Instantaneous and precise velocity sensing is a critical part of research on detonation mechanism and flow evolution.This paper presents a novel multi-projection tunable diode laser absorption spectroscopy solution,to...Instantaneous and precise velocity sensing is a critical part of research on detonation mechanism and flow evolution.This paper presents a novel multi-projection tunable diode laser absorption spectroscopy solution,to provide a real-time and reliable measurement of velocity distribution in detonation exhaust flow with obvious nonuniformity.Relations are established between overlapped spectrums along probing beams and Gauss velocity distribution phantom according to the frequency shifts and tiny variations in components of light-of-sight absorbance profiles at low frequencies analyzed by the fast Fourier transform.With simulated optical measurement using H2O feature at 7185.6 cm-1 carried out on a phantom generated using a simulation of two-phase detonation by a two-fluid model,this method demonstrates a satisfying performance on recovery of velocity distribution profiles in supersonic flow even with a noise equivalent absorbance up to 2×10^(-3).This method is applied to the analysis of rapidly decreasing velocity during a complete working cycle in the external flow field of an air-gasoline detonation tube operating at 25 Hz,and results show the velocity in the core flow field would be much larger than the arithmetic average from traditional tunable diode laser doppler velocimetry.This proposed velocity distribution sensor would reconstruct nonuniform velocity distribution of high-speed flow in low cost and simple operations,which broadens the possibility for applications in research on the formation and propagation of external flow filed of detonation tube.展开更多
The present paper has investigated the development of mesoscale and microscale disturbance superimposed on three-dimensional nonuniform flow, which extends the work of Zeng et al. The separating effect of the variatio...The present paper has investigated the development of mesoscale and microscale disturbance superimposed on three-dimensional nonuniform flow, which extends the work of Zeng et al. The separating effect of the variation of the horizontal and vertical scale of the disturbances has been found. Moreover, the propagating paths of the disturbances have also been discussed qualitatively.展开更多
Gas-liquid flow in simple systems consisting of capillaries is analyzed by theory of irreversible thermodynamics so as to shed light on induction of nonuniformity of multiphase flow. By the Prigogine’s theorem of min...Gas-liquid flow in simple systems consisting of capillaries is analyzed by theory of irreversible thermodynamics so as to shed light on induction of nonuniformity of multiphase flow. By the Prigogine’s theorem of minimum entropy production, stability of uniform two-phase flow and possible transition to nonuniform distribution are discussed. The analysis of model systems suggests potential application of irreversible thermodynamics to research of multiphase hydrodynamics in chemical reactors.展开更多
Laminar flow and heat transfer in different protruding-edged plate systems are modelled and analyzed in the present work. These include the Parallel Flow (PF) and the Counter Flow (CF) protruding-edgedplate exchangers...Laminar flow and heat transfer in different protruding-edged plate systems are modelled and analyzed in the present work. These include the Parallel Flow (PF) and the Counter Flow (CF) protruding-edgedplate exchangers as well as those systems being subjected to Constant Wall Temperature (CWT) and Uniform Heat Flux (UHF) conditions. These systems are subjected to normal free stream having both power-law velocity profile and same average velocity. The continuity, momentum and energy equations are transformed to either similarity or nonsimilar equations and then solved by using well validated finite difference methods. Accurate correlations for various flow and heat transfer parameters are obtained. It is found that there are specific power-law indices that maximize the heat transfer in both PF and CF systems. The maximum reported enhancement ratios are 1.075 and 1.109 for the PF and CF systems, respectively, at Pr = 100. These ratios are 1.076 and 1.023 for CWT and UHF conditions, respectively, at Pr = 128. Per same friction force, the CF system is preferable over the PF system only when the power-law indices are smaller than zero. Finally, this work demonstrates that by appropriately distributing the free stream velocity, the heat transfer from a plate can be increased up to 10% fold.展开更多
In this article, we present accurate analytical solutions for boundary layer flow and heat transfer of an incompressible and electrically conducting viscoelastic fluid over a linearly stretching surface subject to a t...In this article, we present accurate analytical solutions for boundary layer flow and heat transfer of an incompressible and electrically conducting viscoelastic fluid over a linearly stretching surface subject to a transverse uniform magnetic field using the homotopy analysis method (HAM) for two general types of non-isothermal boundary conditions. In addition, we demonstrate that the previously reported analytical solutions for the temperature field given in terms of Kummer's function do not converge at the boundary. We provide a graphical and numerical demonstration of the convergence of the HAM solutions and tabulate the effects of various parameters on the skin friction coefficient and wall heat transfer.展开更多
基金the China Scholarship Council(Grant No.201906845059)the Young Scientists Found of the Natural Science Foundation of Jiangsu Province,China(Grant No.BK20190439)the Fundamental Research Funds of National Key Laboratory of Transient Physics(Grant No.6142604200202)。
文摘Instantaneous and precise velocity sensing is a critical part of research on detonation mechanism and flow evolution.This paper presents a novel multi-projection tunable diode laser absorption spectroscopy solution,to provide a real-time and reliable measurement of velocity distribution in detonation exhaust flow with obvious nonuniformity.Relations are established between overlapped spectrums along probing beams and Gauss velocity distribution phantom according to the frequency shifts and tiny variations in components of light-of-sight absorbance profiles at low frequencies analyzed by the fast Fourier transform.With simulated optical measurement using H2O feature at 7185.6 cm-1 carried out on a phantom generated using a simulation of two-phase detonation by a two-fluid model,this method demonstrates a satisfying performance on recovery of velocity distribution profiles in supersonic flow even with a noise equivalent absorbance up to 2×10^(-3).This method is applied to the analysis of rapidly decreasing velocity during a complete working cycle in the external flow field of an air-gasoline detonation tube operating at 25 Hz,and results show the velocity in the core flow field would be much larger than the arithmetic average from traditional tunable diode laser doppler velocimetry.This proposed velocity distribution sensor would reconstruct nonuniform velocity distribution of high-speed flow in low cost and simple operations,which broadens the possibility for applications in research on the formation and propagation of external flow filed of detonation tube.
文摘The present paper has investigated the development of mesoscale and microscale disturbance superimposed on three-dimensional nonuniform flow, which extends the work of Zeng et al. The separating effect of the variation of the horizontal and vertical scale of the disturbances has been found. Moreover, the propagating paths of the disturbances have also been discussed qualitatively.
基金the National Natural Science Foundation of China
文摘Gas-liquid flow in simple systems consisting of capillaries is analyzed by theory of irreversible thermodynamics so as to shed light on induction of nonuniformity of multiphase flow. By the Prigogine’s theorem of minimum entropy production, stability of uniform two-phase flow and possible transition to nonuniform distribution are discussed. The analysis of model systems suggests potential application of irreversible thermodynamics to research of multiphase hydrodynamics in chemical reactors.
文摘Laminar flow and heat transfer in different protruding-edged plate systems are modelled and analyzed in the present work. These include the Parallel Flow (PF) and the Counter Flow (CF) protruding-edgedplate exchangers as well as those systems being subjected to Constant Wall Temperature (CWT) and Uniform Heat Flux (UHF) conditions. These systems are subjected to normal free stream having both power-law velocity profile and same average velocity. The continuity, momentum and energy equations are transformed to either similarity or nonsimilar equations and then solved by using well validated finite difference methods. Accurate correlations for various flow and heat transfer parameters are obtained. It is found that there are specific power-law indices that maximize the heat transfer in both PF and CF systems. The maximum reported enhancement ratios are 1.075 and 1.109 for the PF and CF systems, respectively, at Pr = 100. These ratios are 1.076 and 1.023 for CWT and UHF conditions, respectively, at Pr = 128. Per same friction force, the CF system is preferable over the PF system only when the power-law indices are smaller than zero. Finally, this work demonstrates that by appropriately distributing the free stream velocity, the heat transfer from a plate can be increased up to 10% fold.
文摘In this article, we present accurate analytical solutions for boundary layer flow and heat transfer of an incompressible and electrically conducting viscoelastic fluid over a linearly stretching surface subject to a transverse uniform magnetic field using the homotopy analysis method (HAM) for two general types of non-isothermal boundary conditions. In addition, we demonstrate that the previously reported analytical solutions for the temperature field given in terms of Kummer's function do not converge at the boundary. We provide a graphical and numerical demonstration of the convergence of the HAM solutions and tabulate the effects of various parameters on the skin friction coefficient and wall heat transfer.