The situation and status of the research work on the next higher transmission voltage for Northwest Power Grid in China are briefly presented in this paper. It has been preliminarily determined that 750 kV will be ado...The situation and status of the research work on the next higher transmission voltage for Northwest Power Grid in China are briefly presented in this paper. It has been preliminarily determined that 750 kV will be adopted as the next higher transmission voltage to the 330 kV being used. In consideration of the temporary slowing down of the growth of electric power industry in Northwest China and the advance of the.research work on nation--wide interconnection, the authors put forward their views on this problem.展开更多
Being abundant in hydropower, coal, wind energy and solar energy etc., Northwest China is an important energy base with great potential. In recent years, along with the vigorous development of the energy base,
新疆电网以750 kV电压等级线路接入西北主网后,互联电网的动态特性、振荡模式发生了变化,新增了一个新疆电网对西北主网的区域间振荡模式。新疆内部和西北主网内部主要断面的动态稳定水平没有下降,新疆电网内部局部地区仍存在弱阻尼振...新疆电网以750 kV电压等级线路接入西北主网后,互联电网的动态特性、振荡模式发生了变化,新增了一个新疆电网对西北主网的区域间振荡模式。新疆内部和西北主网内部主要断面的动态稳定水平没有下降,新疆电网内部局部地区仍存在弱阻尼振荡模式。通过协调优化新疆电网内部北疆西部地区部分机组的励磁系统自动电压调节器(automatic voltage regulator,AVR)和电力系统稳定器(power system stabilizer,PSS)参数,可提高系统的阻尼水平,并在一定程度上解决了该地区水电窝电现象。开展了实际互联电网系统扰动试验,实测数据验证了仿真计算结果的准确性,通过扰动试验掌握了互联电网的动态特性和系统阻尼水平。研究综合运用了时域和频域的方法,并以频率计算为主,辅以时域分析校验。展开更多
文摘The situation and status of the research work on the next higher transmission voltage for Northwest Power Grid in China are briefly presented in this paper. It has been preliminarily determined that 750 kV will be adopted as the next higher transmission voltage to the 330 kV being used. In consideration of the temporary slowing down of the growth of electric power industry in Northwest China and the advance of the.research work on nation--wide interconnection, the authors put forward their views on this problem.
文摘Being abundant in hydropower, coal, wind energy and solar energy etc., Northwest China is an important energy base with great potential. In recent years, along with the vigorous development of the energy base,
文摘新疆电网以750 kV电压等级线路接入西北主网后,互联电网的动态特性、振荡模式发生了变化,新增了一个新疆电网对西北主网的区域间振荡模式。新疆内部和西北主网内部主要断面的动态稳定水平没有下降,新疆电网内部局部地区仍存在弱阻尼振荡模式。通过协调优化新疆电网内部北疆西部地区部分机组的励磁系统自动电压调节器(automatic voltage regulator,AVR)和电力系统稳定器(power system stabilizer,PSS)参数,可提高系统的阻尼水平,并在一定程度上解决了该地区水电窝电现象。开展了实际互联电网系统扰动试验,实测数据验证了仿真计算结果的准确性,通过扰动试验掌握了互联电网的动态特性和系统阻尼水平。研究综合运用了时域和频域的方法,并以频率计算为主,辅以时域分析校验。