Social robot accounts controlled by artificial intelligence or humans are active in social networks,bringing negative impacts to network security and social life.Existing social robot detection methods based on graph ...Social robot accounts controlled by artificial intelligence or humans are active in social networks,bringing negative impacts to network security and social life.Existing social robot detection methods based on graph neural networks suffer from the problem of many social network nodes and complex relationships,which makes it difficult to accurately describe the difference between the topological relations of nodes,resulting in low detection accuracy of social robots.This paper proposes a social robot detection method with the use of an improved neural network.First,social relationship subgraphs are constructed by leveraging the user’s social network to disentangle intricate social relationships effectively.Then,a linear modulated graph attention residual network model is devised to extract the node and network topology features of the social relation subgraph,thereby generating comprehensive social relation subgraph features,and the feature-wise linear modulation module of the model can better learn the differences between the nodes.Next,user text content and behavioral gene sequences are extracted to construct social behavioral features combined with the social relationship subgraph features.Finally,social robots can be more accurately identified by combining user behavioral and relationship features.By carrying out experimental studies based on the publicly available datasets TwiBot-20 and Cresci-15,the suggested method’s detection accuracies can achieve 86.73%and 97.86%,respectively.Compared with the existing mainstream approaches,the accuracy of the proposed method is 2.2%and 1.35%higher on the two datasets.The results show that the method proposed in this paper can effectively detect social robots and maintain a healthy ecological environment of social networks.展开更多
Liver fibrosis is an important pathological precondition for hepatocellular carcinoma.The degree of hepatic fibrosis is positively correlated with liver cancer.Liver fibrosis is a series of pathological and physiologi...Liver fibrosis is an important pathological precondition for hepatocellular carcinoma.The degree of hepatic fibrosis is positively correlated with liver cancer.Liver fibrosis is a series of pathological and physiological process related to liver cell necrosis and degeneration after chronic liver injury,which finally leads to extracellular matrix and collagen deposition.The early detection and precise staging of fibrosis and cirrhosis are very important for early diagnosis and timely initiation of appropriate therapeutic regimens.The risk of severe liver fibrosis finally progressing to liver carcinoma is>50%.It is known that biopsy is the gold standard for the diagnosis and staging of liver fibrosis.However,this method has some limitations,such as the potential for pain,sampling variability,and low patient acceptance.Furthermore,the necessity of obtaining a tissue diagnosis of liver fibrosis still remains controversial.An increasing number of reliable non-invasive approaches are now available that are widely applied in clinical practice,mostly in cases of viral hepatitis,resulting in a significantly decreased need for liver biopsy.In fact,the noninvasive detection and evaluation of liver cirrhosis now has good accuracy due to current serum markers,ultrasound imaging,and magnetic resonance imaging quantification techniques.A prominent advantage of the non-invasive detection and assessment of liver fibrosis is that liver fibrosis can be monitored repeatedly and easily in the same patient.Serum biomarkers have the advantages of high applicability(〉95%)and good reproducibility.However,their results can be influenced by different patient conditions because none of these markers are liver-specific.The most promising techniques appear to be transient elastography and magnetic resonance elastography because they provide reliable results for the detection of fibrosis in the advanced stages,and future developments promise to increase the reliability and accuracy of the staging of hepatic fibrosis.This article aims to describe the recent progress in the development of non-invasive assessment methods for the staging of liver fibrosis,with a special emphasize on computer-aided quantitative and deep learning methods.展开更多
[Objective] This study aimed to investigate the prevalence and variation of porcine kobuvirus (PKV) in suckling piglets in China. [Method] In 2013-2014, 224 feces samples from suckling piglets with diarrhea in 27 pi...[Objective] This study aimed to investigate the prevalence and variation of porcine kobuvirus (PKV) in suckling piglets in China. [Method] In 2013-2014, 224 feces samples from suckling piglets with diarrhea in 27 pig farms of five provinces in China were collected to detect 3D genes of PKV with RT-PCR method; the sequences and genetic variation of 29 PKV 3D genes were analyzed. [Result] Total positive rate of PKV in feces samples from suckling piglets with diarrhea was 65.18% (146/224); total positive rate of PKV in pig farms was 85,2% (23/27); nucleotide sequences and the deduced amino acid sequences of 29 PKV 3D genes shared 87.0%-100% and 92.7%-100% homologies with six PKV-related 3D sequences, respectively. [Conclusion] PKV infection is prevalent in suckling piglets in China; PKV 3D genes exhibit high diversity.展开更多
Objective The study is to identify the carrier rate of common deafness mutation in Chinese pregnant women via detecting deafness gene mutations with gene chip. Methods The pregnant women in obstetric clinic without he...Objective The study is to identify the carrier rate of common deafness mutation in Chinese pregnant women via detecting deafness gene mutations with gene chip. Methods The pregnant women in obstetric clinic without hearing impairment and hearing disorders family history were selected. The informed consent was signed. Peripheral blood was taken to extract genom- ic DNA. Application of genetic deafness gene chip for detecting 9 mutational hot spot of the most common 4 Chinese deafness genes, namely GJB2 (35delG, 176del16bp, 235delC, 299delAT), GJB3 (C538T) ,SLC26A4 ( IVS72A〉G, A2168G) and mito- chondrial DNA 12S rRNA (A1555G, C1494T) . Further genetic testing were provided to the spouses and newborns of the screened carriers. Results Peripheral blood of 430 pregnant women were detected, detection of deafness gene mutation carri- ers in 24 cases(4.2%), including 13 cases of the GJB2 heterozygous mutation, 3 cases of SLC26A4 heterozygous mutation, 1 cases of GJB3 heterozygous mutation, and 1 case of mitochondrial 12S rRNA mutation. 18 spouses and 17 newborns took further genetic tests, and 6 newborns inherited the mutation from their mother. Conclusion The common deafness genes muta- tion has a high carrier rate in pregnant women group, 235delC and IVS7-2A〉G heterozygous mutations are common.展开更多
Objective To detect the specific mutations in rpoB gene of Mycobacterium tuberculosis by oligonucleotide microarray. Methods Four wild-type and 8 mutant probes were used to detect rifampin resistant strains. Target DN...Objective To detect the specific mutations in rpoB gene of Mycobacterium tuberculosis by oligonucleotide microarray. Methods Four wild-type and 8 mutant probes were used to detect rifampin resistant strains. Target DNA of M. tuberculosis was amplified by PCR, hybridized and scanned. Direct sequencing was performed to verify the results of oligonucleotide microarray Results Of the 102 rifampin-resistant strains 98 (96.1%) had mutations in the rpoB genes. Conclusion Oligonucleotide microarray with mutation-specific probes is a reliable and useful tool for the rapid and accurate diagnosis of rifampin resistance in M. tuberculosis isolates.展开更多
In China, the purity of maize hybrid strain is discomforting to the development of seed industrialization. Finding a new method for reproduction of maize hybrid strain is necessary. In this study, using particle bomba...In China, the purity of maize hybrid strain is discomforting to the development of seed industrialization. Finding a new method for reproduction of maize hybrid strain is necessary. In this study, using particle bombardment, barstar gene was transferred into maize inbred line 18-599 (White), which is an antiviral and high quality maize inbred line. By molecular detection of the anther of transgenic maize, two plants transferred with barstar gene were gained in this study, which are two restorer lines. The two plants showed normal male spike, and lively microspores. But the capacity of the two restorer lines should be studied in the future. The aim of this study is to find a new method of reproduction of maize hybrid strain using engineering restorer lines and engineering sterility lines by gene engineering technology.展开更多
Non-invasive prenatal gene diagnosis has been developed rapidly in the recent years, and numerous medical researchers are focusing on it. Such techniques could not only achieve prenatal diagnosis accurately, but also ...Non-invasive prenatal gene diagnosis has been developed rapidly in the recent years, and numerous medical researchers are focusing on it. Such techniques could not only achieve prenatal diagnosis accurately, but also prevent tangential illness in fetuses and thus, reduce the incidence of diseases. Moreover, it is non-invasive prenatal gene diagnosis that prevents potential threaten and danger to both mothers and fetuses. Therefore, it is welcomed by clinical gynecologist and obstetrian, researchers of medical genetics, and especially, pregnancies. This review article touches briefly on the advanced development of using cell-free DNA, RNA in maternal plasma and urine for non-invasive prenatal gene diagnosis.展开更多
Objective: To determine the feasibility of detecting p53 gene mutations for early diagnosis of lung cancer using the samples from bronchoscopic examination. Methods: Point mutations of the exon 5-8 of p53 gene were de...Objective: To determine the feasibility of detecting p53 gene mutations for early diagnosis of lung cancer using the samples from bronchoscopic examination. Methods: Point mutations of the exon 5-8 of p53 gene were detected in 85 bronchoscopic samples of 35 patients suspected to be lung cancer using silver staining PCR-SSCP. Results: p53 gene mutations were founded in 10 of 35 patients(28.6%). The incidence of p53 gene mutations (14.9%) was obviously higher than the cytological positive incidence(2.9%) in samples of sputum, bronchoalveolar lavage and brush, especially for the sputum(27.7%). In the bronchoscopic biopsy specimens, the incidence of p53 gene mutations (12.5%) was lower than that of pathologic positive result (50.0%). However, in view of all the bronchoscopic samples, there was no statistically difference between cytopathologic positive results (11.8%) and the incidence of p53 gene mutations (14.1%). Although the p53 mutations were most common in the samples from the patients bronchoscopically manifested as neoplasm compared with other manifestations, there was no statistical difference. It is valuable to notice that 3 patients with p53 gene mutation merely presented as bronchial inflammation in bronchoscope. Conclusion: Results indicated that the value of detecting p53 gene mutation for the diagnosis of lung cancer using the bronchoscopic samples was more superior to cytological examination and detection of p53 gene mutations in post-bronchoscopic sputum was easy and effective, may be used as a valuable method for early diagnosis of lung cancer.展开更多
Lung cancer remains a significant global health challenge and identifying lung cancer at an early stage is essential for enhancing patient outcomes. The study focuses on developing and optimizing gene expression-based...Lung cancer remains a significant global health challenge and identifying lung cancer at an early stage is essential for enhancing patient outcomes. The study focuses on developing and optimizing gene expression-based models for classifying cancer types using machine learning techniques. By applying Log2 normalization to gene expression data and conducting Wilcoxon rank sum tests, the researchers employed various classifiers and Incremental Feature Selection (IFS) strategies. The study culminated in two optimized models using the XGBoost classifier, comprising 10 and 74 genes respectively. The 10-gene model, due to its simplicity, is proposed for easier clinical implementation, whereas the 74-gene model exhibited superior performance in terms of Specificity, AUC (Area Under the Curve), and Precision. These models were evaluated based on their sensitivity, AUC, and specificity, aiming to achieve high sensitivity and AUC while maintaining reasonable specificity.展开更多
The immature embryos of wheat cultivars Liaochun10, Tiechun1 and Fengqiang3 were bombarded with gold particles coated with pti5 vp16 by gene gun and disease resistant regenerated plants were attained. In order to...The immature embryos of wheat cultivars Liaochun10, Tiechun1 and Fengqiang3 were bombarded with gold particles coated with pti5 vp16 by gene gun and disease resistant regenerated plants were attained. In order to confirm that the plants are genuine transformed ones, a series of molecular tests were conducted as follows. Firstly, transient GUS expression test on embryos two days after bombardment was done. There were many obvious blue spots produced on the surface of bombarded embryos after GUS staining, in which the maximum reached to 85 blue spots per embryo. Secondly, PCR test was performed with DNA from the regenerated plants obtained after double selection with ppt. 6 plants were found PCR test positive. At last, further verification analysis using dot hybridization and southern blotting was carried out on those PCR positive plants and the strong hybridization signals appeared as expected. All the above tests were uniformly indicated that the disease resistant regenerated plants were true transgenic plants. When inoculated with Blumeria graminis, transgenic wheat plants of PCR positive results were mostly resistant(R) after 7 days, and resis tant, moderate resistant(MR), moderate susceptible(MS) at 14 days respectively. The disease severity of them was distinctively lighter than that of control.展开更多
We applied the Agilent 2100 Bioanalyzer, a microfluidics-based electrophoresis instrument, and introduced an accurate and consistent parameter, the relative product yield ratio (ROY), to detect somatic gene deletions ...We applied the Agilent 2100 Bioanalyzer, a microfluidics-based electrophoresis instrument, and introduced an accurate and consistent parameter, the relative product yield ratio (ROY), to detect somatic gene deletions in tumor cells. Briefly for such purpose, the Agilent 2100 Bioanalyzer quantified the ROY of a target gene to an endogenous internal control, both of which were initially co-amplified by Robust-Dosage PCR (RD- PCR). Herein, we extensively validated this approach. We first tested the effect of well positions on the Agilent DNA chip. We found that no matter which wells the samples were loaded in, the ROY was consistent with coefficient of variation (CV) < 2%. Then we tested the effect of product concentrations that varied 8-fold, and the ROY was also consistent with CV < 3.5%. Furthermore, we applied this approach to identify six somatic KRAS deletions in non-small cell lung cancer patients, confirming our previous findings. Thus, the Agilent 2100 Bioanalyzer is simple, accurate, quick, and ultimately able to replace conventional gel electrophoresis for the detection of somatic gene deletions.展开更多
Using PCR-denaturing gradient gel electrophoresis (DGGE) targeting the RNA polymerase beta subunit (rpoB) gene, a simultaneous detection method for Vibrio species was established, rpoB gene-based PCR-DGGE was carr...Using PCR-denaturing gradient gel electrophoresis (DGGE) targeting the RNA polymerase beta subunit (rpoB) gene, a simultaneous detection method for Vibrio species was established, rpoB gene-based PCR-DGGE was carried out with eight Vibrio reference strains (each from different species), mixed sample (including these Vibrio reference strains), two non Vibrio strains, four environmental Vibrio strains, and three unidentified environmental strains. For comparison, 16S rRNA gene-based PCR-DGGE of the eight Vibrio reference strains was performed with universal primers. In addition, three unidentified strains were identified by 16S rRNA and gyrB gene sequencing and API20E system in order to confirm the accuracy of rpoB gene-based PCR-DGGE detection. Results revealed that rpoB-based PCR-DGGE could well discriminate eight Vibrio reference strains and could not discriminate different strains within the same species. The bands derived from two non Vibrio strains could not match with any bands in reference marker. Meanwhile, 16S rRNA gene-based DGGE failed to distinguish these reference strains. Further-more, four out of eight Vibrio species exhibited heterogenous bands in 16S rRNA gene-based DGGE. Sequencing and API 20E identification of unidentified strains coincided with the detection by rpoB gene-based PCR-DGGE. The results demonstrated that rpoB-based PCR-DGGE provided a rapid and efficient method for simultaneous detection of muhiple Vibrio species, which can avoid the limitations inherent in 16S rRNA gene-based PCR-DGGE.展开更多
When the loop-mediated isothermal amplification(LAMP)assay is used for detecting target genes,DNA extraction is unnecessary in many cases.Simple pretreatment(e.g.heating)is enough to obtain rather sensitive responses....When the loop-mediated isothermal amplification(LAMP)assay is used for detecting target genes,DNA extraction is unnecessary in many cases.Simple pretreatment(e.g.heating)is enough to obtain rather sensitive responses.Even test samples without any pretreatment can be used as template.This feature suggests that LAMP is superior to PCR in developing point-of-care test strategies.In this study,using Stx1 gene from E.coli as model,we verified that viable cells,dead cells and extracellular DNA could function as template in the LAMP assay.In the incubation at 63℃,viable bacteria in the LAMP reaction mixture lysed completely within 2 min,providing DNA template for nucleic acid amplification.The Stx1 gene in diluted culture medium,spiked tap water,spiked seawater and real seawater all could be detected,with or without the step of DNA extraction.We found that the complex substances in real sample(e.g.natural seawater)exhibited considerable inhibitory effect on the sensitivity of the LAMP assay.These outcomes are meaningful for building a point-of-care strategy by employing the LAMP assay for environmental monitoring,bio-resource surveys,food safety,etc.in particular those based on environmental DNA.展开更多
With gene engineering EB virus membrane antigen as the diagnostic antigen, indirect immunofluo-rescence (IF) assay was used to detect IgA antibody against EB virus membrane antigen (MA-IgA) in sera from 202 nasopharyn...With gene engineering EB virus membrane antigen as the diagnostic antigen, indirect immunofluo-rescence (IF) assay was used to detect IgA antibody against EB virus membrane antigen (MA-IgA) in sera from 202 nasopharyngeal carcinoma (NPC) patients and 315 controls (normal and patients with other tumors). MA-IgA antibody was positive in 96.8% of the pretreatment NPC patients with a GMT of 1:36.3. MA-IgA detection by this method was more sensitive than EA-IgA detection by IE. In contrast, patients with tumors other than NPC were negative for MA-IgA antibody. 9.1% of VCA-IgA positive persons were MA-IgA positive with a GMT of less than 1:5. No MA-IgA positive was found in VCA-IgA negatives. The results indicated that this method was relatively specific. In the treatment group, the positive rate and GMT of MA-IgA antibody declined with increase in survival time and the decline was faster than VCA-IgA. When recurrence or distant metastasis developed, similar to VCA-IgA and EA-IgA antibodies, the positive rate and GMT of MA-IgA antibody increased to its pretreatment level. Therefore, MA-IgA detection might be valuable in the early diagnosis and monitor of NPC.展开更多
Objective:To study the refractory factors associated with schizophrenia.Methods: 200 patients with refractory schizophrenia and 200 patients with non-refractory schizophrenia were selected. The CYP series of genes CYP...Objective:To study the refractory factors associated with schizophrenia.Methods: 200 patients with refractory schizophrenia and 200 patients with non-refractory schizophrenia were selected. The CYP series of genes CYP1A2, CYP3A4 and CYP2D6 were detected by drug gene, and the rapid metabolic probabilities of the three genes were compared and analyzed. 200 patients with refractory schizophrenia were randomly divided into two groups: the combined drug treatment group and the single drug treatment group. The results were compared between the treatment of 0W and 4W for drug gene detection, 3 genes fast metabolizing type and BPRS scale. analysis.Results: The rapid metabolizing probability and non-refractory difference of CYP1A2, CYP3A4 and CYP2D6 genes in patients with refractory schizophrenia were significant. The comparison of fast metabotropic probabilities of CYP1A2, CYP3A4 and CYP2D6 genes in patients treated with 4W after treatment There was no significant difference in the single drug treatment group. The BPRS scale score was significantly higher in the drug-treated group than in the single-drug group. After logistic regression analysis, the refractory characteristics of schizophrenia and The CYP series of genes CYP1A2, CYP3A4, and CYP2D6 are rapidly metabolized.Conclusion: CYP series of genes CYP1A2, CYP3A4, CYP2D6 fast metabolites are related factors of refractory schizophrenia, antipsychotic drugs combined with CYP enzyme inhibitor treatment can improve the efficacy.展开更多
Objective:To explore a method to solve the issue of interference in fluorescence quantitative PCR non-specific amplification for gene detection.Method:A three-step method was used for amplification,and the quantitativ...Objective:To explore a method to solve the issue of interference in fluorescence quantitative PCR non-specific amplification for gene detection.Method:A three-step method was used for amplification,and the quantitative fluorescence signal collection process was set in the extension stage.Results:Three-step amplification has the advantages of wide application range;improved accuracy;and reduced primer design requirements.Conclusion:The interference of non-specific amplification signals was effectively avoided,the melting curve plotting process was omitted,the reaction time was shortened,and the detection accuracy was improved.展开更多
基金This work was supported in part by the National Natural Science Foundation of China under Grants 62273272,62303375 and 61873277in part by the Key Research and Development Program of Shaanxi Province under Grant 2023-YBGY-243+2 种基金in part by the Natural Science Foundation of Shaanxi Province under Grants 2022JQ-606 and 2020-JQ758in part by the Research Plan of Department of Education of Shaanxi Province under Grant 21JK0752in part by the Youth Innovation Team of Shaanxi Universities.
文摘Social robot accounts controlled by artificial intelligence or humans are active in social networks,bringing negative impacts to network security and social life.Existing social robot detection methods based on graph neural networks suffer from the problem of many social network nodes and complex relationships,which makes it difficult to accurately describe the difference between the topological relations of nodes,resulting in low detection accuracy of social robots.This paper proposes a social robot detection method with the use of an improved neural network.First,social relationship subgraphs are constructed by leveraging the user’s social network to disentangle intricate social relationships effectively.Then,a linear modulated graph attention residual network model is devised to extract the node and network topology features of the social relation subgraph,thereby generating comprehensive social relation subgraph features,and the feature-wise linear modulation module of the model can better learn the differences between the nodes.Next,user text content and behavioral gene sequences are extracted to construct social behavioral features combined with the social relationship subgraph features.Finally,social robots can be more accurately identified by combining user behavioral and relationship features.By carrying out experimental studies based on the publicly available datasets TwiBot-20 and Cresci-15,the suggested method’s detection accuracies can achieve 86.73%and 97.86%,respectively.Compared with the existing mainstream approaches,the accuracy of the proposed method is 2.2%and 1.35%higher on the two datasets.The results show that the method proposed in this paper can effectively detect social robots and maintain a healthy ecological environment of social networks.
文摘Liver fibrosis is an important pathological precondition for hepatocellular carcinoma.The degree of hepatic fibrosis is positively correlated with liver cancer.Liver fibrosis is a series of pathological and physiological process related to liver cell necrosis and degeneration after chronic liver injury,which finally leads to extracellular matrix and collagen deposition.The early detection and precise staging of fibrosis and cirrhosis are very important for early diagnosis and timely initiation of appropriate therapeutic regimens.The risk of severe liver fibrosis finally progressing to liver carcinoma is&gt;50%.It is known that biopsy is the gold standard for the diagnosis and staging of liver fibrosis.However,this method has some limitations,such as the potential for pain,sampling variability,and low patient acceptance.Furthermore,the necessity of obtaining a tissue diagnosis of liver fibrosis still remains controversial.An increasing number of reliable non-invasive approaches are now available that are widely applied in clinical practice,mostly in cases of viral hepatitis,resulting in a significantly decreased need for liver biopsy.In fact,the noninvasive detection and evaluation of liver cirrhosis now has good accuracy due to current serum markers,ultrasound imaging,and magnetic resonance imaging quantification techniques.A prominent advantage of the non-invasive detection and assessment of liver fibrosis is that liver fibrosis can be monitored repeatedly and easily in the same patient.Serum biomarkers have the advantages of high applicability(〉95%)and good reproducibility.However,their results can be influenced by different patient conditions because none of these markers are liver-specific.The most promising techniques appear to be transient elastography and magnetic resonance elastography because they provide reliable results for the detection of fibrosis in the advanced stages,and future developments promise to increase the reliability and accuracy of the staging of hepatic fibrosis.This article aims to describe the recent progress in the development of non-invasive assessment methods for the staging of liver fibrosis,with a special emphasize on computer-aided quantitative and deep learning methods.
文摘[Objective] This study aimed to investigate the prevalence and variation of porcine kobuvirus (PKV) in suckling piglets in China. [Method] In 2013-2014, 224 feces samples from suckling piglets with diarrhea in 27 pig farms of five provinces in China were collected to detect 3D genes of PKV with RT-PCR method; the sequences and genetic variation of 29 PKV 3D genes were analyzed. [Result] Total positive rate of PKV in feces samples from suckling piglets with diarrhea was 65.18% (146/224); total positive rate of PKV in pig farms was 85,2% (23/27); nucleotide sequences and the deduced amino acid sequences of 29 PKV 3D genes shared 87.0%-100% and 92.7%-100% homologies with six PKV-related 3D sequences, respectively. [Conclusion] PKV infection is prevalent in suckling piglets in China; PKV 3D genes exhibit high diversity.
文摘Objective The study is to identify the carrier rate of common deafness mutation in Chinese pregnant women via detecting deafness gene mutations with gene chip. Methods The pregnant women in obstetric clinic without hearing impairment and hearing disorders family history were selected. The informed consent was signed. Peripheral blood was taken to extract genom- ic DNA. Application of genetic deafness gene chip for detecting 9 mutational hot spot of the most common 4 Chinese deafness genes, namely GJB2 (35delG, 176del16bp, 235delC, 299delAT), GJB3 (C538T) ,SLC26A4 ( IVS72A〉G, A2168G) and mito- chondrial DNA 12S rRNA (A1555G, C1494T) . Further genetic testing were provided to the spouses and newborns of the screened carriers. Results Peripheral blood of 430 pregnant women were detected, detection of deafness gene mutation carri- ers in 24 cases(4.2%), including 13 cases of the GJB2 heterozygous mutation, 3 cases of SLC26A4 heterozygous mutation, 1 cases of GJB3 heterozygous mutation, and 1 case of mitochondrial 12S rRNA mutation. 18 spouses and 17 newborns took further genetic tests, and 6 newborns inherited the mutation from their mother. Conclusion The common deafness genes muta- tion has a high carrier rate in pregnant women group, 235delC and IVS7-2A〉G heterozygous mutations are common.
基金supported by the grant from the National Natural Science Foundation of China (No. 30400018)
文摘Objective To detect the specific mutations in rpoB gene of Mycobacterium tuberculosis by oligonucleotide microarray. Methods Four wild-type and 8 mutant probes were used to detect rifampin resistant strains. Target DNA of M. tuberculosis was amplified by PCR, hybridized and scanned. Direct sequencing was performed to verify the results of oligonucleotide microarray Results Of the 102 rifampin-resistant strains 98 (96.1%) had mutations in the rpoB genes. Conclusion Oligonucleotide microarray with mutation-specific probes is a reliable and useful tool for the rapid and accurate diagnosis of rifampin resistance in M. tuberculosis isolates.
文摘In China, the purity of maize hybrid strain is discomforting to the development of seed industrialization. Finding a new method for reproduction of maize hybrid strain is necessary. In this study, using particle bombardment, barstar gene was transferred into maize inbred line 18-599 (White), which is an antiviral and high quality maize inbred line. By molecular detection of the anther of transgenic maize, two plants transferred with barstar gene were gained in this study, which are two restorer lines. The two plants showed normal male spike, and lively microspores. But the capacity of the two restorer lines should be studied in the future. The aim of this study is to find a new method of reproduction of maize hybrid strain using engineering restorer lines and engineering sterility lines by gene engineering technology.
文摘Non-invasive prenatal gene diagnosis has been developed rapidly in the recent years, and numerous medical researchers are focusing on it. Such techniques could not only achieve prenatal diagnosis accurately, but also prevent tangential illness in fetuses and thus, reduce the incidence of diseases. Moreover, it is non-invasive prenatal gene diagnosis that prevents potential threaten and danger to both mothers and fetuses. Therefore, it is welcomed by clinical gynecologist and obstetrian, researchers of medical genetics, and especially, pregnancies. This review article touches briefly on the advanced development of using cell-free DNA, RNA in maternal plasma and urine for non-invasive prenatal gene diagnosis.
基金the Research Foundation of the Ministry of Public Health of PR China !(No. 94-1-316).
文摘Objective: To determine the feasibility of detecting p53 gene mutations for early diagnosis of lung cancer using the samples from bronchoscopic examination. Methods: Point mutations of the exon 5-8 of p53 gene were detected in 85 bronchoscopic samples of 35 patients suspected to be lung cancer using silver staining PCR-SSCP. Results: p53 gene mutations were founded in 10 of 35 patients(28.6%). The incidence of p53 gene mutations (14.9%) was obviously higher than the cytological positive incidence(2.9%) in samples of sputum, bronchoalveolar lavage and brush, especially for the sputum(27.7%). In the bronchoscopic biopsy specimens, the incidence of p53 gene mutations (12.5%) was lower than that of pathologic positive result (50.0%). However, in view of all the bronchoscopic samples, there was no statistically difference between cytopathologic positive results (11.8%) and the incidence of p53 gene mutations (14.1%). Although the p53 mutations were most common in the samples from the patients bronchoscopically manifested as neoplasm compared with other manifestations, there was no statistical difference. It is valuable to notice that 3 patients with p53 gene mutation merely presented as bronchial inflammation in bronchoscope. Conclusion: Results indicated that the value of detecting p53 gene mutation for the diagnosis of lung cancer using the bronchoscopic samples was more superior to cytological examination and detection of p53 gene mutations in post-bronchoscopic sputum was easy and effective, may be used as a valuable method for early diagnosis of lung cancer.
文摘Lung cancer remains a significant global health challenge and identifying lung cancer at an early stage is essential for enhancing patient outcomes. The study focuses on developing and optimizing gene expression-based models for classifying cancer types using machine learning techniques. By applying Log2 normalization to gene expression data and conducting Wilcoxon rank sum tests, the researchers employed various classifiers and Incremental Feature Selection (IFS) strategies. The study culminated in two optimized models using the XGBoost classifier, comprising 10 and 74 genes respectively. The 10-gene model, due to its simplicity, is proposed for easier clinical implementation, whereas the 74-gene model exhibited superior performance in terms of Specificity, AUC (Area Under the Curve), and Precision. These models were evaluated based on their sensitivity, AUC, and specificity, aiming to achieve high sensitivity and AUC while maintaining reasonable specificity.
文摘The immature embryos of wheat cultivars Liaochun10, Tiechun1 and Fengqiang3 were bombarded with gold particles coated with pti5 vp16 by gene gun and disease resistant regenerated plants were attained. In order to confirm that the plants are genuine transformed ones, a series of molecular tests were conducted as follows. Firstly, transient GUS expression test on embryos two days after bombardment was done. There were many obvious blue spots produced on the surface of bombarded embryos after GUS staining, in which the maximum reached to 85 blue spots per embryo. Secondly, PCR test was performed with DNA from the regenerated plants obtained after double selection with ppt. 6 plants were found PCR test positive. At last, further verification analysis using dot hybridization and southern blotting was carried out on those PCR positive plants and the strong hybridization signals appeared as expected. All the above tests were uniformly indicated that the disease resistant regenerated plants were true transgenic plants. When inoculated with Blumeria graminis, transgenic wheat plants of PCR positive results were mostly resistant(R) after 7 days, and resis tant, moderate resistant(MR), moderate susceptible(MS) at 14 days respectively. The disease severity of them was distinctively lighter than that of control.
文摘We applied the Agilent 2100 Bioanalyzer, a microfluidics-based electrophoresis instrument, and introduced an accurate and consistent parameter, the relative product yield ratio (ROY), to detect somatic gene deletions in tumor cells. Briefly for such purpose, the Agilent 2100 Bioanalyzer quantified the ROY of a target gene to an endogenous internal control, both of which were initially co-amplified by Robust-Dosage PCR (RD- PCR). Herein, we extensively validated this approach. We first tested the effect of well positions on the Agilent DNA chip. We found that no matter which wells the samples were loaded in, the ROY was consistent with coefficient of variation (CV) < 2%. Then we tested the effect of product concentrations that varied 8-fold, and the ROY was also consistent with CV < 3.5%. Furthermore, we applied this approach to identify six somatic KRAS deletions in non-small cell lung cancer patients, confirming our previous findings. Thus, the Agilent 2100 Bioanalyzer is simple, accurate, quick, and ultimately able to replace conventional gel electrophoresis for the detection of somatic gene deletions.
基金the National Basic Research Programme of China(No.2006CB101803)the National Natural Science Foundation of China(No.30700016)
文摘Using PCR-denaturing gradient gel electrophoresis (DGGE) targeting the RNA polymerase beta subunit (rpoB) gene, a simultaneous detection method for Vibrio species was established, rpoB gene-based PCR-DGGE was carried out with eight Vibrio reference strains (each from different species), mixed sample (including these Vibrio reference strains), two non Vibrio strains, four environmental Vibrio strains, and three unidentified environmental strains. For comparison, 16S rRNA gene-based PCR-DGGE of the eight Vibrio reference strains was performed with universal primers. In addition, three unidentified strains were identified by 16S rRNA and gyrB gene sequencing and API20E system in order to confirm the accuracy of rpoB gene-based PCR-DGGE detection. Results revealed that rpoB-based PCR-DGGE could well discriminate eight Vibrio reference strains and could not discriminate different strains within the same species. The bands derived from two non Vibrio strains could not match with any bands in reference marker. Meanwhile, 16S rRNA gene-based DGGE failed to distinguish these reference strains. Further-more, four out of eight Vibrio species exhibited heterogenous bands in 16S rRNA gene-based DGGE. Sequencing and API 20E identification of unidentified strains coincided with the detection by rpoB gene-based PCR-DGGE. The results demonstrated that rpoB-based PCR-DGGE provided a rapid and efficient method for simultaneous detection of muhiple Vibrio species, which can avoid the limitations inherent in 16S rRNA gene-based PCR-DGGE.
文摘When the loop-mediated isothermal amplification(LAMP)assay is used for detecting target genes,DNA extraction is unnecessary in many cases.Simple pretreatment(e.g.heating)is enough to obtain rather sensitive responses.Even test samples without any pretreatment can be used as template.This feature suggests that LAMP is superior to PCR in developing point-of-care test strategies.In this study,using Stx1 gene from E.coli as model,we verified that viable cells,dead cells and extracellular DNA could function as template in the LAMP assay.In the incubation at 63℃,viable bacteria in the LAMP reaction mixture lysed completely within 2 min,providing DNA template for nucleic acid amplification.The Stx1 gene in diluted culture medium,spiked tap water,spiked seawater and real seawater all could be detected,with or without the step of DNA extraction.We found that the complex substances in real sample(e.g.natural seawater)exhibited considerable inhibitory effect on the sensitivity of the LAMP assay.These outcomes are meaningful for building a point-of-care strategy by employing the LAMP assay for environmental monitoring,bio-resource surveys,food safety,etc.in particular those based on environmental DNA.
文摘With gene engineering EB virus membrane antigen as the diagnostic antigen, indirect immunofluo-rescence (IF) assay was used to detect IgA antibody against EB virus membrane antigen (MA-IgA) in sera from 202 nasopharyngeal carcinoma (NPC) patients and 315 controls (normal and patients with other tumors). MA-IgA antibody was positive in 96.8% of the pretreatment NPC patients with a GMT of 1:36.3. MA-IgA detection by this method was more sensitive than EA-IgA detection by IE. In contrast, patients with tumors other than NPC were negative for MA-IgA antibody. 9.1% of VCA-IgA positive persons were MA-IgA positive with a GMT of less than 1:5. No MA-IgA positive was found in VCA-IgA negatives. The results indicated that this method was relatively specific. In the treatment group, the positive rate and GMT of MA-IgA antibody declined with increase in survival time and the decline was faster than VCA-IgA. When recurrence or distant metastasis developed, similar to VCA-IgA and EA-IgA antibodies, the positive rate and GMT of MA-IgA antibody increased to its pretreatment level. Therefore, MA-IgA detection might be valuable in the early diagnosis and monitor of NPC.
基金Hainan Natural Science Foundation(Item Number 20168325).
文摘Objective:To study the refractory factors associated with schizophrenia.Methods: 200 patients with refractory schizophrenia and 200 patients with non-refractory schizophrenia were selected. The CYP series of genes CYP1A2, CYP3A4 and CYP2D6 were detected by drug gene, and the rapid metabolic probabilities of the three genes were compared and analyzed. 200 patients with refractory schizophrenia were randomly divided into two groups: the combined drug treatment group and the single drug treatment group. The results were compared between the treatment of 0W and 4W for drug gene detection, 3 genes fast metabolizing type and BPRS scale. analysis.Results: The rapid metabolizing probability and non-refractory difference of CYP1A2, CYP3A4 and CYP2D6 genes in patients with refractory schizophrenia were significant. The comparison of fast metabotropic probabilities of CYP1A2, CYP3A4 and CYP2D6 genes in patients treated with 4W after treatment There was no significant difference in the single drug treatment group. The BPRS scale score was significantly higher in the drug-treated group than in the single-drug group. After logistic regression analysis, the refractory characteristics of schizophrenia and The CYP series of genes CYP1A2, CYP3A4, and CYP2D6 are rapidly metabolized.Conclusion: CYP series of genes CYP1A2, CYP3A4, CYP2D6 fast metabolites are related factors of refractory schizophrenia, antipsychotic drugs combined with CYP enzyme inhibitor treatment can improve the efficacy.
文摘Objective:To explore a method to solve the issue of interference in fluorescence quantitative PCR non-specific amplification for gene detection.Method:A three-step method was used for amplification,and the quantitative fluorescence signal collection process was set in the extension stage.Results:Three-step amplification has the advantages of wide application range;improved accuracy;and reduced primer design requirements.Conclusion:The interference of non-specific amplification signals was effectively avoided,the melting curve plotting process was omitted,the reaction time was shortened,and the detection accuracy was improved.