A multitracer-gas method was proposed to study the secondary air(SA)mixing along the bed height in a circulating fluidized bed(CFB)using carbon monoxide(CO),oxygen(O_(2)),and carbon dioxide(CO_(2))as tracer gases.Expe...A multitracer-gas method was proposed to study the secondary air(SA)mixing along the bed height in a circulating fluidized bed(CFB)using carbon monoxide(CO),oxygen(O_(2)),and carbon dioxide(CO_(2))as tracer gases.Experiments were carried out on a cold CFB test rig with a cross-section of 0.42 m×0.73 m and a height of 5.50 m.The effects of superficial velocity,SA ratio,bed inventory,and particle diameter on the SA mixing were investigated.The results indicate that there are some differences in the measurement results obtained using different tracer gases,wherein the deviation between CO and CO_(2) ranges from 42%to 66%and that between O_(2) and CO_(2) ranges from 45%to 71%in the lower part of the fluidized bed.However,these differences became less pronounced as the bed height increased.Besides,the high solid concentration and fine particle diameter in the CFB may weaken the difference.The measurement results of different tracer gases show the same trends under the variation of operating parameters.Increasing superficial velocity and SA ratio and decreasing particle diameter result in better mixing of the SA.The effect of bed inventory on SA mixing is not monotonic.展开更多
BACKGROUND Aerosols containing disease-causing microorganisms are produced during oral diagnosis and treatment can cause secondary contamination.AIM To investigate the use of graphene material for air disinfection in ...BACKGROUND Aerosols containing disease-causing microorganisms are produced during oral diagnosis and treatment can cause secondary contamination.AIM To investigate the use of graphene material for air disinfection in dental clinics by leveraging its adsorption and antibacterial properties.METHODS Patients who received ultrasonic cleaning at our hospital from April 2023 to April 2024.They were randomly assigned to three groups(n=20 each):Graphene nanocomposite material suction group(Group A),ordinary filter suction group(Group B),and no air suction device group(Group C).The air quality and air colony count in the clinic rooms were assessed before,during,and after the procedure.Additionally,bacterial colony counts were obtained from the air outlets of the suction devices and the filter screens in Groups A and B.RESULTS Before ultrasonic cleaning,no significant differences in air quality PM2.5 and colony counts were observed among the three groups.However,significant differences in air quality PM2.5 and colony counts were noted among the three groups during ultrasonic cleaning and after ultrasonic treatment.Additionally,the number of colonies on the exhaust port of the suction device and the surface of the filter were significantly lower in Group A than in Group B(P=0.000 and P=0.000,respectively).CONCLUSION Graphene nanocomposites can effectively sterilize the air in dental clinics by exerting their antimicrobial effects and may be used to reduce secondary pollution.展开更多
Based on the porosity method and the improved non uniform QUICK scheme, this paper describes a three dimensional computer simulation to predict the flow characteristics in a tangentially fired boiler. The model is ap...Based on the porosity method and the improved non uniform QUICK scheme, this paper describes a three dimensional computer simulation to predict the flow characteristics in a tangentially fired boiler. The model is applied to a 600?MW boiler modeling under different operating conditions of reverse swirl of secondary air. The numerical results achieve reasonable agreement with experimental data. The calculated results of flow field, the pressure distribution, the relative diameter of tangential circle, angular momentum flux in furnace and the velocity distribution index in horizontal gas pass are analyzed in detail. And then the effects of the reverse swirl of secondary air on flue gas imbalance are discussed. Finally a reasonable operating condition of the reverse swirl of secondary air is presented.展开更多
Dry coal separation has been the most significant process in the field of coal beneficiation to date, because of its special advantage of operation with no water consumption. Mineral dry separation research has receiv...Dry coal separation has been the most significant process in the field of coal beneficiation to date, because of its special advantage of operation with no water consumption. Mineral dry separation research has received wide attention, particularly in countries and regions experiencing drought and water shortages. During the process of dense coal gas-solid fluidized bed beneficiation, the material is stratified according to its density; the high density material layer remains at the bed bottom, and thus the high density coarse particle bed becomes an important infuencing factor in fluidized bed stability. In the steady fluidization stage, a small number of large radius bubbles are the direct cause of unsteady fluidization in the tradi- tional fluidized bed. The dispersion effect of the secondary air distribution bed for air flow is mainly apparent in the gas region; when the particle size exceeds 13 mm, the secondary air distribution bed has a synergistic effect on the density stability of the upper fluidized layer. When the particle size is small, especially when less than 6 ram, particles will constantly move, accounting for instability of the secondary air distribution bed and distorting the stability of the upper fluidized bed. Under optimum operation conditions, the probable deviation E of gas-solid separation fluidized with a high density coarse particle layer can be as low as 0.085 g/cm3.展开更多
A work on soot emission control simulation in stoker-fired boiler by secondary air has been done. Some models such as k-e, combustion, radiation, and soot Khan-Greeves have been adopted. Soot production and emission h...A work on soot emission control simulation in stoker-fired boiler by secondary air has been done. Some models such as k-e, combustion, radiation, and soot Khan-Greeves have been adopted. Soot production and emission has been reduced by secondary air; the highest mass concentration is reduced from 7.46 × 10^-14 to 6.94 × 10^15; mass concentration of soot is decreased from 1.12 ×10^-15 to 9.25 ×10^-32 in the upper areas.展开更多
The study focused on the effects of the interaction between axial and radial secondary air and the reductive intensity in reduction region on combustion characteristics and NO_(x) emission in a 30 kW preheating combus...The study focused on the effects of the interaction between axial and radial secondary air and the reductive intensity in reduction region on combustion characteristics and NO_(x) emission in a 30 kW preheating combustion system.The results revealed that the interaction and reductive intensity influenced the combustion in the down-fired combustor(DFC) and NO_(x) emission greatly.For the temperature distribution,the interaction caused the position of the main combustion region to shift down as R_(2-12)(ratio of axial secondary air flow to radial secondary air flow) decreased or λ_(2)(total secondary air ratio) increased,and there was the interplay between both of their effects.As R_(3-12)(ratio of first-staged tertiary air flow to second-staged tertiary air flow)increased,the decrease in the reductive intensity also caused the above phenomenon,and the peak temperature increased in this region.For the NO_(x) emission,the interaction affected the NO_(x) reduction adversely when λ_(2) or R_(2-12) was higher,and the range of this effect was larger,so that the NO_x emission increased obviously as they increased.The decrease in the reductive intensity caused the NO_(x) emission increased under the homogeneous reduction mechanism,while was unchanged at a high level under the heterogeneous reduction mechanism.For the combustion efficiency,the interaction improved the combustion efficiency as λ_(2) increased when R_(2-12) was lower,while reduced it as λ_(2) increased excessively when R_(2-12) was higher.The proper decrease in the reductive intensity caused the combustion efficiency increased obviously,while was hardly improved further when the intensity decreased excessively.In this study,the lowest NO_(x) emission was only 41.75 mg/m^(3) without sacrificing the combustion efficiency by optimizing the interaction and reductive intensity.展开更多
基金the Key Project of the National Research Program of China(2020YFB0606201)。
文摘A multitracer-gas method was proposed to study the secondary air(SA)mixing along the bed height in a circulating fluidized bed(CFB)using carbon monoxide(CO),oxygen(O_(2)),and carbon dioxide(CO_(2))as tracer gases.Experiments were carried out on a cold CFB test rig with a cross-section of 0.42 m×0.73 m and a height of 5.50 m.The effects of superficial velocity,SA ratio,bed inventory,and particle diameter on the SA mixing were investigated.The results indicate that there are some differences in the measurement results obtained using different tracer gases,wherein the deviation between CO and CO_(2) ranges from 42%to 66%and that between O_(2) and CO_(2) ranges from 45%to 71%in the lower part of the fluidized bed.However,these differences became less pronounced as the bed height increased.Besides,the high solid concentration and fine particle diameter in the CFB may weaken the difference.The measurement results of different tracer gases show the same trends under the variation of operating parameters.Increasing superficial velocity and SA ratio and decreasing particle diameter result in better mixing of the SA.The effect of bed inventory on SA mixing is not monotonic.
基金The Natural Science Research Project of Minhang District,No.2021MHZ070.
文摘BACKGROUND Aerosols containing disease-causing microorganisms are produced during oral diagnosis and treatment can cause secondary contamination.AIM To investigate the use of graphene material for air disinfection in dental clinics by leveraging its adsorption and antibacterial properties.METHODS Patients who received ultrasonic cleaning at our hospital from April 2023 to April 2024.They were randomly assigned to three groups(n=20 each):Graphene nanocomposite material suction group(Group A),ordinary filter suction group(Group B),and no air suction device group(Group C).The air quality and air colony count in the clinic rooms were assessed before,during,and after the procedure.Additionally,bacterial colony counts were obtained from the air outlets of the suction devices and the filter screens in Groups A and B.RESULTS Before ultrasonic cleaning,no significant differences in air quality PM2.5 and colony counts were observed among the three groups.However,significant differences in air quality PM2.5 and colony counts were noted among the three groups during ultrasonic cleaning and after ultrasonic treatment.Additionally,the number of colonies on the exhaust port of the suction device and the surface of the filter were significantly lower in Group A than in Group B(P=0.000 and P=0.000,respectively).CONCLUSION Graphene nanocomposites can effectively sterilize the air in dental clinics by exerting their antimicrobial effects and may be used to reduce secondary pollution.
文摘Based on the porosity method and the improved non uniform QUICK scheme, this paper describes a three dimensional computer simulation to predict the flow characteristics in a tangentially fired boiler. The model is applied to a 600?MW boiler modeling under different operating conditions of reverse swirl of secondary air. The numerical results achieve reasonable agreement with experimental data. The calculated results of flow field, the pressure distribution, the relative diameter of tangential circle, angular momentum flux in furnace and the velocity distribution index in horizontal gas pass are analyzed in detail. And then the effects of the reverse swirl of secondary air on flue gas imbalance are discussed. Finally a reasonable operating condition of the reverse swirl of secondary air is presented.
基金the Key Project of National Fundamental Research and Development of China (No. 2012CB214904)the National Natural Science Foundation of China for Innovative Research Group (No. 51221462)+1 种基金the National Natural Science Foundation of China (Nos. 51134022 and 51174203)Specialized Research Fund for the Doctoral Program of Higher Education (No. 20120095130001)
文摘Dry coal separation has been the most significant process in the field of coal beneficiation to date, because of its special advantage of operation with no water consumption. Mineral dry separation research has received wide attention, particularly in countries and regions experiencing drought and water shortages. During the process of dense coal gas-solid fluidized bed beneficiation, the material is stratified according to its density; the high density material layer remains at the bed bottom, and thus the high density coarse particle bed becomes an important infuencing factor in fluidized bed stability. In the steady fluidization stage, a small number of large radius bubbles are the direct cause of unsteady fluidization in the tradi- tional fluidized bed. The dispersion effect of the secondary air distribution bed for air flow is mainly apparent in the gas region; when the particle size exceeds 13 mm, the secondary air distribution bed has a synergistic effect on the density stability of the upper fluidized layer. When the particle size is small, especially when less than 6 ram, particles will constantly move, accounting for instability of the secondary air distribution bed and distorting the stability of the upper fluidized bed. Under optimum operation conditions, the probable deviation E of gas-solid separation fluidized with a high density coarse particle layer can be as low as 0.085 g/cm3.
文摘A work on soot emission control simulation in stoker-fired boiler by secondary air has been done. Some models such as k-e, combustion, radiation, and soot Khan-Greeves have been adopted. Soot production and emission has been reduced by secondary air; the highest mass concentration is reduced from 7.46 × 10^-14 to 6.94 × 10^15; mass concentration of soot is decreased from 1.12 ×10^-15 to 9.25 ×10^-32 in the upper areas.
基金Youth Innovation Promotion Association,CAS (2019148)CAS Project for Young Scientists in Basic Research (YSBR-028)the National Natural Science Foundation of China (No.52006233) are gratefully acknowledged。
文摘The study focused on the effects of the interaction between axial and radial secondary air and the reductive intensity in reduction region on combustion characteristics and NO_(x) emission in a 30 kW preheating combustion system.The results revealed that the interaction and reductive intensity influenced the combustion in the down-fired combustor(DFC) and NO_(x) emission greatly.For the temperature distribution,the interaction caused the position of the main combustion region to shift down as R_(2-12)(ratio of axial secondary air flow to radial secondary air flow) decreased or λ_(2)(total secondary air ratio) increased,and there was the interplay between both of their effects.As R_(3-12)(ratio of first-staged tertiary air flow to second-staged tertiary air flow)increased,the decrease in the reductive intensity also caused the above phenomenon,and the peak temperature increased in this region.For the NO_(x) emission,the interaction affected the NO_(x) reduction adversely when λ_(2) or R_(2-12) was higher,and the range of this effect was larger,so that the NO_x emission increased obviously as they increased.The decrease in the reductive intensity caused the NO_(x) emission increased under the homogeneous reduction mechanism,while was unchanged at a high level under the heterogeneous reduction mechanism.For the combustion efficiency,the interaction improved the combustion efficiency as λ_(2) increased when R_(2-12) was lower,while reduced it as λ_(2) increased excessively when R_(2-12) was higher.The proper decrease in the reductive intensity caused the combustion efficiency increased obviously,while was hardly improved further when the intensity decreased excessively.In this study,the lowest NO_(x) emission was only 41.75 mg/m^(3) without sacrificing the combustion efficiency by optimizing the interaction and reductive intensity.