Previous results show that the floating reference theory(FRT)is an effective tool to reduce the infuence of interference factors on noninvasive blood glucose sensing by near infrared spectros-copy(NIRS).It is the key ...Previous results show that the floating reference theory(FRT)is an effective tool to reduce the infuence of interference factors on noninvasive blood glucose sensing by near infrared spectros-copy(NIRS).It is the key to measure the floating reference point(FRP)precisely for the application of FRT.Monte Carlo(MC)simulation has been introduced to quantitatively in-vestigate the effects of positioning errors and light source drifts on measuring FRP.In this article,thinning and calculating method(TCM)is proposed to quantify the positioning error.Mean-while,the normalization process(NP)is developed to significantly reduce the error induced by light source drift.The results according to TCM show that 7 purm deviations in positioning can generate about 10.63%relative error in FRP.It is more noticeable that 1%fluctuation in light source intensity may lead to 12.21%relative errors.Gratifyingly,the proposed NP model can effectively reduce the error caused by light source drift.Therefore,the measurement system for FRPs must meet that the positioning error is less than 7 purm,and the light source drift is kept within 1%.Furthermore,an improvement for measurement system is proposed in order to take advantage of the NP model.展开更多
基金the National High Technology Research and Development Program of China(863 Program:2012AA022602)the 111 Project(B07014)and Tianjin Natural Science Foundation(No.16JCZDJC31200).
文摘Previous results show that the floating reference theory(FRT)is an effective tool to reduce the infuence of interference factors on noninvasive blood glucose sensing by near infrared spectros-copy(NIRS).It is the key to measure the floating reference point(FRP)precisely for the application of FRT.Monte Carlo(MC)simulation has been introduced to quantitatively in-vestigate the effects of positioning errors and light source drifts on measuring FRP.In this article,thinning and calculating method(TCM)is proposed to quantify the positioning error.Mean-while,the normalization process(NP)is developed to significantly reduce the error induced by light source drift.The results according to TCM show that 7 purm deviations in positioning can generate about 10.63%relative error in FRP.It is more noticeable that 1%fluctuation in light source intensity may lead to 12.21%relative errors.Gratifyingly,the proposed NP model can effectively reduce the error caused by light source drift.Therefore,the measurement system for FRPs must meet that the positioning error is less than 7 purm,and the light source drift is kept within 1%.Furthermore,an improvement for measurement system is proposed in order to take advantage of the NP model.