Occlusal disorder caused by severe worn dentition is one of the most common diseases in the occlusion. Occlusal reconstruction is an important repair method, referring to modify and rebuild the existing occlusion stat...Occlusal disorder caused by severe worn dentition is one of the most common diseases in the occlusion. Occlusal reconstruction is an important repair method, referring to modify and rebuild the existing occlusion status, then to restore the occlusion. During occlusal reconstruction, the digital occlusion analysis system can accurately acquire the occlusion status, in order to guide the reconstruction occlusion accurately and restore the normal function of the oral maxillary system. This paper reviews the concept of occlusal reconstruction, sequence therapy, traditional occlusion analysis methods and the development status and prospect of digital occlusion analysis.展开更多
To tackle the problem of severe occlusions in visual tracking, we propose a hierarchical template-matching method based on a layered appearance model. This model integrates holistic- and part-region matching in order ...To tackle the problem of severe occlusions in visual tracking, we propose a hierarchical template-matching method based on a layered appearance model. This model integrates holistic- and part-region matching in order to locate an object in a coarse-to-fine manner. Furthermore, in order to reduce ambiguity in object localization, only the discriminative parts of an object' s appearance template are chosen for similarity computing with respect to their cornerness measurements. The similarity between parts is computed in a layer-wise manner, and from this, occlusions can be evaluated. When the object is partly occluded, it can be located accurately by matching candidate regions with the appearance template. When it is completely occluded, its location can be predicted from its historical motion information using a Kalman filter. The proposed tracker is tested on several practical image sequences, and the experimental results show that it can consistently provide accurate object location for stable tracking, even for severe occlusions.展开更多
The repeatability of a non-invasive digital protocol proposed to evaluate the three-dimensional(3D) position of the occlusal plane in the face is assessed.Dental virtual models and soft tissue facial morphology of 2...The repeatability of a non-invasive digital protocol proposed to evaluate the three-dimensional(3D) position of the occlusal plane in the face is assessed.Dental virtual models and soft tissue facial morphology of 20 adult subjects were digitally integrated using a 3D stereophotogrammetric imaging system.The digital 3D coordinates of facial and dental landmarks were obtained by two different operators.Camper's(facial) and occlusal(dental) planes were individuated,and their 3D relationships were measured.The repeatability of the protocol was investigated and showed no significant differences in repeated digitizations.The angle between occlusal and Camper's planes was smaller than 26 in the frontal and horizontal projections.In the sagittal projection,the angle was observed to be,on average,4.9 6.The determined occlusal plane pitch,roll and yaw values show good agreement with previously published data obtained by different protocols.The current non-invasive method was repeatable,without inter-operator differences and can facilitate assessment of healthy subjects.展开更多
文摘Occlusal disorder caused by severe worn dentition is one of the most common diseases in the occlusion. Occlusal reconstruction is an important repair method, referring to modify and rebuild the existing occlusion status, then to restore the occlusion. During occlusal reconstruction, the digital occlusion analysis system can accurately acquire the occlusion status, in order to guide the reconstruction occlusion accurately and restore the normal function of the oral maxillary system. This paper reviews the concept of occlusal reconstruction, sequence therapy, traditional occlusion analysis methods and the development status and prospect of digital occlusion analysis.
基金supported by the Aeronautical Science Foundation of China under Grant 20115169016supported in part by the technique cooperation project of ZTE on Intelligent Video Analysis in 2012
文摘To tackle the problem of severe occlusions in visual tracking, we propose a hierarchical template-matching method based on a layered appearance model. This model integrates holistic- and part-region matching in order to locate an object in a coarse-to-fine manner. Furthermore, in order to reduce ambiguity in object localization, only the discriminative parts of an object' s appearance template are chosen for similarity computing with respect to their cornerness measurements. The similarity between parts is computed in a layer-wise manner, and from this, occlusions can be evaluated. When the object is partly occluded, it can be located accurately by matching candidate regions with the appearance template. When it is completely occluded, its location can be predicted from its historical motion information using a Kalman filter. The proposed tracker is tested on several practical image sequences, and the experimental results show that it can consistently provide accurate object location for stable tracking, even for severe occlusions.
文摘The repeatability of a non-invasive digital protocol proposed to evaluate the three-dimensional(3D) position of the occlusal plane in the face is assessed.Dental virtual models and soft tissue facial morphology of 20 adult subjects were digitally integrated using a 3D stereophotogrammetric imaging system.The digital 3D coordinates of facial and dental landmarks were obtained by two different operators.Camper's(facial) and occlusal(dental) planes were individuated,and their 3D relationships were measured.The repeatability of the protocol was investigated and showed no significant differences in repeated digitizations.The angle between occlusal and Camper's planes was smaller than 26 in the frontal and horizontal projections.In the sagittal projection,the angle was observed to be,on average,4.9 6.The determined occlusal plane pitch,roll and yaw values show good agreement with previously published data obtained by different protocols.The current non-invasive method was repeatable,without inter-operator differences and can facilitate assessment of healthy subjects.