In order to reveal the complex network characteristics and evolution principle of China aviation network,the probability distribution and evolution trace of node nearest neighbor average degree of China aviation netwo...In order to reveal the complex network characteristics and evolution principle of China aviation network,the probability distribution and evolution trace of node nearest neighbor average degree of China aviation network were studied based on the statistics data of China civil aviation network in 1988,1994,2001,2008 and 2015.According to the theory and method of complex network,the network system was constructed with the city where the airport was located as the network node and the route between cities as the edge of the network.Based on the statistical data,the nearest neighbor average degrees of nodes in China aviation network in 1988,1994,2001,2008 and 2015 were calculated.Using the probability statistical analysis method,it was found that the nearest neighbor average degree had the probability distribution of normal function and the position parameters and scale parameters of the probability distribution had linear evolution trace.展开更多
Corrosion test data were measured using non-destructive electrochemical techniques and analysed for studying inhibition effectiveness by different concentrations of NazCr207 on the corrosion of concrete steel-rehar in...Corrosion test data were measured using non-destructive electrochemical techniques and analysed for studying inhibition effectiveness by different concentrations of NazCr207 on the corrosion of concrete steel-rehar in NaC1 and in H2SO4 media. For these, specifications of ASTM G16-95 R04 were combined with the normal and the Gumbel probability density functions as model analytical methods for addressing issues of conflicting reports of inhibitor effectiveness that had generated concerns. Results show that reinforced concrete samples admixed with concentrations having 4 g (0.012 7 tool), 8 g (0.025 4 mol) and 6 g (0.019 l tool) NaaCr207 exhibited, in that order, high inhibition effectiveness, with respective efficiency, r/, of (90.46±1.30)%, (88.41+2.24)% and (84.87±4.74)%, in the NaC1 medium. These exhibit good agreements within replicates and statistical methods for the samples. Also, optimal inhibition effectiveness model in the H2SO4 medium was exhibited by 8 g (0.025 4 mol) Na2Cr207 concentration having r/=(78.44±1.10)%. These bear implications for addressing conflicting test data in the study of effective inhibitors for mitigating steel-rebar corrosion in aggressive environments.展开更多
The quality of radiation therapy depends on the ability to maximize the tumor control probability while minimizing the normal tissue complication probability.Both of these two quantities are directly related to the ac...The quality of radiation therapy depends on the ability to maximize the tumor control probability while minimizing the normal tissue complication probability.Both of these two quantities are directly related to the accuracy of dose distributions calculated by treatment planning systems.The commonly used dose calculation algorithms in the treatment planning systems are reviewed in this work.The accuracy comparisons among these algorithms are illustrated by summarizing the highly cited research papers on this topic.Further,the correlation between the algorithms and tumor control probability/normal tissue complication probability values are manifested by several recent studies from different groups.All the cases demonstrate that dose calculation algorithms play a vital role in radiation therapy.展开更多
文摘In order to reveal the complex network characteristics and evolution principle of China aviation network,the probability distribution and evolution trace of node nearest neighbor average degree of China aviation network were studied based on the statistics data of China civil aviation network in 1988,1994,2001,2008 and 2015.According to the theory and method of complex network,the network system was constructed with the city where the airport was located as the network node and the route between cities as the edge of the network.Based on the statistical data,the nearest neighbor average degrees of nodes in China aviation network in 1988,1994,2001,2008 and 2015 were calculated.Using the probability statistical analysis method,it was found that the nearest neighbor average degree had the probability distribution of normal function and the position parameters and scale parameters of the probability distribution had linear evolution trace.
文摘Corrosion test data were measured using non-destructive electrochemical techniques and analysed for studying inhibition effectiveness by different concentrations of NazCr207 on the corrosion of concrete steel-rehar in NaC1 and in H2SO4 media. For these, specifications of ASTM G16-95 R04 were combined with the normal and the Gumbel probability density functions as model analytical methods for addressing issues of conflicting reports of inhibitor effectiveness that had generated concerns. Results show that reinforced concrete samples admixed with concentrations having 4 g (0.012 7 tool), 8 g (0.025 4 mol) and 6 g (0.019 l tool) NaaCr207 exhibited, in that order, high inhibition effectiveness, with respective efficiency, r/, of (90.46±1.30)%, (88.41+2.24)% and (84.87±4.74)%, in the NaC1 medium. These exhibit good agreements within replicates and statistical methods for the samples. Also, optimal inhibition effectiveness model in the H2SO4 medium was exhibited by 8 g (0.025 4 mol) Na2Cr207 concentration having r/=(78.44±1.10)%. These bear implications for addressing conflicting test data in the study of effective inhibitors for mitigating steel-rebar corrosion in aggressive environments.
基金Supported by In part,under a grant with the Pennsylvania Department of Health
文摘The quality of radiation therapy depends on the ability to maximize the tumor control probability while minimizing the normal tissue complication probability.Both of these two quantities are directly related to the accuracy of dose distributions calculated by treatment planning systems.The commonly used dose calculation algorithms in the treatment planning systems are reviewed in this work.The accuracy comparisons among these algorithms are illustrated by summarizing the highly cited research papers on this topic.Further,the correlation between the algorithms and tumor control probability/normal tissue complication probability values are manifested by several recent studies from different groups.All the cases demonstrate that dose calculation algorithms play a vital role in radiation therapy.