Tubes
13
作者 王微涓 张春路 《Journal of Shanghai Jiaotong university(Science)》 EI 2005年第1期76-79,共4页
Accurate prediction of refrigerant boiling heat transfer coefficients is important for the design of evaporators. The generalized correlations have different forms, and could not provide satisfactory results for R22 a... Accurate prediction of refrigerant boiling heat transfer coefficients is important for the design of evaporators. The generalized correlations have different forms, and could not provide satisfactory results for R22 and its alternative refrigerants R134a, R407C and R410A. This study proposes to use artificial neural network (ANNs) as a generalized correlation model, selects the input parameters of ANNs on the basis of the dimensionless parameter groups of existing correlations, and correlates the in-tube boiling heat transfer coefficients of the above four refrigerants. The results show that the ANNs model with the input and output based on the Liu-Winterton correlation has the best result. The root-mean-square deviations in training and test are 15.5% and 20.2% respectively, and approximately 85% of the deviations are within ±20%, which is much better than that of the existing generalized correlations. 展开更多
关键词 致冷剂 光滑管道 沸腾热传热 相关性 神经网络
下载PDF
Performance Analysis of a Solar Continuous Adsorption Refrigeration System
14
作者 Kolthoum Missaoui Nader Frikha +2 位作者 Abdelhamid Kheiri Slimane Gabsi Mohammed El Ganaoui 《Fluid Dynamics & Materials Processing》 EI 2023年第4期1067-1081,共15页
A study is conducted on the performances of a solar powered continuous-adsorption refrigerator considering two particular days as references cases,namely,the summer solstice(June 21st)and the autumn equinox(September ... A study is conducted on the performances of a solar powered continuous-adsorption refrigerator considering two particular days as references cases,namely,the summer solstice(June 21st)and the autumn equinox(September 21st).The cooling capacity,system performance coefficient and the daily rate of available cooling energy are assessed.The main goal is to compare the performances of a solar adsorption chiller equipped with a hot water tank(HWT)with an equivalent system relying on solar collectors with no heat storage module.The daily cooling rates for the solar refrigerator are found to be 102.4 kWh and 74.3 kWh,respectively,on June 21st and on September 21st,using a total collector’s area of 43.47 m2.The corresponding values for the adsorption chiller equipped with a hot water tank of 2 m3(and using a total collector’s area of 72.45 m2),are 127.1 kWh and 106.13 kWh,respectively. 展开更多
关键词 Solar continuous adsorption refrigerator dynamic energetic study system performance hot water tank CPC collector thorough system variable heat source
下载PDF
Needs of thermodynamic properties measurements and modeling in the frame of new regulations on refrigerants
15
作者 COQUELET Christophe RICHON Dominique 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2007年第5期724-733,共10页
In 1987, the Montreal Protocol prohibited the worldwide use and production of chlorofluorocarbons (CFCs) and hydrochlorofluorocarbons (HCFCs) and hydro fluorocarbons (HFCs) were proposed as alternative refrigerants. U... In 1987, the Montreal Protocol prohibited the worldwide use and production of chlorofluorocarbons (CFCs) and hydrochlorofluorocarbons (HCFCs) and hydro fluorocarbons (HFCs) were proposed as alternative refrigerants. Unfortunately, HFCs have non negligible global warning potential and therefore new refrigerants must be proposed or old refrigerants must be used associated with HFC. Accurate experimental thermodynamic data and predictive techniques are required for better under-standing of the performance of the newly proposed refrigerants. In this communication, experimental techniques based on either analytic or synthetic methods are first described. Data are reported. Then two newly developed predictive models based on thermodynamic approach with the isofugacity criterion and artificial neural network method are presented. The results can provide better evaluation of refrigerants, especially with the aim of studying global warning effects. 展开更多
关键词 替代制冷剂 法规框架 热力学性质 测量 模型
下载PDF
Establishment of a Model for the Calculation of the COP of a Solar Adsorption Refrigerator
16
作者 Amadou Konfe Gilbert G. Nana +1 位作者 Salif Ouedraogo Sié Kam 《Smart Grid and Renewable Energy》 2023年第11期197-208,共12页
This paper deals with the evaluation of the Coefficient of Performance (COP) of solar adsorption refrigeration. In the literature, simulation models to predict the thermal behaviour and the coefficient of performance ... This paper deals with the evaluation of the Coefficient of Performance (COP) of solar adsorption refrigeration. In the literature, simulation models to predict the thermal behaviour and the coefficient of performance of these systems are uncommon. This is why we suggest a model to simulate the operation of the machine in a typical hot and dry climate of the city of Ouagadougou. The objective is to provide a model for calculating the COP from the measurement of the ambient temperature and the irradiation of a given site. Starting from mathematical modelling, a resolution and simulation were made with COMSOL software based on the Dubinin-Astakhov adsorption model, the heat transfer balance equations, and the Linear Driving Force (LDF) model to describe the thermal behaviour of the system. A one-week measurement sequence on the adsorption solar refrigerator at the Albert Schweitzer Ecological Centre (CEAS) validated the numerical results. The measurement shows that for the days with high sunshine, the temperature of the reaction medium reaches 110°C, and the pressure reaches 500 mbar. This leads to a production of cold that allows it to reach the temperature of -5°C at the evaporator. Under these conditions, the COP is worth 14%. These results are obtained both by numerical simulation using the COMSOL 5.1 software and after a measurement session on the solar refrigerator available to the CEAS. We obtained an experimental and theoretical coefficient of performance varying between 9% and 14% with a difference of between 0% and 3%. We conclude that our model is suitable to estimate the COP of any device based on its thermal properties, the ambient temperature and the irradiation of a given site. 展开更多
关键词 SOLAR refrigerATION ADSORPTION Coefficient of Performance Modelling
下载PDF
新型低GWP制冷剂在-100~200℃的应用研究进展
17
作者 张迪 郭智恺 +4 位作者 于万金 卢朋 刘瑶瑶 刘武灿 张建君 《制冷学报》 CAS CSCD 北大核心 2024年第3期23-37,共15页
制冷剂是蒸气压缩循环中必不可少的工作流体,氢氟烷烃类化合物是目前制冷、空调和热泵设备中的主要制冷剂,但该类制冷剂会引起全球变暖等问题,因此亟需开发应用性能相似、环境性能友好的新型制冷剂。介绍了不同制冷剂在-100~200℃蒸气... 制冷剂是蒸气压缩循环中必不可少的工作流体,氢氟烷烃类化合物是目前制冷、空调和热泵设备中的主要制冷剂,但该类制冷剂会引起全球变暖等问题,因此亟需开发应用性能相似、环境性能友好的新型制冷剂。介绍了不同制冷剂在-100~200℃蒸气压缩循环应用场景中的使用现状,并综述了具有前景的低GWP制冷剂替代方案研究进展;在此基础上,对HFO-1234yf、HFO-1234ze(E)、HFO-1234ze(Z)、HCFO-1233zd(E)、HFO-1336mzz(Z) 5种低GWP制冷剂在实际应用系统中的最新研究及关键问题进行总结。 展开更多
关键词 制冷剂 空调 热泵 有机朗肯循环 GWP
下载PDF
欧盟PFAS限制提案解读及其对制冷空调行业影响与应对
18
作者 安青松 侯佳鑫 +1 位作者 史琳 戴晓业 《制冷学报》 CAS CSCD 北大核心 2024年第2期22-29,共8页
在《〈关于消耗臭氧层物质的蒙特利尔议定书〉基加利修正案》的履约和“双碳”目标的双重驱动下,制冷剂替代是制冷空调领域最为关注的热点之一。采用热物性相近的低GWP的HFOs制冷剂和天然制冷剂作为替代品,实现HFCs的削减被认为是较为... 在《〈关于消耗臭氧层物质的蒙特利尔议定书〉基加利修正案》的履约和“双碳”目标的双重驱动下,制冷剂替代是制冷空调领域最为关注的热点之一。采用热物性相近的低GWP的HFOs制冷剂和天然制冷剂作为替代品,实现HFCs的削减被认为是较为合适的替代技术路线;但随着2023年2月欧盟出台的PFAS限制提案,引发了对HFOs制冷剂替代前景的担忧,这可能影响全球制冷剂替代发展。因此,首先对PFAS物质进行了介绍,分析了含氟制冷剂与PFASs的关系,并对PFAS法案的形成脉络和关键内容进行了解读,总结了不同领域对此的观点,希望对未来制冷剂替代方案的制定提供一定思辨意义和参考价值。 展开更多
关键词 制冷剂替代 欧盟PFAS法案 PFASs HFOs 基加利修正案
下载PDF
制冷与空调专业课程的课程思政教学实践
19
作者 欧阳新萍 刘妮 《高教学刊》 2024年第6期123-126,共4页
培养一流人才,既要高水平地传授专业知识,也要进行“立德树人”的全要素培养。课程思政教学是实现“立德树人”教育的重要途径。课程思政是时代要求,符合马克思主义教育哲学思想,契合先进的教育理念,也是中国优秀传统教育文化的传承。... 培养一流人才,既要高水平地传授专业知识,也要进行“立德树人”的全要素培养。课程思政教学是实现“立德树人”教育的重要途径。课程思政是时代要求,符合马克思主义教育哲学思想,契合先进的教育理念,也是中国优秀传统教育文化的传承。课程思政题材内涵十分丰富,各类专业课程应挖掘出与课程内容紧密贴合的富有特色的思政元素。制冷与空调专业课程制冷设备和空气调节工程的思政元素聚焦于能源的现状及发展、全球气候变暖、“双碳”战略和“中国制造”等题材,达到良好的思政教学效果。课程思政教学也应探索先进的教学方式,以达到满意的教学效果。 展开更多
关键词 课程思政 立德树人 制冷与空调 制冷设备 空气调节工程
下载PDF
涡轮压缩膨胀机的设计与性能分析
20
作者 田雨 马国远 +2 位作者 刘帅领 许树学 周峰 《制冷学报》 CAS CSCD 北大核心 2024年第1期18-27,共10页
随着人们环境保护意识的加强,天然工质制冷剂重新受到研究人员的关注。空气是一种安全且对环境绝对友好的天然制冷剂,未来,压缩空气制冷循环有望成为传统蒸气压缩制冷循环的潜在替代品。压缩膨胀机作为压缩空气制冷的核心部件,其工作效... 随着人们环境保护意识的加强,天然工质制冷剂重新受到研究人员的关注。空气是一种安全且对环境绝对友好的天然制冷剂,未来,压缩空气制冷循环有望成为传统蒸气压缩制冷循环的潜在替代品。压缩膨胀机作为压缩空气制冷的核心部件,其工作效率对机组性能有直接影响。为了设计出能够配合膨胀机高效工作的离心压缩机,需要对传统的设计方法进行一些修正。本文将质量、动量、能量守恒与射流尾迹区理论相结合,并将传统的离心压缩机相关参数推广到较低压力的范围中,提出了一种与现有的涡轮膨胀机相匹配的离心压缩机几何参数的设计方法。使用该方法为现有的膨胀机设计了对应的离心压缩机,并利用其他学者分析过的离心压缩机模型对该方法进行验证,利用计算流体力学方法(CFD)对压缩膨胀机变工况下的工作性能及对膨胀功的利用率进行模拟分析。按本方法设计的离心压缩机在设计工况下能够以高于92%的效率利用膨胀机的输出功。在变工况条件下能够以高于88%的效率利用膨胀机的输出功,并且在设计质量流量附近能够顺利运行。 展开更多
关键词 空气压缩制冷 压缩膨胀机 离心压缩机设计 膨胀功利用率
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部