BACKGROUND There are very few cases of cardiac occluder detachment,and it is rare to completely remove the occluder using interventional methods without undergoing thoracotomy surgery after detachment.This case innova...BACKGROUND There are very few cases of cardiac occluder detachment,and it is rare to completely remove the occluder using interventional methods without undergoing thoracotomy surgery after detachment.This case innovatively used ultrasound guidance combined with digital subtraction angiography(DSA)to completely remove the occluder,accumulating some experience.CASE SUMMARY The patient underwent left atrial appendage occlusion surgery in our hospital due to atrial fibrillation.After the surgery,the occluder fell off and became free in the left ventricle,which is very dangerous.We innovatively used ultrasound guidance,combined with DSA,and interventional surgery to successfully capture the free occluder using a catcher,completely remove it,and then re implant a new left atrial appendage occluder.After the surgery,the patient recovered very well.CONCLUSION The size selection of the occluder is slightly conservative,and the shape of the left atrial appendage opening is irregular.展开更多
Background:Transcatheter closure of patent foramen ovale(PFO)has been widely accepted as a highly effective way to treat high-risk PFO-related diseases.However,traditional non-degradable occluders made of metal alloys...Background:Transcatheter closure of patent foramen ovale(PFO)has been widely accepted as a highly effective way to treat high-risk PFO-related diseases.However,traditional non-degradable occluders made of metal alloys will permanently exist in the body,resulting in thrombosis,valve damage,hemolysis,arrhythmia,or other complications.The biodegradable PFO occluder developed by Shanghai Mallow Medical Instrument Co.,Ltd.,China can be fully absorbed and degrade into nontoxic ingredients,reducing postoperative complications.Objectives:To study the safety and efficacy of biodegradable PFO occluders in treating PFO.Methods:This single-center clinical trial collected 30 patients treated with a biodegradable PFO occluder.The follow-up period lasted 12 months to analyze the echocardiographic characteristics and headache relief through HIT-6 scores.Results:The immediate success rate was 100%,with no intraoperative severe occlusion-related complications.The contrast transcranial Doppler(cTCD)at 12 months showed that all patients’right-to-left shunts(RLS)were grade I or 0 with no serious postoperative complications,indicating the overall success rate was 100%.The biodegradable PFO occluder mostly degraded six months after the occlusion.Conclusion:PFO closure with a Mallow biodegradable occluder is safe and effective and has no severe complications.展开更多
Objective:This study was designed to determine the long-term safety and efficacy of using the Amplatzer Duct Occluder II(ADO II)for the closure of various ventricular septal defects(VSDs).Methods:From January 2011 to ...Objective:This study was designed to determine the long-term safety and efficacy of using the Amplatzer Duct Occluder II(ADO II)for the closure of various ventricular septal defects(VSDs).Methods:From January 2011 to December 2019,selected VSD patients were treated through transcatheter intervention using ADO II occluders.The closure results and complications from 188 patients,involving 167 perimembranous ventricular septal defects(pmVSDs),9 intracristal VSDs,11 post surgery residual shunts and 1 post closure residual shunt with the mean outlet diameter3.1±0.8 mm under angiography,were enrolled in this study.Results:The success rate was 98.9%for all procedures.During the median 77-month follow-up period,no cases of complete atrioventricular block(cAVB),infective endocarditis or death occurred.One major adverse event(0.5%)was recorded:cerebrovascular accident occurred 1 day after the procedure in one patient who was transferred to the neurology department.The residual shunt rate was 44.6%,which was the most common minor adverse event.The cardiac conduction block rate was 4.3%.Specifically,one pmVSD patient developed intermittent LBBB during the 28-month follow-up.There were 3 patients(1.6%)with new-onset mild tricuspid insufficiency,and the insufficiency degree was stable during follow-up.There was no new-onset aortic insufficiency that occurred.Conclusions:Transcatheter closure of pmVSDs,some intracristal VSDs,some postsurgery or postclosure residual shunts using ADO II occluders were both safe and effective and yielded excellent long-term results in selected patients.展开更多
Major aortopulmonary collateral arteries (MAPCAs) are congenital vessels that arise from the aorta or its first-order branches and are distally connected to the pulmonary arterial vasculature, thereby providing pulmon...Major aortopulmonary collateral arteries (MAPCAs) are congenital vessels that arise from the aorta or its first-order branches and are distally connected to the pulmonary arterial vasculature, thereby providing pulmonary blood flow. MAPCAs are often associated with cyanotic congenital heart disease with decreased pulmonary blood flow. Isolated MAPCAs are rare in patients without congenital heart disease with structurally normal hearts. Sometimes, isolated congenital MAPCAs can occur without any lung disease. Isolated MAPCAs represent the occurrence of collaterals in the absence of underlying heart disease, which commonly presents as heart failure, recurrent respiratory tract infection, and pulmonary artery hypertension. We report a rare case of congestive heart failure in a 6-year-old patient with dual arterial supply to an otherwise normal right lung, with a normal bronchial tree, and a structurally normal heart. The patient was successfully managed by the closure of collaterals by Amplatzer vascular plugs II (AVPII) and Amplatzer Piccolo Occluders.展开更多
Objectives To evaluate the changes of the left ventricular form and function after closure of moderate- to large-sized patent ductus arteriosus (PDA) using domestic-made occluder. Methods 22 patients with PDA underw...Objectives To evaluate the changes of the left ventricular form and function after closure of moderate- to large-sized patent ductus arteriosus (PDA) using domestic-made occluder. Methods 22 patients with PDA underwent procedure successfuly using the domestic-made occluder. The mean PDA minimal (pulmonary end) diameter by aortography was 8.01±2.47 mm (range 4 to 15.5mm). All patients underwent transthoracic echocardiography (TTE) study before the procedure and the following 48 hours, 3 months after procedure. Results All patients had been implanted the domestic-made occluders successfully with no haematolysis, infective endocarditis, recanalization and other complications. At 3 months, mean LVED was decreased to 50.05±6.55 mm, compared to the pre-procedure (55.67 ±8.48 mm), P 〈 0.01. After 48 hours of the procedure, mean LVEDD and LVESD decreased significantly (156.22± 51.40 mL vs. 121.28±35.73ml, 57.16±32.07 mL vs. 45.88±15.97 mL), P〈 0.05. At 3 months, LVEDD decreased to 110.93 ±15.08ml, LVSV reached 73.50± 9.19 mL, compared to the pre-procedure, P 〈 0.01. LVESD decreased to 37.43±10.44 mL at 3 months, P〈 0.05. Conclusions Closuring of moderate- to largesized PDA using domestic-made occluder is effective and safe. After procedure, left ventricular form and function improved.展开更多
Dissimilar metal joining between NiTi shape memory alloy(SMA) and stainless steel was conducted.A cluster of NiTi SMA wires were first joined with tungsten inert gas(TIG) welding process,then the NiTi SMA TIG weld...Dissimilar metal joining between NiTi shape memory alloy(SMA) and stainless steel was conducted.A cluster of NiTi SMA wires were first joined with tungsten inert gas(TIG) welding process,then the NiTi SMA TIG weld was welded to a stainless steel pipe with laser spot welding process.The microstructure of the welds was examined with an optical microscope and the elemental distribution in the welds was measured by electron probe microanalysis(EPMA).The results show that TiC compounds dispersively distribute in the NiTi SMA TIG weld.However,the amount of TiC compounds greatly decreases around the fusion boundary of the laser spot weld between the NiTi SMA and stainless steel.Mutual diffusion between NiTi shape memory alloy and stainless steel happen within a short distance near the fusion boundary,and intermetallic compounds such as Ni3Ti+(Fe,Ni)Ti appear around the fusion boundary.展开更多
With the integration of depth technology Made in China 2025 has established an production pattern of information and personalization,it needs complex and innovative workers,which has brought severe challenges to talen...With the integration of depth technology Made in China 2025 has established an production pattern of information and personalization,it needs complex and innovative workers,which has brought severe challenges to talent training mode.Changing the thought of talent cultivation,improving the professional setting and construction,optimizing course offered mode,innovating teaching organization form,speeding up the cooperative education mode,reconstructing teachers team,accelerating the establishment of personnel training laws and regulations,these are the positive strategic choices for China to face challenges.展开更多
Authorities from the China Aerospace Science and Technology Corporation(CASC)announced that all core devices used in the BeiDou 3 Satellites are domestically made.A program made and broadcasted by China Central Televi...Authorities from the China Aerospace Science and Technology Corporation(CASC)announced that all core devices used in the BeiDou 3 Satellites are domestically made.A program made and broadcasted by China Central Television(CCTV)reported on December 3,2018,that all parts and core devices used for BeiDou 3 navigation satellites are“100%made in China”,and key technologies enable“complete independence and control”within China.展开更多
Made in China 2025 Strategy requires a large number of high skilled talents,which the high-skilled talents are the core backbone of skilled workers and a significant force to promote technological innovation and reali...Made in China 2025 Strategy requires a large number of high skilled talents,which the high-skilled talents are the core backbone of skilled workers and a significant force to promote technological innovation and realize the transformation of scientific and technological achievements.In this study,combined with automotive spraying industry characteristics,four cultivation strategies are established by the construction of the system of high-skilled talent formation,training mode of on-campus+on-job highskilled talents,the common trail of national certification and enterprise certification and the star system spiraling excitation in order to create a new growth path for the cultivation of high-skilled talents in automobile spraying.展开更多
BACKGROUND An atrial septal defect is a common condition and accounts for 25%of adult congenital heart diseases.Transcatheter occlusion is a widely used technique for the treatment of secondary aperture-type atrial se...BACKGROUND An atrial septal defect is a common condition and accounts for 25%of adult congenital heart diseases.Transcatheter occlusion is a widely used technique for the treatment of secondary aperture-type atrial septal defects(ASDs).CASE SUMMARY A 30-year-old female patient was diagnosed with ASD by transthoracic echocardiography(TTE)1 year ago.The electrocardiogram showed a heart rate of 88 beats per minute,normal sinus rhythm,and no change in the ST-T wave.After admission,TTE showed an atrial septal defect with a left-to-right shunt,aortic root short-axis section with an ASD diameter of 8 mm,a parasternal four-chamber section with an ASD diameter of 9 mm,and subxiphoid biatrial section with a diameter of 13 mm.Percutaneous occlusion was proposed.The intraoperative TTE scan showed that the atrial septal defect was oval in shape,was located near the root of the aorta,and had a maximum diameter of 13 mm.A 10-F sheath was placed in the right femoral vein,and a 0.035°hard guidewire was used to establish the transport track between the left pulmonary vein and the inferior vena cava.A shape-memory alloy atrial septal occluder with a waist diameter of 20 mm was placed successfully and located correctly.TTE showed that the double disk unfolded well and that the clamping of the atrial septum was smooth.Immediately after the disc was revealed,electrocardiograph monitoring showed that the ST interval of the inferior leads was prolonged,the P waves and QRS waves were separated,a junctional escape rhythm maintained the heart rate,and the blood pressure began to decrease.After removing the occluder,the elevation in the ST segment returned to normal immediately,and the sinus rhythm returned to average approximately 10 min later.After consulting the patient’s family,we finally decided to withdraw from the operation.CONCLUSION Compression of the small coronary artery,which provides an alternative blood supply to the atrioventricular nodule during the operation,leads to the emergence of a complete atrioventricular block.展开更多
Objective To evaluate atrial septal defect(ASD) occlusion employing a small right anterior thoracotomy approach. Methods A total of 21 patients with ASD underwent general anesthesia and 2-3 cm incision was made in the...Objective To evaluate atrial septal defect(ASD) occlusion employing a small right anterior thoracotomy approach. Methods A total of 21 patients with ASD underwent general anesthesia and 2-3 cm incision was made in the fourth right intercostal space.Utilizing transesophageal or transthoracic echocardiography,the occluder was released using a monotube unit. Results All patients were occluded successfully.No patient required open surgery utilizing extracorporeal circulation.There were no major complications and no evidence of residual atrial shunt. Conclusion ASD occlusion via a minimal surgical incision is safe,less invasive,and has excellent outcomes.展开更多
Objective:To evaluate the efficacy of Amplatzer duct occluder II(ADO II)in the treatment of perimembranous ventricular septal defect(pmVSD)in children.Methods:Between June 2017 and June 2020,13 patients with pmVSD had...Objective:To evaluate the efficacy of Amplatzer duct occluder II(ADO II)in the treatment of perimembranous ventricular septal defect(pmVSD)in children.Methods:Between June 2017 and June 2020,13 patients with pmVSD had attempted transcatheter closure using ADO II,seven of patients were used antegrade approach and six of them were used retrograde approach.Results:There were 8 males and 5 females,age from 1 to 7 years,weight from 10.5 to 31.0 kg,and VSD size from 2.0 to 4.0 mm.Procedure was successful in all cases with the outer diameter of the occluders ranging from 4 to 6 mm.No aortic,tricuspid regurgitation or residual shunt was found in the immediate ultrasound assessment.No arrhythmia was observed in the Holter monitoring 3 days after the intervention.Discharge echocardiography indicated complete shunt closure.No evidence of occluder prolapse,malignant arrhythmia,or intensed valve regurgitation was seen on a median follow-up of 18 months(range,6 to 36 months).Conclusions:Based on our experience,ADO II showed good efficacy in the early and middle stages of pediatric pmVSD closures.展开更多
Objectives To evaluate the therapeutic effect of transcatheter Amplatzer device on the closure of ventricular septal defect (VSD). Methods Among 143 patients with VSD, 135 patients with perimembrane VSD and 2 wit...Objectives To evaluate the therapeutic effect of transcatheter Amplatzer device on the closure of ventricular septal defect (VSD). Methods Among 143 patients with VSD, 135 patients with perimembrane VSD and 2 with muscular VSD aged 2.5 -28 years old, were successfully closed with Amplatzer oeeluder device by the pereutaneous guidwire through femoral artery-VSD-femoral vein route under the guidance of fluoroscopy, ventrieulography and transthoracic echocardiography (TIE). The diameters of the VSDs were 2.3-15.7 (6.90±2.76)mm by left ventriculography. Results The success rate of transcatheter closure of VSD with Amplatzer devices was 96%(137/143). Minimal residual amount of shunts were found in one patient, although the shunts was decreased one month after the procedure. There were one patient who had respiratory arrest during the procedure, 7 patients(5%)had conduction disturbance, 3 patients had complete left bundle branch block, 2 patients had complete right bundle branch block, 1 patient had Ⅰ degree atrial-ventricular block and 1 patient had Ⅲ degree atr/al-ventricular block during hospitalization. The diameters of the occluder ranged from 4 to 23 (9.13±3.31)mm and were symmetrical in 122 patients and asymmetrical in 15 patients. Conclusions Transcatheter closure of the perimembranous ventrieular septal defect using Amplatzer VSD occluder device is an efficient method for patients with the perimembranous VSD. The operation is simple with a high success rate and a good effect.展开更多
A 63-year-old man,with previous coronary artery bypass surgery presented with infectious aortitis and a large ascending aorta pseudoaneurysm,causing compression of the left internal mammary graft.Percutaneous interven...A 63-year-old man,with previous coronary artery bypass surgery presented with infectious aortitis and a large ascending aorta pseudoaneurysm,causing compression of the left internal mammary graft.Percutaneous intervention with stenting of the graft followed by closure of the pseudoaneurysm using an atrial septal defect occluder was successfully carried out.展开更多
BACKGROUND The off-label use of various devices has been reported for the transcatheter closure of perimembranous ventricular septal defects(PmVSD) because of serious complications, such as heart block and tricuspid r...BACKGROUND The off-label use of various devices has been reported for the transcatheter closure of perimembranous ventricular septal defects(PmVSD) because of serious complications, such as heart block and tricuspid regurgitation(TR),associated with conventional ventricular septal defect devices. However, whether certain defects such as PmVSD with abnormally attached tricuspid are fit for interventional treatment is still disputable.AIM To explore the feasibility and safety of transcatheter closure of PmVSD with abnormally attached tricuspid chordae tendineae using an improved patent ductus arteriosus(PDA) occluder.METHODS We retrospectively analyzed 20 patients diagnosed with PmVSD with abnormally attached tricuspid chordae tendineae who underwent interventional treatment using an improved PDA occluder at our center from January 2012 to January 2016. Baseline characteristics and procedural and follow-up data were analyzed.RESULTS All 20 patients achieved procedure success. No heart block occurred during the operation. One patient had a transient complete right bundle branch block within48 h post-procedure and reverted to normal rhythm after intravenous injections of dexamethasone for 3 d. For all 20 patients, no residual shunt was observed by transthoracic echocardiography post-procedure. During the average follow-up period of 2.4 years, no severe TR was observed.CONCLUSION Using of the improved PDA occluder for the transcatheter closure of PmVSD with abnormally attached tricuspid chordae tendineae is a safe and promising treatment option. However, long-term follow-up in a large group of patients is still warranted.展开更多
The joint development of teachers and young children is the basis for promoting the development of high-quality preschool education in the new era,and encouraging early childhood teachers to make playthings according ...The joint development of teachers and young children is the basis for promoting the development of high-quality preschool education in the new era,and encouraging early childhood teachers to make playthings according to local conditions is both the fine tradition of China's early childhood education and the direct orientation of China's preschool education policy.Homemade play and teaching aids are some of the methods often used in kindergartens,which skillfully combine young children's daily life objects with toys and early childhood teaching,not only enriching the collective activities of young children but also cultivating children's abilities in various aspects.Kindergarten homemade"play and teaching aids"for early childhood teachers and children have their special educational significance and value,therefore,this paper is based on the children and teachers double subject basis,discussing the homemade"play and teaching aids"for children and teachers of the double subject meanings,and puts forward the realization of the This paper discusses the double-subjective meaning of homemade teaching aids for children and teachers on the basis of the double-subjective foundation of children and teachers,and puts forward specific suggestions for realizing the double-subjectivity of kindergarten homemade teaching aids to enrich the theoretical value and practical significance of homemade teaching aids,to provide theoretical references and support for the relevant staff.展开更多
Background:Communication between the right pulmonary artery(RPA)and left atrium(LA)is a rare cause of central cyanosis in pediatric patients.Case presentation:We describe a 3-year-old female patient with an oxygen sat...Background:Communication between the right pulmonary artery(RPA)and left atrium(LA)is a rare cause of central cyanosis in pediatric patients.Case presentation:We describe a 3-year-old female patient with an oxygen saturation of 70%at admission.The echocardiogram indicated an abnormal color flow Doppler in the LA and she underwent standard cardiac catheterization.The angiography of pulmonary artery revealed a 7.4 mm×7.6 mm fistula between the RPA and LA and achieved successful closure using ventricular septal defect occlusion.Conclusion:The fistula between pulmonary artery and left atrium is an extremely rare but treatable congenital defect.It should be considered in differential diagnosis of cyanosis in children.展开更多
The aim of this study is to investigate the impacts of the sampling strategy of landslide and non-landslide on the performance of landslide susceptibility assessment(LSA).The study area is the Feiyun catchment in Wenz...The aim of this study is to investigate the impacts of the sampling strategy of landslide and non-landslide on the performance of landslide susceptibility assessment(LSA).The study area is the Feiyun catchment in Wenzhou City,Southeast China.Two types of landslides samples,combined with seven non-landslide sampling strategies,resulted in a total of 14 scenarios.The corresponding landslide susceptibility map(LSM)for each scenario was generated using the random forest model.The receiver operating characteristic(ROC)curve and statistical indicators were calculated and used to assess the impact of the dataset sampling strategy.The results showed that higher accuracies were achieved when using the landslide core as positive samples,combined with non-landslide sampling from the very low zone or buffer zone.The results reveal the influence of landslide and non-landslide sampling strategies on the accuracy of LSA,which provides a reference for subsequent researchers aiming to obtain a more reasonable LSM.展开更多
文摘BACKGROUND There are very few cases of cardiac occluder detachment,and it is rare to completely remove the occluder using interventional methods without undergoing thoracotomy surgery after detachment.This case innovatively used ultrasound guidance combined with digital subtraction angiography(DSA)to completely remove the occluder,accumulating some experience.CASE SUMMARY The patient underwent left atrial appendage occlusion surgery in our hospital due to atrial fibrillation.After the surgery,the occluder fell off and became free in the left ventricle,which is very dangerous.We innovatively used ultrasound guidance,combined with DSA,and interventional surgery to successfully capture the free occluder using a catcher,completely remove it,and then re implant a new left atrial appendage occluder.After the surgery,the patient recovered very well.CONCLUSION The size selection of the occluder is slightly conservative,and the shape of the left atrial appendage opening is irregular.
基金supported by the Health and Family Planning Commission of Wuhan Municipality,Grant WX21Z26.
文摘Background:Transcatheter closure of patent foramen ovale(PFO)has been widely accepted as a highly effective way to treat high-risk PFO-related diseases.However,traditional non-degradable occluders made of metal alloys will permanently exist in the body,resulting in thrombosis,valve damage,hemolysis,arrhythmia,or other complications.The biodegradable PFO occluder developed by Shanghai Mallow Medical Instrument Co.,Ltd.,China can be fully absorbed and degrade into nontoxic ingredients,reducing postoperative complications.Objectives:To study the safety and efficacy of biodegradable PFO occluders in treating PFO.Methods:This single-center clinical trial collected 30 patients treated with a biodegradable PFO occluder.The follow-up period lasted 12 months to analyze the echocardiographic characteristics and headache relief through HIT-6 scores.Results:The immediate success rate was 100%,with no intraoperative severe occlusion-related complications.The contrast transcranial Doppler(cTCD)at 12 months showed that all patients’right-to-left shunts(RLS)were grade I or 0 with no serious postoperative complications,indicating the overall success rate was 100%.The biodegradable PFO occluder mostly degraded six months after the occlusion.Conclusion:PFO closure with a Mallow biodegradable occluder is safe and effective and has no severe complications.
基金This study was supported by grant from Doctoral Start-Up Foundation of Liaoning Province of China(2019-BS-266).
文摘Objective:This study was designed to determine the long-term safety and efficacy of using the Amplatzer Duct Occluder II(ADO II)for the closure of various ventricular septal defects(VSDs).Methods:From January 2011 to December 2019,selected VSD patients were treated through transcatheter intervention using ADO II occluders.The closure results and complications from 188 patients,involving 167 perimembranous ventricular septal defects(pmVSDs),9 intracristal VSDs,11 post surgery residual shunts and 1 post closure residual shunt with the mean outlet diameter3.1±0.8 mm under angiography,were enrolled in this study.Results:The success rate was 98.9%for all procedures.During the median 77-month follow-up period,no cases of complete atrioventricular block(cAVB),infective endocarditis or death occurred.One major adverse event(0.5%)was recorded:cerebrovascular accident occurred 1 day after the procedure in one patient who was transferred to the neurology department.The residual shunt rate was 44.6%,which was the most common minor adverse event.The cardiac conduction block rate was 4.3%.Specifically,one pmVSD patient developed intermittent LBBB during the 28-month follow-up.There were 3 patients(1.6%)with new-onset mild tricuspid insufficiency,and the insufficiency degree was stable during follow-up.There was no new-onset aortic insufficiency that occurred.Conclusions:Transcatheter closure of pmVSDs,some intracristal VSDs,some postsurgery or postclosure residual shunts using ADO II occluders were both safe and effective and yielded excellent long-term results in selected patients.
文摘Major aortopulmonary collateral arteries (MAPCAs) are congenital vessels that arise from the aorta or its first-order branches and are distally connected to the pulmonary arterial vasculature, thereby providing pulmonary blood flow. MAPCAs are often associated with cyanotic congenital heart disease with decreased pulmonary blood flow. Isolated MAPCAs are rare in patients without congenital heart disease with structurally normal hearts. Sometimes, isolated congenital MAPCAs can occur without any lung disease. Isolated MAPCAs represent the occurrence of collaterals in the absence of underlying heart disease, which commonly presents as heart failure, recurrent respiratory tract infection, and pulmonary artery hypertension. We report a rare case of congestive heart failure in a 6-year-old patient with dual arterial supply to an otherwise normal right lung, with a normal bronchial tree, and a structurally normal heart. The patient was successfully managed by the closure of collaterals by Amplatzer vascular plugs II (AVPII) and Amplatzer Piccolo Occluders.
基金Items of tackle key problems in science andtechnology, Guangxi (0472002-30)
文摘Objectives To evaluate the changes of the left ventricular form and function after closure of moderate- to large-sized patent ductus arteriosus (PDA) using domestic-made occluder. Methods 22 patients with PDA underwent procedure successfuly using the domestic-made occluder. The mean PDA minimal (pulmonary end) diameter by aortography was 8.01±2.47 mm (range 4 to 15.5mm). All patients underwent transthoracic echocardiography (TTE) study before the procedure and the following 48 hours, 3 months after procedure. Results All patients had been implanted the domestic-made occluders successfully with no haematolysis, infective endocarditis, recanalization and other complications. At 3 months, mean LVED was decreased to 50.05±6.55 mm, compared to the pre-procedure (55.67 ±8.48 mm), P 〈 0.01. After 48 hours of the procedure, mean LVEDD and LVESD decreased significantly (156.22± 51.40 mL vs. 121.28±35.73ml, 57.16±32.07 mL vs. 45.88±15.97 mL), P〈 0.05. At 3 months, LVEDD decreased to 110.93 ±15.08ml, LVSV reached 73.50± 9.19 mL, compared to the pre-procedure, P 〈 0.01. LVESD decreased to 37.43±10.44 mL at 3 months, P〈 0.05. Conclusions Closuring of moderate- to largesized PDA using domestic-made occluder is effective and safe. After procedure, left ventricular form and function improved.
基金Project(50974046/E041607) supported by the National Natural Science Foundation of China
文摘Dissimilar metal joining between NiTi shape memory alloy(SMA) and stainless steel was conducted.A cluster of NiTi SMA wires were first joined with tungsten inert gas(TIG) welding process,then the NiTi SMA TIG weld was welded to a stainless steel pipe with laser spot welding process.The microstructure of the welds was examined with an optical microscope and the elemental distribution in the welds was measured by electron probe microanalysis(EPMA).The results show that TiC compounds dispersively distribute in the NiTi SMA TIG weld.However,the amount of TiC compounds greatly decreases around the fusion boundary of the laser spot weld between the NiTi SMA and stainless steel.Mutual diffusion between NiTi shape memory alloy and stainless steel happen within a short distance near the fusion boundary,and intermetallic compounds such as Ni3Ti+(Fe,Ni)Ti appear around the fusion boundary.
文摘With the integration of depth technology Made in China 2025 has established an production pattern of information and personalization,it needs complex and innovative workers,which has brought severe challenges to talent training mode.Changing the thought of talent cultivation,improving the professional setting and construction,optimizing course offered mode,innovating teaching organization form,speeding up the cooperative education mode,reconstructing teachers team,accelerating the establishment of personnel training laws and regulations,these are the positive strategic choices for China to face challenges.
文摘Authorities from the China Aerospace Science and Technology Corporation(CASC)announced that all core devices used in the BeiDou 3 Satellites are domestically made.A program made and broadcasted by China Central Television(CCTV)reported on December 3,2018,that all parts and core devices used for BeiDou 3 navigation satellites are“100%made in China”,and key technologies enable“complete independence and control”within China.
文摘Made in China 2025 Strategy requires a large number of high skilled talents,which the high-skilled talents are the core backbone of skilled workers and a significant force to promote technological innovation and realize the transformation of scientific and technological achievements.In this study,combined with automotive spraying industry characteristics,four cultivation strategies are established by the construction of the system of high-skilled talent formation,training mode of on-campus+on-job highskilled talents,the common trail of national certification and enterprise certification and the star system spiraling excitation in order to create a new growth path for the cultivation of high-skilled talents in automobile spraying.
文摘BACKGROUND An atrial septal defect is a common condition and accounts for 25%of adult congenital heart diseases.Transcatheter occlusion is a widely used technique for the treatment of secondary aperture-type atrial septal defects(ASDs).CASE SUMMARY A 30-year-old female patient was diagnosed with ASD by transthoracic echocardiography(TTE)1 year ago.The electrocardiogram showed a heart rate of 88 beats per minute,normal sinus rhythm,and no change in the ST-T wave.After admission,TTE showed an atrial septal defect with a left-to-right shunt,aortic root short-axis section with an ASD diameter of 8 mm,a parasternal four-chamber section with an ASD diameter of 9 mm,and subxiphoid biatrial section with a diameter of 13 mm.Percutaneous occlusion was proposed.The intraoperative TTE scan showed that the atrial septal defect was oval in shape,was located near the root of the aorta,and had a maximum diameter of 13 mm.A 10-F sheath was placed in the right femoral vein,and a 0.035°hard guidewire was used to establish the transport track between the left pulmonary vein and the inferior vena cava.A shape-memory alloy atrial septal occluder with a waist diameter of 20 mm was placed successfully and located correctly.TTE showed that the double disk unfolded well and that the clamping of the atrial septum was smooth.Immediately after the disc was revealed,electrocardiograph monitoring showed that the ST interval of the inferior leads was prolonged,the P waves and QRS waves were separated,a junctional escape rhythm maintained the heart rate,and the blood pressure began to decrease.After removing the occluder,the elevation in the ST segment returned to normal immediately,and the sinus rhythm returned to average approximately 10 min later.After consulting the patient’s family,we finally decided to withdraw from the operation.CONCLUSION Compression of the small coronary artery,which provides an alternative blood supply to the atrioventricular nodule during the operation,leads to the emergence of a complete atrioventricular block.
文摘Objective To evaluate atrial septal defect(ASD) occlusion employing a small right anterior thoracotomy approach. Methods A total of 21 patients with ASD underwent general anesthesia and 2-3 cm incision was made in the fourth right intercostal space.Utilizing transesophageal or transthoracic echocardiography,the occluder was released using a monotube unit. Results All patients were occluded successfully.No patient required open surgery utilizing extracorporeal circulation.There were no major complications and no evidence of residual atrial shunt. Conclusion ASD occlusion via a minimal surgical incision is safe,less invasive,and has excellent outcomes.
基金The work was financially supported by the National Natural Science Foundation of China(81770316,81970249 to SLP)Shandong Taishan Scholarship(2018 to SLP)and Qingdao Science and Technology Plan(20-3-4-47-nsh).
文摘Objective:To evaluate the efficacy of Amplatzer duct occluder II(ADO II)in the treatment of perimembranous ventricular septal defect(pmVSD)in children.Methods:Between June 2017 and June 2020,13 patients with pmVSD had attempted transcatheter closure using ADO II,seven of patients were used antegrade approach and six of them were used retrograde approach.Results:There were 8 males and 5 females,age from 1 to 7 years,weight from 10.5 to 31.0 kg,and VSD size from 2.0 to 4.0 mm.Procedure was successful in all cases with the outer diameter of the occluders ranging from 4 to 6 mm.No aortic,tricuspid regurgitation or residual shunt was found in the immediate ultrasound assessment.No arrhythmia was observed in the Holter monitoring 3 days after the intervention.Discharge echocardiography indicated complete shunt closure.No evidence of occluder prolapse,malignant arrhythmia,or intensed valve regurgitation was seen on a median follow-up of 18 months(range,6 to 36 months).Conclusions:Based on our experience,ADO II showed good efficacy in the early and middle stages of pediatric pmVSD closures.
文摘Objectives To evaluate the therapeutic effect of transcatheter Amplatzer device on the closure of ventricular septal defect (VSD). Methods Among 143 patients with VSD, 135 patients with perimembrane VSD and 2 with muscular VSD aged 2.5 -28 years old, were successfully closed with Amplatzer oeeluder device by the pereutaneous guidwire through femoral artery-VSD-femoral vein route under the guidance of fluoroscopy, ventrieulography and transthoracic echocardiography (TIE). The diameters of the VSDs were 2.3-15.7 (6.90±2.76)mm by left ventriculography. Results The success rate of transcatheter closure of VSD with Amplatzer devices was 96%(137/143). Minimal residual amount of shunts were found in one patient, although the shunts was decreased one month after the procedure. There were one patient who had respiratory arrest during the procedure, 7 patients(5%)had conduction disturbance, 3 patients had complete left bundle branch block, 2 patients had complete right bundle branch block, 1 patient had Ⅰ degree atrial-ventricular block and 1 patient had Ⅲ degree atr/al-ventricular block during hospitalization. The diameters of the occluder ranged from 4 to 23 (9.13±3.31)mm and were symmetrical in 122 patients and asymmetrical in 15 patients. Conclusions Transcatheter closure of the perimembranous ventrieular septal defect using Amplatzer VSD occluder device is an efficient method for patients with the perimembranous VSD. The operation is simple with a high success rate and a good effect.
文摘A 63-year-old man,with previous coronary artery bypass surgery presented with infectious aortitis and a large ascending aorta pseudoaneurysm,causing compression of the left internal mammary graft.Percutaneous intervention with stenting of the graft followed by closure of the pseudoaneurysm using an atrial septal defect occluder was successfully carried out.
文摘BACKGROUND The off-label use of various devices has been reported for the transcatheter closure of perimembranous ventricular septal defects(PmVSD) because of serious complications, such as heart block and tricuspid regurgitation(TR),associated with conventional ventricular septal defect devices. However, whether certain defects such as PmVSD with abnormally attached tricuspid are fit for interventional treatment is still disputable.AIM To explore the feasibility and safety of transcatheter closure of PmVSD with abnormally attached tricuspid chordae tendineae using an improved patent ductus arteriosus(PDA) occluder.METHODS We retrospectively analyzed 20 patients diagnosed with PmVSD with abnormally attached tricuspid chordae tendineae who underwent interventional treatment using an improved PDA occluder at our center from January 2012 to January 2016. Baseline characteristics and procedural and follow-up data were analyzed.RESULTS All 20 patients achieved procedure success. No heart block occurred during the operation. One patient had a transient complete right bundle branch block within48 h post-procedure and reverted to normal rhythm after intravenous injections of dexamethasone for 3 d. For all 20 patients, no residual shunt was observed by transthoracic echocardiography post-procedure. During the average follow-up period of 2.4 years, no severe TR was observed.CONCLUSION Using of the improved PDA occluder for the transcatheter closure of PmVSD with abnormally attached tricuspid chordae tendineae is a safe and promising treatment option. However, long-term follow-up in a large group of patients is still warranted.
文摘The joint development of teachers and young children is the basis for promoting the development of high-quality preschool education in the new era,and encouraging early childhood teachers to make playthings according to local conditions is both the fine tradition of China's early childhood education and the direct orientation of China's preschool education policy.Homemade play and teaching aids are some of the methods often used in kindergartens,which skillfully combine young children's daily life objects with toys and early childhood teaching,not only enriching the collective activities of young children but also cultivating children's abilities in various aspects.Kindergarten homemade"play and teaching aids"for early childhood teachers and children have their special educational significance and value,therefore,this paper is based on the children and teachers double subject basis,discussing the homemade"play and teaching aids"for children and teachers of the double subject meanings,and puts forward the realization of the This paper discusses the double-subjective meaning of homemade teaching aids for children and teachers on the basis of the double-subjective foundation of children and teachers,and puts forward specific suggestions for realizing the double-subjectivity of kindergarten homemade teaching aids to enrich the theoretical value and practical significance of homemade teaching aids,to provide theoretical references and support for the relevant staff.
基金This work was supported by a grant from the National Science Foundation of China[Grant No.81700286].
文摘Background:Communication between the right pulmonary artery(RPA)and left atrium(LA)is a rare cause of central cyanosis in pediatric patients.Case presentation:We describe a 3-year-old female patient with an oxygen saturation of 70%at admission.The echocardiogram indicated an abnormal color flow Doppler in the LA and she underwent standard cardiac catheterization.The angiography of pulmonary artery revealed a 7.4 mm×7.6 mm fistula between the RPA and LA and achieved successful closure using ventricular septal defect occlusion.Conclusion:The fistula between pulmonary artery and left atrium is an extremely rare but treatable congenital defect.It should be considered in differential diagnosis of cyanosis in children.
文摘The aim of this study is to investigate the impacts of the sampling strategy of landslide and non-landslide on the performance of landslide susceptibility assessment(LSA).The study area is the Feiyun catchment in Wenzhou City,Southeast China.Two types of landslides samples,combined with seven non-landslide sampling strategies,resulted in a total of 14 scenarios.The corresponding landslide susceptibility map(LSM)for each scenario was generated using the random forest model.The receiver operating characteristic(ROC)curve and statistical indicators were calculated and used to assess the impact of the dataset sampling strategy.The results showed that higher accuracies were achieved when using the landslide core as positive samples,combined with non-landslide sampling from the very low zone or buffer zone.The results reveal the influence of landslide and non-landslide sampling strategies on the accuracy of LSA,which provides a reference for subsequent researchers aiming to obtain a more reasonable LSM.