期刊文献+
共找到2,361篇文章
< 1 2 119 >
每页显示 20 50 100
Vibration attenuation performance of wind turbine tower using a prestressed tuned mass damper under seismic excitation
1
作者 Lei Zhenbo Liu Gang +1 位作者 Wang Hui Hui Yi 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2024年第2期511-524,共14页
With the rapid development of large megawatt wind turbines,the operation environment of wind turbine towers(WTTs)has become increasingly complex.In particular,seismic excitation can create a resonance response and cau... With the rapid development of large megawatt wind turbines,the operation environment of wind turbine towers(WTTs)has become increasingly complex.In particular,seismic excitation can create a resonance response and cause excessive vibration of the WTT.To investigate the vibration attenuation performance of the WTT under seismic excitations,a novel passive vibration control device,called a prestressed tuned mass damper(PS-TMD),is presented in this study.First,a mathematical model is established based on structural dynamics under seismic excitation.Then,the mathematical analytical expression of the dynamic coefficient is deduced,and the parameter design method is obtained by system tuning optimization.Next,based on a theoretical analysis and parameter design,the numerical results showed that the PS-TMD was able to effectively mitigate the resonance under the harmonic basal acceleration.Finally,the time-history analysis method is used to verify the effectiveness of the traditional pendulum tuned mass damper(PTMD)and the novel PS-TMD device,and the results indicate that the vibration attenuation performance of the PS-TMD is better than the PTMD.In addition,the PS-TMD avoids the nonlinear effect due to the large oscillation angle,and has the potential to dissipate hysteretic energy under seismic excitation. 展开更多
关键词 wind turbine tower prestressed tuned mass damper vibration control seismic excitation numerical simulation
下载PDF
Topology Optimization for Harmonic Excitation Structures with Minimum Length Scale Control Using the Discrete Variable Method
2
作者 Hongliang Liu Peijin Wang +2 位作者 Yuan Liang Kai Long Dixiong Yang 《Computer Modeling in Engineering & Sciences》 SCIE EI 2023年第6期1941-1964,共24页
Continuumtopology optimization considering the vibration response is of great value in the engineering structure design.The aimof this studyis toaddress the topological designoptimizationof harmonic excitationstructur... Continuumtopology optimization considering the vibration response is of great value in the engineering structure design.The aimof this studyis toaddress the topological designoptimizationof harmonic excitationstructureswith minimumlength scale control to facilitate structuralmanufacturing.Astructural topology design based on discrete variables is proposed to avoid localized vibration modes,gray regions and fuzzy boundaries in harmonic excitation topology optimization.The topological design model and sensitivity formulation are derived.The requirement of minimum size control is transformed into a geometric constraint using the discrete variables.Consequently,thin bars,small holes,and sharp corners,which are not conducive to the manufacturing process,can be eliminated from the design results.The present optimization design can efficiently achieve a 0–1 topology configuration with a significantly improved resonance frequency in a wide range of excitation frequencies.Additionally,the optimal solution for harmonic excitation topology optimization is not necessarily symmetric when the load and support are symmetric,which is a distinct difference fromthe static optimization design.Hence,one-half of the design domain cannot be selected according to the load and support symmetry.Numerical examples are presented to demonstrate the effectiveness of the discrete variable design for excitation frequency topology optimization,and to improve the design manufacturability. 展开更多
关键词 Discrete variable topology optimization harmonic excitation minimumlength scale control geometric constraint MANUFACTURABILITY
下载PDF
Nonlinear and Variable Structure Excitation Controller for Power System Stability 被引量:5
3
作者 王奔 Ronnie Belmans 《Journal of Southwest Jiaotong University(English Edition)》 2006年第4期339-347,共9页
A new nonlinear variable structure excitation controller is proposed. Its design combines the differential geometry theory and the variable structure controlling theory. The mathematical model in the form of "an affm... A new nonlinear variable structure excitation controller is proposed. Its design combines the differential geometry theory and the variable structure controlling theory. The mathematical model in the form of "an affme nonlinear system" is set up for the control of a large-scale power system. The static and dynamic performances of the nonlinear variable structure controller are simulated. The response of system with the controller proposed is compared to that of the nonlinear optimal controller when the system is subjected to a variety of disturbances. Simulation results show that the nonlinear variable structure excitation controller gives more satisfactorily static and dynamic performance and better robustness. 展开更多
关键词 excitation control Nonlinear control Variable structure control Dynamic performance Power system
下载PDF
Nonlinear variable structure excitation and steam valving controllers for power system stability
4
作者 Ben WANG Zongyuan MAO 《控制理论与应用(英文版)》 EI 2009年第1期97-102,共6页
A set of novel nonlinear variable structure excitation and steam-valving controllers are proposed in this paper. On the basis of the classical dynamic equations of a generator, excitation control and steam valving con... A set of novel nonlinear variable structure excitation and steam-valving controllers are proposed in this paper. On the basis of the classical dynamic equations of a generator, excitation control and steam valving control are simultaneously considered. Design of these controllers combines the differential geometry theory with the variable structure controlling theory. The mathematical model in the form of "an affine nonlinear system" is set up for the control design of a large-scale power plant. The dynamic performance of the nonlinear variable structure controllers proposed for a single machine connected to an infinite bus power system is simulated. Simulation results show that the nonlinear variable structure excitation and steam-valving controllers give satisfactory dynamic performance and good robustness. 展开更多
关键词 excitation control Nonlinear control Steam valving control Variable structure control
下载PDF
A Novel Coordinated Sliding Mode Controller Based on Lyapunov Method for SVC, Excitation and Steam Valving
5
作者 Jiwei Du Hu Peng Ben Wang 《Energy and Power Engineering》 2012年第6期523-528,共6页
A novel coordinated controller is proposed in the paper for SVC, excitation and steam valving for a single machine infinite system. Firstly, the nonlinear mathematic model of the system including the itation and steam... A novel coordinated controller is proposed in the paper for SVC, excitation and steam valving for a single machine infinite system. Firstly, the nonlinear mathematic model of the system including the itation and steam valving is exactly linearized via state feedback. Then, the quasi-linearized system after the exact lineariztion is controlled by the sliding model controller based on Lyapunov direct method. At last, the novel coordinated controller is compared with a traditional linear controller and a nonlinear optimal controller respectively by simulations. The simulation results show that the proposed controller gives better dynamic response and stronger robustness. 展开更多
关键词 SVC excitation and STEAM Alving SLIDING Mode control LYAPUNOV Simulation
下载PDF
Semi-active control of a cable-stayed bridge under multiple-support excitations 被引量:6
6
作者 代泽兵 黄金枝 王红霞 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2004年第3期68-76,共9页
This paper presents a semi-active strategy for seismic protection of a benchmark cable-stayed bridge with consideration of multiple-support excitations. In this control strategy, Magnetorheological (MR) dampers are pr... This paper presents a semi-active strategy for seismic protection of a benchmark cable-stayed bridge with consideration of multiple-support excitations. In this control strategy, Magnetorheological (MR) dampers are proposed as control devices, a LQG-clipped-optimal control algorithm is employed. An active control strategy, shown in previous researches to perform well at controlling the benchmark bridge when uniform earthquake motion was assumed, is also used in this study to control this benchmark bridge with consideration of multiple-support excitations. The performance of active control system is compared to that of the presented semi-active control strategy. Because the MR fluid damper is a con-trollable energy- dissipation device that cannot add mechanical energy to the structural system, the proposed control strategy is fail-safe in that bounded-input, bounded-output stability of the controlled structure is guaranteed. The numerical results demonstrated that the performance of the presented control design is nearly the same as that of the active control system; and that the MR dampers can effectively be used to control seismically excited cable-stayed bridges with multiple-support excitations. 展开更多
关键词 CABLE-STAYED bridge Multiple-support excitation MR damping SEMI-ACTIVE control
下载PDF
Active TLCGD control of plane asymmetric buildings under earthquake excitation 被引量:3
7
作者 Chuan Fu 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2011年第5期817-822,共6页
The sealed,tuned liquid column gas damper (TLCGD) with gas-spring effect extends the frequency range of application and efficiently increases the modal structural damping.Active tuned liquid column gas damper (ATL... The sealed,tuned liquid column gas damper (TLCGD) with gas-spring effect extends the frequency range of application and efficiently increases the modal structural damping.Active tuned liquid column gas damper (ATLCGD) is developed for the vibration control of plane asymmetric buildings subjected to earthquake excitation,improving the performance of the passive control scheme.The active behaviour is obtained by adjusting the pressure at the end of the liquid column using a pressurised reservoir.The classical linear quadratic regulator (LQR) design is presented as a straightforward approach to optimal control.Numerical simulations indicate a significant vibration reduction of plane asymmetric buildings by active control within the strong motion of the dynamic response. 展开更多
关键词 Asymmetric building Earthquake excitation Active control LQR algorithm
下载PDF
STOCHASTIC OPTIMAL CONTROL OF STRONGLY NONLINEAR SYSTEMS UNDER WIDE-BAND RANDOM EXCITATION WITH ACTUATOR SATURATION 被引量:3
8
作者 Changshui Feng Weiqiu Zhu 《Acta Mechanica Solida Sinica》 SCIE EI 2008年第2期116-126,共11页
A bounded optimal control strategy for strongly non-linear systems under non-white wide-band random excitation with actuator saturation is proposed. First, the stochastic averaging method is introduced for controlled ... A bounded optimal control strategy for strongly non-linear systems under non-white wide-band random excitation with actuator saturation is proposed. First, the stochastic averaging method is introduced for controlled strongly non-linear systems under wide-band random excitation using generalized harmonic functions. Then, the dynamical programming equation for the saturated control problem is formulated from the partially averaged Itō equation based on the dynamical programming principle. The optimal control consisting of the unbounded optimal control and the bounded bang-bang control is determined by solving the dynamical programming equation. Finally, the response of the optimally controlled system is predicted by solving the reduced Fokker-Planck-Kolmogorov (FPK) equation associated with the completed averaged Itō equation. An example is given to illustrate the proposed control strategy. Numerical results show that the proposed control strategy has high control effectiveness and efficiency and the chattering is reduced significantly comparing with the bang-bang control strategy. 展开更多
关键词 nonlinear system optimal control actuator saturation stochastic averaging Wide-band random excitation
下载PDF
Chaos and chaotic control in a relative rotation nonlinear dynamical system under parametric excitation 被引量:1
9
作者 时培明 韩东颖 刘彬 《Chinese Physics B》 SCIE EI CAS CSCD 2010年第9期112-117,共6页
This paper studies the chaotic behaviours of a relative rotation nonlinear dynamical system under parametric excitation and its control. The dynamical equation of relative rotation nonlinear dynamical system under par... This paper studies the chaotic behaviours of a relative rotation nonlinear dynamical system under parametric excitation and its control. The dynamical equation of relative rotation nonlinear dynamical system under parametric excitation is deduced by using the dissipation Lagrange equation. The. criterion of existence of chaos under parametric excitation is given by using the Melnikov theory. The chaotic behaviours are detected by numerical simulations including bifurcation diagrams, Poincare map and maximal Lyapunov exponent. Furthermore, it implements chaotic control using nomfeedback method. It obtains the parameter condition of chaotic control by the Melnikov theory. Numerical simulation results show the consistence with the theoretical analysis. The chaotic motions can be controlled to periodmotions by adding an excitation term. 展开更多
关键词 relative rotation nonlinear dynamical system parametric excitation chaotic control
下载PDF
Load Frequency Control of Small Hydropower Plants Using One-Input Fuzzy PI Controller with Linear and Non-Linear Plant Model 被引量:2
10
作者 Derek Ajesam Asoh Edwin Nyuysever Mbinkar Albert Nouck Moutlen 《Smart Grid and Renewable Energy》 2022年第1期1-16,共16页
<span style="font-family:Verdana;">This study presents an intelligent approach for load frequency control (LFC) of small hydropower plants (SHPs). The approach which is based on fuzzy logic (FL), takes... <span style="font-family:Verdana;">This study presents an intelligent approach for load frequency control (LFC) of small hydropower plants (SHPs). The approach which is based on fuzzy logic (FL), takes into account the non-linearity of SHPs—something which is not possible using traditional controllers. Most intelligent methods use two-</span><span style="font-family:;" "=""> </span><span style="font-family:;" "=""><span style="font-family:Verdana;">input fuzzy controllers, but because such controllers are expensive, there is </span><span style="font-family:Verdana;">economic interest in the relatively cheaper single-input controllers. A n</span><span style="font-family:Verdana;">on-</span></span><span style="font-family:;" "=""> </span><span style="font-family:Verdana;">linear control model based on one-input fuzzy logic PI (FLPI) controller was developed and applied to control the non-linear SHP. Using MATLAB/Si</span><span style="font-family:Verdana;">- </span><span style="font-family:Verdana;">mulink SimScape, the SHP was simulated with linear and non-linear plant models. The performance of the FLPI controller was investigated and compared with that of the conventional PI/PID controller. Results show that the settling time for the FLPI controller is about 8 times shorter;while the overshoot is about 15 times smaller compared to the conventional PI/PID controller. Therefore, the FLPI controller performs better than the conventional PI/PID controller not only in meeting the LFC control objective but also in ensuring increased dynamic stability of SHPs.</span> 展开更多
关键词 Small Hydropower Plant Linear and non-linear Model Load Frequency control non-linear control Fuzzy Logic controller Renewable Energy
下载PDF
Optimization of passive control performance for different hard disk drives subjected to shock excitation
11
作者 Seyed Rashid Alavi Mehdi Rahmati Saeed Ziaei-Rad 《Journal of Central South University》 SCIE EI CAS CSCD 2017年第4期891-899,共9页
Laptop personal computers(LPCs) and their components are vulnerable devices in harsh mechanical environments. One of the most sensitive components of LPCs is hard disk drive(HDD) which needs to be protected against da... Laptop personal computers(LPCs) and their components are vulnerable devices in harsh mechanical environments. One of the most sensitive components of LPCs is hard disk drive(HDD) which needs to be protected against damages attributable to shock and vibration in order to have better magnetic read/write performance. In the present work, a LPC and its HDD are modeled as two degrees of freedom system and the nonlinear optimization method is employed to perform a passive control through minimizing peak of HDD absolute acceleration caused by a base shock excitation. The presented shock excitation is considered as half-sine pulse of acceleration. In addition, eleven inequality constraints are defined based on geometrical limitations and allowable intervals of lumped modal parameters. The target of the optimization is to reach optimum modal parameters of rubber mounts and rubber feet as design variables and subsequently propose new characteristics of rubber mounts and rubber feet to be manufactured for the HDD protection against shock excitation. The genetic algorithm and the modified constrained steepest descent algorithm are employed in order to solve the nonlinear optimization problem for three widely-used commercial cases of HDD. Finally, the results of both optimization methods are compared to make sure about their accuracy. 展开更多
关键词 HARD DISK drive passive control shock excitation SEQUENTIAL QUADRATIC programming GENETIC algorithm rubber
下载PDF
An Active Control Study of the 1Cr18Ni9 Steel Plate Multipoint Excitation
12
作者 陆春月 寇子明 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2012年第4期721-724,共4页
A multipoint excitation experiment system of the 1Cr18Ni9 steel plate-pipe network as the main vibration body was established,which used transient flow produced by the wave exciter to excite the 1Cr18Ni9 steel plate-p... A multipoint excitation experiment system of the 1Cr18Ni9 steel plate-pipe network as the main vibration body was established,which used transient flow produced by the wave exciter to excite the 1Cr18Ni9 steel plate-pipe network to vibrate.The experimental results show that the 1Cr18Ni9 steel plate vibrates in three dimensions.The vibrations of the particles of the steel plate distributing along the pipe's axial have phase differences and take place near the cylinder side first.Therefore,it is a multipoint vibration mode.The amplitude of the 1Cr18Ni9 steel plate increases as the system pressure increases and decreases as the wave exciter's frequency decreases.The vibration intensity of the particles of the 1Cr18Ni9 steel plate close to the cylinder is the strongest and the amplitude is the highest in Y direction at a given system frequency.The vibration intensity of the particles close to the wave exciter is the strongest and the amplitude is the smallest in Z direction at a given system pressure. 展开更多
关键词 multipoint excitation steel plate active control transient flow pipe network
下载PDF
Study on Synchronous Generator Excitation Control Based on FLC
13
作者 Zhiting Guo Hong Song +1 位作者 Penggao Wen Zhizheng Fan 《World Journal of Engineering and Technology》 2015年第4期232-239,共8页
With the development of the national economy, the demand of electric power market has become higher than before. The stable and reliable power system is one of the important national economic securities. Reliability o... With the development of the national economy, the demand of electric power market has become higher than before. The stable and reliable power system is one of the important national economic securities. Reliability of generator excitation system is one of the important elements to determine the stability of the power system. Traditional PID cannot meet the requirements of the increasingly complex power system due to some defects. This essay introduces FLC control, combining with the traditional PID control. Using Matlab software, we analyze the curve and FLC is better than that by comparing with the traditional PID. 展开更多
关键词 Power System STABILITY excitation control TRADITIONAL PID control FLC
下载PDF
Harmonic excitation of linear respiratory mechanics for physiological dual controlled ventilation
14
作者 Francesco Montecchia 《Journal of Biomedical Science and Engineering》 2012年第11期678-695,共18页
The theoretical approach along with the rationale of harmonic excitation modality (HEM) applied as optimal dual controlled ventilation (DCV) to anaesthetized or severe brain injured patients, whose respiretory mechani... The theoretical approach along with the rationale of harmonic excitation modality (HEM) applied as optimal dual controlled ventilation (DCV) to anaesthetized or severe brain injured patients, whose respiretory mechanics can be properly assumed steady and linear, are presented and discussed. The design criteria of an improved version of the Advanced Lung Ventilation System (ALVS), including HEM in its functional features, are described in details. In particular, the elimination of any undesiderable artificial distortion affecting the respiratory and ventilation pattern waveforms is achieved by maintaining continuous forever the airflow inside the ventilation circuit, ensuring also the highest level of safety for patient in any condition. In such a way, the full-time compatibility of controlled breathings with spontaneous breathing activity of patient during continuous positive airways pressure (CPAP) or bilevel positive airways pressure (BiPAP) ventilation modalities and during assisted/controlled ventilation(A/CV), includeing also synchronized or triggered ventilation modalities, is an intrinsic innovative feature of the system available for clinical application. As expected and according to the clinical requirements, HEM provides for physiological respiratory and ventilation pattern waveforms together with optimal “breath to breath” feedback control of lung volume driven by an improved diagnostic measurement procedure, whose outputs are also vital for adapting all the preset ventilation parameters to the current value of the respiratory parameters of patient. The results produced by software simulations concerning both adult and neonatal patients in different clinical conditions are completely consistent with those obtained by the theoretical treatment, showing that HEM reaches the best performances from both clinical and engineering points of view. 展开更多
关键词 DUAL controlled Ventilation (DCV) Harmonic excitation MODALITY (HEM) RESPIRATORY Mechanics Pressure and AIRFLOW WAVEFORMS PHYSIOLOGICAL Pattern Lung Volume control
下载PDF
Analysis on the Fast Excitation System of Composite Magnetic Controllable Reactor
15
作者 Cuizhi WANG 《International English Education Research》 2014年第10期40-42,共3页
关键词 可控电抗器 励磁系统 磁性 复合 双向功能 响应速度
下载PDF
Experimental Investigation on Vibration Control of Rotor-bearing System with Active Magnetic Exciter 被引量:11
16
作者 WANG Weimin GAO Jinji +1 位作者 HUANG Liquan XIN Zhengqiu 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2011年第6期1013-1021,共9页
Vibration control is an efficient way to minimize a rotating machine’s vibration level so that its vibration fault-free can be realized.While,several factors,such as unbalance,misalignment and instability,contribute ... Vibration control is an efficient way to minimize a rotating machine’s vibration level so that its vibration fault-free can be realized.While,several factors,such as unbalance,misalignment and instability,contribute to the serious vibration of rotating machines.It is necessary that one apparatus can depress vibration caused by two or more reasons.The fault self-recovery(FSR) mechanism is introduced and investigated.Strategies of vibration control are investigated theoretically using numerical method firstly.Active magneticelectric exciter(AME) are selected as the actuator of a FSR device because it can provide suitable force by varying the control current in the exciters depending upon a proportional and derivative control law.By numerical study,it is indicate that only a small control force is needed to improve stability margins of the compressor and prevent subsynchronous vibration fault efficiently.About synchronous vibration,three control strategies,searching in whole circle,fast optimizing control(FOC),and none mistaking control,are investigated to show which of the control strategy can realize the fault self-recovery in the shortest time.Experimental study is conducted on a test rig with variable rotating speed.Results of the test indicate that the non-mistake control strategy can minimize synchronous vibration in less than three seconds.The proposed research can provide a new insight for subsynchronous and synchronous vibration restraining about centrifugal compressor. 展开更多
关键词 vibration control rotor-bearing system active magnetic exciter subsynchronous
下载PDF
CONTROLLING EROSION OF SAFE BASIN IN NONLINEAR PARAMETRICALLY EXCITED SYSTEMS 被引量:6
17
作者 徐鉴 陆启韶 黄克累 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 1996年第3期281-288,共8页
This paper considers the dynamical behavior of a Duffing-Mathieu type system with a cubic single-well potential during the principal parametric resonance. Both the cases of constant and time-dependent excitation ampli... This paper considers the dynamical behavior of a Duffing-Mathieu type system with a cubic single-well potential during the principal parametric resonance. Both the cases of constant and time-dependent excitation amplitude are used to observe the variation of the extent and the rate of the erosion in safe basins. It is evident that the appearance of fractal basin boundaries heralds the onset of the losing of structural integrity. The minimum value of control parameter to prevent the basin from erosion is given along with the excitation amplitude varying. The results show the time-dependence of excitation amplitude can be used to control the extent and the rate of the erosion and delay the first occurrence of heteroclinic tangency. 展开更多
关键词 excited system safe-basin erosion nonlinear dynamics control FRACTAL
下载PDF
Separate Control of High Frequency Electro-hydraulic Vibration Exciter 被引量:7
18
作者 JIA Wen'ang RUAN Jian REN Yan 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2011年第2期293-302,共10页
The working frequency of the conventional electro-hydraulic vibration exciters,which consist of a servo valve and a hydraulic cylinder,is generally restricted within a narrow range due to limited frequency response ca... The working frequency of the conventional electro-hydraulic vibration exciters,which consist of a servo valve and a hydraulic cylinder,is generally restricted within a narrow range due to limited frequency response capability of the servo valve itself.To counteract such restriction,a novel scheme for an electro-hydraulic vibrator,controlled by a two-dimensional valve(2D valve) and a bias valve in parallel,is therefore proposed.The frequency,amplitude and offset are independently controlled by rotary speed,axial sliding of the spool of the 2D valve and axial sliding of the spool of the bias valve.The principle of separate control was presented and the regulation approach of frequency,amplitude and offset was discussed.A mathematical model of the hydraulic power mechanism for the proposed vibration exciter was established to investigate the relationship between the amplitude and the axial sliding of the 2D valve' spool,as well as that between the offset and the axial sliding of the bias valve's spool at various frequencies.An experimental system was built to validate the theoretical analysis.It is verified that the 2D exciter is capable of working smoothly in a frequency range of 5- 200 Hz.And its frequency,amplitude and offset can be controlled respectively by either closed loop or open loop method.There is a linear relationship between the output amplitude and the spool axial opening of the 2D valve until a point when the flow rate becomes saturate and the amplitude remains constant.The offset displacement of the cylinder's piston is linearly proportional to the axial displacement of the spool of the bias valve,when the valve opening is less than 25%.Thereafter,the slop of the offset curve decreases and tends to saturate.The proposed electro-hydraulic vibration controlled by the 2D valve not only facilitates the realization of high-frequency electro-hydraulic vibration,the high-accuracy of vibration can also be achieved by means of independent controls to the frequency,amplitude and offset. 展开更多
关键词 control valves electro-hydraulic system vibration exciter dynamics characteristics
下载PDF
Optimal control strategies for stochastically excited quasi partially integrable Hamiltonian systems 被引量:2
19
作者 Ronghua Huan Maolin Deng Weiqiu Zhu 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2007年第3期311-319,共9页
In this paper two different control strategies designed to alleviate the response of quasi partially integrable Hamiltonian systems subjected to stochastic excitation are proposed. First, by using the stochastic avera... In this paper two different control strategies designed to alleviate the response of quasi partially integrable Hamiltonian systems subjected to stochastic excitation are proposed. First, by using the stochastic averaging method for quasi partially integrable Hamiltonian systems, an n-DOF controlled quasi partially integrable Hamiltonian system with stochastic excitation is converted into a set of partially averaged It^↑o stochastic differential equations. Then, the dynamical programming equation associated with the partially averaged It^↑o equations is formulated by applying the stochastic dynamical programming principle. In the first control strategy, the optimal control law is derived from the dynamical programming equation and the control constraints without solving the dynamical programming equation. In the second control strategy, the optimal control law is obtained by solving the dynamical programming equation. Finally, both the responses of controlled and uncontrolled systems are predicted through solving the Fokker-Plank-Kolmogorov equation associated with fully averaged It^↑o equations. An example is worked out to illustrate the application and effectiveness of the two proposed control strategies. 展开更多
关键词 Nonlinear system Stochastic excitation Stochastic averaging Optimal control Dynamical programming
下载PDF
Research on DSP-Based Automatic Excitation Regulator in Small Rural Hydropower Station 被引量:1
20
作者 Gu Xiang-yu Zhao Yu-lin +2 位作者 Fu Yan Zhang Yu-juan Sun Shuai 《Journal of Northeast Agricultural University(English Edition)》 CAS 2013年第1期65-69,共5页
Excitation regulator has played an important role to ensure that generator run safely and stably. However, in some remote areas, the rural small generator excitation control system is very backward, and it has hindere... Excitation regulator has played an important role to ensure that generator run safely and stably. However, in some remote areas, the rural small generator excitation control system is very backward, and it has hindered the development of Chinese agriculture and the pace of new countryside construction. This paper introduced a kind of structure and basic principle of DSP-based automatic excitation regulator, which was applied to rural small generator. We chose TMS320LF2407A chip as the core of regulator control system; the regulator adjusted PWM based on PID control strategy to control the exciting current. The theoretical analysis showed that the regulator had the characteristics of simplicity and reliability, well dynamic and static characteristics, and it could also adjust its own state quickly. The result was applicable to small rural hydropower station. 展开更多
关键词 DSP PID control strategy automatic excitation regulator new countryside construction
下载PDF
上一页 1 2 119 下一页 到第
使用帮助 返回顶部