期刊文献+
共找到8,198篇文章
< 1 2 250 >
每页显示 20 50 100
A Two-Layer Active Power Optimization and Coordinated Control for Regional Power Grid Partitioning to Promote Distributed Renewable Energy Consumption
1
作者 Wentao Li Jiantao Liu +3 位作者 Yudun Li GuoxinMing Kaifeng Zhang Kun Yuan 《Energy Engineering》 EI 2024年第9期2479-2503,共25页
With the large-scale development and utilization of renewable energy,industrial flexible loads,as a kind of loadside resource with strong regulation ability,provide new opportunities for the research on renewable ener... With the large-scale development and utilization of renewable energy,industrial flexible loads,as a kind of loadside resource with strong regulation ability,provide new opportunities for the research on renewable energy consumption problem in power systems.This paper proposes a two-layer active power optimization model based on industrial flexible loads for power grid partitioning,aiming at improving the line over-limit problem caused by renewable energy consumption in power grids with high proportion of renewable energy,and achieving the safe,stable and economical operation of power grids.Firstly,according to the evaluation index of renewable energy consumption characteristics of line active power,the power grid is divided into several partitions,and the interzone tie lines are taken as the optimization objects.Then,on the basis of partitioning,a two-layer active power optimization model considering the power constraints of industrial flexible loads is established.The upper-layer model optimizes the planned power of the inter-zone tie lines under the constraint of the minimum peak-valley difference within a day;the lower-layer model optimizes the regional source-load dispatching plan of each resource in each partition under the constraint of theminimumoperation cost of the partition,so as to reduce the line overlimit phenomenon caused by renewable energy consumption and save the electricity cost of industrial flexible loads.Finally,through simulation experiments,it is verified that the proposed model can effectively mobilize industrial flexible loads to participate in power grid operation and improve the economic stability of power grid. 展开更多
关键词 Renewable energy consumption active power optimization power grid partitioning industrial flexible loads line over-limit
下载PDF
Media Sporting Events as Platforms for‘Soft Power’and Digital Activism
2
作者 Ivana Matteucci 《Sociology Study》 2024年第1期1-8,共8页
Mediatic sporting events are increasingly used in the geopolitical arena to gain consensus, at the same time emerging as platforms for the discussion of social issues, such as human rights and sustainability. This art... Mediatic sporting events are increasingly used in the geopolitical arena to gain consensus, at the same time emerging as platforms for the discussion of social issues, such as human rights and sustainability. This article presents an investigation into the role of mediatic sporting events and digital platforms in sparking political debate and social engagement to bring about change, including discussions on global and local interests and the performances of activist fans to promote debate on specific issues. The investigation employs a quantitative methodology. The initial inductive analysis uses a matrix of cultural key-frames of the empowerment and protest that accompany media sporting events, verifying their presence and effectiveness in different communication milieus. An analysis of the representation of protests on social media was performed through content analysis. The results of the investigation show that mediatic sporting events are to be understood as a diverse range of generators of multiple political effects: from the exercise of power to mass mobilization and media criticism. 展开更多
关键词 sporting events mainstream media social media soft power digital activism
下载PDF
Wind farm active power dispatching algorithm based on Grey Incidence 被引量:2
3
作者 Binbin Zhang Mengxin Jia +2 位作者 Chaobo Chen Kun Wang Jichao Li 《Global Energy Interconnection》 EI CAS CSCD 2023年第2期175-183,共9页
This study proposes a wind farm active power dispatching(WFAPD) algorithm based on the grey incidence method, which does not rely on an accurate mathematical model of wind turbines. Based on the wind turbine start-sto... This study proposes a wind farm active power dispatching(WFAPD) algorithm based on the grey incidence method, which does not rely on an accurate mathematical model of wind turbines. Based on the wind turbine start-stop data at different wind speeds, the weighting coefficients, which are the participation degrees of a variable speed system and a variable pitch system in power regulation, are obtained using the grey incidence method. The incidence coefficient curve is fitted by the B-spline function at a full range of wind speeds, and the power regulation capacity of all wind turbines is obtained. Finally, the WFAPD algorithm, which is based on the regulating capacity of each wind turbine, is compared with the wind speed weighting power dispatching(WSWPD) algorithm in MATLAB. The simulation results show that the active power fluctuation of the wind farm is smaller, the rotating speed of wind turbines is smoother, and the fatigue load of highspeed turbines is effectively reduced. 展开更多
关键词 Wind farm active power dispatching Grey incidence B-spline function
下载PDF
DC active power filter based on model predictive control for DC bus overvoltage suppression of accelerator grid power supply 被引量:1
4
作者 张鸿淇 朱帮友 +3 位作者 马少翔 李志恒 张明 潘垣 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第6期1-13,共13页
The China Fusion Engineering Test Reactor plans to build a 200 k V/25 A acceleration grid power supply(AGPS)for the negative-ion-based neutral beam injector prototype system.The AGPS uses a rectifier-inverter-isolated... The China Fusion Engineering Test Reactor plans to build a 200 k V/25 A acceleration grid power supply(AGPS)for the negative-ion-based neutral beam injector prototype system.The AGPS uses a rectifier-inverter-isolated step-up structure.There is a DC bus between the rectifier and the inverter.In order to limit DC bus voltage ripple and transient fluctuations,a large number of capacitors are used,which degrades the reliability of the power supply and occupies a large amount of space.This work finds that due to the difference in the turn-off time of the rectifier and the inverter,the capacitance mainly depends on the rectifier current when the inverter is turned off.On this basis,an active power filter(APF)scheme is proposed to absorb the current.To enhance the dynamic response ability of the APF,model predictive control is adopted.In this paper,the circuit structure of the APF is introduced,the prediction model is deduced,the corresponding control strategy and signal detection method are proposed,and the simulation and experimental results show that APF can track the transient current of the DC bus and reduce the voltage fluctuation significantly. 展开更多
关键词 CFETR NBI accelerator grid power supply power active filter model predictive control
下载PDF
Two-Dimensional Images of Current and Active Power Signals for Elevator Condition Recognition
5
作者 Xunsheng Ji Dazhi Wang Kun Jiang 《Journal of Harbin Institute of Technology(New Series)》 CAS 2023年第2期48-60,共13页
In this paper, an improved two-dimensional convolution neural network(2DCNN) is proposed to monitor and analyze elevator health, based on the distribution characteristics of elevator time series data in two-dimensiona... In this paper, an improved two-dimensional convolution neural network(2DCNN) is proposed to monitor and analyze elevator health, based on the distribution characteristics of elevator time series data in two-dimensional images. The current and effective power signals from an elevator traction machine are collected to generate gray-scale binary images. The improved two-dimensional convolution neural network is used to extract deep features from the images for classification, so as to recognize the elevator working conditions. Furthermore, the oscillation criterion is proposed to describe and analyze the active power oscillations. The current and active power are used to synchronously describe the working condition of the elevator, which can explain the co-occurrence state and potential relationship of elevator data. Based on the improved integration of local features of the time series, the recognition accuracy of the proposed 2DCNN is 97.78%, which is better than that of a one-dimensional convolution neural network. This research can improve the real-time monitoring and visual analysis performance of the elevator maintenance personnel, as well as improve their work efficiency. 展开更多
关键词 elevator condition CURRENT active power two-dimensional convolution network(2DCNN)
下载PDF
Blockchain-Based Power Transaction Method for Active Distribution Network
6
作者 Fei Zeng Zhinong Wei +1 位作者 Haiteng Han Yang Chen 《Energy Engineering》 EI 2023年第5期1067-1080,共14页
A blockchain-based power transaction method is proposed for Active Distribution Network(ADN),considering the poor security and high cost of a centralized power trading system.Firstly,the decentralized blockchain struc... A blockchain-based power transaction method is proposed for Active Distribution Network(ADN),considering the poor security and high cost of a centralized power trading system.Firstly,the decentralized blockchain structure of the ADN power transaction is built and the transaction information is kept in blocks.Secondly,considering the transaction needs between users and power suppliers in ADN,an energy request mechanism is proposed,and the optimization objective function is designed by integrating cost aware requests and storage aware requests.Finally,the particle swarm optimization algorithm is used for multi-objective optimal search to find the power trading scheme with the minimum power purchase cost of users and the maximum power sold by power suppliers.The experimental demonstration of the proposed method based on the experimental platform shows that when the number of participants is no more than 10,the transaction delay time is 0.2 s,and the transaction cost fluctuates at 200,000 yuan,which is better than other comparison methods. 展开更多
关键词 Blockchain active distribution network power transaction energy request mechanism particle swarm optimization algorithm
下载PDF
Activation Distance and Capacity Analysis for Ambient Backscatter Communications with Sensitivity Constraint and Beamforming
7
作者 Mu Yunping Fan Dian +2 位作者 Wang Gongpu Xu Yongjun Kuang Lei 《China Communications》 SCIE CSCD 2024年第11期257-266,共10页
Circuit sensitivity of sensors or tags without battery is one practical constraint for ambient backscatter communication systems.This letter considers using beamforming to reduce the sensitivity constraint and evaluat... Circuit sensitivity of sensors or tags without battery is one practical constraint for ambient backscatter communication systems.This letter considers using beamforming to reduce the sensitivity constraint and evaluates the corresponding performance in terms of the tag activation distance and the system capacity.Specifically,we derive the activation probabilities of the tag in the case of single-antenna and multi-antenna transmitters.Besides,we obtain the capacity expressions for the ambient backscatter communication system with beamforming and illustrate the power allocation that maximizes the system capacity when the tag is activated.Finally,simulation results are provided to corroborate our proposed studies. 展开更多
关键词 activation distance ambient backscatter communications beamforming channel capacity power allocation sensitivity
下载PDF
Sum-Rate Maximization in Active RIS-Assisted Multi-Antenna WPCN
8
作者 Jiang Jie Lyu Bin +1 位作者 Chen Pengcheng Yang Zhen 《China Communications》 SCIE CSCD 2024年第6期23-39,共17页
In this paper,we propose an active reconfigurable intelligent surface(RIS)enabled hybrid relaying scheme for a multi-antenna wireless powered communication network(WPCN),where the active RIS is employed to assist both... In this paper,we propose an active reconfigurable intelligent surface(RIS)enabled hybrid relaying scheme for a multi-antenna wireless powered communication network(WPCN),where the active RIS is employed to assist both wireless energy transfer(WET)from the power station(PS)to energyconstrained users and wireless information transmission(WIT)from users to the receiving station(RS).For further performance enhancement,we propose to employ both transmit beamforming at the PS and receive beamforming at the RS.We formulate a sumrate maximization problem by jointly optimizing the RIS phase shifts and amplitude reflection coefficients for both the WET and the WIT,transmit and receive beamforming vectors,and network resource allocation.To solve this non-convex problem,we propose an efficient alternating optimization algorithm with the linear minimum mean squared error criterion,semidefinite relaxation(SDR)and successive convex approximation techniques.Specifically,the tightness of applying the SDR is proved.Simulation results demonstrate that our proposed scheme with 10 reflecting elements(REs)and 4 antennas can achieve 17.78%and 415.48%performance gains compared to the single-antenna scheme with 10 REs and passive RIS scheme with 100 REs,respectively. 展开更多
关键词 active reconfigurable intelligent surface BEAMFORMING sum-rate maximization wireless powered communication network
下载PDF
Capacitorless Solid-state Power Filter for Single-phase DC-AC Converters
9
作者 Haitham Kanakri Euzeli C.Dos Santos 《CES Transactions on Electrical Machines and Systems》 EI CSCD 2024年第3期367-377,共11页
Converters rely on passive filtering as a crucial element due to the high-frequency operational characteristics of power electronics.Traditional filtering methods involve a dual inductor-capacitor(LC)cell or an induct... Converters rely on passive filtering as a crucial element due to the high-frequency operational characteristics of power electronics.Traditional filtering methods involve a dual inductor-capacitor(LC)cell or an inductor-capacitor-inductor(LCL)T-circuit.However,capacitors are susceptible to wear-out mechanisms and failure modes.Nevertheless,the necessity for monitoring and regular replacement adds to an elevated cost of ownership for such systems.The utilization of an active output power filter can be used to diminish the dimensions of the LC filter and the electrolytic dc-link capacitor,even though the inclusion of capacitors remains an indispensable part of the system.This paper introduces capacitorless solid-state power filter(SSPF)for single-phase dc-ac converters.The proposed configuration is capable of generating a sinusoidal ac voltage without relying on capacitors.The proposed filter,composed of a planar transformer and an H-bridge converter operating at high frequency,injects voltage harmonics to attain a sinusoidal output voltage.The design parameters of the planar transformer are incorporated,and the impact of magnetizing and leakage inductances on the operation of the SSPF is illustrated.Theoretical analysis,supported by simulation and experimental results,are provided for a design example for a single-phase system.The total harmonic distortion observed in the output voltage is well below the IEEE 519 standard.The system operation is experimentally tested under both steady-state and dynamic conditions.A comparison with existing technology is presented,demonstrating that the proposed topology reduces the passive components used for filtering. 展开更多
关键词 Solid-state power filter(SSPF) Capacitorless topology active output power filter(AOF) Planar transformer Electrolytic capacitor LIFETIME Wear-out mechanisms
下载PDF
Chemical Analysis of Activated Carbon from Bull and Cow Horns Pyrolysis to Be Used as Antidotes
10
作者 Alexandre Ngama Mwabi Pierre Yoniene Yassa Vestine Ntakarutimana 《Open Journal of Applied Sciences》 2024年第8期2133-2143,共11页
The purpose of this study is to compare the results of chemical analysis of two types of activated from the pyrolysis of bull horn and that of cow. Six samples were used to measure pH, carbon, calcium and to determine... The purpose of this study is to compare the results of chemical analysis of two types of activated from the pyrolysis of bull horn and that of cow. Six samples were used to measure pH, carbon, calcium and to determine adsorbent power. The pH was measured at a temperature of 20˚C using an “ANION 7010 ionomer” pH meter, the carbon (C) content was analyzed using a “EURO EA 3000” analyzer. and the electronic balance: “Sartorius CP-2P”, calcium (Ca) was analyzed using a DFS-8 spectrograph. For the adsorbency test, the 0.15% methylene blue R solution was used. At the end of this study, we found that the activated carbon from the bull horn demonstrated a carbon content that is higher than that of the cow horn (20.79% against 15.63%), activated carbon of cow horn is richer in calcium than that of bull horn (16.27% against 3.69%) and then the pH. The cow horn is higher than that of the bull horn (7.43 versus 6.5). For the adsorbent power, the sample (75% bull horn and 25% cow horn) was recorded with the greatest adsorbent power. Thus, from this study, it can be recommended as an activated carbon antidote to be used for poisonings treatment. 展开更多
关键词 activated Carbon Bull Horn Cow Horn Oil Palm Nut Shells Absorbent power
下载PDF
Antiradical Activity and Ferric Reducing Antioxidant Power of <i>Pleurotus pulmonarius</i>, <i>Pleurotus floridanus</i>and <i>Pleurotus sajor</i>-<i>caju</i>Formulations Extracts <i>in Vitro</i>
11
作者 Etoundi O.C.Blanche Kayo T.C.Valère +1 位作者 Mbang M.A.Judith Ngono N.A.Rosalie 《Food and Nutrition Sciences》 2019年第10期1202-1211,共10页
Edible mushrooms, known for many years and considered as functional foods, contain a wide variety of biomolecules with nutritional and medicinal properties. Pleurotus species, especially Pleurotus pulmonarius, Pleurot... Edible mushrooms, known for many years and considered as functional foods, contain a wide variety of biomolecules with nutritional and medicinal properties. Pleurotus species, especially Pleurotus pulmonarius, Pleurotus floridanus and Pleurotus sajor-caju are the most commonly consumed in Cameroon. The present work aims to study the “in vitro” antiradical activity and ferric reducing antioxidant power of extracts of formulations of these three species. Mushrooms were harvested in two mycicultures from Cameroon, then dried and crushed finely to obtain powders. In well-defined proportions, ten different formulations were made and their aqueous, ethanol and hydroethanol extracts prepared. These were used to determine total phenolic content by using Folin-Ciocalteu reagent method, the antioxidant activity determined by 2,2-diphenyl-1-picrylhydrazyl radical (DPPH) scavenging activity and ferric-reducing antioxidant power (FRAP) assays, with vitamin C (ascorbic acid) as standard. The results obtained from the ten formulations, including thirty extracts, showed that all the extracts had quite significant ferric reducing power at C = 1 mg/ml, (7.35 - 26.02 mg EAA/g). They also had good percentages of DPPH radical inhibition at C = 25 mg/ml (60.40% - 77.72%) and a significant polyphenol content at C = 100 mg/ml (13.73 - 21.15 mg CE/g). The aqueous extracts had the best activities compared to the standard. In addition, a strong positive linear correlation exists between polyphenol content and the scavenging property (R2 = 0.9063;p = 0.0003) also with the ferric reducing test (R2 = 0.9253;p = 0.0001);suggesting the responsibility of these compounds for these activities. This study suggests that these mushrooms may be used as a natural source of potential antioxidants for food supplements and their consumption is strongly recommended for their beneficial effects on health through, the protection of the human body against the oxidative damage involved in the occurrence of many chronic diseases. 展开更多
关键词 Scavenging activity Ferric REDUCING ANTIOXIDANT power Edible Mushrooms
下载PDF
基于Power BI的核电大修工单成本分析工具开发与应用
12
作者 苏向南 邹玮 周辉 《中国核电》 2024年第3期315-320,共6页
介绍了基于Power BI搭建大修工单成本分析数据模型的开发过程以及应用情况。通过与工单系统的动态关联,准确统计出大修某个工单、某个系统、某个子项、某个区域或是某次大修的成本。基于对大修成本数据的精细分析,从单纯的财务指标计划... 介绍了基于Power BI搭建大修工单成本分析数据模型的开发过程以及应用情况。通过与工单系统的动态关联,准确统计出大修某个工单、某个系统、某个子项、某个区域或是某次大修的成本。基于对大修成本数据的精细分析,从单纯的财务指标计划驱动完成了向业务精益驱动的过程管控转变,持续挖掘大修成本的精益空间,单次大修直接经济效益均超过1000万元,累计效益达7648万元,同时提升成本管理的事前决策支持与业务指导能力,促进大修业务管理水平的持续提升。 展开更多
关键词 核电 大修成本 作业成本 维度建模 工单成本 价值维修
下载PDF
PARAMETER OPTIMIZATION OF ELECTRIC POWER STEERING INTEGRATED WITH ACTIVE FRONT STEERING FUNCTION 被引量:1
13
作者 王春燕 赵万忠 +1 位作者 刘顺 孙培坤 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2012年第1期96-102,共7页
The dynanaic model of a novel electric power steering(EPS) system integrated with active front steer- ing function and the three-freedom steering model are built. Based on these models, the concepts and the quanti- ... The dynanaic model of a novel electric power steering(EPS) system integrated with active front steer- ing function and the three-freedom steering model are built. Based on these models, the concepts and the quanti- tative expressions of road feel, sensitivity, and operation stability of the steering are introduced. Then, according to constrained optimization features of multi-variable function, a genetic algorithm is designed. Making the road feel of the steering as optimization objective, and operation stability and sensitivity of the steering as constraints, the system parameters are optimized by the genetic and the coordinate rotation algorithms. Simulation results show that the optimization of the novel EPS system by the genetic algorithm can effectively improve the road feel, thus providing a theoretical basis for the design and optimization of the novel EPS system. 展开更多
关键词 vehicle engineering electric power steering active front steering road feel genetic algorithm
下载PDF
COMPARISON AND EVALUATION OF CURRENT REFERENCE GENERATION STRATEGIES FOR ACTIVE POWER FILTERS IN THREE-PHASE FOUR-WIRE SYSTEMS
14
作者 陈东华 郭涛 +1 位作者 谢少军 周波 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2005年第4期298-306,共9页
For three phase four-wire active power filters (APFs), several typical power theories and corresponding current reference generation strategies are induced, p-q, d-q, unify power factor (UPF) and instantaneous act... For three phase four-wire active power filters (APFs), several typical power theories and corresponding current reference generation strategies are induced, p-q, d-q, unify power factor (UPF) and instantaneous active current (IAC) methods are analyzed and compared with each other. The interpretation of active and reactive currents in non-sinusoidal and unbalanced three-phase four-wire systems is given based on the generalized instantaneous reactive power theory. The performance and the characteristic are evaluated, and the application conditions of current reference generation strategies are concluded. Simulation results under different source voltages and loads verify the evaluation result. 展开更多
关键词 active power filters instantaneous reactive power current reference three-phase four wire power
下载PDF
Design and analysis of dual-mode structure repetitive control based hybrid current regulation scheme for active power filters
15
作者 邹志翔 王政 程明 《Journal of Southeast University(English Edition)》 EI CAS 2013年第4期407-413,共7页
An all-digital hybrid current regulation scheme for the single-phase shunt active power filter (APF) is presented. The proposed hybrid current control scheme integrates the deadbeat control and the dual-mode structu... An all-digital hybrid current regulation scheme for the single-phase shunt active power filter (APF) is presented. The proposed hybrid current control scheme integrates the deadbeat control and the dual-mode structure repetitive control (DMRC) so that it can offer superior steady-state performance and good transient features. Unlike the conventional schemes, the proposed scheme-based APF can compensate both the odd and the even order harmonics in grid. The detailed design criteria and the stability analysis of the proposed hybrid current controller are presented. Moreover, an improved structure which incorporates the proposed hybrid controller and the resonant controller for tracking specific order harmonics is given. The relationships between the resonant controller and different repetitive control schemes are discussed. Experimental results verify the effectiveness and advantages of the proposed hybrid control scheme. 展开更多
关键词 active power filter dual-mode structure repetitive control (DMRC) current control harmonic compensation resonant controller
下载PDF
Spiral Steel Wire Based Fiber-Shaped Stretchable and Tailorable Triboelectric Nanogenerator for Wearable Power Source and Active Gesture Sensor 被引量:18
16
作者 Lingjie Xie Xiaoping Chen +6 位作者 Zhen Wen Yanqin Yang Jihong Shi Chen Chen Mingfa Peng Yina Liu Xuhui Sun 《Nano-Micro Letters》 SCIE EI CAS CSCD 2019年第3期36-45,共10页
Continuous deforming always leads to the performance degradation of a flexible triboelectric nanogenerator due to the Young’s modulus mismatch of different functional layers.In this work,we fabricated a fiber-shaped ... Continuous deforming always leads to the performance degradation of a flexible triboelectric nanogenerator due to the Young’s modulus mismatch of different functional layers.In this work,we fabricated a fiber-shaped stretchable and tailorable triboelectric nanogenerator(FST-TENG)based on the geometric construction of a steel wire as electrode and ingenious selection of silicone rubber as triboelectric layer.Owing to the great robustness and continuous conductivity,the FST-TENGs demonstrate high stability,stretchability,and even tailorability.For a single device with ~6 cm in length and ~3 mm in diameter,the open-circuit voltage of ~59.7 V,transferred charge of ~23.7 nC,short-circuit current of ~2.67 μA and average power of ~2.13 μW can be obtained at 2.5 Hz.By knitting several FST-TENGs to be a fabric or a bracelet,it enables to harvest human motion energy and then to drive a wearable electronic device.Finally,it can also be woven on dorsum of glove to monitor the movements of gesture,which can recognize every single finger,different bending angle,and numbers of bent finger by analyzing voltage signals. 展开更多
关键词 Triboelectric NANOGENERATOR STRETCHABLE Human motion energy WEARABLE power source activE GESTURE SENSOR
下载PDF
PASSIVE-ACTIVE CONTROL OF POWER FLOW IN AN ISOLATION SYSTEM MOUNTED ON FLEXIBLE FOUNDATIONS 被引量:2
17
作者 Huo Rui Shi Yin Institute of Naval Ship Equipment Noise & Vibration, Naval University of Engineering Song Kongjie Shandong University of Technology 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2001年第2期111-115,共5页
A general model of flexible isolation systems which involves both the passive and active control factors is established by inserting actuators into an passive isolation system. And the power flow transmission function... A general model of flexible isolation systems which involves both the passive and active control factors is established by inserting actuators into an passive isolation system. And the power flow transmission function in such a system as with multi disturbance, multi mounts, passive isolators and actuators is deduced. By means of the numerical simulation method, the influence of actuators on power flow transmission characteristic is studied. And as a conclusion, the passive active synthetic control strategy of power flow is summarized. 展开更多
关键词 Vibration isolation power flow COUPLING active control
下载PDF
H∞ control of novel active steering integrated with electric power steering function 被引量:8
18
作者 ZHAO Wan-zhong LI Yi-jun +2 位作者 WANG Chun-yan ZHAO Ting GU Xiao-yue 《Journal of Central South University》 SCIE EI CAS 2013年第8期2151-2157,共7页
Based on the traditional active steering system, a novel active steering system integrated with electric power steering function was introduced, which can achieve the functions of both active steering and electric pow... Based on the traditional active steering system, a novel active steering system integrated with electric power steering function was introduced, which can achieve the functions of both active steering and electric power steering. In view of the interference from road random signal and sensor noise in the novel active steering system, the H∞ control model of the novel active steering system was built. With satisfying steering feel, good robust performance and steering stability being the control objectives, the H∞ controller for the novel active front steering (AFS) system was designed. The simulation results show that the novel AFS system with H∞ control strategy can attenuate the road interference quickly, and there is no resonance peak in the bode diagram. It can make the driver obtain more useful information in the low frequency range, and attenuate the road interference better in the high frequency range, thus the driver can get more satisfying road feeling. Therefore, the designed H∞ controller can synthesize the advantages of both robust performance and robust stability, and has certain contribution to the design of novel AFS system. 展开更多
关键词 vehicle engineering active steering electric power steering H∞ control
下载PDF
A PV powered shunt active power filter for power quality improvement 被引量:3
19
作者 Ayoub Benzahia Rabhi Boualaga +3 位作者 Ammar Moussi Laeid Zellouma Memich Meriem Bouziane Chaima 《Global Energy Interconnection》 2019年第2期143-149,共7页
This paper deals with power quality improvement using a three-phase active power filter(APF) connected to a PV power system. A direct power control(DPC) approach is proposed to eliminate harmonic current caused by any... This paper deals with power quality improvement using a three-phase active power filter(APF) connected to a PV power system. A direct power control(DPC) approach is proposed to eliminate harmonic current caused by any nonlinear loads and at the same time guarantees the delivery of a part of the load request from the same PV source. A boost converter is used for maximum power point(MPP) tracking purposes under various climate conditions through a fuzzy logic technique. The suggested study is tested under a MATLAB/Simulink environment. The obtained results depict the efficacy of the proposed procedures to meet the IEEE 519-1992 standard recommendation on harmonic levels. 展开更多
关键词 active power Filter(APF) PHOTOVOLTAIC (PV) Direct power Control (DPC) MAXIMUM power Point Tracking (MPPT)
下载PDF
Open-circuit fault diagnosis and fault tolerance for shunt active power filter 被引量:2
20
作者 PENG Tao ZHAO Shuai +1 位作者 DAN Han-bing YU Hua-xiong 《Journal of Central South University》 SCIE EI CAS CSCD 2017年第11期2582-2595,共14页
The open-circuit fault of the power switches in shunt active power filter(SAPF) would exacerbate the harmonic pollution of power grid, and degrade the reliability of the devices and system. A fault diagnosis method is... The open-circuit fault of the power switches in shunt active power filter(SAPF) would exacerbate the harmonic pollution of power grid, and degrade the reliability of the devices and system. A fault diagnosis method is proposed based on reference model and an over-modulation strategy under hardware fault tolerance for SAPF. First, a mathematic model is established for SAPF. Second, the residuals are generated by comparing the outputs of reference model and those of actual model, and open-switch fault is detected and diagnosed by residual evaluation. After that, hardware fault tolerance is performed with the three-phase four-switch(TPFS) topology to isolate the faulty phase. Finally, the over-modulation strategy is proposed to increase the voltage transfer ratio of the TPFS topology. Simulation and experimental results verified the feasibility and effectiveness of the proposed method. 展开更多
关键词 FAULT diagnosis FAULT TOLERANT reference model over-modulation THREE-PHASE four-switch TOPOLOGY SHUNT active power filter
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部